Home/Catalog/GEIST-V4-MIB

GEIST-V4-MIB

The MIB for Geist Products
Main OID:
geist.1.3.6.1.4.1.21239
185
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

185 total
Object Name
geistThe MIB for Geist Products
MODULE-IDENTITY
.1.3.6.1.4.1.21239
blackbird
OBJECT IDENTIFIER
.1.3.6.1.4.1.21239.5
watchdog100
OBJECT IDENTIFIER
.1.3.6.1.4.1.21239.5.1
deviceInfo
OBJECT IDENTIFIER
.1.3.6.1.4.1.21239.5.1.1
productTitleProduct namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.1.1
productVersionProduct versionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.1.2
productFriendlyNameUser-assigned namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.1.3
productMacAddressProduct's unique MAC addressro
OCTET STRING
.1.3.6.1.4.1.21239.5.1.1.4
productUrlProduct's main URL access pointro
IpAddress
.1.3.6.1.4.1.21239.5.1.1.5
deviceCountTotal number of devices on unitro
Integer32
.1.3.6.1.4.1.21239.5.1.1.6
temperatureUnitsCurrent units for temperature values. 0 = Degrees Fahrenheit, 1 = Degrees Celsiusrw
Integer32
.1.3.6.1.4.1.21239.5.1.1.7
internalTableInternal sensors for units
SEQUENCE OF InternalEntry
.1.3.6.1.4.1.21239.5.1.2
internalEntryEntry in the internalTable table: each entry contains an index and other sensor details
InternalEntry
.1.3.6.1.4.1.21239.5.1.2.1
internalIndexTable entry index valuero
Integer32
.1.3.6.1.4.1.21239.5.1.2.1.1
internalSerialSerial Numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.2.1.2
internalNameFriendly Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.2.1.3
internalAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero
Gauge32
.1.3.6.1.4.1.21239.5.1.2.1.4
internalTempCurrent reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInforo
Integer32(-40..200) UNITS "0.1 Degrees"
.1.3.6.1.4.1.21239.5.1.2.1.5
internalHumidityHumidity readingro
Integer32
.1.3.6.1.4.1.21239.5.1.2.1.6
internalDewPointCurrent reading for Dew-point in tenths of degrees. Units are given by temperatureUnits field in deviceInforo
Integer32(-40..200) UNITS "0.1 Degrees"
.1.3.6.1.4.1.21239.5.1.2.1.7
tempSensorTableRemote Temperature Sensor
SEQUENCE OF TempSensorEntry
.1.3.6.1.4.1.21239.5.1.4
tempSensorEntryEntry in the tempSensorTable table: each entry contains an index and other sensor details
TempSensorEntry
.1.3.6.1.4.1.21239.5.1.4.1
tempSensorIndexTable entry index valuero
Integer32
.1.3.6.1.4.1.21239.5.1.4.1.1
tempSensorSerialSerial Numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.4.1.2
tempSensorNameFriendly Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.4.1.3
tempSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero
Gauge32
.1.3.6.1.4.1.21239.5.1.4.1.4
tempSensorTempCurrent reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInforo
Integer32(-40..200) UNITS "0.1 Degrees"
.1.3.6.1.4.1.21239.5.1.4.1.5
airFlowSensorTableRemote Airflow, Humidity, Temperature and Dewpoint Sensor
SEQUENCE OF AirFlowSensorEntry
.1.3.6.1.4.1.21239.5.1.5
airFlowSensorEntryEntry in the airFlowSensorTable table: each entry contains an index and other sensor details
AirFlowSensorEntry
.1.3.6.1.4.1.21239.5.1.5.1
airFlowSensorIndexTable entry index valuero
Integer32
.1.3.6.1.4.1.21239.5.1.5.1.1
airFlowSensorSerialSerial Numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.5.1.2
airFlowSensorNameFriendly Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.5.1.3
airFlowSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero
Gauge32
.1.3.6.1.4.1.21239.5.1.5.1.4
airFlowSensorTempCurrent reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInforo
Integer32(-40..200) UNITS "0.1 Degrees"
.1.3.6.1.4.1.21239.5.1.5.1.5
airFlowSensorFlowAFHT3 Airflow readingro
Integer32
.1.3.6.1.4.1.21239.5.1.5.1.6
airFlowSensorHumidityAFHT3 Humidity readingro
Integer32
.1.3.6.1.4.1.21239.5.1.5.1.7
airFlowSensorDewPointCurrent reading for Dew Point in tenths of degrees. Units are given by temperatureUnits field in deviceInforo
