FORTINET-FORTIADC-MIB
AI MIB Summary
The FORTINET-FORTIADC-MIB module provides SNMP-based monitoring and management for Fortinet Application Delivery Controllers (ADC), exposing metrics related to virtual server health, load balancing pool status, session throughput, and traffic distribution statistics. It enables network administrators to track real-time application performance, detect service failures, and analyze resource utilization across the ADC infrastructure.
Initial version of FORTINET-ADC-MIB.
Main OID:
fnFortiADCMib.1.3.6.1.4.1.12356.112
378
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
378 total| Object Name |
|---|
fnFortiADCMibInitial version of FORTINET-ADC-MIB. MODULE-IDENTITY .1.3.6.1.4.1.12356.112 |
fadcTraps OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.0 |
fadcTrapCpuHighThresholdTrap sent if CPU usage becomes too high. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.101 |
fadcTrapMemLowThresholdTrap sent if memory usage becomes too high. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.102 |
fadcTrapLogDiskHighThresholdTrap sent if Log disk usage becomes too high. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.103 |
fadcTrapDosAttackStartTrap sent if DOS attack start. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.401 |
fadcTrapDosAttackStopTrap sent if DOS attack stop. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.402 |
fadcTrapFwConnectionLimitTrap sent if FW connectionhas exceeded the allowed connections. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.403 |
fadcTrapFwSnatLimitTrap sent if FW snat pool has exhausted. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.404 |
fadcTrapRequestBlockedTrap sent if the HTTP request was blocked. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.405 |
fadcTrapXSSAttackDetectedTrap sent if XSS attack detected by Signature. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.406 |
fadcTrapSQLInjectionAttackDetectedTrap sent if SQL Injection attack detected by Signature. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.407 |
fadcTrapGenericAttackDetectedTrap sent if Generic attack detected by Signature. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.408 |
fadcTrapExploitsAttackDetectedTrap sent if Know Exploits attack detected by Signature. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.409 |
fadcTrapTrojansAttackDetectedTrap sent if Trojans attack detected by Signature. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.410 |
fadcTrapInfoDisclosureAttackDetectedTrap sent if Information Disclosure attack detected by Signature. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.411 |
fadcTrapURLPattenViolateDetectedTrap sent if URL Patten violate detected. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.412 |
fadcTrapProtocolContraintDetectedTrap sent if HTTP Protocol Constraint violate detected. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.413 |
fadcTrapGeoViolateDetectedTrap sent if Geo violate detected. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.414 |
fadcTrapReputaionViolateDetectedTrap sent if IP Reputation violate detected. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.415 |
fadcTrapBotDetectedTrap sent if Bot detected NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.416 |
fadcTrapFwConnectionDenyTrap sent if Connection denied by FW_Policy NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.417 |
fadcTrapXmlDetectedTrap sent if XML violate detected NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.418 |
fadcTrapJsonDetectedTrap sent if JSON violate detected NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.419 |
fadcTrapSoapDetectedTrap sent if SOAP violate detected NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.420 |
fadcTrapCPUTempHighTrap sent if CPU temperature becomes too high. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.501 |
fadcTrapCPUTempNormalTrap sent if CPU temperature becomes normal. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.502 |
fadcTrapDeviceTempHighTrap sent if device temperature becomes too high. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.503 |
fadcTrapDeviceTempNormalTrap sent if device temperature becomes normal. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.504 |
fadcTrapPSUTempHighTrap sent if PSU temperature becomes too high. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.505 |
fadcTrapPSUTempNormalTrap sent if PSU temperature becomes normal. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.506 |
fadcTrapPSUFanSlowTrap sent if PSU fan speed becomes too slow. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.507 |
fadcTrapDeviceFanSlowTrap sent if device fan speed becomes too slow. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.508 |
fadcTrapPSUFanBadTrap sent if PSU fan becomes bad. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.509 |
fadcTrapPSUFanGoodTrap sent if PSU fan becomes good. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.510 |
fadcTrapDeviceFanBadTrap sent if device fan becomes bad. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.511 |
fadcTrapDeviceFanGoodTrap sent if device fan becomes good. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.512 |
fadcTrapVoltageHighTrap sent if voltage becomes too high. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.513 |
fadcTrapPowerSupplyHighTrap sent if power supply voltage becomes too high. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.514 |
fadcTrapPSUVoltageHighTrap sent if PSU voltage becomes too high. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.515 |
fadcTrapVoltageLowTrap sent if voltage becomes too low. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.516 |
fadcTrapPowerSupplyLowTrap sent if power supply voltage becomes too low. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.517 |
