IBM-Director-Alert-MIB
AI MIB Summary
The IBM-Director-Alert-MIB defines the managed objects required by IBM Director's Event Action Plan Builder to monitor system alerts and trigger automated remediation workflows. It facilitates the transmission of specific hardware and software event notifications from IBM servers to the central management console for policy-based response execution.
This MIB is for use with the Event Action Plan Builder of IBM Director.
Main OID:
directorTraps.1.3.6.1.4.1.2.6.159.201
555
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
555 total| Object Name |
|---|
ibmProd OBJECT IDENTIFIER .1.3.6.1.4.1.2.6 |
director OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159 |
directorTrapsThis MIB is for use with the Event Action Plan Builder of IBM Director. MODULE-IDENTITY .1.3.6.1.4.1.2.6.159.201 |
directorFamily OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1 |
topology OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.1 |
onlineThe managed object's state has changed to online. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.1.1 |
offlineThe managed object's state has changed to offline. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.1.2 |
createThe managed object has been created. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.1.3 |
changeThe managed object has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.1.4 |
destroyThe managed object has been destroyed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.1.5 |
directorAgent OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.2 |
processMonitorThe process monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.1 |
cpuMonitors OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.2.2 |
cpuUtilizationThe CPU utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.1 |
processCountThe process count monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.2 |
cpu0UtilizationThe CPU 0 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.3 |
cpu1UtilizationThe CPU 1 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.4 |
cpu2UtilizationThe CPU 2 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.5 |
cpu3UtilizationThe CPU 3 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.6 |
cpu4UtilizationThe CPU 4 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.7 |
cpu5UtilizationThe CPU 5 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.8 |
cpu6UtilizationThe CPU 6 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.9 |
cpu7UtilizationThe CPU 7 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.10 |
cpu8UtilizationThe CPU 8 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.11 |
cpu9UtilizationThe CPU 9 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.12 |
cpu10UtilizationThe CPU 10 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.13 |
cpu11UtilizationThe CPU 11 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.14 |
cpu12UtilizationThe CPU 12 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.15 |
cpu13UtilizationThe CPU 13 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.16 |
cpu14UtilizationThe CPU 14 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.17 |
cpu15UtilizationThe CPU 15 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.18 |
cpu16UtilizationThe CPU 16 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.19 |
cpu17UtilizationThe CPU 17 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.20 |
cpu18UtilizationThe CPU 18 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.21 |
cpu19UtilizationThe CPU 19 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.22 |
cpu20UtilizationThe CPU 20 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.23 |
cpu21UtilizationThe CPU 21 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.24 |
cpu22UtilizationThe CPU 22 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.25 |
cpu23UtilizationThe CPU 23 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.26 |
cpu24UtilizationThe CPU 24 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.27 |
cpu25UtilizationThe CPU 25 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.28 |
cpu26UtilizationThe CPU 26 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.29 |
cpu27UtilizationThe CPU 27 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.30 |
cpu28UtilizationThe CPU 28 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.31 |
cpu29UtilizationThe CPU 29 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.32 |
cpu30UtilizationThe CPU 30 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.33 |
cpu31UtilizationThe CPU 31 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.34 |
cpu32UtilizationThe CPU 32 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.35 |
cpu33UtilizationThe CPU 33 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.36 |
cpu34UtilizationThe CPU 34 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.37 |
cpu35UtilizationThe CPU 35 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.38 |
cpu36UtilizationThe CPU 36 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.39 |
cpu37UtilizationThe CPU 37 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.40 |
cpu38UtilizationThe CPU 38 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.41 |
cpu39UtilizationThe CPU 39 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.42 |
cpu40UtilizationThe CPU 40 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.43 |
cpu41UtilizationThe CPU 41 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.44 |
cpu42UtilizationThe CPU 42 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.45 |
cpu43UtilizationThe CPU 43 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.46 |
cpu44UtilizationThe CPU 44 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.47 |
cpu45UtilizationThe CPU 45 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.48 |
cpu46UtilizationThe CPU 46 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.49 |
cpu47UtilizationThe CPU 47 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.50 |
cpu48UtilizationThe CPU 48 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.51 |
cpu49UtilizationThe CPU 49 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.52 |
cpu50UtilizationThe CPU 50 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.53 |
cpu51UtilizationThe CPU 51 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.54 |
cpu52UtilizationThe CPU 52 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.55 |
cpu53UtilizationThe CPU 53 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.56 |
cpu54UtilizationThe CPU 54 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.57 |
cpu55UtilizationThe CPU 55 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.58 |
cpu56UtilizationThe CPU 56 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.59 |
cpu57UtilizationThe CPU 57 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.60 |
cpu58UtilizationThe CPU 58 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.61 |
cpu59UtilizationThe CPU 59 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.62 |
cpu60UtilizationThe CPU 60 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.63 |
