IBM-AS400-RWS-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for IBM-AS400-RWS-MIB.
25
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
25 total| Object Name |
|---|
ibm OBJECT IDENTIFIER .1.3.6.1.4.1.2 |
IMPORTS Unknown .1.3.6.1.4.1.2 |
ibmProd OBJECT IDENTIFIER .1.3.6.1.4.1.2.6 |
ibmAs400Agent OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.11 |
ibmAs400Rws OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.11.1 |
rwsTableTable of AS/400 remote workstation (RWS) controllers. SEQUENCE OF RwsEntry .1.3.6.1.4.1.2.6.11.1.1 |
rwsEntryAn entry for each RWS controller.
Table is indexed by rwsCtlName. RwsEntry .1.3.6.1.4.1.2.6.11.1.1.1 |
rwsCtlNameRWS controller description name.ro DisplayString .1.3.6.1.4.1.2.6.11.1.1.1.1 |
rwsOperStateOperational state of the RWS controller description.rw Enumeration .1.3.6.1.4.1.2.6.11.1.1.1.2 |
rwsAppcDevNameName of the APPC device description associated with the RWS
controller.ro DisplayString .1.3.6.1.4.1.2.6.11.1.1.1.3 |
rwsAppcDevStateOperational state of the associated APPC device.rw Enumeration .1.3.6.1.4.1.2.6.11.1.1.1.4 |
rwsAppcCtlNameName of the APPC controller associated with the RWS controller.
The associated APPN MIB instance of ibmappnNodeLsState gives
its operational state.ro DisplayString .1.3.6.1.4.1.2.6.11.1.1.1.5 |
rwsCpNameFully-qualified control point name of the remote control unit.
Format is NETID.CPNAME.ro DisplayString .1.3.6.1.4.1.2.6.11.1.1.1.6 |
rwsTypeMachine type of the RWS controller.ro DisplayString .1.3.6.1.4.1.2.6.11.1.1.1.7 |
rwsModelModel number of the RWS controller.ro DisplayString .1.3.6.1.4.1.2.6.11.1.1.1.8 |
rwsSerialSerial number value in format xx-yyyyyyy, from the customer setup
(CSU) field.
In general, xx is the Plant of Manufacture, and yyyyyyy is the
serial number. However the user may configure any valid value
for each digit. Valid values for each digit are A-Z and 0-0.
Note this value is not guaranteed to be current when the value
of rwsAppcDevState is not active.ro DisplayString .1.3.6.1.4.1.2.6.11.1.1.1.9 |
rwsReleaseMicrocode release, modification and patch level.
For a 5494, the format is rrrrmmpp,
For a 5394 BB, the format is rrpp,
where r=release digit, m=modification digit, p=patch digit.
Example: rel. 1.1 mod. 2 patch 3 would be 01010203.
Note this value is not guaranteed to be current when the value
of rwsAppcDevState is not active.ro DisplayString .1.3.6.1.4.1.2.6.11.1.1.1.10 |
rwsDevTableTable of nonprogrammable devices attached to RWS controllers. SEQUENCE OF RwsDevEntry .1.3.6.1.4.1.2.6.11.1.2 |
rwsDevEntryAn entry for each nonprogrammable device attached to an RWS
controller. Table is indexed by rwsCtlName and rwsDevName. RwsDevEntry .1.3.6.1.4.1.2.6.11.1.2.1 |
rwsDevCtlNameController name associated with device.ro DisplayString .1.3.6.1.4.1.2.6.11.1.2.1.1 |
rwsDevNameDevice name.ro DisplayString .1.3.6.1.4.1.2.6.11.1.2.1.2 |
rwsDevOperStateOperational state of device.rw Enumeration .1.3.6.1.4.1.2.6.11.1.2.1.3 |
rwsDevSerialSerial number value in format xx-yyyyyyy, reported by the RWS
control unit for the device.
In general, xx is the Plant of Manufacture, and yyyyyyy is the
serial number.
Note this value is not guaranteed to be current when the value
of rwsDevState is not active.ro DisplayString .1.3.6.1.4.1.2.6.11.1.2.1.4 |
rwsGeneralInfo OBJECT IDENTIFIER .1.3.6.1.4.1.2.6.11.1.99 |
rwsNumCtlsNumber of RWS controllers (rows in rwsTable).ro INTEGER .1.3.6.1.4.1.2.6.11.1.99.1 |