Home/Catalog/IBM-MIB

IBM-MIB

AI MIB Summary

The IBM-MIB module provides SNMP objects and notifications for monitoring the operational status, performance counters, and fault conditions of IBM FlashSystem storage arrays. It enables the tracking of critical infrastructure metrics such as drive health, controller states, cache utilization, and I/O throughput to facilitate proactive storage management and alerting.

Objects and notifications for monitoring an IBM FlashSystem
Main OID:
flashsystemProduct.1.3.6.1.4.1.2.6.255.1
480
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

480 total
Object Name
ibm
OBJECT IDENTIFIER
.1.3.6.1.4.1.2
ibmProd
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6
ibmFlashsystems
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.255
flashsystemProductObjects and notifications for monitoring an IBM FlashSystem
MODULE-IDENTITY
.1.3.6.1.4.1.2.6.255.1
ibmflashTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.255.1.0
flashETrapflash error trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.2.6.255.1.0.1
flashWTrapflash warning trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.2.6.255.1.0.2
flashITrapflash information trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.2.6.255.1.0.3
ibmflashObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.255.1.1
ibmflashSystem
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.255.1.1.1
systemTypeSystem Typero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.1
systemVersionFirmware Versionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.2
systemActiveNodeActive Nodero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.3
systemNode1IPNode 1 IP Addressro
IpAddress
.1.3.6.1.4.1.2.6.255.1.1.1.4
systemNode1MaskNode 1 IP Maskro
IpAddress
.1.3.6.1.4.1.2.6.255.1.1.1.5
systemNode1GWNode 1 IP Gatewayro
IpAddress
.1.3.6.1.4.1.2.6.255.1.1.1.6
systemNode1IPModeNode 1 IP Mode (static, dynamic)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.7
systemNode2IPNode 2 IP Addressro
IpAddress
.1.3.6.1.4.1.2.6.255.1.1.1.8
systemNode2MaskNode 2 IP Maskro
IpAddress
.1.3.6.1.4.1.2.6.255.1.1.1.9
systemNode2GWNode 2 IP Gatewayro
IpAddress
.1.3.6.1.4.1.2.6.255.1.1.1.10
systemNode2IPModeNode 2 IP Mode (static, dynamic)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.11
systemIOPSTotal IOPSro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.1.12
systemReadIOPSTotal Read IOPSro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.1.13
systemWriteIOPSTotal Write IOPSro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.1.14
systemBWTotal Bandwidthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.1.15
systemReadBWTotal Read Bandwidthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.1.16
systemWriteBWTotal Write Bandwidthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.1.17
eventTableTable of system event logs
SEQUENCE OF EventEntry
.1.3.6.1.4.1.2.6.255.1.1.1.50
eventEntryEvent entry
EventEntry
.1.3.6.1.4.1.2.6.255.1.1.1.50.1
eventIndexindex
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.50.1.1
eventSequenceevent sequencero
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.50.1.2
eventTimestampevent timestampro
OCTET STRING
.1.3.6.1.4.1.2.6.255.1.1.1.50.1.3
eventObjectTypeevent object typero
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.1.50.1.4
eventObjectIdevent object idro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.50.1.5
eventObjectNameevent object namero
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.1.50.1.6
eventCopyIdevent copy idro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.50.1.7
eventStatusevent statusro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.1.50.1.8
eventFixedevent fixedro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.1.50.1.9
eventEventIdevent event idro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.50.1.10
eventErrorCodeevent error codero
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.50.1.11
eventDescriptionevent descriptionro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.1.50.1.12
driveTableTable of system drives
SEQUENCE OF DriveEntry
.1.3.6.1.4.1.2.6.255.1.1.1.51
driveEntryDrive entry
DriveEntry
.1.3.6.1.4.1.2.6.255.1.1.1.51.1
driveIndexindex
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.51.1.1
driveIdDrive Idro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.51.1.2
driveStatusDrive Statusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.51.1.3
driveUseDrive Usage (member, spare, candidate, unused, failed)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.51.1.4
driveCapacityDrive Capacityro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.51.1.5
driveSlotIdDrive Slot Numberro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.51.1.6
driveArrayIdDrive Array Numberro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.51.1.7
driveEncryptionDrive Encryptedro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.51.1.8
arrayTableTable of system arrays
SEQUENCE OF ArrayEntry
.1.3.6.1.4.1.2.6.255.1.1.1.52
arrayEntryArray entry
ArrayEntry
.1.3.6.1.4.1.2.6.255.1.1.1.52.1
arrayIndexindex
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.52.1.1
arrayIdArray IDro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.52.1.2
arrayStatusArray Status (online, offline, excluded, degraded)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.52.1.3
arrayCapacityArray Capacityro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.52.1.4
arrayCapacityUsedUsed Array Capacityro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.52.1.5
arrayCapacityFreeFree Array Capacityro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.52.1.6
arrayRAIDLvlArray RAID Levelro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.52.1.7
arrayEncryptionArray Encryptedro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.52.1.8