cpu61UtilizationThe CPU 61 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.64 |
cpu62UtilizationThe CPU 62 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.65 |
cpu63UtilizationThe CPU 63 utilization monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.2.66 |
diskMonitors OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.2.3 |
driveSpaceUsedThe drive space used monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.3.1 |
driveSpaceUsedPercentThe percentage of drive space used monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.3.2 |
driveSpaceRemainingThe drive space remaining monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.3.3 |
driveWorkloadThe drive workload monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.3.4 |
memoryMonitors OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.2.4 |
lockedMemoryThe locked memory monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.4.1 |
memoryUsageThe memory usage monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.4.2 |
nicMonitors OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.2.5 |
ntPerfMonitors OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.2.6 |
totalPrivilegedTimePercentThe percentage of total privileged time monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.6.1 |
fileReadOperationsPerSecThe files read per second monitor threshold has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.6.2 |
tcpipMonitors OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.2.7 |
udpPacketsSentPerSecA threshold event for the number of UDP packets sent per second. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.7.1 |
udpPacketsReceivedPerSecA threshold event for the number of UDP packets received per second. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.7.2 |
ipPacketsSentPerSecA threshold event for the number of IP packets sent per second. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.7.3 |
ipPacketsReceivedPerSecA threshold event for the number of IP packets received per second. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.7.4 |
ipErrorPacketsReceivedPerSecA threshold event for the number of IP packets received with errors per second. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.7.5 |
tcpConnectionsA threshold event for the number of TCP connections. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.2.7.6 |
monitorEventDetails OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.2.8 |
actualValueThe actual value of the monitor.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.2.8.1 |
durationThe duration of this monitor.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.1.2.8.2 |
monitorResourceThe monitor resource.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.2.8.3 |
thresholdNameThe name of the monitor threshold.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.2.8.4 |
thresholdValueThe value of the monitor threshold.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.2.8.5 |
test OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.3 |
actionThe test action event. An internally generated event for the purpose of testing the action configuration. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.3.1 |
console OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.4 |
consoleEventDetails OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.4.1 |
userIDThe console user ID.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.4.1.1 |
addressThe console address.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.4.1.2 |
userNameThe console username.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.4.1.3 |
userDescriptionThe console username's description.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.4.1.4 |
userLocaleThe console user's locale.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.4.1.5 |
logonFailure OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.4.2 |
badPasswordWhen attempting to logon to the console, a bad password was used. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.4.2.1 |
badUserIDWhen attempting to logon to the console, a bad user ID was used. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.4.2.2 |
disabledUserIDWhen attempting to logon to the console, a disabled user ID was used. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.4.2.3 |
downlevelConsoleWhen attempting to logon to the console, a downlevel console was used. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.4.2.4 |
expiredPasswordWhen attempting to logon to the console, an expired password was used. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.4.2.5 |
tooManyActiveIDsWhen attempting to logon to the console, too many IDs were active. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.4.2.6 |
tooManyActiveLogonsWhen attempting to logon to the console, too many logons were active. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.4.2.7 |
uplevelConsoleWhen attempting to logon to the console, an uplevel console was used. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.4.2.8 |
logoffA user has logged off the console. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.4.3 |
logonA user has logged on the console. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.4.4 |
inventory OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.5 |
collection OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.5.2 |
authorizationFailureInventory collection failed due to an authorization failure. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.5.2.1 |
communicationErrorInventory collection failed due to a communication error. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.5.2.2 |
generalFailureInventory collection failed due to a general failure. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.5.2.3 |
hardwareFailureInventory collection failed due to a hardware failure. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.5.2.4 |
noDataInventory collection returned no data. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.5.2.5 |
softwareFailureInventory collection of software failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.5.2.6 |
successfulInventory collection was successful. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.5.2.7 |
timeoutFailureInventory collection timed out. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.5.2.8 |
hardwareMonitor OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.5.3 |
rowAddedInventory collection timed out. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.5.3.1 |
rowChangedInventory collection timed out. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.5.3.2 |
rowRemovedInventory collection timed out. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.5.3.3 |
scheduler OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.6 |
schedulerEventDetails OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.6.1 |
jobIDThe job's ID.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.6.1.1 |
jobActivationTimeThe job's activation time.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.6.1.2 |
