GEIST-IMD-MIB
AI MIB Summary
The GEIST-IMD-MIB facilitates SNMP-based monitoring and management of Geist Products environmental monitoring devices, specifically tracking sensor data such as temperature, humidity, voltage, and current for rack-mounted infrastructure. It provides standardized access to alarm states and historical counter values for power distribution units (PDUs) and environmental sensors deployed in data centers.
The MIB for Geist Products
Main OID:
geist.1.3.6.1.4.1.21239
268
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
268 total| Object Name |
|---|
geistThe MIB for Geist Products MODULE-IDENTITY .1.3.6.1.4.1.21239 |
blackbird OBJECT IDENTIFIER .1.3.6.1.4.1.21239.5 |
imd OBJECT IDENTIFIER .1.3.6.1.4.1.21239.5.2 |
deviceInfo OBJECT IDENTIFIER .1.3.6.1.4.1.21239.5.2.1 |
productTitleProduct namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.1.1 |
productVersionProduct versionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.1.2 |
productFriendlyNameUser-assigned namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.1.3 |
productMacAddressProduct's unique MAC addressro OCTET STRING .1.3.6.1.4.1.21239.5.2.1.4 |
productUrlProduct's main URL access pointro IpAddress .1.3.6.1.4.1.21239.5.2.1.5 |
deviceCountTotal number of devices on unitro Integer32 .1.3.6.1.4.1.21239.5.2.1.6 |
temperatureUnitsCurrent units for temperature values. 0 = Degrees Fahrenheit, 1 = Degrees Celsiusrw Integer32 .1.3.6.1.4.1.21239.5.2.1.7 |
pdu OBJECT IDENTIFIER .1.3.6.1.4.1.21239.5.2.3 |
pduMainTablePDU general information SEQUENCE OF PduMainEntry .1.3.6.1.4.1.21239.5.2.3.1 |
pduMainEntryEntry in the pduMainTable table: each entry contains an index and other sensor details PduMainEntry .1.3.6.1.4.1.21239.5.2.3.1.1 |
pduMainIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.3.1.1.1 |
pduMainSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.1.1.2 |
pduMainNameNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.1.1.3 |
pduMainLabelLabelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.1.1.4 |
pduMainAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.3.1.1.5 |
pduMeterTypeCurrent meter type. 0 = Wye, 1 = Deltaro Integer32 .1.3.6.1.4.1.21239.5.2.3.1.1.6 |
pduTotalNameTotal Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.1.1.7 |
pduTotalLabelTotal Labelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.1.1.8 |
pduTotalRealPowerPDU Total Real Powerro Gauge32 UNITS "watts" .1.3.6.1.4.1.21239.5.2.3.1.1.9 |
pduTotalApparentPowerPDU Total Apparent Powerro Gauge32 UNITS "volt-amps" .1.3.6.1.4.1.21239.5.2.3.1.1.10 |
pduTotalPowerFactorPDU Total Power Factorro Gauge32 UNITS "%" .1.3.6.1.4.1.21239.5.2.3.1.1.11 |
pduTotalEnergyPDU Total Accumulated Energyro Gauge32 UNITS "watt-hours" .1.3.6.1.4.1.21239.5.2.3.1.1.12 |
pduPhaseTablePDU phases information SEQUENCE OF PduPhaseEntry .1.3.6.1.4.1.21239.5.2.3.2 |
pduPhaseEntryEntry in the pduPhaseTable table: each entry contains an index and other sensor details PduPhaseEntry .1.3.6.1.4.1.21239.5.2.3.2.1 |
pduPhaseIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.3.2.1.1 |
pduPhaseNamePDU Phase Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.2.1.2 |
pduPhaseLabelPDU Phase Labelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.2.1.3 |
pduPhaseVoltagePDU Phase Voltage in tenths of a voltro Gauge32 UNITS "decivolts (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.4 |
pduPhaseVoltageMaxPDU Phase Voltage (Max) in tenths of a voltro Gauge32 UNITS "decivolts (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.5 |
pduPhaseVoltageMinPDU Phase Voltage (Min) in tenths of a voltro Gauge32 UNITS "decivolts (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.6 |
pduPhaseVoltagePeakPDU Phase Voltage (Peak) in tenths of a voltro Gauge32 UNITS "decivolts" .1.3.6.1.4.1.21239.5.2.3.2.1.7 |
pduPhaseCurrentPDU Phase Current reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.8 |
pduPhaseCurrentMaxPDU Phase Current (Max) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.9 |
pduPhaseCurrentMinPDU Phase Current (Min) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.10 |
pduPhaseCurrentPeakPDU Phase Current (Peak) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.11 |
pduPhaseRealPowerPDU Phase Real Powerro Gauge32 UNITS "watts" .1.3.6.1.4.1.21239.5.2.3.2.1.12 |
pduPhaseApparentPowerPDU Phase Apparent Powerro Gauge32 UNITS "volt-amps" .1.3.6.1.4.1.21239.5.2.3.2.1.13 |
pduPhasePowerFactorPDU Phase Power Factorro Gauge32 UNITS "%" .1.3.6.1.4.1.21239.5.2.3.2.1.14 |
