Home/Catalog/IBM-AS400-RWS-MIB

IBM-AS400-RWS-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for IBM-AS400-RWS-MIB.

25
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

25 total
Object Name
ibm
OBJECT IDENTIFIER
.1.3.6.1.4.1.2
IMPORTS
Unknown
.1.3.6.1.4.1.2
ibmProd
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6
ibmAs400Agent
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.11
ibmAs400Rws
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.11.1
rwsTableTable of AS/400 remote workstation (RWS) controllers.
SEQUENCE OF RwsEntry
.1.3.6.1.4.1.2.6.11.1.1
rwsEntryAn entry for each RWS controller. Table is indexed by rwsCtlName.
RwsEntry
.1.3.6.1.4.1.2.6.11.1.1.1
rwsCtlNameRWS controller description name.ro
DisplayString
.1.3.6.1.4.1.2.6.11.1.1.1.1
rwsOperStateOperational state of the RWS controller description.rw
Enumeration
.1.3.6.1.4.1.2.6.11.1.1.1.2
rwsAppcDevNameName of the APPC device description associated with the RWS controller.ro
DisplayString
.1.3.6.1.4.1.2.6.11.1.1.1.3
rwsAppcDevStateOperational state of the associated APPC device.rw
Enumeration
.1.3.6.1.4.1.2.6.11.1.1.1.4
rwsAppcCtlNameName of the APPC controller associated with the RWS controller. The associated APPN MIB instance of ibmappnNodeLsState gives its operational state.ro
DisplayString
.1.3.6.1.4.1.2.6.11.1.1.1.5
rwsCpNameFully-qualified control point name of the remote control unit. Format is NETID.CPNAME.ro
DisplayString
.1.3.6.1.4.1.2.6.11.1.1.1.6
rwsTypeMachine type of the RWS controller.ro
DisplayString
.1.3.6.1.4.1.2.6.11.1.1.1.7
rwsModelModel number of the RWS controller.ro
DisplayString
.1.3.6.1.4.1.2.6.11.1.1.1.8
rwsSerialSerial number value in format xx-yyyyyyy, from the customer setup (CSU) field. In general, xx is the Plant of Manufacture, and yyyyyyy is the serial number. However the user may configure any valid value for each digit. Valid values for each digit are A-Z and 0-0. Note this value is not guaranteed to be current when the value of rwsAppcDevState is not active.ro
DisplayString
.1.3.6.1.4.1.2.6.11.1.1.1.9
rwsReleaseMicrocode release, modification and patch level. For a 5494, the format is rrrrmmpp, For a 5394 BB, the format is rrpp, where r=release digit, m=modification digit, p=patch digit. Example: rel. 1.1 mod. 2 patch 3 would be 01010203. Note this value is not guaranteed to be current when the value of rwsAppcDevState is not active.ro
DisplayString
.1.3.6.1.4.1.2.6.11.1.1.1.10
rwsDevTableTable of nonprogrammable devices attached to RWS controllers.
SEQUENCE OF RwsDevEntry
.1.3.6.1.4.1.2.6.11.1.2
rwsDevEntryAn entry for each nonprogrammable device attached to an RWS controller. Table is indexed by rwsCtlName and rwsDevName.
RwsDevEntry
.1.3.6.1.4.1.2.6.11.1.2.1
rwsDevCtlNameController name associated with device.ro
DisplayString
.1.3.6.1.4.1.2.6.11.1.2.1.1
rwsDevNameDevice name.ro
DisplayString
.1.3.6.1.4.1.2.6.11.1.2.1.2
rwsDevOperStateOperational state of device.rw
Enumeration
.1.3.6.1.4.1.2.6.11.1.2.1.3
rwsDevSerialSerial number value in format xx-yyyyyyy, reported by the RWS control unit for the device. In general, xx is the Plant of Manufacture, and yyyyyyy is the serial number. Note this value is not guaranteed to be current when the value of rwsDevState is not active.ro
DisplayString
.1.3.6.1.4.1.2.6.11.1.2.1.4
rwsGeneralInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.2.6.11.1.99
rwsNumCtlsNumber of RWS controllers (rows in rwsTable).ro
INTEGER
.1.3.6.1.4.1.2.6.11.1.99.1
IBM-AS400-RWS-MIB - SNMP MIB Reference | MIBs Explorer