clientStatusThe client status value.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.6.1.3 |
jobCurrentTaskIDThe job's current task ID.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.6.1.4 |
jobCurrentSubtaskIDThe job's current subtask ID.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.6.1.5 |
jobCurrentTaskNameThe job's current task name.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.6.1.6 |
job OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.6.2 |
jobSuccessThe job successfully completed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.6.2.1 |
jobFailureThe job successfully completed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.6.2.2 |
client OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.6.3 |
clientSuccessThe client successfully completed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.6.3.1 |
clientFailureThe client successfully completed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.6.3.2 |
updateManager OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.7 |
updateManagerEventDetails OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.1.7.1 |
profileNameThe update manager profile name.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.7.1.1 |
severityThe severity of the error.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.7.1.2 |
errorCodeThe error code value of the failure.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.1.7.1.3 |
newUpdatesDownloadedThe new updates have downloaded successfully. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.7.2 |
profileModifiedThe update profile has been modified. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.7.3 |
failedDownloadThe updates have failed to download. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.1.7.4 |
generalEventThis is a IBM Director event converted into an SNMP trap. This trap is only used for events with no mapping. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.2 |
cimFamily OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.3 |
windowsNTEventLog OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.3.1 |
windowsNTEventLogEventDetails OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.3.1.1 |
categoryThe Windows Event Log category.ro Integer32 .1.3.6.1.4.1.2.6.159.201.3.1.1.1 |
categoryStringThe Windows Event Log category string.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.1.1.2 |
computerNameThe computer name of the Windows Event Log event.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.1.1.3 |
dataThe Windows Event Log data for the event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.3.1.1.4 |
eventLogCodeThe Windows Event Log numeric event ID.ro Integer32 .1.3.6.1.4.1.2.6.159.201.3.1.1.5 |
eventLogIdentifierThe Windows Event Log numeric event identifier.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.3.1.1.6 |
eventLogTypeThe Windows Event Log numeric event type.ro Integer32 .1.3.6.1.4.1.2.6.159.201.3.1.1.7 |
insertionStringsThe Windows Event Log insertion strings.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.1.1.8 |
logFileThe Windows Event Log file name.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.1.1.9 |
messageThe Windows Event Log message string.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.1.1.10 |
recordNumberThe Windows Event Log record number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.3.1.1.11 |
sourceNameThe Windows Event Log source name.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.1.1.12 |
typeThe Windows Event Log type.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.1.1.13 |
userThe Windows Event Log user.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.1.1.14 |
applicationLogThe Windows NT application event log has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.3.1.2 |
securityLogThe Windows NT application security log has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.3.1.3 |
systemLogThe Windows NT application system log has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.3.1.4 |
windowsNTService OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.3.2 |
windowsNTServiceEventDetails OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.3.2.1 |
acceptPauseWhether this service accepts the pause state change.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.3.2.1.1 |
acceptStopWhether this service accepts the stop state change.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.3.2.1.2 |
captionThe caption string for this service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.3 |
checkPointThe service's check point.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.3.2.1.4 |
creationClassNameThe creation class name for the service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.5 |
serviceDescriptionThe description of the service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.6 |
desktopInteractWhether the service interacts with the desktop.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.3.2.1.7 |
displayNameThe displayable name for the service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.8 |
errorControlThe error control value for the service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.9 |
exitCodeThe exit code of the process for the service.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.3.2.1.10 |
nameThe name of the service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.11 |
pathNameThe path name for the service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.12 |
processIdThe process ID of the running service.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.3.2.1.13 |
serviceSpecificExitCodeThe specific exit code for the service.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.3.2.1.14 |
serviceTypeThe type of service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.15 |
startModeThe start mode for the service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.16 |
startNameThe start name for the service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.17 |
startedWhether this service has started.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.3.2.1.18 |
serviceStateThe state of the service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.19 |
statusThe status of the service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.20 |
systemCreationClassNameThe system creation class name for the service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.21 |
systemNameThe system name for the service.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.2.1.22 |
tagIdThe tag ID of the service.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.3.2.1.23 |
waitHintThe value of the wait hint for the service.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.3.2.1.24 |
startedServiceA Windows NT service has started. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.3.2.2 |
stoppedServiceA Windows NT service has stopped. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.3.2.3 |
windowsRegistry OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.3.3 |