pduPhaseEnergyPDU Phase Accumulated Energyro Gauge32 UNITS "watt-hours" .1.3.6.1.4.1.21239.5.2.3.2.1.15 |
pduBreakerTablePDU information SEQUENCE OF PduBreakerEntry .1.3.6.1.4.1.21239.5.2.3.3 |
pduBreakerEntryEntry in the pduBreakerTable table: each entry contains an index and other sensor details PduBreakerEntry .1.3.6.1.4.1.21239.5.2.3.3.1 |
pduBreakerIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.3.3.1.1 |
pduBreakerNamePDU Breaker Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.3.1.2 |
pduBreakerLabelPDU Breaker Labelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.3.1.3 |
pduBreakerCurrentPDU Breaker Current reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.3.1.4 |
pduBreakerCurrentMaxPDU Breaker Current (Max) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.3.1.5 |
pduBreakerCurrentMinPDU Breaker Current (Min) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.3.1.6 |
pduBreakerCurrentPeakPDU Breaker Current (Peak) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.3.1.7 |
pduLineTablePDU line current information SEQUENCE OF PduLineEntry .1.3.6.1.4.1.21239.5.2.3.4 |
pduLineEntryEntry in the pduLineTable table: each entry contains an index and other sensor details PduLineEntry .1.3.6.1.4.1.21239.5.2.3.4.1 |
pduLineIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.3.4.1.1 |
pduLineNamePDU Line Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.4.1.2 |
pduLineLabelPDU Line Labelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.4.1.3 |
pduLineCurrentPDU Line Current reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.4.1.4 |
pduLineCurrentMaxPDU Line Current (Max) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.4.1.5 |
pduLineCurrentMinPDU Line Current (Min) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.4.1.6 |
pduLineCurrentPeakPDU Line Current (Peak) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.4.1.7 |
tempSensorTableRemote Temperature Sensor SEQUENCE OF TempSensorEntry .1.3.6.1.4.1.21239.5.2.4 |
tempSensorEntryEntry in the tempSensorTable table: each entry contains an index and other sensor details TempSensorEntry .1.3.6.1.4.1.21239.5.2.4.1 |
tempSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.4.1.1 |
tempSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.4.1.2 |
tempSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.4.1.3 |
tempSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.4.1.4 |
tempSensorTempCurrent reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.4.1.5 |
airFlowSensorTableRemote Airflow, Humidity, Temperature and Dewpoint Sensor SEQUENCE OF AirFlowSensorEntry .1.3.6.1.4.1.21239.5.2.5 |
airFlowSensorEntryEntry in the airFlowSensorTable table: each entry contains an index and other sensor details AirFlowSensorEntry .1.3.6.1.4.1.21239.5.2.5.1 |
airFlowSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.5.1.1 |
airFlowSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.5.1.2 |
airFlowSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.5.1.3 |
airFlowSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.5.1.4 |
airFlowSensorTempCurrent reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.5.1.5 |
airFlowSensorFlowAFHT3 Airflow readingro Integer32 .1.3.6.1.4.1.21239.5.2.5.1.6 |
airFlowSensorHumidityAFHT3 Humidity readingro Integer32 .1.3.6.1.4.1.21239.5.2.5.1.7 |
airFlowSensorDewPointCurrent reading for Dew Point in tenths of degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.5.1.8 |
dewPointSensorTableRemote Dew Point sensor SEQUENCE OF DewPointSensorEntry .1.3.6.1.4.1.21239.5.2.6 |
dewPointSensorEntryEntry in the dewPointSensorTable table: each entry contains an index and other sensor details DewPointSensorEntry .1.3.6.1.4.1.21239.5.2.6.1 |
dewPointSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.6.1.1 |
dewPointSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.6.1.2 |
dewPointSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.6.1.3 |
dewPointSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.6.1.4 |
dewPointSensorTempCurrent reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.6.1.5 |
dewPointSensorHumidityHumidity readingro Integer32 .1.3.6.1.4.1.21239.5.2.6.1.6 |
dewPointSensorDewPointCurrent reading for Dew-point in tenths of degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.6.1.7 |
ccatSensorTableRemote CCAT sensor SEQUENCE OF CcatSensorEntry .1.3.6.1.4.1.21239.5.2.7 |
ccatSensorEntryEntry in the ccatSensorTable table: each entry contains an index and other sensor details CcatSensorEntry .1.3.6.1.4.1.21239.5.2.7.1 |
ccatSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.7.1.1 |
ccatSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.7.1.2 |
ccatSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.7.1.3 |
ccatSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.7.1.4 |
ccatSensorValueCCAT sensor readingro Integer32(-100..5000) .1.3.6.1.4.1.21239.5.2.7.1.5 |
ccatSensorTypeCCAT sensor typero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.7.1.6 |
ccatSensorDescriptionCCAT sensor value descriptionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.7.1.7 |
t3hdSensorTableRemote Temperature x 3, Humidity and Dewpoint Sensor SEQUENCE OF T3hdSensorEntry .1.3.6.1.4.1.21239.5.2.8 |
t3hdSensorEntryEntry in the t3hdSensorTable table: each entry contains an index and other sensor details T3hdSensorEntry .1.3.6.1.4.1.21239.5.2.8.1 |
t3hdSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.8.1.1 |
t3hdSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.8.1.2 |
t3hdSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.8.1.3 |
t3hdSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.8.1.4 |
t3hdSensorIntNameT3HD Sensor Internal Friendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.8.1.5 |
t3hdSensorIntTempCurrent reading for Internal Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.8.1.6 |
t3hdSensorIntHumidityT3HD Sensor Internal Humidityro Integer32 .1.3.6.1.4.1.21239.5.2.8.1.7 |
t3hdSensorIntDewPointCurrent reading for Internal DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.8.1.8 |
t3hdSensorExtAAvailT3HD External A status: 0 = Unavailable, 1 = Availablero Gauge32 .1.3.6.1.4.1.21239.5.2.8.1.9 |
t3hdSensorExtANameT3HD External A Friendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.8.1.10 |
t3hdSensorExtATempCurrent reading for External Temperature A in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.8.1.11 |
t3hdSensorExtBAvailT3HD External B status: 0 = Unavailable, 1 = Availablero Gauge32 .1.3.6.1.4.1.21239.5.2.8.1.12 |
t3hdSensorExtBNameT3HD External B Friendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.8.1.13 |
t3hdSensorExtBTempCurrent reading for External Temperature B in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.8.1.14 |
thdSensorTableRemote Temperature, Humidity and Dewpoint Sensor SEQUENCE OF ThdSensorEntry .1.3.6.1.4.1.21239.5.2.9 |
thdSensorEntryEntry in the thdSensorTable table: each entry contains an index and other sensor details ThdSensorEntry .1.3.6.1.4.1.21239.5.2.9.1 |
thdSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.9.1.1 |
thdSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.9.1.2 |
thdSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.9.1.3 |
thdSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.9.1.4 |
thdSensorTempCurrent reading for Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.9.1.5 |
thdSensorHumidityTHD Sensor Humidityro Integer32 .1.3.6.1.4.1.21239.5.2.9.1.6 |
thdSensorDewPointCurrent reading for DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.9.1.7 |
rpmSensorTableRemote Power Manager Sensor SEQUENCE OF RpmSensorEntry .1.3.6.1.4.1.21239.5.2.10 |
rpmSensorEntryEntry in the rpmSensorTable table: each entry contains an index and other sensor details RpmSensorEntry .1.3.6.1.4.1.21239.5.2.10.1 |
rpmSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.10.1.1 |
rpmSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.10.1.2 |
rpmSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.10.1.3 |
rpmSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.10.1.4 |
rpmSensorEnergyRPM Sensor Accumulated Energyro Gauge32 UNITS "kWh" .1.3.6.1.4.1.21239.5.2.10.1.5 |
rpmSensorVoltageRPM Sensor Voltagero Gauge32 UNITS "Volts (rms)" .1.3.6.1.4.1.21239.5.2.10.1.6 |
rpmSensorVoltageMaxRPM Sensor Voltage (Max)ro Gauge32 UNITS "Volts (rms)" .1.3.6.1.4.1.21239.5.2.10.1.7 |
rpmSensorVoltageMinRPM Sensor Voltage (Min)ro Gauge32 UNITS "Volts (rms)" .1.3.6.1.4.1.21239.5.2.10.1.8 |
rpmSensorVoltagePeakRPM Sensor Voltage (Peak)ro Gauge32 UNITS "Volts" .1.3.6.1.4.1.21239.5.2.10.1.9 |
rpmSensorCurrentRPM Sensor Current reading in deciAmpsro Gauge32 UNITS "0.1 Amps (rms)" .1.3.6.1.4.1.21239.5.2.10.1.10 |
rpmSensorRealPowerRPM Sensor Real Powerro Gauge32 UNITS "Watts" .1.3.6.1.4.1.21239.5.2.10.1.11 |
rpmSensorApparentPowerRPM Sensor Apparent Powerro Gauge32 UNITS "Volt-Amps" .1.3.6.1.4.1.21239.5.2.10.1.12 |
rpmSensorPowerFactorRPM Sensor Power Factorro Gauge32 UNITS "%" .1.3.6.1.4.1.21239.5.2.10.1.13 |