fadcTrapPSUVoltageLowTrap sent if PSU voltage becomes too low. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.518 |
fadcTrapPSUFailureTrap sent if PSU becomes failure. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.519 |
fadcTrapARPConflictTrap sent if getting ARP conflict. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.520 |
fadcTrapExternalLinkChangeTrap sent if an external interface link status changes. For a fixed port, this is an occurrence when network cables are connected or removed, and the network is reconfigured; for a pluggable port (such as a SFP or XFP port), this happens when the pluggable unit is plugged in or unplugged, or when a cable is connected or removed from a plugged port. The possible values are UP, DOWN, DISABLED, or UNPOPULATED. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.521 |
fadcTrapLogDiskCloseThresholdTrap sent if the disk partition free space is very limited, which is less than a specified limit. By default, the limit is set to 30% of total disk space. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.522 |
fadcTrapLogDiskLostTrap sent if the log disk cannot mount. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.523 |
fadcTrapSsdMwiNearThresholdTrap sent if the SSD disk wear-out indicator is near its threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.524 |
fadcTrapSsdMwiReachedThresholdTrap sent if the SSD disk wear-out indicator has reached its threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.525 |
fadcTrapHAPeerLostTrap sent if it detect peers lost in HA mode. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.526 |
fadcTrapHAMasterFailoverTrap sent if the HA-Master failover to HA-Slave in HA mode. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.527 |
fadcTrapPortStatusChangeTrap sent if the device got monitor port status changing event include up/down in HA mode. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.528 |
fadcTrapDiskStatusChangeTrap sent if the device got disk status changing event include bad/fine in HA mode. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.529 |
fadcTrapInetPortExhaustionTrap sent if The device has run out of source ports and cannot open new communications channels with other machines. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.530 |
fadcTrapCertExpireTrap sent if One of the SSL certificates configured on the device will expire soon. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.531 |
fadcTrapLogicalInterfaceUpTrap sent if Logical interfaces (system interfaces) going UP. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.532 |
fadcTrapLogicalInterfaceDownTrap sent if Logical interfaces (system interfaces) going DOWN. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.533 |
fadcTrapLogicalInterfaceDisabledTrap sent if Logical interfaces (system interfaces) going DISABLED. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.534 |
fadcTrapAlertTriggerTrap sent if a system alert be trigged NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.535 |
fadcTrapSysConnMemHighTrap sent if Connection memory usage over Threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.536 |
fadcTrapSysLincenseExpiryNotifTrap sent if License expired NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.537 |
fadcTrapSysDeviceRebootedTrap sent if System rebooted NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.538 |
fadcTrapSysDeviceStartedTrap sent if Device started NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.539 |
fadcTrapSysfadcTrapSystemUpgeadeCompleteTrap sent if System upgrade complete NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.540 |
fadcTrapSysUserLoginTrap sent if User login NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.541 |
fadcTrapSysUserLogoutTrap sent if User logout NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.542 |
fadcTrapSysDhcpIpAllocFailureTrap sent if IP address allocation failure NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.543 |
fadcTrapSysMetricsDbDiskFullTrap sent if Metrics DB Disk full NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.544 |
fadcTrapSysStatisticsDbDiskFullTrap sent if Statistics DB Disk usage full NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.545 |
fadcTrapSysLogFullTrap sent if Log disk full NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.546 |
fadcTrapSysFwBandwidthLimitTrap sent if traffic dropped due to FW QoS NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.547 |
fadcTrapConfigExecuteTrap sent if Config executed NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.548 |
fadcTrapConfigCreateTrap sent if Config create NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.549 |
fadcTrapConfigDeleteTrap sent if Config delete NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.550 |
fadcTrapConfigUpdateTrap sent if Config update NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.551 |
fadcTrapSysOcspResponseExpiresTrap sent if OCSP response expires NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.552 |
fadcTrapSysSslCertificateRevokedTrap sent if SSL certificate revoked NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.553 |
fadcTrapSysCrlExporesTrap sent if SYS CRL expires NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.554 |
fadcTrapMemberConnectionRateStartTrap sent if a pool member has exceeded the allowed connection rate. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.600 |
fadcTrapVirtualServerConnectionRateStartTrap sent if a virtual server has exceeded the allowed connection rate. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.601 |
fadcTrapMemberConnectionLimitStartTrap sent if a pool member has exceeded the allowed connections. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.602 |