windowsRegistryEventDetails OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.3.3.1 |
hiveThe Windows Registry hive for this event.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.3.1.1 |
rootPathThe Windows Registry root path for this event.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.3.1.2 |
securityDescriptorThe Windows Registry security descriptor for this event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.3.3.1.3 |
timeCreatedThe time this item was created in the Windows Registry.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.3.1.4 |
softwareTreeChangedThe Windows software tree section of the registry has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.3.3.2 |
systemTreeChangedThe Windows system tree section of the registry has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.3.3.3 |
certificate OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.3.4 |
certificateEventDetails OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.3.4.1 |
notValidAfterThe certificate is not valid after the given time.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.4.1.1 |
notValidBeforeThe certificate is not valid after the given time.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.4.1.2 |
expiringInHoursThe certificate is expiring in the given hours.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.4.1.3 |
certificateExpireThe certificate is about to expire. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.3.4.2 |
storage OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.3.5 |
storageEventDetails OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.3.5.1 |
classnameThe classname for the storage device.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.5.1.1 |
objectPathThe object path of the storage device.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.5.1.2 |
operationalStatusThe operational status of the storage device.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.3.5.1.3 |
array OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.3.5.2 |
storageAlertA storage array event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.3.5.2.1 |
storageOperationalStatusThe storage operational status event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.3.5.2.1 |
mpaFamily OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4 |
mpaEventDetails OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.1 |
alertCodeThe alert code.ro Integer32 .1.3.6.1.4.1.2.6.159.201.4.1.1 |
busIdThe bus ID.ro Integer32 .1.3.6.1.4.1.2.6.159.201.4.1.2 |
componentIdThe component ID.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.4.1.3 |
firmwareCodeThe firmware identification code.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.4.1.4 |
ipAddress1The first IP address.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.4.1.5 |
ipAddress2The second IP address.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.4.1.6 |
issueThe issue for the event.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.4.1.7 |
powerDomainThe domain of the power supply.ro Integer32 .1.3.6.1.4.1.2.6.159.201.4.1.8 |
reasonThe reason for the event.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.4.1.9 |
scsiIdThe ID of the SCSI device.ro Integer32 .1.3.6.1.4.1.2.6.159.201.4.1.10 |
sideThe side in which the event occured.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.4.1.11 |
newStateThe new state.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.4.1.12 |
temperatureSensorThe current temperature.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.4.1.13 |
thresholdThe threshold for the event.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.4.1.14 |
universalUniqueIdThe universal unique ID.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.4.1.15 |
senderUniversalUniqueIdThe universal unique ID of the sender.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.4.1.16 |
sourceUniversalUniqueIdThe universal unique ID of the source.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.4.1.17 |
unitNumberThe unit number.ro Integer32 .1.3.6.1.4.1.2.6.159.201.4.1.18 |
voltageSensorThe voltage sensor.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.201.4.1.19 |
component OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2 |
bladeServer OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.1 |
coD OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.1.1 |
codEnabledThe CoD has been enabled. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.1.1.1 |
bladeServerCommunicationCommunication with a blade has been established. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.1.2 |
bladeServerInsertedA blade has been inserted. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.1.3 |
bladeServerRemovedA blade has been removed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.1.4 |
bus OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.2 |
busCommunicationCommunication with a bus has been established. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.2.1 |
chassis OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.3 |
chassisConfigurationThe blade chassis configuration has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.3.1 |
chassisFailedThe blade chassis has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.3.2 |
dasd OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.4 |
dasdFaileda direct access storage device has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.4.1 |
dasdInsertedA direct access storage device has been inserted. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.4.2 |
dasdRemovedA direct access storage device has been removed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.4.3 |
memory OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.5 |
memoryFailedSome memory has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.5.1 |
componentFan OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.6 |
componentFanFailedA fan has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.6.1 |
componentFanInsertedA fan has been inserted. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.6.2 |
componentFanPfaThe fan component has generated a PFA. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.6.3 |
componentFanRemovedA fan has been removed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.6.4 |
hardwareInformation OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.7 |
hardwareCrashDump OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.7.1 |
hardwareCrashDumpAbortedA hardware crash dump was aborted. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.7.1.1 |
hardwareCrashDumpCompletedA hardware crash dump has completed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.7.1.2 |
hardwareCrashDumpInitiatedA hardware crash dump has been initiated. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.7.1.3 |
ioModule OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.8 |
ioModuleConfigurationAn I/O module's configuration has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.8.1 |
ioModuleFailedAn I/O module has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.8.2 |
