FORTINET-FORTIAP-MIB
The FORTINET-FORTIAP-MIB facilitates SNMP-based monitoring and management of Fortinet FortiAP wireless access points, exposing critical operational metrics such as radio interface statistics, client association counts, signal strength, and device health status.
Imported Objects
Objects
269 total| Object Name |
|---|
fnFortiAPMib MODULE-IDENTITY .1.3.6.1.4.1.12356.120 |
fapTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12356.120.0 |
fapDevUp NOTIFICATION-TYPE .1.3.6.1.4.1.12356.120.0.1 |
fapCpuOverload NOTIFICATION-TYPE .1.3.6.1.4.1.12356.120.0.2 |
fapMemOverload NOTIFICATION-TYPE .1.3.6.1.4.1.12356.120.0.3 |
fapDevDown NOTIFICATION-TYPE .1.3.6.1.4.1.12356.120.0.4 |
fapAcConnected NOTIFICATION-TYPE .1.3.6.1.4.1.12356.120.0.5 |
fapCommon OBJECT IDENTIFIER .1.3.6.1.4.1.12356.120.1 |
fapVersionro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.1.1 |
fapSerialNumro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.1.2 |
fapHostNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.1.3 |
fapRegionCodero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.1.4 |
fapBaseMacAddrro PhysAddress .1.3.6.1.4.1.12356.120.1.5 |
fapBiosVerro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.1.6 |
fapBiosDataVerro Integer32 .1.3.6.1.4.1.12356.120.1.7 |
fapSysPartNumro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.1.8 |
fapWTPConfig OBJECT IDENTIFIER .1.3.6.1.4.1.12356.120.2 |
fapWtpWanModerw Enumeration .1.3.6.1.4.1.12356.120.2.1 |
fapWtpApAddrModerw Enumeration .1.3.6.1.4.1.12356.120.2.2 |
fapWtpApIpAddrrw IpAddress .1.3.6.1.4.1.12356.120.2.3 |
fapWtpApIpNetmaskrw IpAddress .1.3.6.1.4.1.12356.120.2.4 |
fapWtpApIpGatewayrw IpAddress .1.3.6.1.4.1.12356.120.2.5 |
fapWtpApModerw Enumeration .1.3.6.1.4.1.12356.120.2.6 |
fapWtpApDnsAddrrw IpAddress .1.3.6.1.4.1.12356.120.2.7 |
fapWtpApStpModerw Enumeration .1.3.6.1.4.1.12356.120.2.8 |
fapWtpApMgmtVlanIDrw Integer32 .1.3.6.1.4.1.12356.120.2.9 |
fapWtpApAcDiscoveryTyperw Enumeration .1.3.6.1.4.1.12356.120.2.10 |
fapWtpApAcAddr1rw IpAddress .1.3.6.1.4.1.12356.120.2.11 |
fapWtpApAcAddr2rw IpAddress .1.3.6.1.4.1.12356.120.2.12 |
fapWtpApAcAddr3rw IpAddress .1.3.6.1.4.1.12356.120.2.13 |
fapWtpApAcHostname1rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.2.14 |
fapWtpApAcHostname2rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.2.15 |
fapWtpApAcHostname3rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.2.16 |
fapWtpAcMulticastAddrrw IpAddress .1.3.6.1.4.1.12356.120.2.17 |
fapWtpAcDhcpCoderw Integer32 .1.3.6.1.4.1.12356.120.2.18 |
fapWtpAcFcldApCtrlrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.2.19 |
fapWtpAcFcldIdrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.2.20 |
fapWtpAcFcldPasswordrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.2.21 |
fapWtpAcCtrlPortrw Integer32 .1.3.6.1.4.1.12356.120.2.22 |
fapWtpAcDataChannelSecurityrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.2.23 |
fapWtpMeshApTyperw Enumeration .1.3.6.1.4.1.12356.120.2.24 |
fapWtpMeshSSIDrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.2.25 |
fapWtpMeshPasswordrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.2.26 |
fapWtpEthBridgerw Enumeration .1.3.6.1.4.1.12356.120.2.27 |
fapWtpEthBridgeVlansrw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.2.28 |
fapLedStaterw Enumeration .1.3.6.1.4.1.12356.120.2.29 |
fapPoeModerw Enumeration .1.3.6.1.4.1.12356.120.2.30 |
fapWTPStatus OBJECT IDENTIFIER .1.3.6.1.4.1.12356.120.3 |
fapAcDiscoveryTypero Enumeration .1.3.6.1.4.1.12356.120.3.1 |
fapCtlmsgOffloadro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.3.2 |
fapAcCertVersionro Integer32 .1.3.6.1.4.1.12356.120.3.3 |