Integer32(-40..200) UNITS "0.1 Degrees"
.1.3.6.1.4.1.21239.5.1.5.1.8
dewPointSensorTableRemote Dew Point sensor
SEQUENCE OF DewPointSensorEntry
.1.3.6.1.4.1.21239.5.1.6
dewPointSensorEntryEntry in the dewPointSensorTable table: each entry contains an index and other sensor details
DewPointSensorEntry
.1.3.6.1.4.1.21239.5.1.6.1
dewPointSensorIndexTable entry index valuero
Integer32
.1.3.6.1.4.1.21239.5.1.6.1.1
dewPointSensorSerialSerial Numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.6.1.2
dewPointSensorNameFriendly Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.6.1.3
dewPointSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero
Gauge32
.1.3.6.1.4.1.21239.5.1.6.1.4
dewPointSensorTempCurrent reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInforo
Integer32(-40..200) UNITS "0.1 Degrees"
.1.3.6.1.4.1.21239.5.1.6.1.5
dewPointSensorHumidityHumidity readingro
Integer32
.1.3.6.1.4.1.21239.5.1.6.1.6
dewPointSensorDewPointCurrent reading for Dew-point in tenths of degrees. Units are given by temperatureUnits field in deviceInforo
Integer32(-40..200) UNITS "0.1 Degrees"
.1.3.6.1.4.1.21239.5.1.6.1.7
ccatSensorTableRemote CCAT sensor
SEQUENCE OF CcatSensorEntry
.1.3.6.1.4.1.21239.5.1.7
ccatSensorEntryEntry in the ccatSensorTable table: each entry contains an index and other sensor details
CcatSensorEntry
.1.3.6.1.4.1.21239.5.1.7.1
ccatSensorIndexTable entry index valuero
Integer32
.1.3.6.1.4.1.21239.5.1.7.1.1
ccatSensorSerialSerial Numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.7.1.2
ccatSensorNameFriendly Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.7.1.3
ccatSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero
Gauge32
.1.3.6.1.4.1.21239.5.1.7.1.4
ccatSensorValueCCAT sensor readingro
Integer32(-100..5000)
.1.3.6.1.4.1.21239.5.1.7.1.5
ccatSensorTypeCCAT sensor typero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.7.1.6
ccatSensorDescriptionCCAT sensor value descriptionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.7.1.7
t3hdSensorTableRemote Temperature x 3, Humidity and Dewpoint Sensor
SEQUENCE OF T3hdSensorEntry
.1.3.6.1.4.1.21239.5.1.8
t3hdSensorEntryEntry in the t3hdSensorTable table: each entry contains an index and other sensor details
T3hdSensorEntry
.1.3.6.1.4.1.21239.5.1.8.1
t3hdSensorIndexTable entry index valuero
Integer32
.1.3.6.1.4.1.21239.5.1.8.1.1
t3hdSensorSerialSerial Numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.8.1.2
t3hdSensorNameFriendly Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.8.1.3
t3hdSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero
Gauge32
.1.3.6.1.4.1.21239.5.1.8.1.4
t3hdSensorIntNameT3HD Sensor Internal Friendly Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.8.1.5
t3hdSensorIntTempCurrent reading for Internal Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo
Integer32(-40..200) UNITS "0.1 Degrees"
.1.3.6.1.4.1.21239.5.1.8.1.6
t3hdSensorIntHumidityT3HD Sensor Internal Humidityro
Integer32
.1.3.6.1.4.1.21239.5.1.8.1.7
t3hdSensorIntDewPointCurrent reading for Internal DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo
Integer32(-40..200) UNITS "0.1 Degrees"
.1.3.6.1.4.1.21239.5.1.8.1.8
t3hdSensorExtAAvailT3HD External A status: 0 = Unavailable, 1 = Availablero
Gauge32
.1.3.6.1.4.1.21239.5.1.8.1.9
t3hdSensorExtANameT3HD External A Friendly Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.8.1.10
t3hdSensorExtATempCurrent reading for External Temperature A in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo
Integer32(-40..200) UNITS "0.1 Degrees"
.1.3.6.1.4.1.21239.5.1.8.1.11
t3hdSensorExtBAvailT3HD External B status: 0 = Unavailable, 1 = Availablero
Gauge32
.1.3.6.1.4.1.21239.5.1.8.1.12
t3hdSensorExtBNameT3HD External B Friendly Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.8.1.13