fadcTrapVirtualServerConnectionLimitStartTrap sent if a virtual server has exceeded the allowed connections. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.603 |
fadcTrapMemberConnectionRateStopTrap sent if a pool member has dropping the allowed connection rate. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.604 |
fadcTrapVirtualServerConnectionRateStopTrap sent if a virtual server has dropping the allowed connection rate. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.605 |
fadcTrapMemberConnectionLimitStopTrap sent if a pool member has dropping the allowed connections. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.606 |
fadcTrapVirtualServerConnectionLimitStopTrap sent if a virtual server has dropping the allowed connections. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.607 |
fadcTrapVirtualServerTransactionRateStartTrap sent if a virtual server has exceeded the allowed transaction rate. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.608 |
fadcTrapVirtualServerTransactionRateStopTrap sent if a virtual server has dropping the allowed transaction rate. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.609 |
fadcTrapMemberHCDownTrap sent if A pool member has occurring health check down. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.610 |
fadcTrapVirtualServerHealthChangeTrap sent if a virtual server has occurring health status change. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.611 |
fadcTrapMemberHCUpTrap sent if a pool member has occurring health check up. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.612 |
fadcTrapVirtualServerAuthFailTrap sent if a virtual server has occurring authentication failure. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.613 |
fadcTrapVirtualServerIPPoolLimitTrap sent if VS ip pool has exhausted. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.614 |
adcTrapGatewayHCDownTrap sent if a link group member has occurring health check down. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.615 |
fadcTrapLinkGroupHCDownTrap sent if a link group has occurring health check down. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.616 |
fadcTrapGatewayHCUpTrap sent if a link group member has occurring health check up. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.617 |
fadcTrapLinkGroupHCUpTrap sent if a link group has occurring health check up. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.618 |
fadcTrapGatewayInboundBandwidthTrap sent if a link group member has exceeded the allowed inbound bandwidth. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.619 |
fadcTrapGatewayOutboundBandwidthTrap sent if a link group member has exceeded the allowed outbound bandwidth. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.620 |
fadcTrapGatewayInboundSpilloverTrap sent if a link group member has exceeded the allowed inbound Spillover. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.621 |
fadcTrapGatewayOutboundSpilloverTrap sent if a link group member has exceeded the allowed outbound Spillover. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.622 |
fadcTrapGatewayTotalSpilloverTrap sent if a link group member has exceeded the allowed total Spillover NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.623 |
fadcTrapGlbServerNotAvailTrap sent if a Server is becoming unavailable in global traffic management module include SLB and generic. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.624 |
fadcTrapGlbServerAvailTrap sent if a Server is becoming available in global traffic management module. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.625 |
fadcTrapGlbVSNotAvailTrap sent if A Virtual Server is becoming unavailable in global traffic management module. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.626 |
fadcTrapGlbVSAvailTrap sent if a Virtual Server is becoming available in global traffic management module. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.627 |
fadcTrapGlbGWNotAvailTrap sent if a Gateway is becoming unavailable in global traffic management module. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.633 |
fadcTrapGlbGWAvailTrap sent if a Gateway is becoming available in global traffic management module. NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.634 |
fadcTrapSlbPoolDownTrap sent if a Pool is down NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.635 |
fadcTrapSlbPoolUpTrap sent if a Pool is up NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.636 |
fadcTrapSlbPoolHealthChangeTrap sent if a Pool health check is chnage NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.637 |
fadcTrapSlbServerHealthChangeTrap sent if a Server health check is chnage NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.638 |
fadcTrapSlbServerEnabledTrap sent if a Server enabled NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.639 |
fadcTrapSlbServerDisabledTrap sent if a Server disabled NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.640 |
fadcTrapSlbServerMaintainTrap sent if a Server maintain NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.641 |
fadcTrapSlbVirtualServerDownTrap sent if a Virtual server is down NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.642 |
fadcTrapSlbVirtualServerUpTrap sent if a Virtual server is up NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.643 |
fadcTrapSlbVirtualServerEnabledTrap sent if a Virtual server is enabled NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.644 |
fadcTrapSlbVirtualServerDisabledTrap sent if a Virtual server is disabled NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.645 |
fadcTrapSlbVirtualServerMaintainTrap sent if a Virtual server is maintain NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.646 |
fadcTrapSlbFlowTblHighTrap sent if Flow table usage over Threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.647 |