arrayVDiskCountNumber of VDisksro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.52.1.9
vdiskTableTable of system vdisks
SEQUENCE OF VDiskEntry
.1.3.6.1.4.1.2.6.255.1.1.1.53
vdiskEntryVDisk entry
VDiskEntry
.1.3.6.1.4.1.2.6.255.1.1.1.53.1
vdiskIndexindex
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.53.1.1
vdiskIdVDisk Idro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.53.1.2
vdiskNameVDisk Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.53.1.3
vdiskStatusVDisk Statusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.53.1.4
vdiskCapacityVDisk Capacityro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.53.1.5
vdiskUIDVDisk Unique Identifierro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.53.1.6
nodeTableTable of system nodes
SEQUENCE OF NodeEntry
.1.3.6.1.4.1.2.6.255.1.1.1.54
nodeEntryNode entry
NodeEntry
.1.3.6.1.4.1.2.6.255.1.1.1.54.1
nodeIndexindex
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.54.1.1
nodePanelNameNode Panel Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.54.1.2
nodeClusterIdNode Cluster IDro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.54.1.3
nodeClusterNmNode Cluster Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.54.1.4
nodeIdNode IDro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.1.54.1.5
nodeNameNode Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.54.1.6
nodeRelationNode Relation (local, parner)ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.54.1.7
nodeStatusNode Statusro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.54.1.8
nodeErrorNode Error Dataro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2.6.255.1.1.1.54.1.9
ibmflashInterfaces
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.255.1.1.2
fcTableFibre channel info table
SEQUENCE OF FCTableEntry
.1.3.6.1.4.1.2.6.255.1.1.2.1
fcTableEntryFC table entry
FCTableEntry
.1.3.6.1.4.1.2.6.255.1.1.2.1.1
fcTableIndexindex N.B. Order changed in 900 and 840 SP2
Integer32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.1
fcObjectFC object namero
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.2
fcFirmwareVersionFC firmware versionro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.3
fcPortIDFC port IDro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.4
fcStateFC State which indicates the link state of the specified port: None - No state available No Light - Nothing is plugged into the fc port Offline - A device is plugged into the fc port, but the linkup procedure has not completed successfully Online - The port is online and functional from a link point of view Disabled - The port has been disabled, likely because the system is restoring memory from disk, or preparing to psuoff.ro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.5
fcWWNNFC node namero
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.6
fcWWPNFC port namero
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.7
fcTopoFC Topology indicates specified ports topology: Unknown - A SNMP reporting error has occured None - The system has not completed linkup so no topology can be determined PP - Point to point topology AL - Arbitrated loop topology Fabric - Linked up with fabric in point to point F_Port - FL_Port - Linked up with fabric in arbitrated loopro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.8
fcSpeedFC Link Speed indicates the specified port's link speedro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.9
fcTopoConfigFC Topology configuration: Unknown - A SNMP reporting error has occured Auto - PP - Point to point topology AL - Arbitrated loop topologyro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.10
fcSpeedConfigFC Link Speed configurationro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.11
fcBWBandwidthro
Unsigned32 UNITS "MB/s"
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.12
fcReadBWRead Bandwidthro
Unsigned32 UNITS "MB/s"
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.13
fcWriteBWWrite Bandwidthro
Unsigned32 UNITS "MB/s"
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.14
fcIOPSIO's per secondro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.15
fcReadIOPSRead IO's per secondro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.16
fcWriteIOPSWrite IO's per secondro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.17
fcQueueDepthQueue depthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.18
fcReadQueueDepthRead Queue depthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.19
fcWriteQueueDepthWrite Queue depthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.20
fcReadAvgLatencyAverage SCSI read latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.21
fcReadMaxLatencyMaximum SCSI read latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.22
fcReadSampleLowSamples of SCSI read with latency <= 1msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.23
fcReadSampleMedSamples of SCSI read with latency in range (1ms, 10ms)ro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.24
fcReadSampleHighSamples of SCSI read with latency >= 10msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.25
fcWriteAvgLatencyAverage SCSI write latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.26
fcWriteMaxLatencyMaximum SCSI write latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.27
fcWriteSampleLowSamples of SCSI write with latency <= 1msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.28
fcWriteSampleMedSamples of SCSI write with latency in range (1ms, 10ms)ro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.29
fcWriteSampleHighSamples of SCSI write with latency >= 10msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.30
fcbs2k2k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.31
