FC-TRAP-MIB
The FC-TRAP-MIB module facilitates the monitoring of Fibre Channel Topology (FC-TR) events and state transitions, specifically capturing critical trap notifications for topology changes, port state alterations, and loop initialization failures within FC-TR networks. It enables network management systems to detect and respond to topology instability, device connectivity losses, and protocol state errors in real-time.
Imported Objects
Objects
18 total| Object Name |
|---|
lucent OBJECT IDENTIFIER .1.3.6.1.4.1.1751 |
RFC1155-SMI Unknown .1.3.6.1.4.1.1751 |
RFC1213-MIB NOTIFICATION-TYPE .1.3.6.1.4.1.1751 |
products OBJECT IDENTIFIER .1.3.6.1.4.1.1751.1 |
softSwitch OBJECT IDENTIFIER .1.3.6.1.4.1.1751.1.1198 |
fcDeviceServer OBJECT IDENTIFIER .1.3.6.1.4.1.1751.1.1198.9 |
fcTrapsThe MIB module for entities implementing the xxxx
protocol. MODULE-IDENTITY .1.3.6.1.4.1.1751.1.1198.9.0 |
fcSwitchRegnErrorRegistration of FC Server with the switch for FC API services
has failed.
VARIABLE DEFINITIONS:
1. FCServer - FC server in the alarm origin field
Severity: CRITICAL NOTIFICATION-TYPE .1.3.6.1.4.1.1751.1.1198.9.0.1 |
fCSwitchRegnSuccRegistration of FC Server with the switch for FC API services
is successful.
VARIABLE DEFINITIONS:
1. FCServer - FC Server in the alarm origin field
Severity: INFO NOTIFICATION-TYPE .1.3.6.1.4.1.1751.1.1198.9.0.2 |
fcAddLLCNodeErrorThe second step of registration with the switch (add_LLC_Node)
has failed.
VARIABLE DEFINITIONS:
1. FCServer - FC Server in the alarm origin field
Severity: CRITICAL NOTIFICATION-TYPE .1.3.6.1.4.1.1751.1.1198.9.0.3 |
fcAddLLCNodeSuccThe second step of registration with the switch (add_LLC_Node) is
successful.
VARIABLE DEFINITIONS:
1. fCServer - FC Server in the alarm origin field
Severity: INFO NOTIFICATION-TYPE .1.3.6.1.4.1.1751.1.1198.9.0.4 |
fcAppStartSuccfC Application has been started successfully by the FC Server.
VARIBLE DEFINITIONS:
1. fCServer - FC Server in the alarm origin field
2. fCApp - FC Application ID to identify the application
Severity: INFO NOTIFICATION-TYPE .1.3.6.1.4.1.1751.1.1198.9.0.5 |
fcAppEndSuccFC Application has ended successfully by the FC Server.
VARIBLE DEFINITIONS:
1. fCServer - FC Server in the alarm origin field
2. fCApp - FC Application ID to identify the application
Severity: INFO NOTIFICATION-TYPE .1.3.6.1.4.1.1751.1.1198.9.0.6 |
fcAppStartErrorFC Application has failed to started by the FC Server.
VARIBLE DEFINITIONS:
1. fCServer - FC Server in the alarm origin field
2. fCApp - FC Application ID to identify the application
Severity: MAJOR NOTIFICATION-TYPE .1.3.6.1.4.1.1751.1.1198.9.0.7 |
fcAppInfoErrorThe FC Application has sent an Informational alarm to the FC Server.
VARIBLE DEFINITIONS:
1. fCServer - FC Server in the alarm origin field
2. fCApp - FC Application ID to identify the application
3. fCDescText - Application Alarm description text
Severity: INFO NOTIFICATION-TYPE .1.3.6.1.4.1.1751.1.1198.9.0.8 |
fcAppMajorErrorThe FC Application has sent a Major alarm to the FC Server.
VARIBLE DEFINITIONS:
1. fCServer - FC Server in the alarm origin field
2. fCApp - FC Application ID to identify the application
3. fCDescText - Application Alarm description text
Severity: MAJOR NOTIFICATION-TYPE .1.3.6.1.4.1.1751.1.1198.9.0.9 |
fcAppCritErrorThe FC Application has sent a Critical alarm to the FC Server.
VARIBLE DEFINITIONS:
1. FCServer - FC Server in the alarm origin field
2. FCApp - FC Application ID to identify the application
3. FCDescText - Application Alarm description text
Severity: CRITICAL NOTIFICATION-TYPE .1.3.6.1.4.1.1751.1.1198.9.0.10 |
fcUnparsedEventThe FC Application has sent a Critical alarm to the FC Server.
VARIBLE DEFINITIONS:
1. FCDescText - Application Alarm description text
Severity: CRITICAL NOTIFICATION-TYPE .1.3.6.1.4.1.1751.1.1198.9.0.11 |
More MIBs from Lucents Concord Technology Center (CTC)
Browse all Lucents Concord Technology Center (CTC)MIBs →The ACMIB module enables SNMP-based monitoring and management of Lucent Access Concentrator hardware running Release 6.2, specifically tracking interface status, port statistics, and system resource utilization for legacy DSLAM and access node deployments.
SNMP MIB module
SNMP MIB module
SNMP MIB module
SNMP MIB module
SNMP MIB module