IBM-SYSTEM-RAID-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for IBM-SYSTEM-RAID-MIB.
170
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
170 total| Object Name |
|---|
ibmSystemRaidTrap OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.1.1.200.1 |
IMPORTS Unknown .1.3.6.1.4.1.2.6.159.1.1.200.1 |
ibmSystemRaidNoControllersInformational: No controllers were found in this system. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.201 |
ibmSystemRaidControllerFailError: Commands not responding on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.202 |
ibmSystemRaidDeadBatteryError: The battery-backup cache device on Controller %d needs a new battery. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.203 |
ibmSystemRaidDeadBatteryCacheError: The battery-backup cache device on Controller %d is defective %d TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.204 |
ibmSystemRaidPollingFailError: Background polling commands not responding on Controller %d %d TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.205 |
ibmSystemRaidConfigFailError: Cannot read controller configuration. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.206 |
ibmSystemRaidControllerAddedInformational: Controller %d has been added to the system. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.207 |
ibmSystemRaidControllerReplacedInformational: Controller %d has been replaced in the system. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.208 |
ibmSystemRaidControllerFailoverInformational: Controller %d failover detected. Passive controller is now active. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.209 |
ibmSystemRaidControllerVersionMismatchWarning: Controller %d version mismatch detected. The BIOS, Firmware, and Driver are not a matched set and are not compatible. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.210 |
ibmSystemRaidControllerBatteryOvertempWarning: Controller %d battery has exceeded normal operating temperature. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.211 |
ibmSystemRAIDControllerBadStripesWarning: One or more logical drives contain a bad stripe: Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.215 |
ibmSystemRaidControllerBatteryTempNormalInformational: Controller %d battery operating temperature is normal. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.216 |
ibmSystemRaidControllerStatusChangeThe status of the controller changed TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.217 |
ibmSystemRaidLogicalDriveCriticalWarning: Logical Drive %d is Critical on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.301 |
ibmSystemRaidLogicalDriveBlockedError: Logical Drive %d is Blocked on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.302 |
ibmSystemRaidLogicalDriveOffLineError: Logical Drive %d is Offline on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.303 |
ibmSystemRaidRebuildDetectedInformational: Rebuilding Logical Drive %d on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.304 |
ibmSystemRaidRebuildCompleteInformational: Rebuild complete on Logical Drive %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.305 |
ibmSystemRaidRebuildFailError: Rebuild failed on Logical Drive %d of Controller %d %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.306 |
ibmSystemRaidSyncDetectedInformational: Synchronizing Logical Drive %d on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.307 |
ibmSystemRaidSyncCompleteInformational: Synchronization complete on Logical Drive %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.308 |
ibmSystemRaidSyncFailError: Synchronization failed on Logical Drive %d of Controller %d %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.309 |
ibmSystemRaidMigrationDetectedInformational: Migrating Logical Drive %d on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.310 |
ibmSystemRaidMigrationCompleteInformational: Migration complete on Logical Drive %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.311 |
ibmSystemRaidMigrationFailError: Migration failed on Logical Drive %d of Controller %d %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.312 |
ibmSystemRaidCompressionDetectedInformational: Compressing Logical Drive %d on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.313 |
ibmSystemRaidCompressionCompleteInformational: Compression complete on Logical Drive %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.314 |
ibmSystemRaidcompressionFailError: Compression failed on Logical Drive %d of Controller %d %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.315 |
ibmSystemRaidDecompressionDetectedInformational: Decompressing Logical Drive %d on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.316 |
ibmSystemRaidDecompressionCompleteInformational: Decompression complete on Logical Drive %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.317 |
ibmSystemRaidDecompressionFailError: Decompression failed on Logical Drive %d of Controller %d %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.318 |
ibmSystemRaidFlashCopyDetectedInformational: FlashCopying Logical Drive %d on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.319 |