fcbs4k4k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.32
fcbs8k8k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.33
fcbs16k16k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.34
fcbs32k32k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.35
fcbs64k64k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.36
fcbs128k128k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.37
fcbs256k256k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.38
fcReadScsiCountScsi read countro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.39
fcWriteScsiCountScsi write countro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.40
fcReadScsiBytesScsi read bytesro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.41
fcWriteScsiBytesScsi write bytesro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.42
fcCorrMediaErrCorrectable media errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.43
fcUncorrMediaErrUncorrectable media errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.44
fcTimeTickTime ticksro
Unsigned32 UNITS "1/100th seconds"
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.45
fcalign512512 aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.46
fcalign1k1k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.47
fcalign2k2k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.48
fcalign4k4k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.49
fcalign8k8k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.50
fcalign16k16k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.51
fcalign32k32k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.52
fcalign64k64k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.53
fcRMWCountRead-Modify-Write Countro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.54
fcLinkDownLink Down Countro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.55
fcCRCErrCRC Errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.56
fcTXFramesFrames Transmittedro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.57
fcRXFramesFrames Receivedro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.58
fcRXErrRX Errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.59
fcXchgLookupErrNumber of invalid xchg records receivedro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.60
fcAbtsCntNumber of ABTS frames receivedro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.61
fcRscnCntNumber of SCNs receivedro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.1.1.62
ibTableInfiniBand port info table
SEQUENCE OF IBTableEntry
.1.3.6.1.4.1.2.6.255.1.1.2.2
ibTableEntryIB table entry
IBTableEntry
.1.3.6.1.4.1.2.6.255.1.1.2.2.1
ibTableIndexindex N.B. Order changed in 900 and 840 SP2
Integer32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.1
ibObjectIB object namero
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.2
ibFirmwareVersionIB firmware versionro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.3
ibLIDIB port Local Identifier (LID)ro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.4
ibStateIB State which indicates the link state of the specified port: None - No state available Offline - The port is enabled but not linked up Online - The port is online and active Disabled - The port has been disabled, likely because the system is restoring memory from disk or preparing to psuoff.ro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.5
ibBoardGuidIB Board Global Unique IDro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.6
ibPortGuidIB Port Global Unique IDro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.7
ibSystemGuidIB System Global Unique IDro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.8
ibSpeedIB Link Speed indicates the specified port's link speed: Unknown - There is a reporting error. None - No link speed is available. 10Gb - Linked up in 10 Gigabit mode. 20Gb - Linked up in 20 Gigabit mode. 40Gb - Linked up in 40 Gigabit mode.ro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.9
ibBWBandwidth in MiB/sro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.10
ibReadBWRead Bandwidth in MiB/sro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.11
ibWriteBWWrite Bandwidth in MiB/sro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.12
ibIOPSIO's per secondro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.13
ibReadIOPSRead IO's per secondro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.14
ibWriteIOPSWrite IO's per secondro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.15
ibQueueDepthQueue depthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.16
ibReadQueueDepthRead Queue depthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.17
ibWriteQueueDepthWrite Queue depthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.18
ibReadAvgLatencyAverage SCSI read latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.19
ibReadMaxLatencyMaximum SCSI read latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.20
ibReadSampleLowSamples of SCSI read with latency <= 1msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.21
ibReadSampleMedSamples of SCSI read with latency in range (1ms, 10ms)ro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.22
ibReadSampleHighSamples of SCSI read with latency >= 10msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.23
ibWriteAvgLatencyAverage SCSI write latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.24
ibWriteMaxLatencyMaximum SCSI write latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.25
ibWriteSampleLowSamples of SCSI write with latency <= 1msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.26
ibWriteSampleMedSamples of SCSI write with latency in range (1ms, 10ms)ro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.27
ibWriteSampleHighSamples of SCSI write with latency >= 10msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.28