fadcTrapSlbPersistTblHighTrap sent if Persistence table usage over Threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.648 |
fadcTrapSlbPktBuffHighTrap sent if Packet buffer usage over Threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.649 |
fadcTrapSlbSynCacheUsageHighTrap sent if SYN cache usage over Threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.650 |
fadcTrapSlbSynTblHighTrap sent if SYN table usage over Threshold NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.651 |
fadcTrapSlbConnDropMaxFlowTblTrap sent if connection(s) dropped due to flow table limit NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.652 |
fadcTrapSlbConnDropMaxPersistTblTrap sent if connection(s) dropped due to persistence table limit NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.653 |
fadcTrapSlbConnDropMaxSysTblTrap sent if connection(s) dropped due to SYN table limit NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.654 |
fadcTrapSlbConnDropNoConnMemTrap sent if connection(s) dropped due to SYN table limit NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.655 |
fadcTrapSlbConnDropNoPktBuffTrap sent if connection(s) dropped due to low packet buffer NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.656 |
fadcTrapSlbConnDropPoolLBFailureTrap sent if pool load balancing decision(s) failed NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.657 |
fadcTrapSlbPktDropNoPktBuffTrap sent if packet(s) dropped due to low packet buffer NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.658 |
fadcTrapSlbPktBuffAllocFailTrap sent if packet buffer allocation failure(s) NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.659 |
fadcTrapSlbCertExpireTrap sent if SSL certificate expires in NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.660 |
fadcTrapSlbCacheOBJAllocFailTrap sent if HTTP cacheable objects dropped due to memory allocation failure NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.661 |
fadcTrapLlbVirtualServerThroughputLimitTrap sent if packet(s) dropped due to virtual service bandwidth limit NOTIFICATION-TYPE .1.3.6.1.4.1.12356.112.0.662 |
fadcSystem OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.1 |
fadcSysModelSystem model string.ro DisplayString ( SIZE ( 0 .. 64 ) ) .1.3.6.1.4.1.12356.112.1.1 |
fadcSysSerialDevice serial number.ro DisplayString ( SIZE ( 0 .. 32 ) ) .1.3.6.1.4.1.12356.112.1.2 |
fadcSysVersionDevice firmware version.ro DisplayString ( SIZE ( 0 .. 128 ) ) .1.3.6.1.4.1.12356.112.1.3 |
fadcSysCpuUsageInstantaneous CPU usage.ro Gauge32 .1.3.6.1.4.1.12356.112.1.4 |
fadcSysMemUsageInstantaneous memory utilization.ro Gauge32 .1.3.6.1.4.1.12356.112.1.5 |
fadcSysLogDiskUsageInstantaneous log disk usage.ro Gauge32 .1.3.6.1.4.1.12356.112.1.6 |
fadcSysLoadInstantaneous system load.ro Gauge32 .1.3.6.1.4.1.12356.112.1.30 |
fadcSysCpuUsageTable SEQUENCE OF FadcSysCpuUsageEntry .1.3.6.1.4.1.12356.112.1.40 |
fadcSysCpuUsageEntry FadcSysCpuUsageEntry .1.3.6.1.4.1.12356.112.1.40.1 |
fadcCpuIndexCPU index used to uniquely identify rows in this table. Integer32 .1.3.6.1.4.1.12356.112.1.40.1.1 |
fadcCpuNameThe name of the CPUro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.1.40.1.2 |
fadcCpu2secAvgUsageThe average of cpu usage in 2 secro Gauge32 .1.3.6.1.4.1.12356.112.1.40.1.3 |
fadcCpu1minAvgUsageThe average of cpu usage in 1 minro Gauge32 .1.3.6.1.4.1.12356.112.1.40.1.4 |
fadcCpu5minAvgUsageThe average of cpu usage in 5 minro Gauge32 .1.3.6.1.4.1.12356.112.1.40.1.5 |
fadcSysOptions OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.1.101 |
fadcSysOptIdleTimeoutIdle period after which the administrator is automatically logged out off the system.ro Integer32 .1.3.6.1.4.1.12356.112.1.101.1 |
fadcSysHA OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.1.200 |
fadcHAMode[Discard] High-availability mode (Standalone, Active-Active, Active-Active-Vrrp or Active-Passive).ro FadcHAModeVal .1.3.6.1.4.1.12356.112.1.200.1 |
fadcSysAlert OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.1.300 |
fadcSysAlertTable SEQUENCE OF FadcSysAlertEntry .1.3.6.1.4.1.12356.112.1.300.1 |
fadcSysAlertEntry FadcSysAlertEntry .1.3.6.1.4.1.12356.112.1.300.1.1 |
fadcAlertIndexIndex of alert config. Integer32 .1.3.6.1.4.1.12356.112.1.300.1.1.1 |
fadcAlertNameThe name of the alert configro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.1.300.1.1.2 |
fadcAlertSourceType Enumeration .1.3.6.1.4.1.12356.112.1.300.1.1.3 |
fadcAlertPriority Enumeration .1.3.6.1.4.1.12356.112.1.300.1.1.4 |
fadcAlertCommentsro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.1.300.1.1.5 |
fadcAlertVdomNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.1.300.1.1.6 |
fadcVirtualDomain OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.2 |
fadcVdInfo OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.2.1 |
fadcVdNumberThe number of virtual domains in vdTable.ro Integer32 .1.3.6.1.4.1.12356.112.2.1.1 |
fadcVdMaxVdomsThe maximum number of virtual domains allowed on the device as allowed by hardware and/or licensing.ro Integer32 .1.3.6.1.4.1.12356.112.2.1.2 |
fadcVdEnabledWhether virtual domains are enabled on this device.ro FnBoolState (FORTINET-CORE-MIB) .1.3.6.1.4.1.12356.112.2.1.3 |
fadcVdTables OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.2.2 |
fadcVdTableA table of virtual domains configured on the device. SEQUENCE OF FadcVdEntry .1.3.6.1.4.1.12356.112.2.2.1 |
fadcVdEntryAn entry containing information applicable to a particular virtual domain. FadcVdEntry .1.3.6.1.4.1.12356.112.2.2.1.1 |
fadcVdEntIndexInternal virtual domain index used to uniquely identify rows in this table. This index is also used by other tables referencing a virtual domain. FadcVdIndex .1.3.6.1.4.1.12356.112.2.2.1.1.1 |
fadcVdEntNameThe name of the virtual domain.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.2.2.1.1.2 |
