GBNPlatformChassis-MIB
AI MIB Summary
The GBNPlatformChassis-MIB enables SNMP-based monitoring and management of GBN chassis hardware, specifically tracking critical system metrics such as power supply status, fan module health, temperature sensors, and overall chassis environmental conditions.
GBN Chassis Management Enterprise MIB definition.
Main OID:
gbnPlatformChassis.1.3.6.1.4.1.13464.1.2.1.3
54
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
54 total| Object Name |
|---|
gbnPlatformChassisGBN Chassis Management Enterprise MIB definition. MODULE-IDENTITY .1.3.6.1.4.1.13464.1.2.1.3 |
gbnChassis OBJECT IDENTIFIER .1.3.6.1.4.1.13464.1.2.1.3.1 |
chassisVersionChassis version, the format is V3.0.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13464.1.2.1.3.1.1 |
chassisSerialNoProduct Serial Number.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13464.1.2.1.3.1.2 |
chassisTypeChassis type.ro Enumeration .1.3.6.1.4.1.13464.1.2.1.3.1.3 |
chassisSlotAppTableSlots application table for control board or line board. SEQUENCE OF ChassisSlotAppEntry .1.3.6.1.4.1.13464.1.2.1.3.1.4 |
chassisSlotAppEntrySlots application table for control board or line board. ChassisSlotAppEntry .1.3.6.1.4.1.13464.1.2.1.3.1.4.1 |
slotNumSlot number of the chassis.ro INTEGER .1.3.6.1.4.1.13464.1.2.1.3.1.4.1.1 |
slotAppslots application, for control board or line board.ro Enumeration .1.3.6.1.4.1.13464.1.2.1.3.1.4.1.2 |
powerTablePower status table. SEQUENCE OF PowerEntry .1.3.6.1.4.1.13464.1.2.1.3.1.5 |
powerEntryPower table entry. PowerEntry .1.3.6.1.4.1.13464.1.2.1.3.1.5.1 |
powerIndexPower index.ro Enumeration .1.3.6.1.4.1.13464.1.2.1.3.1.5.1.1 |
powerInsertedStausPower inserted status.ro Enumeration .1.3.6.1.4.1.13464.1.2.1.3.1.5.1.2 |
powerRunningStatusPower running status.ro Enumeration .1.3.6.1.4.1.13464.1.2.1.3.1.5.1.3 |
gbnBoard OBJECT IDENTIFIER .1.3.6.1.4.1.13464.1.2.1.3.2 |
boardTableBoard table,for board management. SEQUENCE OF BoardEntry .1.3.6.1.4.1.13464.1.2.1.3.2.1 |
boardEntryboard table entry,for board management. BoardEntry .1.3.6.1.4.1.13464.1.2.1.3.2.1.1 |
boardIndexIndex of board table,corresponding to slot number.ro INTEGER .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.1 |
boardStatusStatus of board:Below four states for control board: 'noInsert(0)', 'insertAsMaster(1)' ,'insertAsSlave(2)' and insertButUnconnected(3).
Below three states for line board: 'noInsert(0)', 'insertButUnconnected(3)' and 'insertAndConnected(4)'.ro Enumeration .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.2 |
boardTypeType of board or unknown if unavailable.ro Enumeration .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.3 |
boardIfNumThe number of physical interface in line board,or 0 if unavailable.For a control board ,it's always returned 0.ro INTEGER .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.4 |
boardProdSerialNoserial number of the board,or an empty string if unavailable.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.5 |
boardSoftwarePlateSoftware Plate of the board ,or an empty string if unavailable.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.6 |
boardSoftwareVersionSoftware Version of the board,the format is V100R001B02D06P03SP3, or an empty string if unavailable.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.7 |
boardSoftwareCompiledTimeSoftware CompiledTime of the board,the format is Feburary 17 2003 15:47:00, or an empty string if unavailable.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.8 |
boardCpuDescriptionCpu description of the board,the format is Mips 32334, 133MHz, or an empty string if unavailable.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.9 |
boardFlashDescriptionFlash description of the board , format is 32M, or an empty string if unavailable.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.10 |
boardHardwareVersionHardware Version of the board,the format is V3.0, or an empty string if unavailable.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.11 |
boardBootromVersionBootrom Version of the board,the format is V2.0, or an empty string if unavailable.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.12 |
boardCpuIdleThe percentage of free CPU in the board,or 0 if unavailable.ro INTEGER .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.13 |
boardMemorySizeThe system memory size, unit is byte, or 0 if unavailable.ro INTEGER .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.14 |
boardMemoryIdleThe current system idle memory size, unit is byte, or 0 if unavailable.ro INTEGER .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.15 |
boardSysResetPerforms a hardware reset of the board. Use with care.
A 'reset(2)' resets the board,and 'noop(1)'does nothing.
A value of 'noop(1)' is always returned for a GET operation.rw Enumeration .1.3.6.1.4.1.13464.1.2.1.3.2.1.1.16 |
boardIfIndexTableInterface index table,show interface index in all connected lineboards. SEQUENCE OF BoardIfIndexEntry .1.3.6.1.4.1.13464.1.2.1.3.2.2 |
boardIfIndexEntryInterface index table,show interface index in all connected lineboards. BoardIfIndexEntry .1.3.6.1.4.1.13464.1.2.1.3.2.2.1 |
boardNumberboard number, matches boardTable boardIndex.ro INTEGER .1.3.6.1.4.1.13464.1.2.1.3.2.2.1.1 |
boardPortLocalIndexLocal index of port of the board, from 1 start, end of max port num of the board.
For example,the boardPortLocalIndex range of line1copper is 1-24.ro INTEGER .1.3.6.1.4.1.13464.1.2.1.3.2.2.1.2 |
boardIfIndexBoard interface system index, matches RFC1213/RFC2233 ifTable IfIndex.ro INTEGER .1.3.6.1.4.1.13464.1.2.1.3.2.2.1.3 |
gbnChassisTrap OBJECT IDENTIFIER .1.3.6.1.4.1.13464.1.2.1.3.3 |
powerRemoveTrapPower remove trap. NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.1 |
powerInsertTrapPower insert trap. NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.2 |
fanRemoveTrapFan remove trap. NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.3 |
fanInsertTrapFan remove trap. NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.4 |
boardRemoveTrapBoard remove trap. NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.5 |
boardInsertTrapBoard insert trap. NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.6 |
boardConnectedTrapLine board connnected trap. NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.7 |
boardUnconnectedTrapLine board unconnnect trap. NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.8 |
boardRoletoSlaveTrapTo-Slave trap. Role of the control board change to slave. NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.9 |
boardRoletoMasterTrapTo-master trap. Role of the control board change to master. NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.10 |
powerRunningNoGoodTrapPower running status is no good NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.11 |
powerRunningGoodTrapPower running status is good NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.12 |
alarmPowerNoInsertTrapA power is not inserted When the system startup is completed. NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.13 |
alarmControlNoInsertTrapA control board is not inserted When the system startup is completed. NOTIFICATION-TYPE .1.3.6.1.4.1.13464.1.2.1.3.3.14 |
gbnSwitchOverPerforms switchover of the master control board. Use with care.
A 'switchover(2)' switchover the master board,and 'noop(1)'does nothing.
A value of 'noop(1)' is always returned for a GET operation.rw Enumeration .1.3.6.1.4.1.13464.1.2.1.3.4 |