ibbs2k2k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.29
ibbs4k4k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.30
ibbs8k8k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.31
ibbs16k16k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.32
ibbs32k32k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.33
ibbs64k64k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.34
ibbs128k128k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.35
ibbs256k256k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.36
ibReadScsiCountScsi read countro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.37
ibWriteScsiCountScsi write countro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.38
ibReadScsiBytesScsi read bytesro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.39
ibWriteScsiBytesScsi write bytesro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.40
ibCorrMediaErrCorrectable media errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.41
ibUncorrMediaErrUncorrectable media errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.42
ibTimeTickTime ticksro
Unsigned32 UNITS "1/100th seconds"
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.43
ibalign512512 aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.44
ibalign1k1k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.45
ibalign2k2k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.46
ibalign4k4k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.47
ibalign8k8k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.48
ibalign16k16k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.49
ibalign32k32k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.50
ibalign64k64k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.51
ibRMWCountRead-Modify-Write Countro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.52
ibLinkDownLink Down Countro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.53
ibCRCErrCRC Errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.54
ibUnalignedReadsAligned Writesro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.55
ibUnalignedWritesUnaligned Writesro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.56
ibBounceReadsBounce readsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.57
ibBounceWritesBounce writesro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.2.1.58
iscsiTableiscsi info table
SEQUENCE OF ISCSITableEntry
.1.3.6.1.4.1.2.6.255.1.1.2.3
iscsiTableEntryiscsi table entry
ISCSITableEntry
.1.3.6.1.4.1.2.6.255.1.1.2.3.1
iscsiTableIndexindex N.B. Order changed in 900 and 840 SP2
Integer32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.1
iscsiObjectiscsi object namero
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.2
iscsiFirmwareVersioniscsi firmware versionro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.3
iscsiPortIDiscsi port IDro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.4
iscsiStateiscsi State which indicates the link state of the specified port: None - No state available No Light - Nothing is plugged into the iscsi port Offline - A device is plugged into the iscsi port, but the linkup procedure has not completed successfully Online - The port is online and functional from a link point of view Disabled - The port has been disabled, likely because the system is restoring memory from disk, or preparing to psuoff.ro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.5
iscsiSpeediscsi Link Speed indicates the specified port's link speed: Unknown - There is a reporting error, or no link speed is available. 1Gb - Linked up in 1 Gigabit mode. 2Gb - Linked up in 2 Gigabit mode. 4Gb - Linked up in 4 Gigabit mode. 8Gb - Linked up in 8 Gigabit mode.ro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.6
iscsiMACiscsi MAC Addressro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.7
iscsiIPv4iscsi IPv4 Addressro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.8
iscsiIPv4Maskiscsi IPv4 Address Maskro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.9
iscsiIPv4GWiscsi IPv4 Gatewayro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.10
iscsiIPv4Hostiscsi IPv4 Host Addressro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.11
iscsiDuplexDuplexro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.12
iscsiBWBandwidth in MiB/sro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.13
iscsiReadBWRead Bandwidth in MiB/sro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.14
iscsiWriteBWWrite Bandwidth in MiB/sro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.15
iscsiIOPSIO's per secondro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.16
iscsiReadIOPSRead IO's per secondro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.17
iscsiWriteIOPSWrite IO's per secondro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.18
iscsiQueueDepthQueue depthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.19
iscsiReadQueueDepthRead Queue depthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.20
iscsiWriteQueueDepthWrite Queue depthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.21
iscsiReadAvgLatencyAverage SCSI read latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.22
iscsiReadMaxLatencyMaximum SCSI read latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.23
iscsiReadSampleLowSamples of SCSI read with latency <= 1msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.24
iscsiReadSampleMedSamples of SCSI read with latency in range (1ms, 10ms)ro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.25
iscsiReadSampleHighSamples of SCSI read with latency >= 10msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.26
iscsiWriteAvgLatencyAverage SCSI write latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.27
