IBM-SYSTEM-LMSENSOR-MIB
Detailed view of the defined objects, syntax rules, and hierarchical paths.
90
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
90 total| Object Name |
|---|
IMPORTSThe IBMPSG_TemperatureSensor class represents an IBM managed Temperature Sensor. SEQUENCE OF IbmSystemTemperatureSensorEntry .1.3.6.1.4.1.2.6.159.1.1.80.1 |
ibmSystemVoltageSensorTableThe IBMPSG_VoltageSensor class represents an IBM managed voltage Sensor. SEQUENCE OF IbmSystemVoltageSensorEntry .1.3.6.1.4.1.2.6.159.1.1.80.2 |
ibmSystemVoltageSensorEntryA sequence of voltage sensor readings IbmSystemVoltageSensorEntry .1.3.6.1.4.1.2.6.159.1.1.80.2.1 |
ibmSystemVoltageSensorKeyIndexThe index used by this tablero String .1.3.6.1.4.1.2.6.159.1.1.80.2.1.1 |
ibmSystemVoltageSensorCurrentReadingThe current voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.2 |
ibmSystemVoltageSensorNominalReadingThe nominal voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.3 |
ibmSystemVoltageSensorNormalMaxThe normal maximum voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.4 |
ibmSystemVoltageSensorNormalMinThe normal minimum voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.5 |
ibmSystemVoltageSensorMaxReadableThe maximum voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.6 |
ibmSystemVoltageSensorMinReadableThe minimum voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.7 |
ibmSystemVoltageSensorResolutionThe resolution of the voltage reading for this sensorro Uint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.8 |
ibmSystemVoltageSensorToleranceThe tolerance of the voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.9 |
ibmSystemVoltageSensorAccuracyThe accuracy of the voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.10 |
ibmSystemVoltageSensorLowerThresholdNonCriticalThe non-critical lower threshold voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.11 |
ibmSystemVoltageSensorUpperThresholdNonCriticalThe non-critical upper threshold voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.12 |
ibmSystemVoltageSensorLowerThresholdCriticalThe critical lower threshold voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.13 |
ibmSystemVoltageSensorUpperThresholdCriticalThe non-critical upper threshold voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.14 |
ibmSystemVoltageSensorLowerThresholdFatalThe fatal lower threshold voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.15 |
ibmSystemVoltageSensorUpperThresholdFatalThe fatal upper threshold voltage reading for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.16 |
ibmSystemVoltageSensorVoltageTypeThe Voltage Descriptionro Uint32 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.17 |
ibmSystemVoltageSensorEventsEnabledEvent generation status. [True | False]ro Boolean .1.3.6.1.4.1.2.6.159.1.1.80.2.1.18 |
ibmSystemVoltageSensorPollingIntervalPolling interval is measured in seconds. Value of zero
indicates do it once and quit. Minimum polling interval
is ten seconds.ro Uint64 .1.3.6.1.4.1.2.6.159.1.1.80.2.1.19 |
ibmSystemVoltageSensorEventAutoClearEnabledFalse means that events are only generated on state changes.
True means that events are generated on state changes and
periodically when the object is in a non-normal state. [True | False]ro Boolean .1.3.6.1.4.1.2.6.159.1.1.80.2.1.20 |
ibmSystemVoltageSensorStatusThe Status property is a string indicating the current status
of the object. Various operational and non-operational statuses
can be defined. Operational statuses are OK, Degraded and Pred
Fail. Pred Fail indicates that an element may be functioning
properly but predicting a failure in the near future. An example
is a SMART-enabled hard drive. Non-operational statuses can also
be specified. These are Error, Starting, Stopping and Service.
The latter, Service, could apply during mirror-resilvering of a
disk, reload of a user permissions list, or other administrative
work. Not all such work is on-line, yet the managed element is
neither OK nor in one of the other states.
