H3C-POWER-ETH-EXT-MIB

AI MIB Summary

The H3C-POWER-ETH-EXT-MIB monitors and manages extended power supply unit (PSU) status, voltage levels, current consumption, and temperature metrics for H3C Ethernet switches equipped with redundant power systems. This module enables granular visibility into power redundancy states and environmental thresholds to facilitate proactive hardware failure detection and capacity planning.

Description.
Main OID:
h3cPowerEthernetExt.1.3.6.1.4.1.2011.10.2.14
129
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

129 total
Object Name
h3cPowerEthernetExt
MODULE-IDENTITY
.1.3.6.1.4.1.2011.10.2.14
h3cPsePortTable
SEQUENCE OF H3cPsePortEntry
.1.3.6.1.4.1.2011.10.2.14.1
h3cPsePortEntry
H3cPsePortEntry
.1.3.6.1.4.1.2011.10.2.14.1.1
h3cPsePortFaultDescriptionrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.10.2.14.1.1.2
h3cPsePortPeakPowerrw
Integer32
.1.3.6.1.4.1.2011.10.2.14.1.1.3
h3cPsePortAveragePowerrw
Integer32
.1.3.6.1.4.1.2011.10.2.14.1.1.4
h3cPsePortCurrentPowerro
Integer32
.1.3.6.1.4.1.2011.10.2.14.1.1.5
h3cPsePortPowerLimitrw
Integer32
.1.3.6.1.4.1.2011.10.2.14.1.1.6
h3cPsePortProfileIndexrw
Integer32
.1.3.6.1.4.1.2011.10.2.14.1.1.7
h3cMainPseTable
SEQUENCE OF H3cMainPseEntry
.1.3.6.1.4.1.2011.10.2.14.2
h3cMainPseEntry
H3cMainPseEntry
.1.3.6.1.4.1.2011.10.2.14.2.1
h3cMainPsePowerLimitrw
Integer32
.1.3.6.1.4.1.2011.10.2.14.2.1.1
h3cMainPseAveragePowerrw
Integer32
.1.3.6.1.4.1.2011.10.2.14.2.1.2
h3cMainPsePeakPowerrw
Integer32
.1.3.6.1.4.1.2011.10.2.14.2.1.3
h3cMainGuaranteedPowerRemainingro
Integer32
.1.3.6.1.4.1.2011.10.2.14.2.1.4
h3cMainPsePriorityModerw
Enumeration
.1.3.6.1.4.1.2011.10.2.14.2.1.5
h3cMainPseLegacyrw
Enumeration
.1.3.6.1.4.1.2011.10.2.14.2.1.6
h3cMainPsePowerPriorityrw
Enumeration
.1.3.6.1.4.1.2011.10.2.14.2.1.7
h3cPseAutoDetectActiverw
Enumeration
.1.3.6.1.4.1.2011.10.2.14.3
h3cPseComformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.10.2.14.4
h3cPseCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.10.2.14.4.1
h3cPseCompliance
Unknown
.1.3.6.1.4.1.2011.10.2.14.4.1.1
h3cPseGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.10.2.14.4.2
h3cPsePortGroup
Unknown
.1.3.6.1.4.1.2011.10.2.14.4.2.1
h3cMainPseGroup
Unknown
.1.3.6.1.4.1.2011.10.2.14.4.2.2
h3cPseScalarGroup
Unknown
.1.3.6.1.4.1.2011.10.2.14.4.2.3
h3cPsePDNotificationGroup
Unknown
.1.3.6.1.4.1.2011.10.2.14.4.2.4
h3cPseProfilesGroup
Unknown
.1.3.6.1.4.1.2011.10.2.14.4.2.5
h3cPOEPowerThresholdLimitGroup
Unknown
.1.3.6.1.4.1.2011.10.2.14.4.2.6
h3cPOEPowerSupInfoGroup
Unknown
.1.3.6.1.4.1.2011.10.2.14.4.2.7