fadcVdEntHaStateHA cluster member state of the virtual domain on this device (master, backup or standalone).ro FadcHaState .1.3.6.1.4.1.12356.112.2.2.1.1.3 |
fadcVirtualServer OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.3 |
fadcVSNumberThe number of virtual servers in fadcVirtualServer.ro Integer32 .1.3.6.1.4.1.12356.112.3.1 |
fadcVSTableA table of virtual servers on the device. This table is intended to be extended with platform specific information. SEQUENCE OF FadcVSEntry .1.3.6.1.4.1.12356.112.3.2 |
fadcVSEntryAn entry containing information applicable to a particular virtual server. FadcVSEntry .1.3.6.1.4.1.12356.112.3.2.1 |
fadcVSIndexAn index uniquely defining a virtual server within the fadcVSTable. Integer32 .1.3.6.1.4.1.12356.112.3.2.1.1 |
fadcVSNameThe server name of the specified virtual server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.3.2.1.2 |
fadcVSStatusThe configuration status of specified virtual server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.3.2.1.3 |
fadcVSHealthThe health of specified virtual server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.3.2.1.4 |
fadcVSNewConnectionsNew Connections persecond rate for the specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.3.2.1.5 |
fadcVSConcurrentConcurrent connection rate for the specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.3.2.1.6 |
fadcVSThroughputKbpsThroughput bps rate for the specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.3.2.1.7 |
fadcVSVdomThe virtual domian of the specified virtual server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.3.2.1.8 |
fadcIntf OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.4 |
fadcIntfTableFortinet specific extensions to MIB-2 ifTable. SEQUENCE OF FadcIntfEntry .1.3.6.1.4.1.12356.112.4.1 |
fadcIntfEntryFortinet specific information about an ifEntry. This table augments the standard ifTable, so the same indexing is used. FadcIntfEntry .1.3.6.1.4.1.12356.112.4.1.1 |
fadcIntfIndexInterface index used to uniquely identify rows in this table. This index is also used by other tables referencing a virtual domain. Integer32 .1.3.6.1.4.1.12356.112.4.1.1.1 |
fadcIntfNameThe name of interface.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.4.1.1.2 |
fadcIntfVdomThe virtual domain the interface belongs to. This index corresponds to the index used by fadcVdTable.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.4.1.1.3 |
fadcAdmin OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.5 |
fadcAdminTableA table of administrator accounts on the device. SEQUENCE OF FadcAdminEntry .1.3.6.1.4.1.12356.112.5.1 |
fadcAdminEntryAn entry containing information applicable to a particular admin account. FadcAdminEntry .1.3.6.1.4.1.12356.112.5.1.1 |
fadcAdminIndexAdmin index used to uniquely identify rows in this table. This index is also used by other tables referencing a virtual domain. Integer32 .1.3.6.1.4.1.12356.112.5.1.1.1 |
fadcAdminNameThe name of administrator.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.5.1.1.2 |
fadcAdminVdomThe virtual domain the administrator belongs to.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.5.1.1.3 |
fadcHardware OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.6 |
fadcCPUInfo OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.6.1 |
fadcCPUTableA table of system related Hardware information on the device. SEQUENCE OF FadcCPUEntry .1.3.6.1.4.1.12356.112.6.1.1 |
fadcCPUEntryAn entry containing information applicable to a particular CPU. FadcCPUEntry .1.3.6.1.4.1.12356.112.6.1.1.1 |
fadcCPUIndexCPU index used to uniquely identify rows in this table. Integer32 .1.3.6.1.4.1.12356.112.6.1.1.1.1 |
fadcCPUNameThe name of the CPU.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.1.1.1.2 |
fadcCPUTempThe air temperature of the host CPU.ro Integer32 .1.3.6.1.4.1.12356.112.6.1.1.1.3 |
fadcPSUInfo OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.6.2 |
fadcPSUTableA table of system related Hardware information on the device. SEQUENCE OF FadcPSUEntry .1.3.6.1.4.1.12356.112.6.2.1 |
fadcPSUEntryAn entry containing information applicable to a particular PSU. FadcPSUEntry .1.3.6.1.4.1.12356.112.6.2.1.1 |
fadcPSUIndexPSU index used to uniquely identify rows in this table. Integer32 .1.3.6.1.4.1.12356.112.6.2.1.1.1 |
fadcPSUNameThe PSU Name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.2.1.1.2 |
fadcPSUTempThe PSU temperature.ro Integer32 .1.3.6.1.4.1.12356.112.6.2.1.1.3 |
fadcPSUFanSpeedThe PSU Fan speed.ro Integer32 .1.3.6.1.4.1.12356.112.6.2.1.1.4 |
fadcPSUFanStatusThe PSU Fan speed status. (0 for good, 1 for bad or removed)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.2.1.1.5 |
fadcPSUVoltageThe PSU voltage value.ro Integer32 .1.3.6.1.4.1.12356.112.6.2.1.1.6 |
fadcPSUStatusThe PSU status. (0 for good, 1 for bad or removed)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.2.1.1.7 |
fadcNetworkInfo OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.6.3 |
fadcNetworkTableA table of system related Hardware information on the device. SEQUENCE OF FadcNetworkEntry .1.3.6.1.4.1.12356.112.6.3.1 |
fadcNetworkEntryAn entry containing information applicable to a particular Network. FadcNetworkEntry .1.3.6.1.4.1.12356.112.6.3.1.1 |
fadcNetworkIndexPort Link index used to uniquely identify rows in this table. Integer32 .1.3.6.1.4.1.12356.112.6.3.1.1.1 |
fadcPortLinkNameThe port link name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.3.1.1.2 |
fadcPortLinkStatusThe port link status.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.3.1.1.3 |
fadcDeviceInfo OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.6.4 |
fadcDeviceTempTables OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.6.4.1 |
fadcDeviceTempTableThe Device temperature information. SEQUENCE OF FadcDeviceTempEntry .1.3.6.1.4.1.12356.112.6.4.1.1 |
