F3-PBB-MIB
This module defines the Facility MIB definitions used by the F3 (FSP150CM/CC) product lines. Copyright (C) ADVA Optical Networking.
Main OID:
f3PBBMIB.1.3.6.1.4.1.2544.1.12.21
42
Objects
Active
Status
8
Dependencies
Imported Objects
Objects
42 total| Object Name |
|---|
f3PBBMIBThis module defines the Facility MIB definitions used by
the F3 (FSP150CM/CC) product lines.
Copyright (C) ADVA Optical Networking. MODULE-IDENTITY .1.3.6.1.4.1.2544.1.12.21 |
f3PBBConfigObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2544.1.12.21.1 |
f3PbbEthernetAccPortTableA list of entries corresponding to PBB function on the net port SEQUENCE OF F3PbbEthernetAccPortEntry .1.3.6.1.4.1.2544.1.12.21.1.1 |
f3PbbEthernetAccPortEntryA conceptual row in the f3PbbEthernetAccPortTable. F3PbbEthernetAccPortEntry .1.3.6.1.4.1.2544.1.12.21.1.1.1 |
f3PbbEthernetAccPortITagLoopbackMaskThis object allows to specify which itag loopback has been enabled.
1: Itag 1 loopback enabled, 2: Itag 2 loopback enabled, 4: Itag 4 loopback enabled.rw INTEGER .1.3.6.1.4.1.2544.1.12.21.1.1.1.1 |
f3PbbEthernetAccPortITagLoopback1This object allows specification of the Itag 1 to be looped back when port is in
vlan(terminal/facility) loopback configuration. This is valid only if the
corresponding bit in f3PbbEthernetAccPortITagLoopbackMask is set. The value
to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority.
If Y is specified as a *, all Priorities (0 to 7) are looped back.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.21.1.1.1.2 |
f3PbbEthernetAccPortITagLoopback2This object allows specification of the Itag 2 to be looped back when port is in
vlan(terminal/facility) loopback configuration. This is valid only if the
corresponding bit in f3PbbEthernetAccPortITagLoopbackMask is set. The value
to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority.
If Y is specified as a *, all Priorities (0 to 7) are looped back.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.21.1.1.1.3 |
f3PbbEthernetAccPortITagLoopback3This object allows specification of the Itag 3 to be looped back when port is in
vlan(terminal/facility) loopback configuration. This is valid only if the
corresponding bit in f3PbbEthernetAccPortITagLoopbackMask is set. The value
to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority.
If Y is specified as a *, all Priorities (0 to 7) are looped back.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.21.1.1.1.4 |
f3PbbEthernetNetPortTableA list of entries corresponding to PBB function on the net port SEQUENCE OF F3PbbEthernetNetPortEntry .1.3.6.1.4.1.2544.1.12.21.1.2 |
f3PbbEthernetNetPortEntryA conceptual row in the f3PbbEthernetNetPortTable. F3PbbEthernetNetPortEntry .1.3.6.1.4.1.2544.1.12.21.1.2.1 |
f3PbbEthernetNetPortBackboneMacAddressThis object is mac address of backbone network port.rw MacAddress (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.21.1.2.1.1 |
f3PbbEthernetNetPortITagLoopbackMaskThis object allows to specify which itag loopback has been enabled.
1: Itag 1 loopback enabled, 2: Itag 2 loopback enabled, 4: Itag 4 loopback enabled.rw INTEGER .1.3.6.1.4.1.2544.1.12.21.1.2.1.2 |
f3PbbEthernetNetPortITagLoopback1This object allows specification of the Itag 1 to be looped back when port is in
vlan(terminal/facility) loopback configuration. This is valid only if the
corresponding bit in f3PbbEthernetNetPortITagLoopbackMask is set. The value
to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority.