OK = Normal
Error = Criticalro String .1.3.6.1.4.1.2.6.159.1.1.80.2.1.21 |
ibmSystemFanTableThe IBMPSG_Fan class represents an IBM managed fan sensor. SEQUENCE OF IbmSystemFanEntry .1.3.6.1.4.1.2.6.159.1.1.80.3 |
ibmSystemFanEntryA sequence of fan sensor readings IbmSystemFanEntry .1.3.6.1.4.1.2.6.159.1.1.80.3.1 |
ibmSystemFanKeyIndexThe index used by this tablero String .1.3.6.1.4.1.2.6.159.1.1.80.3.1.1 |
ibmSystemFanVariableSpeedStates if this fan supports variable speeds [True | False]ro Boolean .1.3.6.1.4.1.2.6.159.1.1.80.3.1.2 |
ibmSystemFanDesiredSpeedThe desired speed in revolutions per minute for this fanro String .1.3.6.1.4.1.2.6.159.1.1.80.3.1.3 |
ibmSystemFanActiveCoolingStates if this fan supports active cooling [True | False]ro Boolean .1.3.6.1.4.1.2.6.159.1.1.80.3.1.4 |
ibmSystemFanFanTypeThe current fan type.ro Uint32 .1.3.6.1.4.1.2.6.159.1.1.80.3.1.5 |
ibmSystemFanEventsEnabledEvent generation status. [True | False]ro Boolean .1.3.6.1.4.1.2.6.159.1.1.80.3.1.6 |
ibmSystemFanPollingIntervalPolling interval is measured in seconds. Value of zero indicates
do it once and quit. Minimum polling interval is ten seconds.ro Uint64 .1.3.6.1.4.1.2.6.159.1.1.80.3.1.7 |
ibmSystemFanEventAutoClearEnabledFalse means that events are only generated on state changes. True
means that events are generated on state changes and periodically
when the object is in a non-normal state.ro Boolean .1.3.6.1.4.1.2.6.159.1.1.80.3.1.8 |
ibmSystemFanStatusThe Status property is a string indicating the current
status of the object. Various operational and non-operational
statuses can be defined. Operational statuses are OK, Degraded
and Pred Fail. Pred Fail indicates that an element may be
functioning properly but predicting a failure in the near
future. An example is a SMART-enabled hard drive. Non-operational
statuses can also be specified. These are Error, Starting,
Stopping and Service. The latter, Service, could apply during
mirror-resilvering of a disk, reload of a user permissions list,
or other administrative work. Not all such work is on-line, yet
the managed element is neither OK nor in one of the other states.
OK = Normal
Error = Criticalro String .1.3.6.1.4.1.2.6.159.1.1.80.3.1.9 |
ibmSystemSystemEnclosureTableThe IBMPSG_SystemEnclosure class represents an IBM chassis sensor. SEQUENCE OF IbmSystemSystemEnclosureEntry .1.3.6.1.4.1.2.6.159.1.1.80.4 |
ibmSystemSystemEnclosureEntryA sequence of enclosure readings IbmSystemSystemEnclosureEntry .1.3.6.1.4.1.2.6.159.1.1.80.4.1 |
ibmSystemSystemEnclosureKeyIndexThe index used by this tablero String .1.3.6.1.4.1.2.6.159.1.1.80.4.1.1 |
ibmSystemSystemEnclosureIntrusionStatusThe intrusion statusro Uint32 .1.3.6.1.4.1.2.6.159.1.1.80.4.1.2 |
ibmSystemSystemEnclosureIntrusionTypeThe intrusion typero Uint32 .1.3.6.1.4.1.2.6.159.1.1.80.4.1.3 |
ibmSystemSystemEnclosureEventsEnabledEvent generation enabled status. [True | False]ro Boolean .1.3.6.1.4.1.2.6.159.1.1.80.4.1.4 |
ibmSystemSystemEnclosurePollingIntervalPolling interval is measured in seconds. Value of zero indicates
do it once and quit. Minimum polling interval is ten seconds.ro Uint64 .1.3.6.1.4.1.2.6.159.1.1.80.4.1.5 |
ibmSystemSystemEnclosureDockingStatusThis defines whether system is docked or notro Uint16 .1.3.6.1.4.1.2.6.159.1.1.80.4.1.6 |
ibmSystemSystemEnclosureACLineStatusThis group defines status information about the AC line in the notebookro Uint16 .1.3.6.1.4.1.2.6.159.1.1.80.4.1.7 |
ibmSystemSystemEnclosureEventAutoClearEnabledFalse means that events are only generated on state changes. True
means that events are generated on state changes and periodically
when the object is in a non-normal state. [True | False]ro Boolean .1.3.6.1.4.1.2.6.159.1.1.80.4.1.8 |
ibmSystemSystemEnclosureStatusThe Status property is a string indicating the current status of
the object. Various operational and non-operational statuses can
be defined. Operational statuses are OK, Degraded and Pred Fail.
