FLARION-TRAP-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for FLARION-TRAP-MIB.
56
Objects
Active
Status
2
Dependencies
Imported Objects
Objects
56 total| Object Name |
|---|
rrTrapVars OBJECT IDENTIFIER .1.3.6.1.4.1.8603.1.1.1 |
rrTimeStampThe time at which the event was generated. This value is expressed in seconds since 00:00:00 UTC, January 1, 1970 (see time(2)).rodeprecated INTEGER .1.3.6.1.4.1.8603.1.1.1.1 |
rrSeqNumThe event sequence number.rodeprecated INTEGER .1.3.6.1.4.1.8603.1.1.1.2 |
rrSeverityThe event severity.rodeprecated AlarmSeverity .1.3.6.1.4.1.8603.1.1.1.3 |
rrMoTypeType managed object associated with this trap.rodeprecated MoType .1.3.6.1.4.1.8603.1.1.1.4 |
rrMoIdThe instance of the managed object logical identifier.rodeprecated INTEGER .1.3.6.1.4.1.8603.1.1.1.5 |
rrAddtlInfoEvent description.rodeprecated AddtlInfo .1.3.6.1.4.1.8603.1.1.1.6 |
rrTraps OBJECT IDENTIFIER .1.3.6.1.4.1.8603.1.1.2 |
rrTrapSpecific OBJECT IDENTIFIER .1.3.6.1.4.1.8603.1.1.2.0 |
alarmTrapAlarm notification.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.1 |
bootStatusUpThe system is up and running.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.2 |
bootStatusDownThe system has failed to boot or the system is shutting down.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.3 |
mcuOperStatusMCU operational status changed.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.120 |
mcuFaultLedStatusMCU fault LED status changed.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.121 |
mcuTempStatusMCU temperature status changed.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.122 |
mcuVoltageStatusMCU voltage status changed.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.123 |
mlpppStatusMultilink PPP status changed.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.160 |
bbuOperStatusBBU operational status changed.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.200 |
bbuFaultLedStatusBBU fault LED status changed.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.201 |
bbuTempStatusBBU temperature status changed.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.202 |
bbuVoltageStatusBBU voltage status changed.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.203 |
bbuDspStatusBBU DSP status changed.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.204 |
alarmInputStatusAlarm input status changed.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.280 |
accountingRadiusStatusAccounting/RADIUS server status changed.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.1.1.2.0.350 |
flarionTraps OBJECT IDENTIFIER .1.3.6.1.4.1.8603.10 |
flaTrapVars OBJECT IDENTIFIER .1.3.6.1.4.1.8603.10.1 |
flaTimeStampThe time at which the event was generated. This value is expressed in seconds since 00:00:00 UTC, January 1, 1970 (see time(2)).ro INTEGER .1.3.6.1.4.1.8603.10.1.1 |
flaSeqNumThe event sequence number.ro INTEGER .1.3.6.1.4.1.8603.10.1.2 |
flaSeverityThe event severity.rodeprecated AlarmSeverity .1.3.6.1.4.1.8603.10.1.3 |
flaMoTypeType managed object associated with this trap.ro MoType .1.3.6.1.4.1.8603.10.1.4 |
flaMoIdThe instance of the managed object logical identifier.ro INTEGER .1.3.6.1.4.1.8603.10.1.5 |
flaAddtlInfoEvent description.ro AddtlInfo .1.3.6.1.4.1.8603.10.1.6 |
flaTraps OBJECT IDENTIFIER .1.3.6.1.4.1.8603.10.2 |
flaTrapPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.8603.10.2.0 |
mcuBootStatusUpThe MCU software is up and running. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.1 |
mcuBootStatusDownThe MCU software is shutting down. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.2 |
mcuOperStatusUpMCU operational status is up.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.3 |
mcuOperStatusDownMCU operational status is down.deprecated NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.4 |
mlpppStatusUpMultilink PPP status is up. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.5 |
mlpppStatusDownMultilink PPP status is up. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.6 |
bbuOperStatusUpBBU card operational status is up. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.7 |
bbuOperStatusDownBBU card operational status is down. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.8 |
bbuOperStatusNotPresentBBU card operational status is not present. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.9 |
bbuTempNormalBBU temperature has transitioned inot normal operating range. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.10 |
bbuTempHighBBU temperature has transitioned into a high operating range. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.11 |
bbuTempSevereBBU temperature has transitioned into a severe operating range. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.12 |
bbuTempCriticalBBU temperature has transitioned into a critical operating range. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.13 |
bbuVoltageNormalBBU voltage has transitioned into normal operating range. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.14 |
bbuVoltageHighBBU voltage has transitioned above normal operating limits. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.15 |
bbuVoltageLowBBU voltage has transitioned below normal operating limits. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.16 |
dspStatusActiveDSP has transitioned into the Active state. In this state, mobiles are allowed to establish connections and data traffic can be received/transmitted. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.17 |
dspStatusStandbyDSP has transitioned into the Disabled/Standby state. In this state, mobiles can not establish connections and data traffic can not be received/transmitted. This is typically caused by administrative intervention or the DSP has initiated this state change due to an alarm condition elsewhere in the system. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.18 |
dspStatusOosDSP has transitioned into the Out of Service state. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.19 |
dspStatusNonOperationalDSP has transitioned into the Non Operational state. This state is entered when the system is unable to determine the condition of the DSP. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.20 |
accountingRadiusUpAccounting/RADIUS server is up. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.21 |
accountingRadiusDownAccounting/RADIUS server is down. NOTIFICATION-TYPE .1.3.6.1.4.1.8603.10.2.0.22 |