fapPoeModeOperro Enumeration .1.3.6.1.4.1.12356.120.3.4 |
fapLedModero Enumeration .1.3.6.1.4.1.12356.120.3.5 |
fapAllowAccessro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.3.6 |
fapLldpAccessro Enumeration .1.3.6.1.4.1.12356.120.3.7 |
fapRadioCountro Integer32 .1.3.6.1.4.1.12356.120.3.8 |
fapStationInforo DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.3.9 |
fapEchoIntervalro Integer32 .1.3.6.1.4.1.12356.120.3.10 |
fapKeepAliveIntervalro Integer32 .1.3.6.1.4.1.12356.120.3.11 |
fapRetransmitMaxro Integer32 .1.3.6.1.4.1.12356.120.3.12 |
fapDcDeadIntervalro Integer32 .1.3.6.1.4.1.12356.120.3.13 |
fapDiscoveryIntervalro Integer32 .1.3.6.1.4.1.12356.120.3.14 |
fapReportIntervalro Integer32 .1.3.6.1.4.1.12356.120.3.15 |
fapStationStatsIntervalro Integer32 .1.3.6.1.4.1.12356.120.3.16 |
fapVapStatsIntervalro Integer32 .1.3.6.1.4.1.12356.120.3.17 |
fapRadioStatsIntervalro Integer32 .1.3.6.1.4.1.12356.120.3.18 |
fapStationCapIntervalro Integer32 .1.3.6.1.4.1.12356.120.3.19 |
fapIdleTimeoutro Integer32 .1.3.6.1.4.1.12356.120.3.20 |
fapStatisticsIntervalro Integer32 .1.3.6.1.4.1.12356.120.3.21 |
fapFortiPresenceIntervalro Integer32 .1.3.6.1.4.1.12356.120.3.22 |
fapFsmStatero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.3.23 |
fapWtpIpAddrro IpAddress .1.3.6.1.4.1.12356.120.3.24 |
fapAcIpAddrro IpAddress .1.3.6.1.4.1.12356.120.3.25 |
fapAcPortro Integer32 .1.3.6.1.4.1.12356.120.3.26 |
fapIpFragmentPreventro Enumeration .1.3.6.1.4.1.12356.120.3.27 |
fapAeroScoutro Enumeration .1.3.6.1.4.1.12356.120.3.28 |
fapLanModero Enumeration .1.3.6.1.4.1.12356.120.3.29 |
fapLanPortCountro Integer32 .1.3.6.1.4.1.12356.120.3.30 |
fapDataChannelStatusro Enumeration .1.3.6.1.4.1.12356.120.3.31 |
fapDataChannelSecurityOperro Enumeration .1.3.6.1.4.1.12356.120.3.32 |
fapFortiPresenceServerro IpAddress .1.3.6.1.4.1.12356.120.3.33 |
fapFortiPresencePortro Integer32 .1.3.6.1.4.1.12356.120.3.34 |
fapFortiPresenceProjectro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.3.35 |
fapWtpLocationro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.3.36 |
fapFortiPresenceServerFQDNro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.3.37 |
fapWtpUptimero TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.12356.120.3.38 |
fapByteRxCountro Counter64 .1.3.6.1.4.1.12356.120.3.39 |
fapByteTxCountro Counter64 .1.3.6.1.4.1.12356.120.3.40 |
fapCpuUsagero Integer32 .1.3.6.1.4.1.12356.120.3.41 |
fapMemoryUsagero Integer32 .1.3.6.1.4.1.12356.120.3.42 |
fapStationCountro Integer32 .1.3.6.1.4.1.12356.120.3.43 |
fapTemperaturero Integer32 .1.3.6.1.4.1.12356.120.3.44 |
fapRadioTables OBJECT IDENTIFIER .1.3.6.1.4.1.12356.120.4 |
fapRadioTable SEQUENCE OF FapRadioEntry .1.3.6.1.4.1.12356.120.4.1 |
fapRadioEntry FapRadioEntry .1.3.6.1.4.1.12356.120.4.1.1 |
fapRadioIndex Integer32 .1.3.6.1.4.1.12356.120.4.1.1.1 |
fapRadioModero Enumeration .1.3.6.1.4.1.12356.120.4.1.1.2 |
fapRadioCountryro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.4.1.1.3 |
fapRadioCountryIdro Integer32 .1.3.6.1.4.1.12356.120.4.1.1.4 |
fapRadioStationInforo DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.120.4.1.1.5 |
FORTINET-FORTIAP-MIB Technical Reference Overview
The FORTINET-FORTIAP-MIB SNMP MIB module published by Fortinet defines 269 managed OID objects, including 201 scalar/column metrics, 4 SNMP tables, and 5 trap/notification events anchored at base OID .1.3.6.1.4.1.12356.120. Key tabular structures include fapRadioTable, fapStationTable, fapVapTable, fapWagTable. Monitored SNMP traps/notifications include fapAcConnected, fapCpuOverload, fapDevDown, fapDevUp, fapMemOverload.