Pred Fail indicates that an element may be functioning properly
but predicting a failure in the near future. An example is a
SMART-enabled hard drive. Non-operational statuses can also be
specified. These are Error, Starting, Stopping and Service. The
latter, Service, could apply during mirror-resilvering of a disk,
reload of a user permissions list, or other administrative work.
Not all such work is on-line, yet the managed element is neither
OK nor in one of the other states.
OK = Normal
Error = Criticalro String .1.3.6.1.4.1.2.6.159.1.1.80.4.1.9 |
ibmSystemTachometerTableThe IBMPSG_Tachometer class represents an IBM managed Fan speed Sensor. SEQUENCE OF IbmSystemTachometerEntry .1.3.6.1.4.1.2.6.159.1.1.80.5 |
ibmSystemTachometerEntryA sequence of fan enclosure readings IbmSystemTachometerEntry .1.3.6.1.4.1.2.6.159.1.1.80.5.1 |
ibmSystemTachometerKeyIndexThe index used by this tablero String .1.3.6.1.4.1.2.6.159.1.1.80.5.1.1 |
ibmSystemTachometerCurrentReadingThe current fan reading in revolutions per minute for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.2 |
ibmSystemTachometerNominalReadingThe nominal fan reading in revolutions per minute for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.3 |
ibmSystemTachometerNormalMaxThe normal maximum fan reading in revolutions per minute for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.4 |
ibmSystemTachometerNormalMinThe normal minimum fan reading in revolutions per minute for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.5 |
ibmSystemTachometerMaxReadableThe maximum readable fan reading in revolutions per minute for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.6 |
ibmSystemTachometerMinReadableThe minimum readable fan reading in revolutions per minute for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.7 |
ibmSystemTachometerResolutionThe resolution of this fan reading in revolutions per minute for this sensorro Uint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.8 |
ibmSystemTachometerToleranceThe tolerance of this fan reading in revolutions per minute for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.9 |
ibmSystemTachometerLowerThresholdNonCriticalThe non-critical lower threshold fan reading in revolutions per minute for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.10 |
ibmSystemTachometerUpperThresholdNonCriticalThe non-critical upper threshold fan reading in revolutions per minute for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.11 |
ibmSystemTachometerLowerThresholdCriticalThe critical lower threshold fan reading in revolutions per minute for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.12 |
ibmSystemTachometerUpperThresholdCriticalThe critical upper threshold fan reading in revolutions per minute for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.13 |
ibmSystemTachometerLowerThresholdFatalThe fatal lower threshold fan reading in revolutions per minute for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.14 |
ibmSystemTachometerUpperThresholdFatalThe fatal upper threshold fan reading in revolutions per minute for this sensorro Sint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.15 |
ibmSystemTachometerFanDescripThe Fan Description.ro Uint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.16 |
ibmSystemTachometerFanTypeThe current fan type.ro Uint32 .1.3.6.1.4.1.2.6.159.1.1.80.5.1.17 |
ibmSystemTachometerEventsEnabledEvent generation status.ro Boolean .1.3.6.1.4.1.2.6.159.1.1.80.5.1.18 |
ibmSystemTachometerEventAutoClearEnabledFalse means that events are only generated on state changes. True means
that events are generated on state changes and periodically when the
object is in a non-normal state.ro Boolean .1.3.6.1.4.1.2.6.159.1.1.80.5.1.19 |
ibmSystemTachometerStatusThe Status property is a string indicating the current status of the
object. Various operational and non-operational statuses can be defined.