ibmSystemRaidFlashCopyCompleteInformational: FlashCopy complete on Logical Drive %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.320 |
ibmSystemRaidFlashCopyFailError: FlashCopy failed on Logical Drive %d of Controller %d %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.321 |
ibmSystemRaidArrayRebuildDetectedInformational: Rebuilding Array %d on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.322 |
ibmSystemRaidArrayRebuildCompleteInformational: Rebuild complete on Array %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.323 |
ibmSystemRaidArrayRebuildFailError: Rebuild failed on Array %d of Controller %d %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.324 |
ibmSystemRaidArraySyncDetectedInformational: Synchronizing Array %d on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.325 |
ibmSystemRaidArraySyncCompleteInformational: Synchronization complete on Array %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.326 |
ibmSystemRaidArraySyncFailError: Synchronization failed on Array %d of Controller %d %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.327 |
ibmSystemRaidArrayFlashCopyDetectedInformational: FlashCopying Array %d on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.328 |
ibmSystemRaidArrayFlashCopyCompleteInformational: FlashCopy complete on Array %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.329 |
ibmSystemRaidArrayFlashCopyFailError: FlashCopy failed on Array %d of Controller %d %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.330 |
ibmSystemRaidLogicalDriveUnblockedInformational: Logical Drive %d is unblocked on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.331 |
ibmSystemRaidCompactionDetectedInformational: Compacting Logical Drive %d on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.332 |
ibmSystemRaidCompactionCompleteInformational: Compaction complete on Logical Drive %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.333 |
ibmSystemRaidCompactionFailError: Compaction failed on Logical Drive %d of Controller %d %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.334 |
ibmSystemRaidExpansionDetectedInformational: Expanding Logical Drive %d on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.335 |
ibmSystemRaidExpansionCompleteInformational: Expansion complete on Logical Drive %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.336 |
ibmSystemRaidExpansionFailError: Expansion failed on Logical Drive %d of Controller %d %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.337 |
ibmSystemRaidLogicalDriveCriticalPeriodicWarning: Periodic scan found 1 or more critical logical drives on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.338 |
ibmSystemRaidCopyBackDetectedInformational: Copy back in progress on Logical Drive %d on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.339 |
ibmSystemRaidCopyBackCompleteInformational: Copy back complete on Logical Drive %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.340 |
ibmSystemRaidCopyBackFailError: Copy back failed on Logical Drive %d of Controller %d %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.341 |
ibmSystemRaidInitDetectedInformational: Initialization in progress on Logical Drive %d on Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.342 |
ibmSystemRaidInitCompleteInformational: Initialization complete on Logical Drive %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.343 |
ibmSystemRaidInitFailError: Initialization failed on Logical Drive %d of Controller %d %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.344 |
ibmSystemRAIDLogicalDriveOKInformational: Logical Drive %d of Controller %d is normal. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.345 |
ibmSystemRAIDLogicalDriveAddedInformational: Added Logical Drive %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.346 |
ibmSystemRAIDLogicalDriveRemovedInformational: Removed Logical Drive %d of Controller %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.347 |
ibmSystemRaidArrayFlashCopyStoppedThe flashcopy operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.348 |
ibmSystemRaidArrayRebuildStoppedThe array rebuild operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.349 |
ibmSystemRaidArrayStatusChangeThe array status has changed TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.350 |
ibmSystemRaidArraySyncStoppedThe array synchronization operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.351 |
ibmSystemRaidCompactionStoppedThe compaction operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.352 |
ibmSystemRaidCompressionStoppedThe compression operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.353 |
ibmSystemRaidCopybackStoppedThe copyback operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.354 |
ibmSystemRaidDecompressionStoppedThe decompression operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.355 |
ibmSystemRaidExpansionStoppedThe expansion operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.356 |
ibmSystemRaidFlashCopyStoppedThe flashcopy operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.357 |
ibmSystemRaidInitStoppedThe initialiation operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.358 |