h3cPOEPowerDCOutStateGroup
Unknown
.1.3.6.1.4.1.2011.10.2.14.4.2.8
h3cPOEPowerDCOutInfoGroup
Unknown
.1.3.6.1.4.1.2011.10.2.14.4.2.9
h3cPOEPowerACSwitchStateModuleGroup
Unknown
.1.3.6.1.4.1.2011.10.2.14.4.2.10
h3cPOEPowerInCurStateGroup
Unknown
.1.3.6.1.4.1.2011.10.2.14.4.2.11
h3cPOEPowerAlarmStateGroup
Unknown
.1.3.6.1.4.1.2011.10.2.14.4.2.12
h3cPsePowerMaxValuerw
Integer32
.1.3.6.1.4.1.2011.10.2.14.5
h3cpseportNotification
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.10.2.14.6
h3cpsePDChangeNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.1
h3cPOEDisconnectNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.2
h3cPOEInputErrorNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.3
h3cPOEOutputErrorNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.4
h3cPOEOverVoltageNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.5
h3cPOEOverTempNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.6
h3cPOEFanErrorNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.7
h3cPOEModuleShutdownNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.8
h3cPOECurRestrictedNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.9
h3cPOEACSwitchNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.10
h3cPOEACInCurANotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.11
h3cPOEACInCurBNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.12
h3cPOEACInCurCNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.13
h3cPOEACSwitchVolABNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.14
h3cPOEACSwitchVolBCNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.15
h3cPOEACSwitchVolCANotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.16
h3cPOEDCOutVolNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.17
h3cPOEShutdownNotification
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.10.2.14.6.18
h3cPseProfilesTable
SEQUENCE OF H3cPseProfilesEntry
.1.3.6.1.4.1.2011.10.2.14.7
h3cPseProfilesEntry
H3cPseProfilesEntry
.1.3.6.1.4.1.2011.10.2.14.7.1
h3cPseProfileIndex
Integer32
.1.3.6.1.4.1.2011.10.2.14.7.1.1
h3cPseProfileNamerw
DisplayString
.1.3.6.1.4.1.2011.10.2.14.7.1.2
h3cPseProfilePowerModerw
Enumeration
.1.3.6.1.4.1.2011.10.2.14.7.1.3
h3cPseProfilePowerLimitrw
Integer32
.1.3.6.1.4.1.2011.10.2.14.7.1.4
h3cPseProfilePriorityrw
Enumeration
.1.3.6.1.4.1.2011.10.2.14.7.1.5
h3cPseProfilePairsrw
Enumeration
.1.3.6.1.4.1.2011.10.2.14.7.1.6
h3cPseProfileApplyNumro
Integer32
.1.3.6.1.4.1.2011.10.2.14.7.1.7
h3cPseProfileRowStatusrw
RowStatus (SNMPv2-TC)
.1.3.6.1.4.1.2011.10.2.14.7.1.8
h3cPOEPowerObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.10.2.14.8