Operational statuses are OK, Degraded and Pred Fail. Pred Fail indicates
that an element may be functioning properly but predicting a failure in
the near future. An example is a SMART-enabled hard drive. Non-operational
statuses can also be specified. These are Error, Starting, Stopping and
Service. The latter, Service, could apply during mirror-resilvering of a
disk, reload of a user permissions list, or other administrative work. Not
all such work is on-line, yet the managed element is neither OK nor in one
of the other states.
OK = Normal
Error = Criticalro String .1.3.6.1.4.1.2.6.159.1.1.80.5.1.20 |
ibmSystemTemperatureSensorEntryA sequence of temperature sensor entries IbmSystemTemperatureSensorEntry .ibmSystemTemperatureSensorTable.1 |
ibmSystemTemperatureSensorKeyIndexThe index used by this tablero String .ibmSystemTemperatureSensorTable.1.1 |
ibmSystemTemperatureSensorCurrentReadingThe current Celcius temperature reading for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.2 |
ibmSystemTemperatureSensorNominalReadingThe nominal Celcius temperature reading for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.3 |
ibmSystemTemperatureSensorNormalMaxThe normal maximum Celcius temperature reading for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.4 |
ibmSystemTemperatureSensorNormalMinThe normal minimum Celcius temperature reading for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.5 |
ibmSystemTemperatureSensorMaxReadableThe maximum readable Celcius temperature reading for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.6 |
ibmSystemTemperatureSensorMinReadableThe minimum readalbe Celcius temperature reading for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.7 |
ibmSystemTemperatureSensorResolutionThe resolution in Celcius of the temperature reading for this sensorro Uint32 .ibmSystemTemperatureSensorTable.1.8 |
ibmSystemTemperatureSensorToleranceThe tolerance in Celcius of the temperature reading for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.9 |
ibmSystemTemperatureSensorAccuracyThe degree of accuracy in Celcius of the temperature reading for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.10 |
ibmSystemTemperatureSensorLowerThresholdNonCriticalThe lower non-critical threshold in Celcius for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.11 |
ibmSystemTemperatureSensorUpperThresholdNonCriticalThe upper non-critical threshold in Celcius for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.12 |
ibmSystemTemperatureSensorLowerThresholdCriticalThe lower critical threshold in Celcius for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.13 |
ibmSystemTemperatureSensorUpperThresholdCriticalThe upper critical threshold in Celcius for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.14 |
ibmSystemTemperatureSensorLowerThresholdFatalThe lower fatal threshold in Celcius for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.15 |
ibmSystemTemperatureSensorUpperThresholdFatalThe upper fatal threshold in Celcius for this sensorro Sint32 .ibmSystemTemperatureSensorTable.1.16 |
ibmSystemTemperatureSensorTempLocationThe current temperature sensor locationro Uint32 .ibmSystemTemperatureSensorTable.1.17 |
ibmSystemTemperatureSensorEventsEnabledEvent generation status [True | False]ro Boolean .ibmSystemTemperatureSensorTable.1.18 |
ibmSystemTemperatureSensorPollingIntervalPolling interval is measured in seconds. Value of zero
indicates do it once and quit. Minimum polling interval
is ten seconds.ro Uint64 .ibmSystemTemperatureSensorTable.1.19 |
ibmSystemTemperatureSensorEventAutoClearEnabledFalse means that events are only generated on state changes.
True means that events are generated on state changes and
periodically when the object is in a non-normal state.ro Boolean .ibmSystemTemperatureSensorTable.1.20 |
ibmSystemTemperatureSensorStatusThe Status property is a string indicating the current status
of the object. Various operational and non-operational statuses
can be defined. Operational statuses are OK, Degraded and Pred
Fail. Pred Fail indicates that an element may be functioning
properly but predicting a failure in the near future. An example
is a SMART-enabled hard drive. Non-operational statuses can also
be specified. These are Error, Starting, Stopping and Service.
The latter, Service, could apply during mirror-resilvering of a
disk, reload of a user permissions list, or other administrative
work. Not all such work is on-line, yet the managed element is
neither OK nor in one of the other states.
Ok = Normal
Error = Criticalro String .ibmSystemTemperatureSensorTable.1.21 |