rpmSensorOutlet1RPM Sensor Outlet 1 State: 0 = off, 1 = onro Gauge32 .1.3.6.1.4.1.21239.5.2.10.1.14 |
rpmSensorOutlet2RPM Sensor Outlet 2 State: 0 = off, 1 = onro Gauge32 .1.3.6.1.4.1.21239.5.2.10.1.15 |
a2dSensorTableAnalog Measurement Sensor (Voltage, Current, or Dry Contact) SEQUENCE OF A2DSensorEntry .1.3.6.1.4.1.21239.5.2.11 |
a2DSensorEntryEntry in the a2dSensorTable table: each entry contains an index and other sensor details A2DSensorEntry .1.3.6.1.4.1.21239.5.2.11.1 |
a2dSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.11.1.1 |
a2dSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.11.1.2 |
a2dSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.11.1.3 |
a2dSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.11.1.4 |
a2dSensorValueCurrent analog measurement reading within either a user defined or preset range depending on device mode.ro Integer32(-1000000..1000000) .1.3.6.1.4.1.21239.5.2.11.1.5 |
trap OBJECT IDENTIFIER .1.3.6.1.4.1.21239.5.2.32767 |
trapPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.21239.5.2.32767.0 |
internalTestNOTIFYTest SNMP Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10101 |
pduMainAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10305 |
pduTotalRealPowerNOTIFYPDU Total Real Power Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10309 |
pduTotalApparentPowerNOTIFYPDU Total Apparent Power Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10310 |
pduTotalPowerFactorNOTIFYPDU Total Power Factor Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10311 |
pduTotalEnergyNOTIFYPDU Total Accumulated Energy Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10312 |
pduPhaseVoltageNOTIFYPDU Phase Voltage in tenths of a volt Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10324 |
pduPhaseVoltageMaxNOTIFYPDU Phase Voltage (Max) in tenths of a volt Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10325 |
pduPhaseVoltageMinNOTIFYPDU Phase Voltage (Min) in tenths of a volt Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10326 |
pduPhaseVoltagePeakNOTIFYPDU Phase Voltage (Peak) in tenths of a volt Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10327 |
pduPhaseCurrentNOTIFYPDU Phase Current Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10328 |
pduPhaseCurrentMaxNOTIFYPDU Phase Current (Max) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10329 |
pduPhaseCurrentMinNOTIFYPDU Phase Current (Min) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10330 |
pduPhaseCurrentPeakNOTIFYPDU Phase Current (Peak) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10331 |
pduPhaseRealPowerNOTIFYPDU Phase Real Power Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10332 |
pduPhaseApparentPowerNOTIFYPDU Phase Apparent Power Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10333 |
pduPhasePowerFactorNOTIFYPDU Phase Power Factor Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10334 |
pduPhaseEnergyNOTIFYPDU Phase Accumulated Energy Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10335 |
pduBreakerCurrentNOTIFYPDU Breaker Current Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10354 |
pduBreakerCurrentMaxNOTIFYPDU Breaker Current (Max) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10355 |
pduBreakerCurrentMinNOTIFYPDU Breaker Current (Min) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10356 |
pduBreakerCurrentPeakNOTIFYPDU Breaker Current (Peak) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10357 |
pduLineCurrentNOTIFYPDU Line Current Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10374 |
pduLineCurrentMaxNOTIFYPDU Line Current (Max) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10375 |
pduLineCurrentMinNOTIFYPDU Line Current (Min) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10376 |
pduLineCurrentPeakNOTIFYPDU Line Current (Peak) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10377 |
tempSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10404 |
tempSensorTempNOTIFYRemote Temperature Sensor Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10405 |
airFlowSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10504 |
airFlowSensorTempNOTIFYAFHT3 Sensor Temperature Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10505 |
airFlowSensorFlowNOTIFYAFHT3 Airflow reading Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10506 |
airFlowSensorHumidityNOTIFYAFHT3 Humidity reading Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10507 |
airFlowSensorDewPointNOTIFYAFHT3 Sensor Dew Point Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10508 |
dewPointSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10604 |
dewPointSensorTempNOTIFYRemote Dew Point Sensor Temperature Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10605 |
dewPointSensorHumidityNOTIFYHumidity reading Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10606 |
dewPointSensorDewPointNOTIFYRemote Dew Point Sensor Dew Point Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10607 |
ccatSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10704 |
ccatSensorValueNOTIFYCCAT sensor reading Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10705 |
t3hdSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10804 |
t3hdSensorIntTempNOTIFYT3HD Sensor Temperature Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10806 |
t3hdSensorIntHumidityNOTIFYT3HD Sensor Internal Humidity Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10807 |
t3hdSensorIntDewPointNOTIFYT3HD Sensor Dew Point Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10808 |
t3hdSensorExtATempNOTIFYT3HD Sensor External A Temperature Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10811 |
t3hdSensorExtBTempNOTIFYT3HD Sensor External B Temperature Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10814 |
thdSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10904 |
thdSensorTempNOTIFYTHD Sensor Temperature Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10905 |
thdSensorHumidityNOTIFYTHD Sensor Humidity Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10906 |
thdSensorDewPointNOTIFYTHD Sensor Dew Point Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10907 |
rpmSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11004 |
rpmSensorEnergyNOTIFYRPM Sensor Accumulated Energy Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11005 |
rpmSensorVoltageNOTIFYRPM Sensor Voltage Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11006 |
rpmSensorVoltageMaxNOTIFYRPM Sensor Voltage (Max) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11007 |
rpmSensorVoltageMinNOTIFYRPM Sensor Voltage (Min) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11008 |
rpmSensorVoltagePeakNOTIFYRPM Sensor Voltage (Peak) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11009 |
rpmSensorCurrentNOTIFYRPM Sensor Current Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11010 |
rpmSensorRealPowerNOTIFYRPM Sensor Real Power Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11011 |
rpmSensorApparentPowerNOTIFYRPM Sensor Apparent Power Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11012 |
rpmSensorPowerFactorNOTIFYRPM Sensor Power Factor Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11013 |
a2dSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11104 |
a2dSensorValueNOTIFYA2D Analog Sensor Measurement Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11105 |
pduMainAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20305 |
pduTotalRealPowerCLEARPDU Total Real Power Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20309 |
pduTotalApparentPowerCLEARPDU Total Apparent Power Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20310 |
pduTotalPowerFactorCLEARPDU Total Power Factor Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20311 |
pduTotalEnergyCLEARPDU Total Accumulated Energy Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20312 |
pduPhaseVoltageCLEARPDU Phase Voltage in tenths of a volt Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20324 |
pduPhaseVoltageMaxCLEARPDU Phase Voltage (Max) in tenths of a volt Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20325 |
pduPhaseVoltageMinCLEARPDU Phase Voltage (Min) in tenths of a volt Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20326 |
pduPhaseVoltagePeakCLEARPDU Phase Voltage (Peak) in tenths of a volt Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20327 |
pduPhaseCurrentCLEARPDU Phase Current Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20328 |
pduPhaseCurrentMaxCLEARPDU Phase Current (Max) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20329 |
pduPhaseCurrentMinCLEARPDU Phase Current (Min) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20330 |
pduPhaseCurrentPeakCLEARPDU Phase Current (Peak) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20331 |
pduPhaseRealPowerCLEARPDU Phase Real Power Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20332 |
pduPhaseApparentPowerCLEARPDU Phase Apparent Power Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20333 |