fadcDeviceTempEntryAn entry containing information applicable to a particular device. FadcDeviceTempEntry .1.3.6.1.4.1.12356.112.6.4.1.1.1 |
fadcDeviceTempIndexDevice temperature index used to uniquely identify rows in this table. Integer32 .1.3.6.1.4.1.12356.112.6.4.1.1.1.1 |
fadcDeviceTempNameThe name of the device.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.4.1.1.1.2 |
fadcDeviceTempValueThe air temperature of the device.ro Integer32 .1.3.6.1.4.1.12356.112.6.4.1.1.1.3 |
fadcDeviceFanTables OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.6.4.2 |
fadcDeviceFanTableThe Device temperature information. SEQUENCE OF FadcDeviceFanEntry .1.3.6.1.4.1.12356.112.6.4.2.1 |
fadcDeviceFanEntryAn entry containing information applicable to a particular device fan. FadcDeviceFanEntry .1.3.6.1.4.1.12356.112.6.4.2.1.1 |
fadcDeviceFanIndexDevice temperature index used to uniquely identify rows in this table. Integer32 .1.3.6.1.4.1.12356.112.6.4.2.1.1.1 |
fadcDeviceFanNameThe Devcice fan name.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.4.2.1.1.2 |
fadcDeviceFanSpeedThe Device Fan speed.ro Integer32 .1.3.6.1.4.1.12356.112.6.4.2.1.1.3 |
fadcDeviceFanStatusThe Devcice fan tray status. (0 for good, 1 for bad or removed)ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.4.2.1.1.4 |
fadcHA OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.6.5 |
fadcHACurModeHigh-availability mode (Standalone, Active-Active, Active-Active-Vrrp or Active-Passive).ro FadcHAModeVal .1.3.6.1.4.1.12356.112.6.5.1 |
fadcHACurStateThe state of HA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.5.2 |
fadcHAPeerCountThe count of Peer.ro Integer32 .1.3.6.1.4.1.12356.112.6.5.3 |
fadcMoniterIntfCountThe count of Moniter Interfacero Integer32 .1.3.6.1.4.1.12356.112.6.5.4 |
fadcDiskStateThe state of disk. (0 for good, 1 for bad)ro Integer32 .1.3.6.1.4.1.12356.112.6.5.5 |
fadcHALastChangedTimeLast changed status time of HA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.5.6 |
fadcHALastChangedReasonLast changed status reason of HA.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.5.7 |
fadcSyncStats OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.6.5.20 |
fadcHASyncStatsTableA table of HA peers status SEQUENCE OF FadcHASyncStatsEntry .1.3.6.1.4.1.12356.112.6.5.20.1 |
fadcHASyncStatsEntryAn entry containing information applicable to a HA peer FadcHASyncStatsEntry .1.3.6.1.4.1.12356.112.6.5.20.1.1 |
fadcSyncTypeIndexAn index uniquely defining a sync type within the fadcHASyncStatsTable. Integer32 .1.3.6.1.4.1.12356.112.6.5.20.1.1.1 |
fadcSyncTypeThe name of sync type.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.5.20.1.1.2 |
fadcSyncSentThe number of sync pkts sent.ro Integer32 .1.3.6.1.4.1.12356.112.6.5.20.1.1.3 |
fadcSyncReceivedThe number of sync pkts received.ro Integer32 .1.3.6.1.4.1.12356.112.6.5.20.1.1.4 |
fadcDeviceErrCount OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.6.5.21 |
fadcDuplicateNodeIDThe number of duplicate node id error.ro Integer32 .1.3.6.1.4.1.12356.112.6.5.21.1 |
fadcVersionMismatchThe number of version mismatch error.ro Integer32 .1.3.6.1.4.1.12356.112.6.5.21.2 |
fadcHAPeerInfo OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.6.5.22 |
fadcHAPeerTableA table of HA peers status SEQUENCE OF FadcHAPeerEntry .1.3.6.1.4.1.12356.112.6.5.22.1 |
fadcHAPeerEntryAn entry containing information applicable to a HA peer FadcHAPeerEntry .1.3.6.1.4.1.12356.112.6.5.22.1.1 |
fadcPeerIndexAn index uniquely defining a peer within the fadcHAPeerTable. Integer32 .1.3.6.1.4.1.12356.112.6.5.22.1.1.1 |
fadcPeerSerialNumberThe serial number of peer.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.5.22.1.1.2 |
fadcPeerStatusThe status of peer.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.5.22.1.1.3 |
fadcNodeIDThe node id of peer.ro Integer32 .1.3.6.1.4.1.12356.112.6.5.22.1.1.4 |
fadcIPAddressThe ip address of peer.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.6.5.22.1.1.5 |
fadcVoltageThe Milli-Voltage value.ro Integer32 .1.3.6.1.4.1.12356.112.6.6 |
fadcPowerSupplyVoltageThe system voltage value.ro Integer32 .1.3.6.1.4.1.12356.112.6.7 |
fadcLogDiskStatusThe status of mounting log disk. ( 0: healthy, 1: not healthy, -1: Can't get status)ro Integer32 .1.3.6.1.4.1.12356.112.6.8 |
fadcSecurity OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.7 |
fadcDDoSAttackStatusCurrent DOS attack status. (1 for attacking, 0 for no attack)ro Gauge32 .1.3.6.1.4.1.12356.112.7.1 |
fadcApplication OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.8 |
fadcRS OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.8.1 |
fadcPoolNumberThe number of pools in fadcRealServer.ro Integer32 .1.3.6.1.4.1.12356.112.8.1.1 |
fadcRSNumberThe number of real servers(pool members) in fadcRealServer.ro Integer32 .1.3.6.1.4.1.12356.112.8.1.2 |
fadcRSTableA table of real servers(pool members) on the device. This table is intended to be extended with platform specific information. SEQUENCE OF FadcRSEntry .1.3.6.1.4.1.12356.112.8.1.3 |
fadcRSEntryAn entry containing information applicable to a particular real server(pool member). FadcRSEntry .1.3.6.1.4.1.12356.112.8.1.3.1 |
fadcRSIndexAn index uniquely defining a real server(pool member) within the fadcRSTable. Integer32 .1.3.6.1.4.1.12356.112.8.1.3.1.1 |
fadcPoolNameThe server name of the specified real server(pool member).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.1.3.1.2 |
fadcRSStatusThe configuration status of specified real server(pool member).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.1.3.1.3 |
fadcRSHealthThe health of specified real server(pool member).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.1.3.1.4 |
fadcRSVdomThe virtual domian of the specified real server(pool member).ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.1.3.1.5 |
fadcVS OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.8.2 |