iscsiWriteMaxLatencyMaximum SCSI write latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.28
iscsiWriteSampleLowSamples of SCSI write with latency <= 1msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.29
iscsiWriteSampleMedSamples of SCSI write with latency in range (1ms, 10ms)ro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.30
iscsiWriteSampleHighSamples of SCSI write with latency >= 10msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.31
iscsibs2k2k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.32
iscsibs4k4k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.33
iscsibs8k8k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.34
iscsibs16k16k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.35
iscsibs32k32k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.36
iscsibs64k64k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.37
iscsibs128k128k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.38
iscsibs256k256k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.39
iscsiReadScsiCountScsi read countro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.40
iscsiWriteScsiCountScsi write countro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.41
iscsiReadScsiBytesScsi read bytesro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.42
iscsiWriteScsiBytesScsi write bytesro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.43
iscsiCorrMediaErrCorrectable media errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.44
iscsiUncorrMediaErrUncorrectable media errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.45
iscsiTimeTickTime ticksro
Unsigned32 UNITS "1/100th seconds"
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.46
iscsialign512512 aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.47
iscsialign1k1k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.48
iscsialign2k2k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.49
iscsialign4k4k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.50
iscsialign8k8k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.51
iscsialign16k16k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.52
iscsialign32k32k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.53
iscsialign64k64k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.54
iscsiRMWCountRead-Modify-Write Countro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.55
iscsiLinkDownLink Down Countro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.56
iscsiCRCErrCRC Errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.57
iscsiTXFramesFrames Transmittedro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.58
iscsiRXFramesFrames Receivedro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.3.1.59
fcoeTableFibre channel over ethernet info table
SEQUENCE OF FCoETableEntry
.1.3.6.1.4.1.2.6.255.1.1.2.4
fcoeTableEntryFCoE table entry
FCoETableEntry
.1.3.6.1.4.1.2.6.255.1.1.2.4.1
fcoeTableIndexindex N.B. Order changed in 900 and 840 SP2
Integer32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.1
fcoeObjectFC object namero
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.2
fcoeFirmwareVersionFC firmware versionro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.3
fcoePortIDFC port IDro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.4
fcoeStateFC State which indicates the link state of the specified port: None - No state available No Light - Nothing is plugged into the fcoe port Offline - A device is plugged into the fcoe port, but the linkup procedure has not completed successfully Online - The port is online and functional from a link point of view Disabled - The port has been disabled, likely because the system is restoring memory from disk, or preparing to psuoff.ro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.5
fcoeWWNNFC node namero
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.6
fcoeWWPNFC port namero
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.7
fcoeTopoFC Topology indicates specified ports topologyro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.8
fcoeSpeedFC Link Speed indicates the specified port's link speedro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.9
fcoeVLANIDVLAN IDro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.10
fcoeFCFMACFCF MAC Addressro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.11
fcoeVPIMACVPI MAC Addressro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.12
fcoeBWBandwidth in MiB/sro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.13
fcoeReadBWRead Bandwidth in MiB/sro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.14
fcoeWriteBWWrite Bandwidth in MiB/sro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.15
fcoeIOPSIO's per secondro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.16
fcoeReadIOPSRead IO's per secondro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.17
fcoeWriteIOPSWrite IO's per secondro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.18
fcoeQueueDepthQueue depthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.19
fcoeReadQueueDepthRead Queue depthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.20
fcoeWriteQueueDepthWrite Queue depthro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.21
fcoeReadAvgLatencyAverage SCSI read latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.22
fcoeReadMaxLatencyMaximum SCSI read latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.23
fcoeReadSampleLowSamples of SCSI read with latency <= 1msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.24
fcoeReadSampleMedSamples of SCSI read with latency in range (1ms, 10ms)ro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.25
fcoeReadSampleHighSamples of SCSI read with latency >= 10msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.26
fcoeWriteAvgLatencyAverage SCSI write latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.27
