F10-Z-SERIES-CHASSIS-MIB
AI MIB Summary
The F10-Z-SERIES-CHASSIS-MIB enables SNMP-based monitoring and management of physical chassis components, including power supplies, fans, temperature sensors, and system status indicators, specifically for Dell Networking OS Z-Series hardware.
Dell Networking OS Z-Series Chassis MIB.
Main OID:
f10ZSerChassisMib.1.3.6.1.4.1.6027.3.25
95
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
95 total| Object Name |
|---|
f10ZSerChassisMibDell Networking OS Z-Series Chassis MIB. MODULE-IDENTITY .1.3.6.1.4.1.6027.3.25 |
f10ZSerChassisObject OBJECT IDENTIFIER .1.3.6.1.4.1.6027.3.25.1 |
chObjects OBJECT IDENTIFIER .1.3.6.1.4.1.6027.3.25.1.1 |
chTypeThe type of chassis.ro F10ChassisType (FORCE10-TC) .1.3.6.1.4.1.6027.3.25.1.1.1 |
chSwVersionCurrent FTOS image version running in the system. The version string will be in following format major_ver.minor_ver(maintenance_ver.patch_ver)ro DisplayString .1.3.6.1.4.1.6027.3.25.1.1.2 |
chMacAddrA 6-octet MAC Address assigned to this Chassis.ro MacAddress (SNMPv2-TC) .1.3.6.1.4.1.6027.3.25.1.1.3 |
chSerialNumberThe chassis's serial number.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.1.4 |
chPartNumThe chassis manufacturer's part number.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.1.5 |
chProductRevThe chassis manufacturer's product revision.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.1.6 |
chVendorIdThe chassis manufacturer vendor's id.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.1.7 |
chMfgDateThe date the chassis was manufactured.ro F10MfgDate (FORCE10-TC) .1.3.6.1.4.1.6027.3.25.1.1.8 |
chCountryCodeThe chassis manufacturer's country code.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.1.9 |
chPiecePartIDThe chassis's piece part ID.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.1.10 |
chPPIDRevisionThe chassis's piece part ID revision.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.1.11 |
chServiceTagThe chassis's service tag.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.1.12 |
chExpressServiceCodeThe chassis's express service code.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.1.13 |
chNum10GigEtherPortsThe number of 10G Ethernet/802.3 interfaces in the chassis.ro Integer32 .1.3.6.1.4.1.6027.3.25.1.1.14 |
chNum40GigEtherPortsThe number of 40G Ethernet/802.3 interfaces in the chassis.ro Integer32 .1.3.6.1.4.1.6027.3.25.1.1.15 |
chNumLineCardsThe number of line cards currently supported in the chassis.ro Integer32 .1.3.6.1.4.1.6027.3.25.1.1.16 |
chNumFanTraysNumber of Fan trays in the chassis.ro Integer32 .1.3.6.1.4.1.6027.3.25.1.1.17 |
chNumPowerSuppliesNumber of Power supplies in the chassis.ro Integer32 .1.3.6.1.4.1.6027.3.25.1.1.18 |
chSysObjects OBJECT IDENTIFIER .1.3.6.1.4.1.6027.3.25.1.2 |
chSysProcessorTableA list of Processors resident in the chassis. The card table contains the Processor information of each Processor in the chassis. SEQUENCE OF ChSysProcessorEntry .1.3.6.1.4.1.6027.3.25.1.2.1 |
chSysProcessorEntryA list of Processor's entries containing information for Processors in the system. ChSysProcessorEntry .1.3.6.1.4.1.6027.3.25.1.2.1.1 |
chSysProcessorIndexA unique index for each Processor within the chassis. The valid entries are 1 to the value of number of processors. In Z9500, Index 1 - Control Processor Index 2 - Routing Processor Index 3 - LineCard Processor 0 Index 4 - LineCard Processor 1 Index 5 - LineCard Processor 2 Integer32 .1.3.6.1.4.1.6027.3.25.1.2.1.1.1 |
chSysProcessorTypeThe type of module running on the Processor.ro F10ProcessorModuleType (FORCE10-TC) .1.3.6.1.4.1.6027.3.25.1.2.1.1.2 |
chSysProcessorUpTimeThe SysUpTime for this Processor.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.6027.3.25.1.2.1.1.3 |
chSysProcessorMemSizeThe size of the RAM in MB.ro Integer32 .1.3.6.1.4.1.6027.3.25.1.2.1.1.4 |
chSysSwModuleTableA list of software version information in a processor. SEQUENCE OF ChSysSwModuleEntry .1.3.6.1.4.1.6027.3.25.1.2.2 |
chSysSwModuleEntryA software module entry containing version number information for a particular processor. ChSysSwModuleEntry .1.3.6.1.4.1.6027.3.25.1.2.2.1 |
chSysSwModuleRuntimeImgVersionCurrent FTOS image version running in the system. The version string will be in following format major_ver.minor_ver(maintenance_ver.patch_ver)ro DisplayString .1.3.6.1.4.1.6027.3.25.1.2.2.1.1 |
chSysSwModuleRuntimeImgDateThe release date of this software module.ro F10SwDate .1.3.6.1.4.1.6027.3.25.1.2.2.1.2 |
chSysSwModuleBootFlashImgVersionThis provides the Grub image version that is currently running in the processor.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.2.2.1.3 |
