GEIST-IMD-MIB
The GEIST-IMD-MIB facilitates SNMP-based monitoring and management of Geist Products environmental monitoring devices, specifically tracking sensor data such as temperature, humidity, voltage, and current for rack-mounted infrastructure. It provides standardized access to alarm states and historical counter values for power distribution units (PDUs) and environmental sensors deployed in data centers.
Imported Objects
Objects
268 total| Object Name |
|---|
geistThe MIB for Geist Products MODULE-IDENTITY .1.3.6.1.4.1.21239 |
blackbird OBJECT IDENTIFIER .1.3.6.1.4.1.21239.5 |
imd OBJECT IDENTIFIER .1.3.6.1.4.1.21239.5.2 |
deviceInfo OBJECT IDENTIFIER .1.3.6.1.4.1.21239.5.2.1 |
productTitleProduct namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.1.1 |
productVersionProduct versionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.1.2 |
productFriendlyNameUser-assigned namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.1.3 |
productMacAddressProduct's unique MAC addressro OCTET STRING .1.3.6.1.4.1.21239.5.2.1.4 |
productUrlProduct's main URL access pointro IpAddress .1.3.6.1.4.1.21239.5.2.1.5 |
deviceCountTotal number of devices on unitro Integer32 .1.3.6.1.4.1.21239.5.2.1.6 |
temperatureUnitsCurrent units for temperature values. 0 = Degrees Fahrenheit, 1 = Degrees Celsiusrw Integer32 .1.3.6.1.4.1.21239.5.2.1.7 |
pdu OBJECT IDENTIFIER .1.3.6.1.4.1.21239.5.2.3 |
pduMainTablePDU general information SEQUENCE OF PduMainEntry .1.3.6.1.4.1.21239.5.2.3.1 |
pduMainEntryEntry in the pduMainTable table: each entry contains an index and other sensor details PduMainEntry .1.3.6.1.4.1.21239.5.2.3.1.1 |
pduMainIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.3.1.1.1 |
pduMainSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.1.1.2 |
pduMainNameNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.1.1.3 |
pduMainLabelLabelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.1.1.4 |
pduMainAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.3.1.1.5 |
pduMeterTypeCurrent meter type. 0 = Wye, 1 = Deltaro Integer32 .1.3.6.1.4.1.21239.5.2.3.1.1.6 |
pduTotalNameTotal Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.1.1.7 |
pduTotalLabelTotal Labelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.1.1.8 |
pduTotalRealPowerPDU Total Real Powerro Gauge32 UNITS "watts" .1.3.6.1.4.1.21239.5.2.3.1.1.9 |
pduTotalApparentPowerPDU Total Apparent Powerro Gauge32 UNITS "volt-amps" .1.3.6.1.4.1.21239.5.2.3.1.1.10 |
pduTotalPowerFactorPDU Total Power Factorro Gauge32 UNITS "%" .1.3.6.1.4.1.21239.5.2.3.1.1.11 |
pduTotalEnergyPDU Total Accumulated Energyro Gauge32 UNITS "watt-hours" .1.3.6.1.4.1.21239.5.2.3.1.1.12 |
pduPhaseTablePDU phases information SEQUENCE OF PduPhaseEntry .1.3.6.1.4.1.21239.5.2.3.2 |
pduPhaseEntryEntry in the pduPhaseTable table: each entry contains an index and other sensor details PduPhaseEntry .1.3.6.1.4.1.21239.5.2.3.2.1 |
pduPhaseIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.3.2.1.1 |
pduPhaseNamePDU Phase Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.2.1.2 |
pduPhaseLabelPDU Phase Labelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.2.1.3 |
pduPhaseVoltagePDU Phase Voltage in tenths of a voltro Gauge32 UNITS "decivolts (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.4 |
pduPhaseVoltageMaxPDU Phase Voltage (Max) in tenths of a voltro Gauge32 UNITS "decivolts (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.5 |
pduPhaseVoltageMinPDU Phase Voltage (Min) in tenths of a voltro Gauge32 UNITS "decivolts (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.6 |
pduPhaseVoltagePeakPDU Phase Voltage (Peak) in tenths of a voltro Gauge32 UNITS "decivolts" .1.3.6.1.4.1.21239.5.2.3.2.1.7 |
pduPhaseCurrentPDU Phase Current reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.8 |
pduPhaseCurrentMaxPDU Phase Current (Max) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.9 |
pduPhaseCurrentMinPDU Phase Current (Min) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.10 |
pduPhaseCurrentPeakPDU Phase Current (Peak) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.2.1.11 |
pduPhaseRealPowerPDU Phase Real Powerro Gauge32 UNITS "watts" .1.3.6.1.4.1.21239.5.2.3.2.1.12 |
pduPhaseApparentPowerPDU Phase Apparent Powerro Gauge32 UNITS "volt-amps" .1.3.6.1.4.1.21239.5.2.3.2.1.13 |
pduPhasePowerFactorPDU Phase Power Factorro Gauge32 UNITS "%" .1.3.6.1.4.1.21239.5.2.3.2.1.14 |
pduPhaseEnergyPDU Phase Accumulated Energyro Gauge32 UNITS "watt-hours" .1.3.6.1.4.1.21239.5.2.3.2.1.15 |
pduBreakerTablePDU information SEQUENCE OF PduBreakerEntry .1.3.6.1.4.1.21239.5.2.3.3 |