t3hdSensorExtBTempCurrent reading for External Temperature B in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo
Integer32(-40..200) UNITS "0.1 Degrees"
.1.3.6.1.4.1.21239.5.1.8.1.14
thdSensorTableRemote Temperature, Humidity and Dewpoint Sensor
SEQUENCE OF ThdSensorEntry
.1.3.6.1.4.1.21239.5.1.9
thdSensorEntryEntry in the thdSensorTable table: each entry contains an index and other sensor details
ThdSensorEntry
.1.3.6.1.4.1.21239.5.1.9.1
thdSensorIndexTable entry index valuero
Integer32
.1.3.6.1.4.1.21239.5.1.9.1.1
thdSensorSerialSerial Numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.9.1.2
thdSensorNameFriendly Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.9.1.3
thdSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero
Gauge32
.1.3.6.1.4.1.21239.5.1.9.1.4
thdSensorTempCurrent reading for Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo
Integer32(-40..200) UNITS "0.1 Degrees"
.1.3.6.1.4.1.21239.5.1.9.1.5
thdSensorHumidityTHD Sensor Humidityro
Integer32
.1.3.6.1.4.1.21239.5.1.9.1.6
thdSensorDewPointCurrent reading for DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo
Integer32(-40..200) UNITS "0.1 Degrees"
.1.3.6.1.4.1.21239.5.1.9.1.7
rpmSensorTableRemote Power Manager Sensor
SEQUENCE OF RpmSensorEntry
.1.3.6.1.4.1.21239.5.1.10
rpmSensorEntryEntry in the rpmSensorTable table: each entry contains an index and other sensor details
RpmSensorEntry
.1.3.6.1.4.1.21239.5.1.10.1
rpmSensorIndexTable entry index valuero
Integer32
.1.3.6.1.4.1.21239.5.1.10.1.1
rpmSensorSerialSerial Numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.10.1.2
rpmSensorNameFriendly Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.10.1.3
rpmSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero
Gauge32
.1.3.6.1.4.1.21239.5.1.10.1.4
rpmSensorEnergyRPM Sensor Accumulated Energyro
Gauge32 UNITS "kWh"
.1.3.6.1.4.1.21239.5.1.10.1.5
rpmSensorVoltageRPM Sensor Voltagero
Gauge32 UNITS "Volts (rms)"
.1.3.6.1.4.1.21239.5.1.10.1.6
rpmSensorVoltageMaxRPM Sensor Voltage (Max)ro
Gauge32 UNITS "Volts (rms)"
.1.3.6.1.4.1.21239.5.1.10.1.7
rpmSensorVoltageMinRPM Sensor Voltage (Min)ro
Gauge32 UNITS "Volts (rms)"
.1.3.6.1.4.1.21239.5.1.10.1.8
rpmSensorVoltagePeakRPM Sensor Voltage (Peak)ro
Gauge32 UNITS "Volts"
.1.3.6.1.4.1.21239.5.1.10.1.9
rpmSensorCurrentRPM Sensor Current reading in deciAmpsro
Gauge32 UNITS "0.1 Amps (rms)"
.1.3.6.1.4.1.21239.5.1.10.1.10
rpmSensorRealPowerRPM Sensor Real Powerro
Gauge32 UNITS "Watts"
.1.3.6.1.4.1.21239.5.1.10.1.11
rpmSensorApparentPowerRPM Sensor Apparent Powerro
Gauge32 UNITS "Volt-Amps"
.1.3.6.1.4.1.21239.5.1.10.1.12
rpmSensorPowerFactorRPM Sensor Power Factorro
Gauge32 UNITS "%"
.1.3.6.1.4.1.21239.5.1.10.1.13
rpmSensorOutlet1RPM Sensor Outlet 1 State: 0 = off, 1 = onro
Gauge32
.1.3.6.1.4.1.21239.5.1.10.1.14
rpmSensorOutlet2RPM Sensor Outlet 2 State: 0 = off, 1 = onro
Gauge32
.1.3.6.1.4.1.21239.5.1.10.1.15
a2dSensorTableAnalog Measurement Sensor (Voltage, Current, or Dry Contact)
SEQUENCE OF A2DSensorEntry
.1.3.6.1.4.1.21239.5.1.11
a2DSensorEntryEntry in the a2dSensorTable table: each entry contains an index and other sensor details
A2DSensorEntry
.1.3.6.1.4.1.21239.5.1.11.1
a2dSensorIndexTable entry index valuero
Integer32
.1.3.6.1.4.1.21239.5.1.11.1.1
a2dSensorSerialSerial Numberro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.11.1.2
a2dSensorNameFriendly Namero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.21239.5.1.11.1.3
a2dSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero
Gauge32
.1.3.6.1.4.1.21239.5.1.11.1.4
a2dSensorValueCurrent analog measurement reading within either a user defined or preset range depending on device mode.ro
Integer32(-1000000..1000000)
.1.3.6.1.4.1.21239.5.1.11.1.5
trap
OBJECT IDENTIFIER
.1.3.6.1.4.1.21239.5.1.32767
trapPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.21239.5.1.32767.0