fcoeWriteMaxLatencyMaximum SCSI write latencyro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.28
fcoeWriteSampleLowSamples of SCSI write with latency <= 1msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.29
fcoeWriteSampleMedSamples of SCSI write with latency in range (1ms, 10ms)ro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.30
fcoeWriteSampleHighSamples of SCSI write with latency >= 10msro
Unsigned32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.31
fcoebs2k2k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.32
fcoebs4k4k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.33
fcoebs8k8k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.34
fcoebs16k16k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.35
fcoebs32k32k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.36
fcoebs64k64k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.37
fcoebs128k128k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.38
fcoebs256k256k SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.39
fcoeReadScsiCountScsi read countro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.40
fcoeWriteScsiCountScsi write countro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.41
fcoeReadScsiBytesScsi read bytesro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.42
fcoeWriteScsiBytesScsi write bytesro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.43
fcoeCorrMediaErrCorrectable media errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.44
fcoeUncorrMediaErrUncorrectable media errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.45
fcoeTimeTickTime ticksro
Unsigned32 UNITS "1/100th seconds"
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.46
fcoealign512512 aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.47
fcoealign1k1k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.48
fcoealign2k2k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.49
fcoealign4k4k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.50
fcoealign8k8k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.51
fcoealign16k16k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.52
fcoealign32k32k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.53
fcoealign64k64k aligned SCSI commandsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.54
fcoeRMWCountRead-Modify-Write Countro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.55
fcoeLinkDownLink Down Countro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.56
fcoeCRCErrCRC Errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.57
fcoeTXFramesFrames Transmittedro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.58
fcoeRXFramesFrames Receivedro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.59
fcoeRXErrRX Errorsro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.60
fcoeXchgLookupErrNumber of invalid xchg records receivedro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.61
fcoeAbtsCntNumber of ABTS frames receivedro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.62
fcoeRscnCntNumber of SCNs receivedro
Counter32
.1.3.6.1.4.1.2.6.255.1.1.2.4.1.63
ibmflashFlashCards
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.255.1.1.3
flashcardTableFlashcard info table
SEQUENCE OF FlashcardTableEntry
.1.3.6.1.4.1.2.6.255.1.1.3.1
flashcardTableEntryFlashcard table entry
FlashcardTableEntry
.1.3.6.1.4.1.2.6.255.1.1.3.1.1
flashTableIndexindex
Integer32
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.1
flashObjectFlashcard object namero
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.2
flashSizeMiBFlashcard Sizero
Integer32 UNITS "MiB"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.6
flashTempGWTemperature - Gatewayro
FixedDiv10 UNITS "c"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.7
flashTempFPGA0Temperature FPGA0ro
FixedDiv10 UNITS "c"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.8
flashTempFPGA1Temperature FPGA1ro
FixedDiv10 UNITS "c"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.9
flashTempFPGA2Temperature FPGA2ro
FixedDiv10 UNITS "c"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.10
flashTempFPGA3Temperature FPGA3ro
FixedDiv10 UNITS "c"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.11
flashPowerPower usagero
Integer32 UNITS "w"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.12
flashHealthStateHealth Statero
Integer32
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.13
flashOverallHealthOverall Healthro
Integer32 UNITS "%"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.14
flashAvlRemapavailable_remapro
Integer32 UNITS "%"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.15
flashAvlBRPavailable_brpro
Integer32 UNITS "%"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.16
flashBlkWearAvgAverage Block Wearro
Integer32 UNITS "%"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.17
flashBlkWearMinMinimum Block Wearro
Integer32 UNITS "%"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.18
flashBlkWearMaxMaxiumum Block Wearro
Integer32 UNITS "%"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.19
flashRD512HostRead 512b Host countro
Counter64 UNITS "sectors"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.20
flashRD512XorRead 512b XOR countro
Counter64 UNITS "sectors"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.21
flashWR512HostWrite 512b Host countro
Counter64 UNITS "sectors"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.22
flashWR512XorWrite 512b XOR countro
Counter64 UNITS "sectors"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.23
flashRMWRead-Modify-Write countro
Counter64 UNITS "sectors"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.24
flashCacheHitsCache hitsro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.25