pduBreakerEntryEntry in the pduBreakerTable table: each entry contains an index and other sensor details PduBreakerEntry .1.3.6.1.4.1.21239.5.2.3.3.1 |
pduBreakerIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.3.3.1.1 |
pduBreakerNamePDU Breaker Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.3.1.2 |
pduBreakerLabelPDU Breaker Labelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.3.1.3 |
pduBreakerCurrentPDU Breaker Current reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.3.1.4 |
pduBreakerCurrentMaxPDU Breaker Current (Max) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.3.1.5 |
pduBreakerCurrentMinPDU Breaker Current (Min) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.3.1.6 |
pduBreakerCurrentPeakPDU Breaker Current (Peak) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.3.1.7 |
pduLineTablePDU line current information SEQUENCE OF PduLineEntry .1.3.6.1.4.1.21239.5.2.3.4 |
pduLineEntryEntry in the pduLineTable table: each entry contains an index and other sensor details PduLineEntry .1.3.6.1.4.1.21239.5.2.3.4.1 |
pduLineIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.3.4.1.1 |
pduLineNamePDU Line Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.4.1.2 |
pduLineLabelPDU Line Labelro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.3.4.1.3 |
pduLineCurrentPDU Line Current reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.4.1.4 |
pduLineCurrentMaxPDU Line Current (Max) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.4.1.5 |
pduLineCurrentMinPDU Line Current (Min) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.4.1.6 |
pduLineCurrentPeakPDU Line Current (Peak) reading in hundreths of an ampro Gauge32 UNITS "centiamps (rms)" .1.3.6.1.4.1.21239.5.2.3.4.1.7 |
tempSensorTableRemote Temperature Sensor SEQUENCE OF TempSensorEntry .1.3.6.1.4.1.21239.5.2.4 |
tempSensorEntryEntry in the tempSensorTable table: each entry contains an index and other sensor details TempSensorEntry .1.3.6.1.4.1.21239.5.2.4.1 |
tempSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.4.1.1 |
tempSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.4.1.2 |
tempSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.4.1.3 |
tempSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.4.1.4 |
tempSensorTempCurrent reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.4.1.5 |
airFlowSensorTableRemote Airflow, Humidity, Temperature and Dewpoint Sensor SEQUENCE OF AirFlowSensorEntry .1.3.6.1.4.1.21239.5.2.5 |
airFlowSensorEntryEntry in the airFlowSensorTable table: each entry contains an index and other sensor details AirFlowSensorEntry .1.3.6.1.4.1.21239.5.2.5.1 |
airFlowSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.5.1.1 |
airFlowSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.5.1.2 |
airFlowSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.5.1.3 |
airFlowSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.5.1.4 |
airFlowSensorTempCurrent reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.5.1.5 |
airFlowSensorFlowAFHT3 Airflow readingro Integer32 .1.3.6.1.4.1.21239.5.2.5.1.6 |
airFlowSensorHumidityAFHT3 Humidity readingro Integer32 .1.3.6.1.4.1.21239.5.2.5.1.7 |
airFlowSensorDewPointCurrent reading for Dew Point in tenths of degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.5.1.8 |
dewPointSensorTableRemote Dew Point sensor SEQUENCE OF DewPointSensorEntry .1.3.6.1.4.1.21239.5.2.6 |
dewPointSensorEntryEntry in the dewPointSensorTable table: each entry contains an index and other sensor details DewPointSensorEntry .1.3.6.1.4.1.21239.5.2.6.1 |
dewPointSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.6.1.1 |
dewPointSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.6.1.2 |
dewPointSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.6.1.3 |
dewPointSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.6.1.4 |
dewPointSensorTempCurrent reading for Temperature in tenths of degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.6.1.5 |
dewPointSensorHumidityHumidity readingro Integer32 .1.3.6.1.4.1.21239.5.2.6.1.6 |
dewPointSensorDewPointCurrent reading for Dew-point in tenths of degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.6.1.7 |
ccatSensorTableRemote CCAT sensor SEQUENCE OF CcatSensorEntry .1.3.6.1.4.1.21239.5.2.7 |
ccatSensorEntryEntry in the ccatSensorTable table: each entry contains an index and other sensor details CcatSensorEntry .1.3.6.1.4.1.21239.5.2.7.1 |
ccatSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.7.1.1 |
ccatSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.7.1.2 |
ccatSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.7.1.3 |
ccatSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.7.1.4 |