ibmSystemRaidLogicalDriveStatusChangeThe status of the locaical drive has changed TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.359 |
ibmSystemRaidMigrationStoppedThe migration operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.360 |
ibmSystemRaidRebuildStoppedThe rebuild operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.361 |
ibmSystemRaidSyncStoppedThe synchroniation operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.362 |
ibmSystemRaidDefunctDriveError: Defunct drive on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.401 |
ibmSystemRaidPfaDriveWarning: PFA drive on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.402 |
ibmSystemRaidDefunctReplacedInformational: A drive is set to Hot-Spare on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.403 |
ibmSystemRaidDefunctDriveFruError: Defunct drive (FRU Part # %d} on controller %d, channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.404 |
ibmSystemRaidPfaDriveFruWarning: PFA drive (FRU Part # %d) on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.405 |
ibmSystemRaidUnsupportedDriveWarning: Unsupported physical drive found on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.406 |
ibmSystemRaidDriveAddedInformational: Drive added on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.407 |
ibmSystemRaidDriveRemovedInformational: Drive removed on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.408 |
ibmSystemRaidDriveClearDetectedInformational: Clear in progress on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.409 |
ibmSystemRaidDriveClearCompleteInformational: Clear complete on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.410 |
ibmSystemRaidDriveClearFailError: Clear failed on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.411 |
ibmSystemRaidDriveSyncDetectedInformational: Synchronization in progress on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.412 |
ibmSystemRaidDriveSyncCompleteInformational: Synchronization complete on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.413 |
ibmSystemRaidDriveSyncFailError: Synchronization failed on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.414 |
ibmSystemRaidDriveVerifyDetectedInformational: Verify in progress on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.415 |
ibmSystemRaidDriveVerifyCompleteInformational: Verify complete on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.416 |
ibmSystemRaidDriveVerifyFailError: Verify failed on Controller %d, Channel %d, Device ID %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.417 |
ibmSystemRaidDriveClearStoppedThe drive clear operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.418 |
ibmSystemRaidDriveSecureEraseStoppedThe secure erase operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.419 |
ibmSystemRaidDriveStatusChangeThe drive status has changed TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.420 |
ibmSystemRaidDriveSyncStoppedThe sychronization operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.421 |
ibmSystemRaidDriveVerifyStoppedThe verify operation has stopped TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.422 |
ibmSystemRaidSpareCreatedibmSystemRaidSpareCreated TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.423 |
ibmSystemRaidSpareDeletedibmSystemRaidSpareDeleted TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.424 |
ibmSystemRaidEnclosureOKInformational: Enclosure device responding on Controller %d, Channel %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.501 |
ibmSystemRaidEnclosureFailError: Enclosure device not responding on Controller %d, Channel %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.502 |
ibmSystemRaidFanOkInformational: Enclosure fan %d on Controller %d, Channel %d is now operational. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.503 |
ibmSystemRaidFanFailError: Enclosure fan %d on Controller %d, Channel %d is malfunctioning. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.504 |
ibmSystemRaidFanInstalledInformational: Enclosure fan %d on Controller %d, Channel %d has been installed. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.505 |
ibmSystemRaidFanRemovedWarning: Enclosure fan %d on Controller %d, Channel %d has been removed. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.506 |
ibmSystemRaidTempOkError: Enclosure temperature is in normal range on Controller %d, Channel %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.507 |
ibmSystemRaidTempFailError: Enclosure temperature is out of normal range on Controller %d, Channel %d. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.508 |
ibmSystemRaidPowerSupplyOkInformational: Enclosure power supply %d on Controller %d, Channel %d is now operational. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.509 |
ibmSystemRaidPowerSupplyFailError: Enclosure power supply %d on Controller %d, Channel %d is malfunctioning. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.510 |
ibmSystemRaidPowerSupplyInstalledInformational: Enclosure power supply %d on Controller %d, Channel %d has been installed. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.511 |
ibmSystemRaidPowerSupplyRemovedWarning: Enclosure power supply %d on Controller %d, Channel %d has been removed. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.512 |