flashRDCorSuccRead Cor Successro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.26
flashRDCorFailRead Cor Failro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.27
flashRDRtyP1Read Retry Phase 1roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.28
flashRDRtyP2Read Retry Phase 2roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.29
flashRDRtyP3Read Retry Phase 3roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.30
flashRDRtyP4Read Retry Phase 4roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.31
flashRDRtyP5Read Retry Phase 5roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.32
flashRdRtyFailRead Retry Failroobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.33
flashRDAccum8kRead Accum 8kroobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.34
flashRDAccumSftRead Accum Softro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.35
flashRDAccumHrdRead Accum Hardro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.36
flashAccumSuccAccum Successro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.37
flashAccumFailAccum Failro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.38
flashRDLimWrnRead Limit Warningro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.39
flashRDLimCritRead Limit Criticalro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.40
flashRDScb8kRead Scrub 8kroobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.41
flashRDScbSftRead Scrub Softro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.42
flashRDScbHrdRead Scrub Hardro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.43
flashRDSwpStrpRead Sweep Striperoobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.44
flashRDSwpPgeRead Sweep Pageroobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.45
flashMvRD4kMove Read 4kro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.46
flashMvRDHrdMove Read Hardro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.47
flashMvWR4kMove Write 4kro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.48
flashDtWR4kFlash Data Write 4kroobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.49
flashXorWR8kFlash XOR Write 8kroobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.50
flashWRErrFlash Write Errorro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.51
flashEraseFlash Erasero
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.52
flashEraseErrFlash Erase Errorsro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.53
flashPeCycMaxMaximum PE Cyclero
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.54
flashPeCycMinMimimum PE Cyclero
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.55
flashPeCycMaxDevPE Cycle Max Devro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.56
flashMinRtuMimimum RTUro
Counter64 UNITS "blocks"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.57
flashOOBWarnOut of blocks warningsro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.58
flashBadBlksBad Blocksro
Counter64 UNITS "blocks"
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.59
flashBusCRCErrBus CRC Errorsro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.60
flashRdRtyLn0Read Retry ln 0roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.61
flashRdRtyLn1Read Retry ln 1roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.62
flashRdRtyLn2Read Retry ln 2roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.63
flashRdRtyLn3Read Retry ln 3roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.64
flashRdRtyLn4Read Retry ln 4roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.65
flashRdRtyLn5Read Retry ln 5roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.66
flashRdRtyLn6Read Retry ln 6roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.67
flashRdRtyLn7Read Retry ln 7roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.68
flashRdRtyLn8Read Retry ln 8roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.69
flashRdRtyLn9Read Retry ln 9roobsolete
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.70
flashWrTotalFl Wr Totalro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.71
flashHstWrnPrioHost Wrong Priorityro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.72
flashRecircWrgPrioRecirc Wrong Priorityro
Counter64
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.73
flashCoalesceCoalescero
Integer32
.1.3.6.1.4.1.2.6.255.1.1.3.1.1.74
ibmflashBatteries
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.255.1.1.4
batteryTableBattery values and states table
SEQUENCE OF BatteryTableEntry
.1.3.6.1.4.1.2.6.255.1.1.4.10
batteryTableEntryBattery table entry
BatteryTableEntry
.1.3.6.1.4.1.2.6.255.1.1.4.10.1
batteryTableIndexindex
Integer32
.1.3.6.1.4.1.2.6.255.1.1.4.10.1.1
batteryObjectcontaining objectro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.4.10.1.2
batteryNamenamero
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.4.10.1.3
batteryCell1Battery Cell #1ro
Integer32 UNITS "mV"
.1.3.6.1.4.1.2.6.255.1.1.4.10.1.4
batteryCell2Battery Cell #2ro
Integer32 UNITS "mV"
.1.3.6.1.4.1.2.6.255.1.1.4.10.1.5
batteryCell3Battery Cell #3ro
Integer32 UNITS "mV"
.1.3.6.1.4.1.2.6.255.1.1.4.10.1.6
batteryTotalTotal Batteryro
Integer32 UNITS "mV"
.1.3.6.1.4.1.2.6.255.1.1.4.10.1.7
batteryChgCurrBattery Charging Currentro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.4.10.1.8
batteryRmngCapBattery Capacity Remainingro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.4.10.1.9
batteryFullCapBattery Capacity Fullro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.4.10.1.10
ibmflashPSUs
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.255.1.1.5
psuTablePower values and states table
SEQUENCE OF PowerTableEntry
.1.3.6.1.4.1.2.6.255.1.1.5.10
psuTableEntryPower table entry
PowerTableEntry
.1.3.6.1.4.1.2.6.255.1.1.5.10.1
psuTableIndexindex
Integer32