h3cPOEThresholdLimitObjs
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.10.2.14.8.1
h3cPOEThresholdACMimimumrw
OCTET STRING
.1.3.6.1.4.1.2011.10.2.14.8.1.1
h3cPOEThresholdACMaximumrw
OCTET STRING
.1.3.6.1.4.1.2011.10.2.14.8.1.2
h3cPOEThresholdDCMinimumrw
OCTET STRING
.1.3.6.1.4.1.2011.10.2.14.8.1.3
h3cPOEThresholdDCMaximumrw
OCTET STRING
.1.3.6.1.4.1.2011.10.2.14.8.1.4
h3cPOESupModuleInfoObjs
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.10.2.14.8.2
h3cPOEPowerTypero
OCTET STRING
.1.3.6.1.4.1.2011.10.2.14.8.2.1
h3cPOEPowerModuleNumro
Integer32
.1.3.6.1.4.1.2011.10.2.14.8.2.2
h3cPOESupervisionModuleNamero
OCTET STRING
.1.3.6.1.4.1.2011.10.2.14.8.2.3
h3cPOESMMajorVersionro
Integer32
.1.3.6.1.4.1.2011.10.2.14.8.2.4
h3cPOESMMinorVersionro
Integer32
.1.3.6.1.4.1.2011.10.2.14.8.2.5
h3cPOESMFactorNamero
OCTET STRING
.1.3.6.1.4.1.2011.10.2.14.8.2.6
h3cPOEModuleInfoTable
SEQUENCE OF H3cPOEModuleInfoEntry
.1.3.6.1.4.1.2011.10.2.14.8.2.7
h3cPOEModuleInfoEntry
H3cPOEModuleInfoEntry
.1.3.6.1.4.1.2011.10.2.14.8.2.7.1
h3cPOEModuleIndexro
Integer32
.1.3.6.1.4.1.2011.10.2.14.8.2.7.1.1
h3cPOEModuleIDro
Integer32
.1.3.6.1.4.1.2011.10.2.14.8.2.7.1.2
h3cPOEModuleInfoPowerro
Integer32
.1.3.6.1.4.1.2011.10.2.14.8.2.7.1.3
h3cPOEModuleHardVerInforo
OCTET STRING
.1.3.6.1.4.1.2011.10.2.14.8.2.7.1.4
h3cPOEDCOutStateObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.10.2.14.8.3
h3cPOEDCOutStateModuleNumro
Integer32
.1.3.6.1.4.1.2011.10.2.14.8.3.1
h3cPOEDCOutStateTable
SEQUENCE OF H3cPOEDCOutStateEntry
.1.3.6.1.4.1.2011.10.2.14.8.3.2
h3cPOEDCOutStateEntry
H3cPOEDCOutStateEntry
.1.3.6.1.4.1.2011.10.2.14.8.3.2.1
h3cPOEDCOutStateIndexro
Integer32
.1.3.6.1.4.1.2011.10.2.14.8.3.2.1.1
h3cPOEDCOutDCVolAlarmro
DCAlarmState
.1.3.6.1.4.1.2011.10.2.14.8.3.2.1.2
h3cPOEDCOutInfoObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.10.2.14.8.4
h3cPOEDCOutCurNumro
Integer32
.1.3.6.1.4.1.2011.10.2.14.8.4.1
h3cPOEDCOutInfoTable
SEQUENCE OF H3cPOEDCOutInfoEntry
.1.3.6.1.4.1.2011.10.2.14.8.4.2
h3cPOEDCOutInfoEntry
H3cPOEDCOutInfoEntry
.1.3.6.1.4.1.2011.10.2.14.8.4.2.1
h3cPOEDCOutInfoIndexro
Integer32
.1.3.6.1.4.1.2011.10.2.14.8.4.2.1.1
h3cPOEDCOutVolro
OCTET STRING
.1.3.6.1.4.1.2011.10.2.14.8.4.2.1.2
h3cPOEDCOutInfoLoadCurro
OCTET STRING
.1.3.6.1.4.1.2011.10.2.14.8.4.2.1.3
h3cPOEACSwitchStateModuleObjs
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.10.2.14.8.5
h3cPOEACSwitchStateModuleNumro
Integer32
.1.3.6.1.4.1.2011.10.2.14.8.5.1
h3cPOEACSwitchStateTable
SEQUENCE OF H3cPOEACSwitchStateEntry
.1.3.6.1.4.1.2011.10.2.14.8.5.2
Showing 100 of 129 OID objects