ccatSensorValueCCAT sensor readingro Integer32(-100..5000) .1.3.6.1.4.1.21239.5.2.7.1.5 |
ccatSensorTypeCCAT sensor typero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.7.1.6 |
ccatSensorDescriptionCCAT sensor value descriptionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.7.1.7 |
t3hdSensorTableRemote Temperature x 3, Humidity and Dewpoint Sensor SEQUENCE OF T3hdSensorEntry .1.3.6.1.4.1.21239.5.2.8 |
t3hdSensorEntryEntry in the t3hdSensorTable table: each entry contains an index and other sensor details T3hdSensorEntry .1.3.6.1.4.1.21239.5.2.8.1 |
t3hdSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.8.1.1 |
t3hdSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.8.1.2 |
t3hdSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.8.1.3 |
t3hdSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.8.1.4 |
t3hdSensorIntNameT3HD Sensor Internal Friendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.8.1.5 |
t3hdSensorIntTempCurrent reading for Internal Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.8.1.6 |
t3hdSensorIntHumidityT3HD Sensor Internal Humidityro Integer32 .1.3.6.1.4.1.21239.5.2.8.1.7 |
t3hdSensorIntDewPointCurrent reading for Internal DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.8.1.8 |
t3hdSensorExtAAvailT3HD External A status: 0 = Unavailable, 1 = Availablero Gauge32 .1.3.6.1.4.1.21239.5.2.8.1.9 |
t3hdSensorExtANameT3HD External A Friendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.8.1.10 |
t3hdSensorExtATempCurrent reading for External Temperature A in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.8.1.11 |
t3hdSensorExtBAvailT3HD External B status: 0 = Unavailable, 1 = Availablero Gauge32 .1.3.6.1.4.1.21239.5.2.8.1.12 |
t3hdSensorExtBNameT3HD External B Friendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.8.1.13 |
t3hdSensorExtBTempCurrent reading for External Temperature B in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.8.1.14 |
thdSensorTableRemote Temperature, Humidity and Dewpoint Sensor SEQUENCE OF ThdSensorEntry .1.3.6.1.4.1.21239.5.2.9 |
thdSensorEntryEntry in the thdSensorTable table: each entry contains an index and other sensor details ThdSensorEntry .1.3.6.1.4.1.21239.5.2.9.1 |
thdSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.9.1.1 |
thdSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.9.1.2 |
thdSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.9.1.3 |
thdSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.9.1.4 |
thdSensorTempCurrent reading for Temperature in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.9.1.5 |
thdSensorHumidityTHD Sensor Humidityro Integer32 .1.3.6.1.4.1.21239.5.2.9.1.6 |
thdSensorDewPointCurrent reading for DewPoint in 0.1 degrees. Units are given by temperatureUnits field in deviceInforo Integer32(-40..200) UNITS "0.1 Degrees" .1.3.6.1.4.1.21239.5.2.9.1.7 |
rpmSensorTableRemote Power Manager Sensor SEQUENCE OF RpmSensorEntry .1.3.6.1.4.1.21239.5.2.10 |
rpmSensorEntryEntry in the rpmSensorTable table: each entry contains an index and other sensor details RpmSensorEntry .1.3.6.1.4.1.21239.5.2.10.1 |
rpmSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.10.1.1 |
rpmSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.10.1.2 |
rpmSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.10.1.3 |
rpmSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.10.1.4 |
rpmSensorEnergyRPM Sensor Accumulated Energyro Gauge32 UNITS "kWh" .1.3.6.1.4.1.21239.5.2.10.1.5 |
rpmSensorVoltageRPM Sensor Voltagero Gauge32 UNITS "Volts (rms)" .1.3.6.1.4.1.21239.5.2.10.1.6 |
rpmSensorVoltageMaxRPM Sensor Voltage (Max)ro Gauge32 UNITS "Volts (rms)" .1.3.6.1.4.1.21239.5.2.10.1.7 |
rpmSensorVoltageMinRPM Sensor Voltage (Min)ro Gauge32 UNITS "Volts (rms)" .1.3.6.1.4.1.21239.5.2.10.1.8 |
rpmSensorVoltagePeakRPM Sensor Voltage (Peak)ro Gauge32 UNITS "Volts" .1.3.6.1.4.1.21239.5.2.10.1.9 |
rpmSensorCurrentRPM Sensor Current reading in deciAmpsro Gauge32 UNITS "0.1 Amps (rms)" .1.3.6.1.4.1.21239.5.2.10.1.10 |
rpmSensorRealPowerRPM Sensor Real Powerro Gauge32 UNITS "Watts" .1.3.6.1.4.1.21239.5.2.10.1.11 |
rpmSensorApparentPowerRPM Sensor Apparent Powerro Gauge32 UNITS "Volt-Amps" .1.3.6.1.4.1.21239.5.2.10.1.12 |
rpmSensorPowerFactorRPM Sensor Power Factorro Gauge32 UNITS "%" .1.3.6.1.4.1.21239.5.2.10.1.13 |
rpmSensorOutlet1RPM Sensor Outlet 1 State: 0 = off, 1 = onro Gauge32 .1.3.6.1.4.1.21239.5.2.10.1.14 |
rpmSensorOutlet2RPM Sensor Outlet 2 State: 0 = off, 1 = onro Gauge32 .1.3.6.1.4.1.21239.5.2.10.1.15 |
a2dSensorTableAnalog Measurement Sensor (Voltage, Current, or Dry Contact) SEQUENCE OF A2DSensorEntry .1.3.6.1.4.1.21239.5.2.11 |