ioModuleInsertedAn I/O module has been inserted. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.8.3 |
ioModulePostAn I/O module has past POST. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.8.4 |
ioModulePower OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.8.5 |
ioModulePowerOffAn I/O module has been powered off. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.8.5.1 |
ioModulePowerOnAn I/O module has been powered on. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.8.5.2 |
ioModuleRedundancyAn I/O module is a redundancy. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.8.6 |
ioModuleRemovedAn I/O module has been removed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.8.7 |
kvm OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.9 |
kvmOwnerThe KVM owner has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.9.1 |
osImage OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.10 |
osImageCrashDump OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.10.1 |
osImageCrashDumpAbortedThe operating system image crash dump was aborted. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.10.1.1 |
osImageCrashDumpCompletedThe operating system image crash dump has completed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.10.1.2 |
osImageCrashDumpInitiatedThe operating system image crash dump has been initiated. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.10.1.3 |
componentPfaA component has generated a PFA. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.11 |
powerSubsystem OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.12 |
powerSubsystemLowFuelThe power subsystem indicates low fuel. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.12.1 |
powerSubsystemOverCurrentThe power subsystem indicates over current. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.12.2 |
powerSubsystemOverPowerThe power subsystem indicates over power. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.12.3 |
powerSubsystemRedundancyThe power subsystem indicates a redundancy. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.12.4 |
powerSupply OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.13 |
powerSupplyFailedA power supply has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.13.1 |
powerSupplyInsertedA power supply has been inserted. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.13.2 |
powerSupplyRemovedA power supply has been removed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.13.3 |
server OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.14 |
serverPower OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.14.1 |
serverPowerOffThe server has powered off. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.14.1.1 |
serverPowerOnThe server has powered on. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.14.1.2 |
serverPowerStateThe server's power state has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.14.2 |
serviceProcessor OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.15 |
serviceProcessorActiveA service processor is now active. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.15.1 |
serviceProcessorConfigurationA service processor configuration has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.15.2 |
serviceProcessorInsertedA service processor has been inserted. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.15.3 |
serviceProcessorLogA service processor has generated a log. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.15.4 |
serviceProcessorNetworkStackA service processor network stack has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.15.5 |
serviceProcessorRedundancyA service processor detected a redundancy. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.15.6 |
serviceProcessorRemoteLoginA remove login was made into the service processor. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.15.7 |
serviceProcessorRemovedA service processor has been removed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.15.8 |
serviceProcessorRestartA service processor has been restarted. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.15.9 |
serviceProcessorTestA service processor test was issued. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.15.10 |
smpExpansionModule OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.16 |
smpExpansionModuleDisabledAn SMP expansion module has been disabled. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.16.1 |
usb OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.17 |
usbInsertedA USB device has been inserted. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.17.1 |
usbOwnerA USB device owner has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.17.2 |
usbRemovedA USB device has been removed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.17.3 |
vrm OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.2.18 |
vrmFailedThe VRM has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.2.18.1 |
critical OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3 |
hardDiskDriveA hard disk drive is in critical state. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.1 |
multipleFanFailureMultiple fans have failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.2 |
powerFailure OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.3 |
powerFailureEpowThere was a critical power failure as a result of an EPOW. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.3.1 |
powerFailureFailedThere was a critical power failure as a result of something failing. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.3.2 |
powerFailureRemovedThere was a critical power failure as a result of something removed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.3.3 |
criticalTamperTampering with the system has caused a critical state. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.4 |
criticalTemperature OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.5 |
criticalTemperatureAmbientThe ambient temperature is in a critical state. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.5.1 |
criticalTemperaturePciThe PCI temperature is in a critical state. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.5.2 |
criticalTemperaturePlanarThe planar temperature is in a critical state. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.5.3 |
criticalVoltage OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.6 |
criticalTwelveVolts OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.6.1 |
criticalTwelveVoltsHighA critical state of 12V high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.1.1 |
criticalTwelveVoltsLowA critical state of 12V low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.1.2 |
criticalTwelveVoltsFaultAA critical state of 12V fault A has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.2 |
criticalTwelveVoltsFaultBA critical state of 12V fault B has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.3 |
criticalTwelveVoltsFaultCA critical state of 12V fault C has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.4 |