fadcVirturalServerNumberThe number of virtual servers in fadcVirtualServer.ro Integer32 .1.3.6.1.4.1.12356.112.8.2.1 |
fadcVirturalServerTableA table of virtual servers on the device. This table is intended to be extended with platform specific information. SEQUENCE OF FadcVirturalServerEntry .1.3.6.1.4.1.12356.112.8.2.2 |
fadcVirturalServerEntryAn entry containing information applicable to a particular virtual server. FadcVirturalServerEntry .1.3.6.1.4.1.12356.112.8.2.2.1 |
fadcVirturalServerIndexAn index uniquely defining a virtual server within the fadcVSTable. Integer32 .1.3.6.1.4.1.12356.112.8.2.2.1.1 |
fadcVirturalServerNameThe server name of the specified virtual server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.2.2.1.2 |
fadcVirturalServerStatusThe configuration status of specified virtual server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.2.2.1.3 |
fadcVirturalServerHealthThe health of specified virtual server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.2.2.1.4 |
fadcVirturalServerNewConnectionsNew Connections persecond rate for the specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.8.2.2.1.5 |
fadcVirturalServerConcurrentConcurrent connection rate for the specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.8.2.2.1.6 |
fadcVirturalServerThroughputKbpsThroughput bps rate for the specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.8.2.2.1.7 |
fadcVirturalServerVdomThe virtual domian of the specified virtual server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.2.2.1.8 |
fadcVirturalServerWAFThe number of HTTP request blocked times. (The HTTP request was blocked because it issued (at least one) violation(s) which is marked as blocking at the current active policy in Application Security Module.)ro Integer32 .1.3.6.1.4.1.12356.112.8.2.2.1.9 |
fadcLinkLoadBalance OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.8.3 |
fadcGatewayTables OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.8.3.1 |
fadcGatewayTableA table of gateways on the device. This table is intended to be extended with platform specific information. SEQUENCE OF FadcGatewayEntry .1.3.6.1.4.1.12356.112.8.3.1.1 |
fadcGatewayEntryAn entry containing information applicable to a particular gateway. FadcGatewayEntry .1.3.6.1.4.1.12356.112.8.3.1.1.1 |
fadcGatewayIndexAn index uniquely defining a gateway within the fadcGatewayTable. Integer32 .1.3.6.1.4.1.12356.112.8.3.1.1.1.1 |
fadcGatewayNameThe gateway name of the specified Gateway.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.3.1.1.1.2 |
fadcGatewayHCStatusThe health check status of specified Gateway.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.3.1.1.1.3 |
fadcGatewayInboundBandWidthThe current inbound bandwidth of specified Gateway.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.3.1.1.1.4 |
fadcGatewayOutboundBandWidthThe current outbound bandwidth of specified Gateway.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.3.1.1.1.5 |
fadcGatewayVdomThe virtual domian of the specified Gateway.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.3.1.1.1.6 |
fadcLinkGroupTables OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.8.3.2 |
fadcLinkGroupTableA table of gateway groups on the device. This table is intended to be extended with platform specific information. SEQUENCE OF FadcLinkGroupEntry .1.3.6.1.4.1.12356.112.8.3.2.1 |
fadcLinkGroupEntryAn entry containing information applicable to a particular link group. FadcLinkGroupEntry .1.3.6.1.4.1.12356.112.8.3.2.1.1 |
fadcLinkGroupIndexAn index uniquely defining a real server within the fadcLinkGroupTable. Integer32 .1.3.6.1.4.1.12356.112.8.3.2.1.1.1 |
fadcLinkGroupNameThe server name of the specified Link Group.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.3.2.1.1.2 |
fadcLinkGroupHCStatusThe health of specified Link Group.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.3.2.1.1.3 |
fadcLinkGroupModeThe configuration status of specified Link Group.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.3.2.1.1.4 |
fadcLinkGroupVdomThe virtual domian of the specified Link Group.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.3.2.1.1.5 |
fadcGlobalLoadBalance OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.8.4 |
fadcGLBVSTables OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.8.4.1 |
fadcGLBVSTableA table of GLB virtual server on the device. This table is intended to be extended with platform specific information. SEQUENCE OF FadcGLBVSEntry .1.3.6.1.4.1.12356.112.8.4.1.1 |
fadcGLBVSEntryAn entry containing information applicable to a particular GLB vs. FadcGLBVSEntry .1.3.6.1.4.1.12356.112.8.4.1.1.1 |
fadcGLBVSIndexAn index uniquely defining a GLB vs within the fadcGLBVSTable. Integer32 .1.3.6.1.4.1.12356.112.8.4.1.1.1.1 |
fadcGLBVSNameThe vs name of the specified GLB vs.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.4.1.1.1.2 |
fadcGLBVSStatusThe status of specified GLB vs.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.4.1.1.1.3 |
fadcGLBVSServerNameThe vs server name of the specified GLB vs in.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.4.1.1.1.4 |
fadcGLBVSVdomThe virtual domian of the specified GLB vs.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.4.1.1.1.5 |
fadcGLBServerTables OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.8.4.2 |
fadcGLBServerTableA table of GLB server on the device. This table is intended to be extended with platform specific information. SEQUENCE OF FadcGLBServerEntry .1.3.6.1.4.1.12356.112.8.4.2.1 |
fadcGLBServerEntryAn entry containing information applicable to a particular GLB server. FadcGLBServerEntry .1.3.6.1.4.1.12356.112.8.4.2.1.1 |
fadcGLBServerIndexAn index uniquely defining a GLB server within the fadcGLBServerTable. Integer32 .1.3.6.1.4.1.12356.112.8.4.2.1.1.1 |