pduPhasePowerFactorCLEARPDU Phase Power Factor Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20334 |
pduPhaseEnergyCLEARPDU Phase Accumulated Energy Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20335 |
pduBreakerCurrentCLEARPDU Breaker Current Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20354 |
pduBreakerCurrentMaxCLEARPDU Breaker Current (Max) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20355 |
pduBreakerCurrentMinCLEARPDU Breaker Current (Min) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20356 |
pduBreakerCurrentPeakCLEARPDU Breaker Current (Peak) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20357 |
pduLineCurrentCLEARPDU Line Current Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20374 |
pduLineCurrentMaxCLEARPDU Line Current (Max) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20375 |
pduLineCurrentMinCLEARPDU Line Current (Min) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20376 |
pduLineCurrentPeakCLEARPDU Line Current (Peak) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20377 |
tempSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20404 |
tempSensorTempCLEARRemote Temperature Sensor Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20405 |
airFlowSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20504 |
airFlowSensorTempCLEARAFHT3 Sensor Temperature Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20505 |
airFlowSensorFlowCLEARAFHT3 Airflow reading Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20506 |
airFlowSensorHumidityCLEARAFHT3 Humidity reading Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20507 |
airFlowSensorDewPointCLEARAFHT3 Sensor Dew Point Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20508 |
dewPointSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20604 |
dewPointSensorTempCLEARRemote Dew Point Sensor Temperature Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20605 |
dewPointSensorHumidityCLEARHumidity reading Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20606 |
dewPointSensorDewPointCLEARRemote Dew Point Sensor Dew Point Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20607 |
ccatSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20704 |
ccatSensorValueCLEARCCAT sensor reading Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20705 |
t3hdSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20804 |
t3hdSensorIntTempCLEART3HD Sensor Temperature Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20806 |
t3hdSensorIntHumidityCLEART3HD Sensor Internal Humidity Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20807 |
t3hdSensorIntDewPointCLEART3HD Sensor Dew Point Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20808 |
t3hdSensorExtATempCLEART3HD Sensor External A Temperature Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20811 |
t3hdSensorExtBTempCLEART3HD Sensor External B Temperature Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20814 |
thdSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20904 |
thdSensorTempCLEARTHD Sensor Temperature Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20905 |
thdSensorHumidityCLEARTHD Sensor Humidity Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20906 |
thdSensorDewPointCLEARTHD Sensor Dew Point Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20907 |
rpmSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21004 |
rpmSensorEnergyCLEARRPM Sensor Accumulated Energy Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21005 |
rpmSensorVoltageCLEARRPM Sensor Voltage Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21006 |
rpmSensorVoltageMaxCLEARRPM Sensor Voltage (Max) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21007 |
rpmSensorVoltageMinCLEARRPM Sensor Voltage (Min) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21008 |
rpmSensorVoltagePeakCLEARRPM Sensor Voltage (Peak) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21009 |
rpmSensorCurrentCLEARRPM Sensor Current Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21010 |
rpmSensorRealPowerCLEARRPM Sensor Real Power Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21011 |
rpmSensorApparentPowerCLEARRPM Sensor Apparent Power Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21012 |
rpmSensorPowerFactorCLEARRPM Sensor Power Factor Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21013 |
a2dSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21104 |
a2dSensorValueCLEARA2D Analog Sensor Measurement Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21105 |