a2DSensorEntryEntry in the a2dSensorTable table: each entry contains an index and other sensor details A2DSensorEntry .1.3.6.1.4.1.21239.5.2.11.1 |
a2dSensorIndexTable entry index valuero Integer32 .1.3.6.1.4.1.21239.5.2.11.1.1 |
a2dSensorSerialSerial Numberro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.11.1.2 |
a2dSensorNameFriendly Namero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.21239.5.2.11.1.3 |
a2dSensorAvailDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailablero Gauge32 .1.3.6.1.4.1.21239.5.2.11.1.4 |
a2dSensorValueCurrent analog measurement reading within either a user defined or preset range depending on device mode.ro Integer32(-1000000..1000000) .1.3.6.1.4.1.21239.5.2.11.1.5 |
trap OBJECT IDENTIFIER .1.3.6.1.4.1.21239.5.2.32767 |
trapPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.21239.5.2.32767.0 |
internalTestNOTIFYTest SNMP Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10101 |
pduMainAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10305 |
pduTotalRealPowerNOTIFYPDU Total Real Power Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10309 |
pduTotalApparentPowerNOTIFYPDU Total Apparent Power Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10310 |
pduTotalPowerFactorNOTIFYPDU Total Power Factor Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10311 |
pduTotalEnergyNOTIFYPDU Total Accumulated Energy Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10312 |
pduPhaseVoltageNOTIFYPDU Phase Voltage in tenths of a volt Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10324 |
pduPhaseVoltageMaxNOTIFYPDU Phase Voltage (Max) in tenths of a volt Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10325 |
pduPhaseVoltageMinNOTIFYPDU Phase Voltage (Min) in tenths of a volt Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10326 |
pduPhaseVoltagePeakNOTIFYPDU Phase Voltage (Peak) in tenths of a volt Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10327 |
pduPhaseCurrentNOTIFYPDU Phase Current Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10328 |
pduPhaseCurrentMaxNOTIFYPDU Phase Current (Max) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10329 |
pduPhaseCurrentMinNOTIFYPDU Phase Current (Min) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10330 |
pduPhaseCurrentPeakNOTIFYPDU Phase Current (Peak) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10331 |
pduPhaseRealPowerNOTIFYPDU Phase Real Power Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10332 |
pduPhaseApparentPowerNOTIFYPDU Phase Apparent Power Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10333 |
pduPhasePowerFactorNOTIFYPDU Phase Power Factor Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10334 |
pduPhaseEnergyNOTIFYPDU Phase Accumulated Energy Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10335 |
pduBreakerCurrentNOTIFYPDU Breaker Current Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10354 |
pduBreakerCurrentMaxNOTIFYPDU Breaker Current (Max) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10355 |
pduBreakerCurrentMinNOTIFYPDU Breaker Current (Min) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10356 |
pduBreakerCurrentPeakNOTIFYPDU Breaker Current (Peak) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10357 |
pduLineCurrentNOTIFYPDU Line Current Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10374 |
pduLineCurrentMaxNOTIFYPDU Line Current (Max) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10375 |
pduLineCurrentMinNOTIFYPDU Line Current (Min) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10376 |
pduLineCurrentPeakNOTIFYPDU Line Current (Peak) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10377 |
tempSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10404 |
tempSensorTempNOTIFYRemote Temperature Sensor Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10405 |
airFlowSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10504 |
airFlowSensorTempNOTIFYAFHT3 Sensor Temperature Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10505 |
airFlowSensorFlowNOTIFYAFHT3 Airflow reading Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10506 |
airFlowSensorHumidityNOTIFYAFHT3 Humidity reading Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10507 |
airFlowSensorDewPointNOTIFYAFHT3 Sensor Dew Point Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10508 |
dewPointSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10604 |
dewPointSensorTempNOTIFYRemote Dew Point Sensor Temperature Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10605 |
dewPointSensorHumidityNOTIFYHumidity reading Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10606 |