criticalTwelveVoltsFaultDA critical state of 12V fault D has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.5 |
criticalOneVolt OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.6.6 |
criticalOneVoltHighA critical state of 1V high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.6.1 |
criticalOneVoltLowA critical state of 1V low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.6.2 |
criticalTwoVolts OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.6.7 |
criticalTwoVoltsHighA critical state of 2V high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.7.1 |
criticalTwoVoltsLowA critical state of 2V low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.7.2 |
criticalThreeVolts OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.6.8 |
criticalThreeVoltsHighA critical state of 3V high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.8.1 |
criticalThreeVoltsLowA critical state of 3V low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.8.2 |
criticalThreeVoltsPci OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.6.9 |
criticalThreeVoltsPciHighA critical state of 3V high has been detected for the PCI. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.9.1 |
criticalThreeVoltsPciLowA critical state of 3V low has been detected for the PCI. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.9.2 |
criticalThreeVoltsStandby OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.6.10 |
criticalThreeVoltsStandbyHighA critical state of 3V standby high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.10.1 |
criticalThreeVoltsStandbyLowA critical state of 3V standby low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.10.2 |
criticalFiveVolts OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.6.11 |
criticalFiveVoltsHighA critical state of 5V high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.11.1 |
criticalFiveVoltsLowA critical state of 5V low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.11.2 |
criticalFiveVoltsFault OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.6.12 |
criticalFiveVoltsFaultHighA critical state of 5V fault high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.12.1 |
criticalFiveVoltsFaultLowA critical state of 5V fault low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.12.2 |
criticalFiveVoltsPci OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.6.13 |
criticalFiveVoltsPciHighA critical state of 5V high has been detected for the PCI. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.13.1 |
criticalFiveVoltsPciLowA critical state of 5V low has been detected for the PCI. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.13.2 |
criticalFiveVoltsStandby OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.6.14 |
criticalFiveVoltsStandbyHighA critical state of 5V standby high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.14.1 |
criticalFiveVoltsStandbyLowA critical state of 5V standby low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.14.2 |
criticalNTwelveVolts OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.3.6.15 |
criticalNTwelveVoltsHighA critical state of negative 12V high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.15.1 |
criticalNTwelveVoltsLowA critical state of negative 12V low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.6.15.2 |
voltageRegulatorModuleFailureThe voltage regulator module has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.3.7 |
deployment OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.4 |
deploymentBootDeployment has generated a boot event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.4.1 |
deploymentLoaderDeployment has generated a loader event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.4.2 |
deploymentOsDeployment has generated an operating system event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.4.3 |
deploymentPostDeployment has generated a POST event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.4.4 |
environmental OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.5 |
environmentalTemperatureThe environmental temperature has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.5.1 |
environmentalVoltageThe environmental voltage has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.5.2 |
nonCritical OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6 |
nonCriticalFan OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6.1 |
nonCriticalFanRemovedA fan has been removed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.1.1 |
redundantPowerThe system is now running on redundant power. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.2 |
singleFanFailureA single fan has failed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.3 |
nonCriticalTemperature OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6.4 |
nonCriticalTemperatureAmbientThe ambient temperature is in a non critical state. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.4.1 |
nonCriticalTemperaturePciThe PCI temperature is in a non critical state. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.4.2 |
nonCriticalTemperaturePlanarThe planar temperature is in a non critical state. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.4.3 |
nonCriticalVoltage OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6.5 |
nonCriticalTwelveVolts OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6.5.1 |
nonCriticalTwelveVoltsHighA non-critical state of 12V high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.1.1 |
nonCriticalTwelveVoltsLowA non-critical state of 12V low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.1.2 |
nonCriticalOneVolt OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6.5.2 |
nonCriticalOneVoltHighA non-critical state of 1V high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.2.1 |
nonCriticalOneVoltLowA non-critical state of 1V low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.2.2 |
nonCriticalTwoVolts OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6.5.3 |
nonCriticalTwoVoltsHighA non-critical state of 2V high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.3.1 |
nonCriticalTwoVoltsLowA non-critical state of 2V low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.3.2 |
nonCriticalThreeVolts OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6.5.4 |
nonCriticalThreeVoltsHighA non-critical state of 3V high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.4.1 |
nonCriticalThreeVoltsLowA non-critical state of 3V low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.4.2 |
nonCriticalThreeVoltsPci OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6.5.5 |
nonCriticalThreeVoltsPciHighA non-critical state of 3V high has been detected for the PCI. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.5.1 |
nonCriticalThreeVoltsPciLowA non-critical state of 3V low has been detected for the PCI. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.5.2 |
nonCriticalThreeVoltsStandby OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6.5.6 |
nonCriticalThreeVoltsStandbyHighA non-critical state of 3V standby high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.6.1 |