ibmSystemRaidTestTrapInformational: This is a test trap. TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.601 |
ibmSystemRaidLsiPDFailA physical drive has failed in a RAID configuration TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.1000 |
ibmSystemRaidLsiPDPartOfLDFailA physical drive has failed in a logical drive TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.1003 |
ibmSystemRaidLsiPDPartOfLDAddA drive has been added to a RAID configuration TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.1004 |
ibmSystemRaidLsiHSPartOfLDibmSystemRaidLsiHSPartOfLD TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.1005 |
ibmSystemRaidLsiHSFailA hot spare drive has failed in a RAID configuration TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.1007 |
ibmSystemRaidLsiPDHSA physical drive has been made a hot spare in the RAID configuration TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.1008 |
ibmSystemRaidLsiLDOfflineA logical drive is in the offline state TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.1009 |
ibmSystemRaidLsiLDDegradedA logical drive has been degraded in a RAID configuration TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.1011 |
ibmSystemRaidLsiLDOptimalA logical drive is functioning correctly TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.1012 |
ibmSystemRaidLsiSMARTErrorA PFA has been detected on a drive in the RAID configuration TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.1013 |
ibmSystemRaidLsiRbldStartA RAID rebuild operation is in progress on an array in the RAID configuration TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.1015 |
ibmSystemRaidLsiRbldCompleteA RAID rebuild operation has completed on an array in the RAID configuration TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.1016 |
ibmSystemRaidLsiRbldFailA RAID rebuild operation has failed on an array in the RAID configuration TRAP-TYPE .1.3.6.1.4.1.2.6.159.1.1.200.1.0.1017 |
ibmSystemRaidControllerTableThe IBMPSG_RAIDController class represents a RAID Controller SEQUENCE OF IbmSystemRaidControllerEntry .1.3.6.1.4.1.2.6.159.1.1.200.2 |
ibmSystemRaidControllerEntryThis class defines an entry for each IBMPSG_RAIDController
instance. Each instance of the IBMPSG_RAIDController class
contains status and descriptive information for each disk
recognized by the Director SMART provider. IbmSystemRaidControllerEntry .1.3.6.1.4.1.2.6.159.1.1.200.2.1 |
ibmSystemRaidControllerKeyIndexThe RAID controller table index number (controller1, controller2, etc.)ro String .1.3.6.1.4.1.2.6.159.1.1.200.2.1.1 |
ibmSystemRaidControllerControllerIDThe DeviceID that identifies the diskro String .1.3.6.1.4.1.2.6.159.1.1.200.2.1.2 |
ibmSystemRaidControllerModelThe model of the controllerro String .1.3.6.1.4.1.2.6.159.1.1.200.2.1.3 |
ibmSystemRaidControllerBIOSVersionThe version of the controllers BIOSro String .1.3.6.1.4.1.2.6.159.1.1.200.2.1.4 |
ibmSystemRaidControllerFirmwareVersionThe version of the controllers firmwarro String .1.3.6.1.4.1.2.6.159.1.1.200.2.1.5 |
ibmSystemRaidControllerDriverVersionThe version of the controllers device driverro String .1.3.6.1.4.1.2.6.159.1.1.200.2.1.6 |
ibmSystemRaidControllerManufacturerthe manufacturer of the controllerro String .1.3.6.1.4.1.2.6.159.1.1.200.2.1.7 |
ibmSystemRaidControllerSlotThe slot number the controller resides inro Uint16 .1.3.6.1.4.1.2.6.159.1.1.200.2.1.8 |
ibmSystemRaidControllerFRUThe FRU number of the controllerro String .1.3.6.1.4.1.2.6.159.1.1.200.2.1.9 |
ibmSystemRaidControllerSerialNumberThe controllers serial numberro String .1.3.6.1.4.1.2.6.159.1.1.200.2.1.10 |
ibmSystemRaidControllerInitiatorIDsSpecifies the controllers initiator IDs using a comma as the delimiterro String .1.3.6.1.4.1.2.6.159.1.1.200.2.1.11 |
ibmSystemRaidControllerStatusThe current status of the controllerro String .1.3.6.1.4.1.2.6.159.1.1.200.2.1.12 |
ibmSystemRaidDiskDriveTableThe IBMPSG_RAIDDiskDrive class represents a RAID physical disk SEQUENCE OF IbmSystemRaidDiskDriveEntry .1.3.6.1.4.1.2.6.159.1.1.200.3 |
ibmSystemRaidDiskDriveEntryThis class defines an entry for each IBMPSG_RAIDDiskDrive
instance. Each instance of the IBMPSG_RAIDDiskDrive class
contains status and descriptive information for each disk
attached to the RAID controller. IbmSystemRaidDiskDriveEntry .1.3.6.1.4.1.2.6.159.1.1.200.3.1 |
ibmSystemRaidDiskDriveKeyIndexThe Physical Disk Drive table index number (Disk Drive 0, Disk Drive 1, etc.)ro String .1.3.6.1.4.1.2.6.159.1.1.200.3.1.1 |
ibmSystemRaidDiskDriveDeviceIDThe device ID of the drivero String .1.3.6.1.4.1.2.6.159.1.1.200.3.1.2 |
ibmSystemRaidDiskDriveDiskDriveIDThe target ID of the disk drivero String .1.3.6.1.4.1.2.6.159.1.1.200.3.1.3 |
ibmSystemRaidDiskDriveControllerIDThe ID of the controller it is attached toro String .1.3.6.1.4.1.2.6.159.1.1.200.3.1.4 |
ibmSystemRaidDiskDriveChannelIDThe channel on the controller the drive is attached toro String .1.3.6.1.4.1.2.6.159.1.1.200.3.1.5 |
ibmSystemRaidDiskDriveFirmwareThe firmware revision of the drivero String .1.3.6.1.4.1.2.6.159.1.1.200.3.1.6 |
ibmSystemRaidDiskDriveStateThe current state of the physical drive.