dewPointSensorDewPointNOTIFYRemote Dew Point Sensor Dew Point Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10607 |
ccatSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10704 |
ccatSensorValueNOTIFYCCAT sensor reading Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10705 |
t3hdSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10804 |
t3hdSensorIntTempNOTIFYT3HD Sensor Temperature Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10806 |
t3hdSensorIntHumidityNOTIFYT3HD Sensor Internal Humidity Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10807 |
t3hdSensorIntDewPointNOTIFYT3HD Sensor Dew Point Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10808 |
t3hdSensorExtATempNOTIFYT3HD Sensor External A Temperature Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10811 |
t3hdSensorExtBTempNOTIFYT3HD Sensor External B Temperature Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10814 |
thdSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10904 |
thdSensorTempNOTIFYTHD Sensor Temperature Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10905 |
thdSensorHumidityNOTIFYTHD Sensor Humidity Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10906 |
thdSensorDewPointNOTIFYTHD Sensor Dew Point Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.10907 |
rpmSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11004 |
rpmSensorEnergyNOTIFYRPM Sensor Accumulated Energy Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11005 |
rpmSensorVoltageNOTIFYRPM Sensor Voltage Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11006 |
rpmSensorVoltageMaxNOTIFYRPM Sensor Voltage (Max) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11007 |
rpmSensorVoltageMinNOTIFYRPM Sensor Voltage (Min) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11008 |
rpmSensorVoltagePeakNOTIFYRPM Sensor Voltage (Peak) Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11009 |
rpmSensorCurrentNOTIFYRPM Sensor Current Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11010 |
rpmSensorRealPowerNOTIFYRPM Sensor Real Power Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11011 |
rpmSensorApparentPowerNOTIFYRPM Sensor Apparent Power Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11012 |
rpmSensorPowerFactorNOTIFYRPM Sensor Power Factor Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11013 |
a2dSensorAvailNOTIFYDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11104 |
a2dSensorValueNOTIFYA2D Analog Sensor Measurement Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.11105 |
pduMainAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20305 |
pduTotalRealPowerCLEARPDU Total Real Power Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20309 |
pduTotalApparentPowerCLEARPDU Total Apparent Power Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20310 |
pduTotalPowerFactorCLEARPDU Total Power Factor Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20311 |
pduTotalEnergyCLEARPDU Total Accumulated Energy Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20312 |
pduPhaseVoltageCLEARPDU Phase Voltage in tenths of a volt Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20324 |
pduPhaseVoltageMaxCLEARPDU Phase Voltage (Max) in tenths of a volt Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20325 |
pduPhaseVoltageMinCLEARPDU Phase Voltage (Min) in tenths of a volt Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20326 |
pduPhaseVoltagePeakCLEARPDU Phase Voltage (Peak) in tenths of a volt Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20327 |
pduPhaseCurrentCLEARPDU Phase Current Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20328 |
pduPhaseCurrentMaxCLEARPDU Phase Current (Max) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20329 |
pduPhaseCurrentMinCLEARPDU Phase Current (Min) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20330 |
pduPhaseCurrentPeakCLEARPDU Phase Current (Peak) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20331 |
pduPhaseRealPowerCLEARPDU Phase Real Power Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20332 |
pduPhaseApparentPowerCLEARPDU Phase Apparent Power Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20333 |
pduPhasePowerFactorCLEARPDU Phase Power Factor Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20334 |
pduPhaseEnergyCLEARPDU Phase Accumulated Energy Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20335 |
pduBreakerCurrentCLEARPDU Breaker Current Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20354 |
pduBreakerCurrentMaxCLEARPDU Breaker Current (Max) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20355 |