.1.3.6.1.4.1.2.6.255.1.1.5.10.1.1
psuObjectcontaining objectro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.5.10.1.2
psuCommErrCommunications error. 0 success, 1 errorro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.5.10.1.3
psuACGoodAC is good. 0 success, 1 errorro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.5.10.1.4
psuDCGoodDC is good. 0 success, 1 errorro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.5.10.1.5
psuFanPSU Fan RPMro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.5.10.1.6
ibmflashFans
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.255.1.1.6
fanTableFan values and states table
SEQUENCE OF FanTableEntry
.1.3.6.1.4.1.2.6.255.1.1.6.10
fanTableEntryFan table entry
FanTableEntry
.1.3.6.1.4.1.2.6.255.1.1.6.10.1
fanTableIndexindex N.B. Order changed in 900 and 840 SP2
Integer32
.1.3.6.1.4.1.2.6.255.1.1.6.10.1.1
fanObjectcontaining objectro
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.6.10.1.2
fanNamenamero
DisplayString
.1.3.6.1.4.1.2.6.255.1.1.6.10.1.3
fanPWMFan PWMro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.6.10.1.4
fanTempFan Temperaturero
Integer32
.1.3.6.1.4.1.2.6.255.1.1.6.10.1.5
fan0Fan #0 %ro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.6.10.1.6
fan1Fan #1 %ro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.6.10.1.7
fan2Fan #2 %ro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.6.10.1.8
fan3Fan #3 %ro
Integer32
.1.3.6.1.4.1.2.6.255.1.1.6.10.1.9
ibmflashNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.255.1.1.7
flashMACHIBM FlashSystem machine typero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.1
flashSERIIBM FlashSystem serial numberro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.2
flashERRIIBM FlashSystem error IDro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.3
flashERRCIBM FlashSystem error codero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.4
flashSWVEIBM FlashSystem software versionro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.5
flashFRUPIBM FlashSystem FRU part numberro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.6
flashCLUSIBM FlashSystem cluster namero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.7
flashNODEIBM FlashSystem node identifierro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.8
flashERRSIBM FlashSystem error sequence numberro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.9
flashTIMEIBM FlashSystem last error time stampro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.10
flashOBJTIBM FlashSystem object typero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.11
flashOBJIIBM FlashSystem object IDro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.12
flashADD1IBM FlashSystem Additional dataro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.13
flashADD2IBM FlashSystem Additional dataro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.14
flashCOPYIBM FlashSystem Copy IDro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.15
flashMPNOIBM FlashSystem Machine Part Numberro
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.16
flashOBJNIBM FlashSystem object namero
SnmpAdminString (SNMP-FRAMEWORK-MIB)
.1.3.6.1.4.1.2.6.255.1.1.7.17
ibmflashConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.255.1.2
ibmflashCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.255.1.2.1
ibmflashComplianceThe compliance statement for IBM-MIB entities which implement this MIB
Unknown
.1.3.6.1.4.1.2.6.255.1.2.1.1
ibmflashComplianceObsoleteObsolete entries within this IBM-MIBobsolete
Unknown
.1.3.6.1.4.1.2.6.255.1.2.1.2
ibmflashGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.255.1.2.2
ibmflashRequiredObjectsGroupThe objects defined in this MIB module that MUST be implemented by a compliant implementation.
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.1
ibmflashNotifGroupAll notifications defined in this MIB module MUST be implemented by a compliant implementation.
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.2
ibmflashSystemGroupSystem variables conformance group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.3
ibmflashSystemEventGroupSystem Event Table conformance Group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.11
ibmflashSystemDriveGroupSystem Drive Table conformance Group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.12
ibmflashSystemArrayGroupSystem Array Table conformance Group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.13
ibmflashSystemVDiskGroupSystem VDisk Table conformance Group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.14
ibmflashSystemNodeGroupSystem VDisk Table conformance Group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.15
ibmflashFlashcardGroupFlashcard variables conformance group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.20
ibmflashBatteryGroupBattery Table variables conformance group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.21
ibmflashPSUGroupPSU variables conformance group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.22
ibmflashFanGroupFan Table variables conformance group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.23
ibmflashFCGroupFC Table variables conformance group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.31
ibmflashIBGroupIB Table variables conformance group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.32
ibmflashiscsiGroupiscsi Table variables conformance group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.33
ibmflashFCOEGroupFCoE Table variables conformance group
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.34
ibmflashFlashcardObsoleteGroupFlashcard variables which have been made obsolete with the update to FlashSystem 900 and FlashSystem 840 SP2obsolete
Unknown
.1.3.6.1.4.1.2.6.255.1.2.2.120
IBM-MIB - SNMP MIB Reference | MIBs Explorer