If Y is specified as a *, all Priorities (0 to 7) are looped back.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.21.1.2.1.3 |
f3PbbEthernetNetPortITagLoopback2This object allows specification of the Itag 2 to be looped back when port is in
vlan(terminal/facility) loopback configuration. This is valid only if the
corresponding bit in f3PbbEthernetNetPortITagLoopbackMask is set. The value
to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority.
If Y is specified as a *, all Priorities (0 to 7) are looped back.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.21.1.2.1.4 |
f3PbbEthernetNetPortITagLoopback3This object allows specification of the Itag 3 to be looped back when port is in
vlan(terminal/facility) loopback configuration. This is valid only if the
corresponding bit in f3PbbEthernetNetPortITagLoopbackMask is set. The value
to be specified should be in the form X-Y where X is the ISID and Y is the ITAG Priority.
If Y is specified as a *, all Priorities (0 to 7) are looped back.rw DisplayString (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.21.1.2.1.5 |
f3PbbFlowTableA list of entries corresponding to PBB function on the flow SEQUENCE OF F3PbbFlowEntry .1.3.6.1.4.1.2544.1.12.21.1.3 |
f3PbbFlowEntryA conceptual row in the f3PbbFlowTable. F3PbbFlowEntry .1.3.6.1.4.1.2544.1.12.21.1.3.1 |
f3PbbFlowITagControlThis object allows specification of the tag management
operation on the I-TAG. Supported types are 'none', 'push', and 'pushisid'.
and it must be none while ctagcontrol or stagcontrol is not none.rw FlowTagControl (CM-FACILITY-MIB) .1.3.6.1.4.1.2544.1.12.21.1.3.1.1 |
f3PbbFlowITagISIDThis object is used to specify the ITagISID. Its rang from 256 to 16777214.rw Integer32 .1.3.6.1.4.1.2544.1.12.21.1.3.1.2 |
f3PbbFlowITagPriorityThis object is used to specify the priority of ITag. Its rang from 0 to 7.rw Integer32 .1.3.6.1.4.1.2544.1.12.21.1.3.1.3 |
f3PbbFlowBackboneMacDestinationEnabledThis object indicates whether can assign BMAC value.
When enabled, user can assign a unicast BMAC as B_DA for this EVC
When disabled, 01-1E-83-<I-SID> will be used as B-DA.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.21.1.3.1.4 |
f3PbbFlowBackboneMacDestinationAddressCustomer can configure the backbone MAC destination address, the
default value is 01-1E-83-<I-SID>.rw MacAddress (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.21.1.3.1.5 |
f3PbbFlowA2NPbbCapableFlagWhen it is false, Drop PBB frames in the A2N direction (FPGA function),
Allow to PUSH I-TAG on this flow;
When A2NPbbCapableFlag is TRUE,
Pass PBB frames in the A2N direction (FPGA function), Software allow PUSH I-TAG on this flow(normal)
will not allow to PUSH S-TAG on this flow, will not allow to PUSH C-TAG on this flow,
Software will allow to PUSH C-TAG/S-TAG on this flow.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.21.1.3.1.6 |
f3PbbIpManagementTunnelTableA list of entries corresponding to PBB function on the mngt tunnel SEQUENCE OF F3PbbIpManagementTunnelEntry .1.3.6.1.4.1.2544.1.12.21.1.4 |
f3PbbIpManagementTunnelEntryA conceptual row in the f3PbbIpManagementTunnelTable. F3PbbIpManagementTunnelEntry .1.3.6.1.4.1.2544.1.12.21.1.4.1 |
f3PbbIpManagementTunnelItagEnabledThis object ITAG whether enabled, It is Enabled only When management tunnel type is ISID based.