internalTestNOTIFYTest SNMP Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10101
internalAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10204
internalTempNOTIFYInternal Temperature Sensor Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10205
internalHumidityNOTIFYHumidity reading Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10206
internalDewPointNOTIFYInternal Dew Point Sensor Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10207
tempSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10404
tempSensorTempNOTIFYRemote Temperature Sensor Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10405
airFlowSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10504
airFlowSensorTempNOTIFYAFHT3 Sensor Temperature Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10505
airFlowSensorFlowNOTIFYAFHT3 Airflow reading Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10506
airFlowSensorHumidityNOTIFYAFHT3 Humidity reading Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10507
airFlowSensorDewPointNOTIFYAFHT3 Sensor Dew Point Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10508
dewPointSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10604
dewPointSensorTempNOTIFYRemote Dew Point Sensor Temperature Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10605
dewPointSensorHumidityNOTIFYHumidity reading Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10606
dewPointSensorDewPointNOTIFYRemote Dew Point Sensor Dew Point Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10607
ccatSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10704
ccatSensorValueNOTIFYCCAT sensor reading Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10705
t3hdSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10804
t3hdSensorIntTempNOTIFYT3HD Sensor Temperature Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10806
t3hdSensorIntHumidityNOTIFYT3HD Sensor Internal Humidity Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10807
t3hdSensorIntDewPointNOTIFYT3HD Sensor Dew Point Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10808
t3hdSensorExtATempNOTIFYT3HD Sensor External A Temperature Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10811
t3hdSensorExtBTempNOTIFYT3HD Sensor External B Temperature Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10814
thdSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10904
thdSensorTempNOTIFYTHD Sensor Temperature Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10905
thdSensorHumidityNOTIFYTHD Sensor Humidity Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10906
thdSensorDewPointNOTIFYTHD Sensor Dew Point Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.10907
rpmSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.11004
rpmSensorEnergyNOTIFYRPM Sensor Accumulated Energy Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.11005
rpmSensorVoltageNOTIFYRPM Sensor Voltage Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.11006
rpmSensorVoltageMaxNOTIFYRPM Sensor Voltage (Max) Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.11007
rpmSensorVoltageMinNOTIFYRPM Sensor Voltage (Min) Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.11008
rpmSensorVoltagePeakNOTIFYRPM Sensor Voltage (Peak) Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.11009
rpmSensorCurrentNOTIFYRPM Sensor Current Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.11010
rpmSensorRealPowerNOTIFYRPM Sensor Real Power Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.11011
rpmSensorApparentPowerNOTIFYRPM Sensor Apparent Power Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.11012
rpmSensorPowerFactorNOTIFYRPM Sensor Power Factor Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.11013
a2dSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.11104