H3C-POWER-ETH-EXT-MIB Technical Reference Overview

The H3C-POWER-ETH-EXT-MIB SNMP MIB module published by Huawei defines 129 managed OID objects, including 80 scalar/column metrics, 9 SNMP tables, and 18 trap/notification events anchored at base OID .1.3.6.1.4.1.2011.10.2.14. Key tabular structures include h3cMainPseTable, h3cPOEACSwitchStateTable, h3cPOEAlarmStateInfoTable, h3cPOEDCOutInfoTable, h3cPOEDCOutStateTable, h3cPOEModuleInfoTable. Monitored SNMP traps/notifications include h3cPOEACInCurANotification, h3cPOEACInCurBNotification, h3cPOEACInCurCNotification, h3cPOEACSwitchNotification, h3cPOEACSwitchVolABNotification, h3cPOEACSwitchVolBCNotification.

Key OID Definitions in H3C-POWER-ETH-EXT-MIB

h3cPowerEthernetExtMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.2011.10.2.14

Description.

h3cMainPseTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.2

Description.

h3cPOEACSwitchStateTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.8.5.2

The table of the AC switch state on this POE power.

h3cPOEAlarmStateInfoTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.8.7.2

All alarm states in the POE power modules.

h3cPOEDCOutInfoTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.8.4.2

The table of the DC output information on this POE power.

h3cPOEDCOutStateTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.8.3.2

The table of DC output power state on this POE power.

h3cPOEModuleInfoTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.8.2.7

The table of the module information on this POE power.

h3cPOESwitchStateVolExTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.8.6.5

All alarm status of the VOL status. The value of this node will be one of the following values: normal (1), underLimit (2), aboveLimit (3), lackPhrase (4), fuseBroken (5), switchOff (6), otherError (7).

h3cPsePortTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.1

The indexing scheme is taken form that used by the IETF Power MIB. The same indexing scheme is used to give continuity in behaviour between that standard and this extensions definitioin.

h3cPseProfilesTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.7

A table of objects representing a set of power profiles. Power profiles can be applied to PoE ports, which have the effect of automatically setting the priority, power limit and PoE enable MIB objects to the values specified in the power profile.

h3cPOEACInCurANotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.11

This notification indicates the AC input current A alarm state of this POE power.

h3cPOEACInCurBNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.12

This notification indicates the AC input current B alarm state of this POE power.

h3cPOEACInCurCNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.13

This notification indicates the AC input current C alarm state of this POE power.

h3cPOEACSwitchNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.10

This notification indicates the AC input switch alarm of this POE power.

h3cPOEACSwitchVolABNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.14

This notification indicates the AC input voltage AB alarm state of this POE power.

h3cPOEACSwitchVolBCNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.15

This notification indicates the AC input voltage BC alarm state of this POE power.

h3cPOEACSwitchVolCANotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.16

This notification indicates the AC input voltage CA alarm state of this POE power.

h3cPOECurRestrictedNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.9

This notification indicates the POE power module current is restricted.

h3cPOEDCOutVolNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.17

This notification indicates the DC output alarm of this POE power.

h3cPOEDisconnectNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.2

This notification indicates the POE power module does not disconnect.

h3cPOEFanErrorNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.7

This notification indicates the POE power module fan error.

h3cPOEInputErrorNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.3

This notification indicates the POE power module input error.

h3cPOEModuleShutdownNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.8

This notification indicates the POE power module is closed.

h3cPOEOutputErrorNotificationNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.10.2.14.6.4

This notification indicates the POE power module output error.

More MIBs from Huawei

Browse all HuaweiMIBs →
H3C-ENTITY-VENDORTYPE-OID-MIB

SNMP MIB module

1462 objects→
HUAWEI-WLAN-CONFIGURATION-MIB

The HUAWEI-WLAN-CONFIGURATION-MIB facilitates the configuration and monitoring of Huawei Wireless LAN access point parameters, specifically managing AP port link profiles and broadcast suppression settings. This module enables administrators to enforce traffic control policies and optimize wireless network performance by adjusting switch profile associations and limiting broadcast traffic on specific ports.

1280 objects→
HUAWEI-XQoS-MIB

The HUAWEI-XQoS-MIB enables configuration and real-time monitoring of Class Based QoS parameters on Huawei network devices, specifically tracking traffic classification rules, queue states, and policy enforcement metrics. This module facilitates granular control over bandwidth allocation and packet prioritization by exposing objects for policy definitions, interface queue depths, and dropped packet counters associated with QoS classes.

1134 objects→
HUAWEI-ENT-VOICE-PBX-MIB

The HUAWEI-ENT-VOICE-PBX-MIB enables SNMP-based monitoring and configuration of Huawei enterprise PBX systems, specifically tracking voice trunk states, active call session counts, and hardware resource utilization for telephony management.

1011 objects→
HUAWEI-WLAN-DEVICE-MIB

The HUAWEI-WLAN-DEVICE-MIB enables SNMP-based monitoring and configuration of Huawei Access Point hardware, providing granular visibility into device status, radio interface statistics, client association counts, and operational health metrics.

897 objects→
HUAWEI-BRAS-SBC-MIB

The HUAWEI-BRAS-SBC-MIB module provides configuration and status monitoring for Huawei Broadband Remote Access Server (BRAS) Session Border Controllers, specifically tracking session establishment parameters, resource utilization, and protocol state variables. It enables administrators to manage SBC-specific attributes such as call routing policies, media stream limits, and session timeout thresholds within the broadband aggregation network.

848 objects→