HPN-ICF-LAG-MIB
AI MIB Summary
The HPN-ICF-LAG-MIB module enables monitoring and management of Link Aggregation Control Protocol (LACP) session states, member port statuses, and aggregation group parameters on HP Networking ICF (Intelligent Control Fabric) switches. It provides specific counters and status indicators for LACP negotiation outcomes, timeout configurations, and active versus passive mode operations within link aggregation bundles.
LACP extend MIB.
Main OID:
hpnicfLAG.1.3.6.1.4.1.11.2.14.11.15.8.25
26
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
26 total| Object Name |
|---|
hpnicfLAGLACP extend MIB. MODULE-IDENTITY .1.3.6.1.4.1.11.2.14.11.15.8.25 |
hpnicfLAGMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.14.11.15.8.25.1 |
hpnicfAggLinkTableA table of aggregate link objects. SEQUENCE OF HpnicfAggLinkEntry .1.3.6.1.4.1.11.2.14.11.15.8.25.1.1 |
hpnicfAggLinkEntryEntry of table. HpnicfAggLinkEntry .1.3.6.1.4.1.11.2.14.11.15.8.25.1.1.1 |
hpnicfAggLinkNumberThe serial number of aggregation group.ro Integer32 .1.3.6.1.4.1.11.2.14.11.15.8.25.1.1.1.1 |
hpnicfAggLinkNameAggregation name.rw DisplayString .1.3.6.1.4.1.11.2.14.11.15.8.25.1.1.1.2 |
hpnicfAggLinkModeType of aggregation.
manual: Manual aggregation, no LACP.
static: Membership specified by user, LACP is
used to validate.
dynamic: Completely dynamic aggregation detected
by LACP.rw Enumeration .1.3.6.1.4.1.11.2.14.11.15.8.25.1.1.1.3 |
hpnicfAggLinkPortListList of ports in this link aggregation group, by bridge port
number. If the mode of the link aggregation group is manual
or static, you can update this list to your
hearts content. However, if the link aggregation group is
dynamic, the system will maintain it. You are not
permitted to set the value of this to
all zeroes.rw PortList (Q-BRIDGE-MIB) .1.3.6.1.4.1.11.2.14.11.15.8.25.1.1.1.4 |
hpnicfAggLinkStateRowStatus, now support three states:
createAndGo, active, destroy.rw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.11.2.14.11.15.8.25.1.1.1.5 |
hpnicfAggPortListSelectedPortsA PortList of physical ports that have been
selected but not attached to this aggregator.
When the bit is set to 1,it means the
corresponding port is in the portlist.ro PortList (Q-BRIDGE-MIB) .1.3.6.1.4.1.11.2.14.11.15.8.25.1.1.1.6 |
hpnicfAggPortListSamePartnerPortsPortList of physical ports that have the
same Actor SystemID and partner systemID as
this aggregator, but have different actor
and partner keys of aggregator.ro PortList (Q-BRIDGE-MIB) .1.3.6.1.4.1.11.2.14.11.15.8.25.1.1.1.7 |
hpnicfAggPortTableA table of aggregate port objects. SEQUENCE OF HpnicfAggPortEntry .1.3.6.1.4.1.11.2.14.11.15.8.25.1.2 |
hpnicfAggPortEntryEntry of table. HpnicfAggPortEntry .1.3.6.1.4.1.11.2.14.11.15.8.25.1.2.1 |
hpnicfAggPortIndexPort ifindex which is according to RFC1213 MIB.ro Gauge32 .1.3.6.1.4.1.11.2.14.11.15.8.25.1.2.1.1 |
hpnicfAggPortNotAttachedReasonReason why this port is selected for an
aggregator but not attached,
0: The port is attached to this aggregator.
1: The current number of active ports has
reached the upper limit.
2: All aggregation resources are already in-use.
3: The port's configuration is improper
for being attached.
4: The port's partner is improper for being attached.
5: The number of current active ports
has not reached the lower limit.
6: The port's physical state (down) is
improper for being attached.
7: The port is not selected for an aggregator.
8: The port's hardware restriction is
improper for being attached.
9: The port's speed is improper for being attached.
10: The port's duplex mode is improper for being attached.rw Integer32 .1.3.6.1.4.1.11.2.14.11.15.8.25.1.2.1.2 |
hpnicfAggPortLacpStateControl ports' lacp enble or disable.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.11.2.14.11.15.8.25.1.2.1.3 |
hpnicfAggPortNotAttachedStringThe string which interprets this
port is selected for an aggregator
but not attached.rw DisplayString .1.3.6.1.4.1.11.2.14.11.15.8.25.1.2.1.4 |
hpnicfAggResourceAllocationValueThe priority value calculated to decide which
aggregations have first call on the load-sharing
aggregation resources in the hardware. It
depends on the aggregation type and total
speed.ro PortList (Q-BRIDGE-MIB) .1.3.6.1.4.1.11.2.14.11.15.8.25.1.3 |
hpnicfLAGMibNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.14.11.15.8.25.2 |
hpnicfAggSpeedChangedNotificationThis event will be triggered whenever an
aggregation changes its speed. NOTIFICATION-TYPE .1.3.6.1.4.1.11.2.14.11.15.8.25.2.1 |
hpnicfAggPortInactiveNotificationThis event will be triggered whenever any port
in aggregator is made inactive. NOTIFICATION-TYPE .1.3.6.1.4.1.11.2.14.11.15.8.25.2.2 |
hpnicfAggPortInactiveNotification2This event will be triggered whenever the port
in aggregator is made inactive. NOTIFICATION-TYPE .1.3.6.1.4.1.11.2.14.11.15.8.25.2.3 |
hpnicfAggPortActiveNotificationThis event will be triggered whenever the port
in aggregator is made active. NOTIFICATION-TYPE .1.3.6.1.4.1.11.2.14.11.15.8.25.2.4 |
hpnicfLAGMibConformance OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.14.11.15.8.25.3 |
hpnicfLAGMibCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.14.11.15.8.25.3.1 |
hpnicfLAGMibGroup OBJECT IDENTIFIER .1.3.6.1.4.1.11.2.14.11.15.8.25.3.2 |