Key OID Definitions in FORTINET-FORTIAP-MIB
.1.3.6.1.4.1.12356.120MIB module for Fortinet FortiAP devices.
.1.3.6.1.4.1.12356.120.4.1A configuration table of device's radios
.1.3.6.1.4.1.12356.120.8.1A table of connected stations on the device
.1.3.6.1.4.1.12356.120.7.1A table of virtual access point configured on the device
.1.3.6.1.4.1.12356.120.9.1A table of tunnel profiles configured on the device
.1.3.6.1.4.1.12356.120.0.5Indicates that AP has connected to the specified AC.
.1.3.6.1.4.1.12356.120.0.2Indicates that the CPU usage of the specified AP has exceeded the configured threshold.
.1.3.6.1.4.1.12356.120.0.4Indicates that the specified AP device is down.
.1.3.6.1.4.1.12356.120.0.1Indicates that the specified AP device is up.
.1.3.6.1.4.1.12356.120.0.3Indicates that the memory usage of the specified AP has exceeded the configured threshold.
.1.3.6.1.4.1.12356.120.3.3Operating AC certificate.
.1.3.6.1.4.1.12356.120.3.1Current AC Discovery type.
.1.3.6.1.4.1.12356.120.3.25IP address of the AC control channel.
.1.3.6.1.4.1.12356.120.3.26UDP port number of the AC control channel.
.1.3.6.1.4.1.12356.120.3.28AeroScout Real Time Location Service support.
.1.3.6.1.4.1.12356.120.3.6Control management access to the FortiAP.
.1.3.6.1.4.1.12356.120.1.5BaseMAC Address of the FortiAP.
.1.3.6.1.4.1.12356.120.1.7BIOS Data Version of the FortiAP.
.1.3.6.1.4.1.12356.120.1.6BIOS Version of the FortiAP.
.1.3.6.1.4.1.12356.120.3.39The RX bytes of the FortiAP.
.1.3.6.1.4.1.12356.120.3.40The TX bytes of the FortiAP.
.1.3.6.1.4.1.12356.120.3.41The current CPU usage of the FortiAP in percent.
.1.3.6.1.4.1.12356.120.3.2Display the control messages to be offloaded.
.1.3.6.1.4.1.12356.120.3.32Data Channel Security.
More MIBs from Fortinet
Browse all FortinetMIBs →The FORTINET-FORTIGATE-MIB provides SNMP access to monitor and manage FortiGate firewall and network security appliances, exposing critical operational metrics such as interface traffic counters, session states, CPU utilization, and memory usage. The specific revision noted converts non-monotonic counters to Gauge32 types to accurately reflect instantaneous device states rather than cumulative totals.
The FORTINET-FORTIEXTENDER-MIB provides SNMP management capabilities for Fortinet FortiExtender cellular gateway devices, enabling the monitoring of WAN interface status, cellular signal strength metrics (RSRP, RSRQ, SINR), and data usage counters. This module facilitates the tracking of modem state transitions, SIM card status, and network attachment states to ensure reliable cellular failover and primary link operations.
Standard SNMP MIB module defining data structures for FORTINET-MIB.
SNMP MIB module
The FORTINET-FORTIADC-MIB module provides SNMP-based monitoring and management for Fortinet Application Delivery Controllers (ADC), exposing metrics related to virtual server health, load balancing pool status, session throughput, and traffic distribution statistics. It enables network administrators to track real-time application performance, detect service failures, and analyze resource utilization across the ADC infrastructure.
The FORTINET-FORTIMANAGER-FORTIANALYZER-MIB module enables the monitoring of physical hardware sensor telemetry, including temperature, fan speed, and voltage levels, on FortiAnalyzer appliances via SNMP. This data facilitates proactive hardware health assessment and fault detection within FortiManager-managed FortiAnalyzer environments.