nonCriticalThreeVoltsStandbyLowA non-critical state of 3V standby low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.6.2 |
nonCriticalFiveVolts OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6.5.7 |
nonCriticalFiveVoltsHighA non-critical state of 5V high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.7.1 |
nonCriticalFiveVoltsLowA non-critical state of 5V low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.7.2 |
nonCriticalFiveVoltsPci OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6.5.8 |
nonCriticalFiveVoltsPciHighA non-critical state of 5V high has been detected for the PCI. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.8.1 |
nonCriticalFiveVoltsPciLowA non-critical state of 5V low has been detected for the PCI. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.8.2 |
nonCriticalFiveVoltsStandby OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6.5.9 |
nonCriticalFiveVoltsStandbyHighA non-critical state of 5V standby high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.9.1 |
nonCriticalFiveVoltsStandbyLowA non-critical state of 5V standby low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.9.2 |
nonCriticalNTwelveVolts OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.6.5.10 |
nonCriticalNTwelveVoltsHighA non-critical state of negative 12V high has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.10.1 |
nonCriticalNTwelveVoltsLowA non-critical state of negative 12V low has been detected. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.6.5.10.2 |
platform OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.7 |
scalableNode OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.7.1 |
scalableNodeMode OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.7.1.1 |
scalableNodeModeNullOrUnknownThe scalable node is in a null or unknown mode. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.1.1.1 |
scalableNodeModePrimaryThe scalable node is in primary mode. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.1.1.2 |
scalableNodeModeSecondaryThe scalable node is in secondary mode. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.1.1.3 |
scalableNodeModeStandaloneThe scalable node is now in standalone mode. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.1.1.4 |
scalableNodeStandalone OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.7.1.2 |
standaloneMode OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.7.1.2.1 |
primaryThe scalable node is now in standalone primary mode. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.1 |
reset OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.2 |
resetPrimaryThe scalable node is now in standalone primary reset mode. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.2.1 |
resetSecondaryThe scalable node is now in standalone primary secondary mode. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.2.2 |
secondaryThe scalable node is now in standalone secondary mode. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.1.2.1.3 |
scalablePartition OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.7.2 |
scalablePartitionAlertThe scalabel partition has generated an alert. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.2.1 |
scalablePartitionState OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.7.2.2 |
scalablePartitionNullOrUnknownThe scalable partition state is 'null or unknown'. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.2.2.1 |
scalablePartitionPoweredOffThe scalable partition state is 'powered off'. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.2.2.2 |
scalablePartitionPoweringOnThe scalable partition state is 'powering on'. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.2.2.3 |
scalablePartitionResettingThe scalable partition state is 'resetting'. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.2.2.4 |
scalablePartitionShuttingDownThe scalable partition state is 'shutting down'. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.7.2.2.5 |
system OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.8 |
bootFailureThe system indicated a boot failure. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.8.1 |
fuelGauge OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.8.2 |
fuelGaugeLowFuelThe fuel gauge indicates low fuel. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.8.2.1 |
fuelGaugeNotRedundantThe fuel gauge indicates not redundant. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.8.2.2 |
fuelGaugeOverCurrentThe fuel gauge indicates over current. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.8.2.3 |
systemLoaderTimeoutThe system loader has timed out. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.8.3 |
systemOsTimeoutThe operating system has timed out. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.8.4 |
systemPfa OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.4.8.5 |
fanSystemPfaThe fan system has generated a PFA. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.8.5.1 |
systemPostTimeoutThe POST has timed out. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.8.6 |
systemPowerOffThe sytsem has powered off. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.8.7 |
systemPowerOnThe sytsem has powered on. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.8.8 |
systemRedundantPowerThe system is running on redundant power. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.8.9 |
systemTamperThe system has been tampered with. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.8.10 |
unknownThe system is in an unknown state. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.4.9 |
petFamily OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.5 |
petFamilyEventDetails OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.5.1 |
allVariableBindingsAll of the variable bindings for this PET trap.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.1 |
entityThe entity of this PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.2 |
entityInstanceThe entity instance of this PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.3 |
petEventDataThe event data of this PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.4 |
petEventSeverityThe severity of this PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.5 |
petEventSourceTypeThe source type of this PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.6 |
petEventTypeThe type of the PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.7 |
guidThe GUID for this PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.8 |
languageCodeThe language code for this PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.9 |
localTimeStampThe local time stamp of this PET event.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.5.1.10 |
manufacturerIdThe manufacturer ID for the source of the PET event.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.201.5.1.11 |
oemCustomFieldThe value for the OEM customer field of this PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.12 |
offsetThe offset for this PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.13 |