By default it is disabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.21.1.4.1.1 |
f3PbbIpManagementTunnelISIDOnly applicable when iTagEnabled = enabled (ISID is shown to user, but in IFM data type here is ITAG).rw Integer32 .1.3.6.1.4.1.2544.1.12.21.1.4.1.2 |
f3PbbIpManagementTunnelIPriorityOnly applicable when iTagEnabled = enabled (ISID is shown to user, but in IFM data type here is ITAG, no use at present).rw Integer32 .1.3.6.1.4.1.2544.1.12.21.1.4.1.3 |
f3PbbIpManagementTunnelBackboneMacDestinationEnabledWhen enabled, we will use provisioned B-MAC for ARP and for management packets.
When disabled, we will use backbone group MAC address for ARP and get B-DA from ARP response
By default, it is disabledrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.21.1.4.1.4 |
f3PbbIpManagementTunnelBackboneMacDestinationAddressUser must set a valid MAC address, Only applicable when iTagEnabled = enabled
By default, it is 00:00:00:00:00:00rw MacAddress (SNMPv2-TC) .1.3.6.1.4.1.2544.1.12.21.1.4.1.5 |
f3PBBPerformanceObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2544.1.12.21.2 |
f3PbbEthernetNetPortStatsTableA collection of pbb Ethernet Network Port related statistics.
These reflect the current data. SEQUENCE OF F3PbbEthernetNetPortStatsEntry .1.3.6.1.4.1.2544.1.12.21.2.1 |
f3PbbEthernetNetPortStatsEntryA conceptual row in the f3PbbEthernetNetPortStatsTable.
Entries exist in this table for each Ethernet interface/port. F3PbbEthernetNetPortStatsEntry .1.3.6.1.4.1.2544.1.12.21.2.1.1 |
f3PbbEthernetNetPortStatsPbbUniBdaDiscardNumber of PBB frames (BDA is not backbone group MAC)
discarded due to receive BDA which is not matching the
port's PBB MAC address when port is non-promiscuous mode.ro PerfCounter64 (CM-COMMON-MIB) .1.3.6.1.4.1.2544.1.12.21.2.1.1.1 |
f3PbbEthernetNetPortStatsPbbGroupBdaDiscardNumber of PBB frames discarded due to mismatch of I-SID in I-TAG and I-SID
in backbone group MAC in the B-DA when port is non-promiscuous mode.ro PerfCounter64 (CM-COMMON-MIB) .1.3.6.1.4.1.2544.1.12.21.2.1.1.2 |
f3PbbEthernetNetPortHistoryStatsTableA collection of pbb Ethernet Network Port related statistics.
These reflect the current data. SEQUENCE OF F3PbbEthernetNetPortHistoryStatsEntry .1.3.6.1.4.1.2544.1.12.21.2.2 |
f3PbbEthernetNetPortHistoryStatsEntryA conceptual row in the f3PbbEthernetNetPortHistoryStatsTable.
Entries exist in this table for each Ethernet interface/port. F3PbbEthernetNetPortHistoryStatsEntry .1.3.6.1.4.1.2544.1.12.21.2.2.1 |
f3PbbEthernetNetPortHistoryStatsPbbUniBdaDiscardNumber of PBB frames (BDA is not backbone group MAC)
discarded due to receive BDA which is not matching the
port's PBB MAC address when port is non-promiscuous mode.ro PerfCounter64 (CM-COMMON-MIB) .1.3.6.1.4.1.2544.1.12.21.2.2.1.1 |
f3PbbEthernetNetPortHistoryStatsPbbGroupBdaDiscardNumber of PBB frames discarded due to mismatch of I-SID in I-TAG and I-SID
in backbone group MAC in the B-DA when port is non-promiscuous mode.ro PerfCounter64 (CM-COMMON-MIB) .1.3.6.1.4.1.2544.1.12.21.2.2.1.2 |
f3PBBConformance OBJECT IDENTIFIER .1.3.6.1.4.1.2544.1.12.21.3 |
f3PBBCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.2544.1.12.21.3.1 |
f3PBBGroups OBJECT IDENTIFIER .1.3.6.1.4.1.2544.1.12.21.3.2 |