Home/Catalog/FD-TRAP-MIB

FD-TRAP-MIB

AI MIB Summary

The FD-TRAP-MIB module defines SNMP trap definitions for Firepower devices to notify management systems of critical security events, including intrusion prevention system alerts, firewall policy violations, and system state changes. It enables real-time monitoring of threat detection outcomes and device operational status without requiring active polling.

Trap mib module
Main OID:
eponTraps.1.3.6.1.4.1.34592.1.3.6
20
Objects
Active
Status
8
Dependencies

Imported Objects

Objects

20 total
Object Name
eponTrapsTrap mib module
MODULE-IDENTITY
.1.3.6.1.4.1.34592.1.3.6
eponTrapsPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.34592.1.3.6.0
sniSFPStatusChangeDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.1
sniPortLinkChangeDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.2
powerStatusChangeDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.3
fanStatusChangeDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.4
ponRunningStatusChangeDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.5
onuLinkStatusChangeDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.6
onuOnlineStatusChangeDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.7
onuPortStatusChangeDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.8
swSniPortTrafficChangeDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.9
oltTrafficChangeDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.10
onuTrafficChangeDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.11
linkIdResourceExhaustDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.12
onuIdResourceExhaustDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.13
illegalRegisterAlarmDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.14
onuPortRstpStateChangeDescription.
NOTIFICATION-TYPE
.1.3.6.1.4.1.34592.1.3.6.0.15
fdTrapConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.34592.1.3.6.1
fdTrapGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.34592.1.3.6.1.1
fdTrapCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.34592.1.3.6.1.2

More MIBs from epon eoc factory

Browse all epon eoc factoryMIBs →
CDATA-GPON-MIB

The CDATA-GPON-MIB module facilitates the monitoring and management of CDATA Optical Line Terminal (OLT) and Optical Network Unit (ONU) hardware within Gigabit-capable Passive Optical Network (GPON) deployments. It exposes critical operational metrics including PON port status, optical power levels, laser bias currents, and active subscriber session counts for fault detection and performance analysis.

482 objects→
CDATA-EPON-MIB

The CDATA-EPON-MIB module enables monitoring and management of CDATA Optical Line Terminal (OLT) and Optical Network Unit (ONU) devices within Ethernet Passive Optical Network (EPON) infrastructures. It provides specific metrics for tracking PON port status, optical power levels, bandwidth allocation, and active subscriber session states to ensure service delivery integrity.

229 objects→
FD-ONU-MIB

SNMP MIB module

194 objects→
FD-OLT-MIB

The FD-OLT-MIB module facilitates the monitoring and management of Fiber Distribution Point (OLT) hardware, specifically tracking optical line terminal status, PON port states, optical power levels, and active subscriber session counts. It enables network operators to retrieve performance metrics and fault alarms for GPON/EPON interfaces to ensure service delivery integrity within the access network.

192 objects→
FD-PERFORMANCE-MIB

The FD-PERFORMANCE-MIB module provides standardized SNMP access to performance statistics for FortiGate firewalls, specifically exposing metrics such as session throughput, connection rates, and resource utilization counters for traffic analysis and capacity planning.

178 objects→
FD-SWITCH-MIB

SNMP MIB module

109 objects→