sensorDeviceThe sensor device for this PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.14 |
sensorNumberThe sensor number for this PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.15 |
sensorTypeThe sensor type for this PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.16 |
sequenceIdThe sequence ID for this PET event.ro Integer32 .1.3.6.1.4.1.2.6.159.201.5.1.17 |
systemIdThe system ID for this PET event.ro Integer32 .1.3.6.1.4.1.2.6.159.201.5.1.18 |
trapSourceTypeThe trap source type for this PET event.ro OCTET STRING .1.3.6.1.4.1.2.6.159.201.5.1.19 |
utcOffsetThe UTC offset for this PET event.ro Integer32 .1.3.6.1.4.1.2.6.159.201.5.1.20 |
petEnvironmental OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.5.2 |
petEnvironmentalSensor OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.5.2.1 |
sensorCaseIntrusionA sensor has detected a case intrusion. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.2.1.1 |
sensorCurrentA sensor has detected a current change. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.2.1.2 |
sensorFanA sensor has detected a fan change. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.2.1.3 |
sensorPowerSupplyA sensor has detected a power supply change. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.2.1.4 |
sensorTemperatureA sensor has detected a temperature change. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.2.1.5 |
sensorVoltageA sensor has detected a voltage change. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.2.1.6 |
firmware OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.5.3 |
bios OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.5.3.1 |
progressThe progress of the BIOS has changed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.3.1.1 |
hardware OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.5.4 |
cableInterconnectThe cable/interconnect hardware has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.4.1 |
drivebayThe monitor drivebay hardware has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.4.2 |
moduleBoardThe monitor module/board hardware has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.4.3 |
monitorAsicIcThe monitor ASIC/IC hardware has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.4.4 |
networkThe network hardware has generated an event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.4.5 |
watchdog1The hardware has generated a watchdog 1 event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.4.6 |
watchdog2The hardware has generated a watchdog 2 event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.4.7 |
petFamilySystem OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.5.5 |
petFamilySystemOs OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.5.5.1 |
petFamilySystemOsBootThe operating system on the host has booted. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.5.1.1 |
petFamilySystemOsOperation OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.5.5.1.2 |
heartbeatThe operating system has generated a heartbeat event. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.5.5.1.2.1 |
storageFamily OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.6 |
serveRaidController OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.6.1 |
physicalDrive OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.6.1.1 |
vendorUnsupportedThe vendor for this physical drive is unsupported. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.6.1.1.1 |
state OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.6.1.2 |
notFoundNo controllers were found in this system. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.6.1.2.1 |
configManagerFamily OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.7 |
cmProfile OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.7.1 |
cmExecutionThe configured profile was executed. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.7.1.1 |
correlationFamily OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.8 |
nmo OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.8.1 |
blade_ChassisA Blade has been correlated with a system. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.8.1.1 |
massConfigFamily OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.9 |
overwrittenThe profile was overwritten. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.9.1 |
conflictThere was a conflict with the configuration. NOTIFICATION-TYPE .1.3.6.1.4.1.2.6.159.201.9.2 |
directorTrapsConformance OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.100 |
directorTrapsGroups OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.100.1 |
directorTrapsGroupThe objects group for objects defined in this module. Unknown .1.3.6.1.4.1.2.6.159.201.100.1.1 |
directorNotificationsGroupThe notification group for notifications defined in this module. Unknown .1.3.6.1.4.1.2.6.159.201.100.1.2 |
directorTrapsCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.201.100.2 |
directorTrapsComplianceThe compliance statement for this module. Unknown .1.3.6.1.4.1.2.6.159.201.100.2.1 |
description OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.202 |
trapTypeThe type of the event.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.202.1 |
trapSeverityThe severity of the event.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.202.2 |
trapSenderNameThe system name from which the event was sent.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.202.3 |
trapManagedObjectNameThe system name for which the event was generated.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.202.4 |
trapTextText associated with the event.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.202.5 |
trapCategoryThe category of the event.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.202.6 |
details OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.159.9696 |
charEight bit unsigned event detail.ro OCTET STRING .1.3.6.1.4.1.2.6.159.9696.1 |
shortSixteen bit signed event detail.ro Integer32 .1.3.6.1.4.1.2.6.159.9696.2 |
intThirty-two bit signed event detail.ro Integer32 .1.3.6.1.4.1.2.6.159.9696.3 |
longSixty-four bit signed event detail.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.9696.4 |
booleanThirty-two bit unsigned event detail.ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.9696.5 |
floatThirty-two bit decimal pointed event detail.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.9696.6 |
doubleSixty-four bit decimal pointed event detail.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.9696.7 |
octetA string of bytes holding an event detail.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.9696.8 |
stringA string of unicode chars (normal text) holding an event detail.ro SnmpAdminString (SNMP-FRAMEWORK-MIB) .1.3.6.1.4.1.2.6.159.9696.9 |
dateTimeDate and time since 1/1970 as an event detail.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.9696.10 |
uniCharA unicode char holding an event detail.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.9696.11 |
byteOne byte holding an event detail.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2.6.159.9696.12 |