a2dSensorValueNOTIFYA2D Analog Sensor Measurement Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.11105
internalAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20204
internalTempCLEARInternal Temperature Sensor Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20205
internalHumidityCLEARHumidity reading Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20206
internalDewPointCLEARInternal Dew Point Sensor Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20207
tempSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20404
tempSensorTempCLEARRemote Temperature Sensor Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20405
airFlowSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20504
airFlowSensorTempCLEARAFHT3 Sensor Temperature Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20505
airFlowSensorFlowCLEARAFHT3 Airflow reading Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20506
airFlowSensorHumidityCLEARAFHT3 Humidity reading Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20507
airFlowSensorDewPointCLEARAFHT3 Sensor Dew Point Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20508
dewPointSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20604
dewPointSensorTempCLEARRemote Dew Point Sensor Temperature Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20605
dewPointSensorHumidityCLEARHumidity reading Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20606
dewPointSensorDewPointCLEARRemote Dew Point Sensor Dew Point Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20607
ccatSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20704
ccatSensorValueCLEARCCAT sensor reading Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20705
t3hdSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20804
t3hdSensorIntTempCLEART3HD Sensor Temperature Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20806
t3hdSensorIntHumidityCLEART3HD Sensor Internal Humidity Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20807
t3hdSensorIntDewPointCLEART3HD Sensor Dew Point Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20808
t3hdSensorExtATempCLEART3HD Sensor External A Temperature Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20811
t3hdSensorExtBTempCLEART3HD Sensor External B Temperature Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20814
thdSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20904
thdSensorTempCLEARTHD Sensor Temperature Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20905
thdSensorHumidityCLEARTHD Sensor Humidity Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20906
thdSensorDewPointCLEARTHD Sensor Dew Point Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.20907
rpmSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.21004
rpmSensorEnergyCLEARRPM Sensor Accumulated Energy Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.21005
rpmSensorVoltageCLEARRPM Sensor Voltage Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.21006
rpmSensorVoltageMaxCLEARRPM Sensor Voltage (Max) Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.21007
rpmSensorVoltageMinCLEARRPM Sensor Voltage (Min) Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.21008
rpmSensorVoltagePeakCLEARRPM Sensor Voltage (Peak) Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.21009
rpmSensorCurrentCLEARRPM Sensor Current Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.21010
rpmSensorRealPowerCLEARRPM Sensor Real Power Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.21011
rpmSensorApparentPowerCLEARRPM Sensor Apparent Power Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.21012
rpmSensorPowerFactorCLEARRPM Sensor Power Factor Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.21013
a2dSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.21104
a2dSensorValueCLEARA2D Analog Sensor Measurement Clear Trap
NOTIFICATION-TYPE
.1.3.6.1.4.1.21239.5.1.32767.0.21105