Home/Catalog/HH3C-LAG-MIB

HH3C-LAG-MIB

AI MIB Summary

The HH3C-LAG-MIB module enables monitoring and management of Link Aggregation Control Protocol (LACP) extended attributes on H3C network devices, specifically tracking LAG group states, member port status, and aggregation session parameters.

LACP extend MIB.
Main OID:
hh3cLAG.1.3.6.1.4.1.25506.8.25
26
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

26 total
Object Name
hh3cLAGLACP extend MIB.
MODULE-IDENTITY
.1.3.6.1.4.1.25506.8.25
hh3cLAGMibObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.8.25.1
hh3cAggLinkTableA table of aggregate link objects.
SEQUENCE OF Hh3cAggLinkEntry
.1.3.6.1.4.1.25506.8.25.1.1
hh3cAggLinkEntryEntry of table.
Hh3cAggLinkEntry
.1.3.6.1.4.1.25506.8.25.1.1.1
hh3cAggLinkNumberThe serial number of aggregation group.ro
Integer32
.1.3.6.1.4.1.25506.8.25.1.1.1.1
hh3cAggLinkNameAggregation name.rw
DisplayString
.1.3.6.1.4.1.25506.8.25.1.1.1.2
hh3cAggLinkModeType of aggregation. manual: Manual aggregation, no LACP. static: Membership specified by user, LACP is used to validate. dynamic: Completely dynamic aggregation detected by LACP.rw
Enumeration
.1.3.6.1.4.1.25506.8.25.1.1.1.3
hh3cAggLinkPortListList of ports in this link aggregation group, by bridge port number. If the mode of the link aggregation group is manual or static, you can update this list to your hearts content. However, if the link aggregation group is dynamic, the system will maintain it. You are not permitted to set the value of this to all zeroes.rw
PortList (Q-BRIDGE-MIB)
.1.3.6.1.4.1.25506.8.25.1.1.1.4
hh3cAggLinkStateRowStatus, now support three states: createAndGo, active, destroy.rw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.25506.8.25.1.1.1.5
hh3cAggPortListSelectedPortsA PortList of physical ports that have been selected but not attached to this aggregator. When the bit is set to 1,it means the corresponding port is in the portlist.ro
PortList (Q-BRIDGE-MIB)
.1.3.6.1.4.1.25506.8.25.1.1.1.6
hh3cAggPortListSamePartnerPortsPortList of physical ports that have the same Actor SystemID and partner systemID as this aggregator, but have different actor and partner keys of aggregator.ro
PortList (Q-BRIDGE-MIB)
.1.3.6.1.4.1.25506.8.25.1.1.1.7
hh3cAggPortTableA table of aggregate port objects.
SEQUENCE OF Hh3cAggPortEntry
.1.3.6.1.4.1.25506.8.25.1.2
hh3cAggPortEntryEntry of table.
Hh3cAggPortEntry
.1.3.6.1.4.1.25506.8.25.1.2.1
hh3cAggPortIndexPort ifindex which is according to RFC1213 MIB.ro
Gauge32
.1.3.6.1.4.1.25506.8.25.1.2.1.1
hh3cAggPortNotAttachedReasonReason why this port is selected for an aggregator but not attached, 0: The port is attached to this aggregator. 1: The current number of active ports has reached the upper limit. 2: All aggregation resources are already in-use. 3: The port's configuration is improper for being attached. 4: The port's partner is improper for being attached. 5: The number of current active ports has not reached the lower limit. 6: The port's physical state (down) is improper for being attached. 7: The port is not selected for an aggregator. 8: The port's hardware restriction is improper for being attached. 9: The port's speed is improper for being attached. 10: The port's duplex mode is improper for being attached.rw
Integer32
.1.3.6.1.4.1.25506.8.25.1.2.1.2
hh3cAggPortLacpStateControl ports' lacp enble or disable.rw
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.25506.8.25.1.2.1.3
hh3cAggPortNotAttachedStringThe string which interprets this port is selected for an aggregator but not attached.rw
DisplayString
.1.3.6.1.4.1.25506.8.25.1.2.1.4
hh3cAggResourceAllocationValueThe priority value calculated to decide which aggregations have first call on the load-sharing aggregation resources in the hardware. It depends on the aggregation type and total speed.ro
PortList (Q-BRIDGE-MIB)
.1.3.6.1.4.1.25506.8.25.1.3
hh3cLAGMibNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.8.25.2
hh3cAggSpeedChangedNotificationThis event will be triggered whenever an aggregation changes its speed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.8.25.2.1
hh3cAggPortInactiveNotificationThis event will be triggered whenever any port in aggregator is made inactive.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.8.25.2.2
hh3cAggPortInactiveNotification2This event will be triggered whenever the port in aggregator is made inactive.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.8.25.2.3
hh3cAggPortActiveNotificationThis event will be triggered whenever the port in aggregator is made active.
NOTIFICATION-TYPE
.1.3.6.1.4.1.25506.8.25.2.4
hh3cLAGMibConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.8.25.3
hh3cLAGMibCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.8.25.3.1
hh3cLAGMibGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.25506.8.25.3.2
HH3C-LAG-MIB - SNMP MIB Reference | MIBs Explorer