fadcGLBServerNameThe server name of the specified GLB server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.4.2.1.1.2 |
fadcGLBServerStatusThe status of specified GLB server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.4.2.1.1.3 |
fadcGLBServerVdomThe virtual domian of the specified GLB server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.4.2.1.1.4 |
fadcGLBGatewayTables OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.8.4.3 |
fadcGLBGatewayTableA table of GLB gateway on the device. This table is intended to be extended with platform specific information. SEQUENCE OF FadcGLBGatewayEntry .1.3.6.1.4.1.12356.112.8.4.3.1 |
fadcGLBGatewayEntryAn entry containing information applicable to a particular gateway. FadcGLBGatewayEntry .1.3.6.1.4.1.12356.112.8.4.3.1.1 |
fadcGLBGatewayIndexAn index uniquely defining a GLB gateway within the fadcGLBGatewayTable. Integer32 .1.3.6.1.4.1.12356.112.8.4.3.1.1.1 |
fadcGLBGatewayNameThe gateway name of the specified GLB gateway.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.4.3.1.1.2 |
fadcGLBGatewayStatusThe status of specified GLB gateway.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.4.3.1.1.3 |
fadcGLBGatewayServerNameThe gateway server name of the specified GLB gateway in.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.4.3.1.1.4 |
fadcGLBGatewayVdomThe virtual domian of the specified GLB gateway.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.4.3.1.1.5 |
fadcServerLoadBalance OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.8.5 |
fadcClientSideCPSClient-side connecyions per second Integer32 .1.3.6.1.4.1.12356.112.8.5.1 |
fadcClientSideRPSClient-side requests per second Integer32 .1.3.6.1.4.1.12356.112.8.5.2 |
fadcClientSideSSLCPSClient-side SSL-only connecyions per second Integer32 .1.3.6.1.4.1.12356.112.8.5.3 |
fadcClientSideSSLRPSClient-side SSL-only requests per second Integer32 .1.3.6.1.4.1.12356.112.8.5.4 |
fadcClientSideThroughputClient-side throughputingress and egress Integer32 .1.3.6.1.4.1.12356.112.8.5.5 |
fadcClientSideSSLThroughputClient-side SSL-only (encrypted) throughput Integer32 .1.3.6.1.4.1.12356.112.8.5.6 |
fadcConcurrentClientSideConnectionsConcurrent client-side connections Integer32 .1.3.6.1.4.1.12356.112.8.5.7 |
fadcConcurrentClientSideSSLSessionsConcurrent client-side SSL sessions Integer32 .1.3.6.1.4.1.12356.112.8.5.8 |
fadcClientSSLCacheUtilizationTables OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.8.5.20 |
fadcClientSSLCacheUtilizationTableClient-side SSL cache utilization table SEQUENCE OF FadcClientSSLCacheUtilizationEntry .1.3.6.1.4.1.12356.112.8.5.20.1 |
fadcClientSSLCacheUtilizationEntryAn entry containing information applicable to a particular virtual server. FadcClientSSLCacheUtilizationEntry .1.3.6.1.4.1.12356.112.8.5.20.1.1 |
fadcSLBVSIndexAn index uniquely defining a virtual server within the fadcClientSSLCacheUtilizationTable. Integer32 .1.3.6.1.4.1.12356.112.8.5.20.1.1.1 |
fadcSLBVSNameThe server name of the specified virtual server.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.12356.112.8.5.20.1.1.2 |
fadcSLBTotalCacheItemsThe total cache items of specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.8.5.20.1.1.3 |
fadcSLBTotalCacheSizeThe total cache size of specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.8.5.20.1.1.4 |
fadcSLBCacheHitCountThe cache hit count of specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.8.5.20.1.1.5 |
fadcSLBCacheHitBytesThe cache hit bytes of specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.8.5.20.1.1.6 |
fadcSLBTatalCertCacheItemsThe total certificate cache items of specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.8.5.20.1.1.7 |
fadcSLBTotalCertCacheSizeThe total certificate cache size of specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.8.5.20.1.1.8 |
fadcSLBHitCertCacheCountThe certificate cache hit count of specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.8.5.20.1.1.9 |
fadcSLBHitCertTotalCheckThe certificate cache hit total check of specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.8.5.20.1.1.10 |
fadcSLBHitCertPercentageThe certificate cache hit percentage of specified virtual server.ro Integer32 .1.3.6.1.4.1.12356.112.8.5.20.1.1.11 |
fadcModel OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100 |
fadcUnknown OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.1 |
fadcDEV OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.10 |
fadcKVM OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.20 |
fadcVM OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.30 |
fadc100D OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.101 |
fadc100F OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.103 |
fadc200D OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.201 |
fadc300D OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.301 |
fadc300E OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.302 |
fadc400D OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.401 |
fadc700D OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.701 |
fadc1000D OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.1001 |
fadc1500D OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.1501 |
fadc2000D OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.2001 |
fadc4000D OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.100.4001 |
fadcMIBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.12356.112.600 |
fadcSystemConformanceGroupObject related to FortiADC system. Unknown .1.3.6.1.4.1.12356.112.600.1 |
fadcSysOptionsConformanceGroupObject related to FortiADC system option. Unknown .1.3.6.1.4.1.12356.112.600.2 |
fadcHAModeConformanceGroupObject related to FortiADC HA mode. Unknown .1.3.6.1.4.1.12356.112.600.6 |
fadcMIBComplianceThe compliance statement for the application MIB. Unknown .1.3.6.1.4.1.12356.112.600.100 |