pduBreakerCurrentMinCLEARPDU Breaker Current (Min) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20356 |
pduBreakerCurrentPeakCLEARPDU Breaker Current (Peak) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20357 |
pduLineCurrentCLEARPDU Line Current Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20374 |
pduLineCurrentMaxCLEARPDU Line Current (Max) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20375 |
pduLineCurrentMinCLEARPDU Line Current (Min) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20376 |
pduLineCurrentPeakCLEARPDU Line Current (Peak) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20377 |
tempSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20404 |
tempSensorTempCLEARRemote Temperature Sensor Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20405 |
airFlowSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20504 |
airFlowSensorTempCLEARAFHT3 Sensor Temperature Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20505 |
airFlowSensorFlowCLEARAFHT3 Airflow reading Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20506 |
airFlowSensorHumidityCLEARAFHT3 Humidity reading Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20507 |
airFlowSensorDewPointCLEARAFHT3 Sensor Dew Point Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20508 |
dewPointSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20604 |
dewPointSensorTempCLEARRemote Dew Point Sensor Temperature Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20605 |
dewPointSensorHumidityCLEARHumidity reading Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20606 |
dewPointSensorDewPointCLEARRemote Dew Point Sensor Dew Point Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20607 |
ccatSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20704 |
ccatSensorValueCLEARCCAT sensor reading Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20705 |
t3hdSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20804 |
t3hdSensorIntTempCLEART3HD Sensor Temperature Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20806 |
t3hdSensorIntHumidityCLEART3HD Sensor Internal Humidity Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20807 |
t3hdSensorIntDewPointCLEART3HD Sensor Dew Point Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20808 |
t3hdSensorExtATempCLEART3HD Sensor External A Temperature Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20811 |
t3hdSensorExtBTempCLEART3HD Sensor External B Temperature Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20814 |
thdSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20904 |
thdSensorTempCLEARTHD Sensor Temperature Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20905 |
thdSensorHumidityCLEARTHD Sensor Humidity Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20906 |
thdSensorDewPointCLEARTHD Sensor Dew Point Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.20907 |
rpmSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21004 |
rpmSensorEnergyCLEARRPM Sensor Accumulated Energy Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21005 |
rpmSensorVoltageCLEARRPM Sensor Voltage Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21006 |
rpmSensorVoltageMaxCLEARRPM Sensor Voltage (Max) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21007 |
rpmSensorVoltageMinCLEARRPM Sensor Voltage (Min) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21008 |
rpmSensorVoltagePeakCLEARRPM Sensor Voltage (Peak) Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21009 |
rpmSensorCurrentCLEARRPM Sensor Current Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21010 |
rpmSensorRealPowerCLEARRPM Sensor Real Power Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21011 |
rpmSensorApparentPowerCLEARRPM Sensor Apparent Power Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21012 |
rpmSensorPowerFactorCLEARRPM Sensor Power Factor Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21013 |
a2dSensorAvailCLEARDevice availability. 0 = Unavailable, 1 = Available, 2 = Partially Unavailable Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21104 |
a2dSensorValueCLEARA2D Analog Sensor Measurement Clear Trap NOTIFICATION-TYPE .1.3.6.1.4.1.21239.5.2.32767.0.21105 |
More MIBs from Geist
Browse all GeistMIBs →SNMP MIB module
The VERTIV-V5-MIB module provides SNMP-based monitoring and management capabilities for Vertiv power and thermal infrastructure devices, including UPS systems, precision cooling units, and environmental sensors. It exposes critical operational metrics such as input/output voltage and current, battery status, temperature readings, fan speeds, and alarm states to facilitate real-time infrastructure health assessment.