0=Empty, 1=Standby, 4=Defunct Hot Spare, 5=Standby
Hot Spare, 8=Defunct Disk Drive, 129=Ready,
133=Hot Spare, 137=Online, 139=Rebuild, 254=Reservedro Uint16 .1.3.6.1.4.1.2.6.159.1.1.200.3.1.7 |
ibmSystemRaidDiskDriveStatusThe status of the drivero String .1.3.6.1.4.1.2.6.159.1.1.200.3.1.8 |
ibmSystemRaidLogicalDriveTableThe IBMPSG_RAIDLogicalDrive class represents a RAID Logical disk (Logical Drive 0, Logical Drive 1, etc.) SEQUENCE OF IbmSystemRaidLogicalDriveEntry .1.3.6.1.4.1.2.6.159.1.1.200.4 |
ibmSystemRaidLogicalDriveEntryThis class defines an entry for each IBMPSG_RAIDLogicalDrive
instance. Each instance of the IBMPSG_RAIDLogicalDrive class
contains status and descriptive information for each RAID
Logical disk. IbmSystemRaidLogicalDriveEntry .1.3.6.1.4.1.2.6.159.1.1.200.4.1 |
ibmSystemRaidLogicalDriveKeyIndexThe Logical Disk Drive table index number (Logical Drive 0, Logical Drive 1, etc.)ro String .1.3.6.1.4.1.2.6.159.1.1.200.4.1.1 |
ibmSystemRaidLogicalDriveLogicalDriveIDThe ID of the logical drivero String .1.3.6.1.4.1.2.6.159.1.1.200.4.1.2 |
ibmSystemRaidLogicalDriveControllerIDThe ID of the controller the logical drive belongs toro String .1.3.6.1.4.1.2.6.159.1.1.200.4.1.3 |
ibmSystemRaidLogicalDriveArrayIDThe ID of the array that the logical drive belongs toro String .1.3.6.1.4.1.2.6.159.1.1.200.4.1.4 |
ibmSystemRaidLogicalDriveRAIDLevelThe RAID level of the logical drive (RAID 1, RAID 5, etc.)ro String .1.3.6.1.4.1.2.6.159.1.1.200.4.1.5 |
ibmSystemRaidLogicalDriveDataSpaceSize of the logical drive in megabytesro Uint64 .1.3.6.1.4.1.2.6.159.1.1.200.4.1.6 |
ibmSystemRaidLogicalDriveParitySpaceParity space of the logical drive in megabytesro Uint64 .1.3.6.1.4.1.2.6.159.1.1.200.4.1.7 |
ibmSystemRaidLogicalDriveIsBlockedThe logical drive is in a blocked statero Boolean .1.3.6.1.4.1.2.6.159.1.1.200.4.1.8 |
ibmSystemRaidLogicalDriveStateThe current state of the logical drive.
0=Free, 2=Offline, 3=Okay, 4=Critical,
5=Logical Drive Migration, 6=System,
20=Critical Logical Drive Migration,
36=Critical Systemro Uint16 .1.3.6.1.4.1.2.6.159.1.1.200.4.1.9 |
ibmSystemRaidLogicalDriveStatusThe status of the logical drivero String .1.3.6.1.4.1.2.6.159.1.1.200.4.1.10 |
ibmSystemRaidTrapInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.1.1.200.5 |
ibmSystemRaidTrapProviderNameThe CIM Provider Name String .1.3.6.1.4.1.2.6.159.1.1.200.5.1 |
ibmSystemRaidTrapEventIDEvent ID String .1.3.6.1.4.1.2.6.159.1.1.200.5.2 |
ibmSystemRaidTrapPerceivedSeveritySeverity of the event
0=Normal / OK
1=Warning
2=Critical INTEGER .1.3.6.1.4.1.2.6.159.1.1.200.5.3 |
ibmSystemRaidDescriptionThe event message String .1.3.6.1.4.1.2.6.159.1.1.200.5.4 |
ibmSystemRaidTrapEventTimeTime that the event occured String .1.3.6.1.4.1.2.6.159.1.1.200.5.5 |