chSysSwModuleBootSelectorImgVersionThis provides the BIOS image version that is currently running in the processor.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.2.2.1.4 |
chSysSwModuleNextRebootImageThe image selection, when the chassis is rebooted. partitionA - Image stored in bootflash partition A: partitionB - Image stored in bootflash partition B: networkBoot - will be booted via network.ro Enumeration .1.3.6.1.4.1.6027.3.25.1.2.2.1.5 |
chSysSwModuleCurrentBootImageThe current image is booted from. partitionA - Image stored in bootflash partition A: partitionB - Image stored in bootflash partition B: networkBoot - Booted via network.ro Enumeration .1.3.6.1.4.1.6027.3.25.1.2.2.1.6 |
chSysSwModuleInPartitionAImgVersThis provides the FTOS system image version that is stored in partition A: and The version string has Major and Minor release numbers. It also denotes if the release is Maintenance, Technical, Patch, Beta, or Generally Availablero DisplayString .1.3.6.1.4.1.6027.3.25.1.2.2.1.7 |
chSysSwModuleInPartitionBImgVersThis provides the FTOS system image version that is stored in partition B: and The version string has Major and Minor release numbers. It also denotes if the release is Maintenance, Technical, Patch, Beta, or Generally Availablero DisplayString .1.3.6.1.4.1.6027.3.25.1.2.2.1.8 |
chSysCpuUtilTableA table listing the processor and memory utilization of of each CPU in the system. SEQUENCE OF ChSysCpuUtilEntry .1.3.6.1.4.1.6027.3.25.1.2.3 |
chSysCpuUtilEntryProcessor and Memory Utilization entry for a particular CPU. ChSysCpuUtilEntry .1.3.6.1.4.1.6027.3.25.1.2.3.1 |
chSysCpuUtil5SecCPU utilization in percentage for last 5 seconds.ro Gauge32 .1.3.6.1.4.1.6027.3.25.1.2.3.1.1 |
chSysCpuUtil1MinCPU utilization in percentage for last 1 minute.ro Gauge32 .1.3.6.1.4.1.6027.3.25.1.2.3.1.2 |
chSysCpuUtil5MinCPU utilization in percentage for last 5 minutes.ro Gauge32 .1.3.6.1.4.1.6027.3.25.1.2.3.1.3 |
chSysCpuUtilMemUsageTotal Memory usage in percentage.ro Gauge32 .1.3.6.1.4.1.6027.3.25.1.2.3.1.4 |
chSysCpuUtilFlashUsageTotal Flash usage in percentage.ro Gauge32 .1.3.6.1.4.1.6027.3.25.1.2.3.1.5 |
chSysLineCardTableA list of line cards resident in the chassis. This table contains the information on each linecard in the chassis. SEQUENCE OF ChSysLineCardEntry .1.3.6.1.4.1.6027.3.25.1.2.4 |
chSysLineCardEntryEntry for each line card in the chassis. ChSysLineCardEntry .1.3.6.1.4.1.6027.3.25.1.2.4.1 |
chSysLineCardIndexA unique index for each line card in the chassis. Integer32 .1.3.6.1.4.1.6027.3.25.1.2.4.1.1 |
chSysLineCardTypeLine card's type. In Z9500, there is 36 40G port line card and 48 40G port line card. z9500LC36 - 36 (40G) port LC z9500LC48 - 48 (40G) port LC.ro Enumeration .1.3.6.1.4.1.6027.3.25.1.2.4.1.2 |
chSysLineCardDescriptionA short description of the line card.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.2.4.1.3 |
chSysLineCardStatusThe current operational state of the line card.ro F10CardOperStatus (FORCE10-TC) .1.3.6.1.4.1.6027.3.25.1.2.4.1.4 |
chSysLineCardTempTemperature of the Line card.ro Integer32 UNITS "degrees Centigrade" .1.3.6.1.4.1.6027.3.25.1.2.4.1.5 |
chSysLineCardNum10GigEtherPortsThe number of 10G Ethernet/802.3 interfaces in the line card.ro Integer32 .1.3.6.1.4.1.6027.3.25.1.2.4.1.6 |
chSysLineCardNum40GigEtherPortsThe number of 40G Ethernet/802.3 interfaces in the line card.ro Integer32 .1.3.6.1.4.1.6027.3.25.1.2.4.1.7 |
chSysPortTableA list of ports in the Z-series chassis. SEQUENCE OF ChSysPortEntry .1.3.6.1.4.1.6027.3.25.1.2.5 |
chSysPortEntryA port entry containing objects for a particular port. ChSysPortEntry .1.3.6.1.4.1.6027.3.25.1.2.5.1 |
chSysPortIndexA unique index for each port within the Line Card. Line card 0 will have index from 1 to 144 Line card 1 will have index from 1 to 192 Line card 2 will have index from 1 to 192. Integer32 .1.3.6.1.4.1.6027.3.25.1.2.5.1.1 |
chSysPortTypeThe type of port in the unit.ro F10SSeriesPortType (FORCE10-TC) .1.3.6.1.4.1.6027.3.25.1.2.5.1.2 |
chSysPortAdminStatusThe admin status of the port. The port admin status is Up if the user has configured it to be up otherwise, the admin status is Down.ro Enumeration .1.3.6.1.4.1.6027.3.25.1.2.5.1.3 |
chSysPortOperStatusThe operational status provides further condition of the port. If the chSysPortAdminStatus is 'up', the valid state is 'ready' - the card is present and ready and the chSysPortAdminStatus status is 'up'. 'portDown' - the port is down or not enabled. 'portProblem' - port hardware problems. 'cardProblem' - not used. Same as cardDown. 'cardDown' - the card is downed. 'notPresent' - the card is not present.ro Enumeration .1.3.6.1.4.1.6027.3.25.1.2.5.1.4 |
chSysPortIfIndexThe index of ifIndex in the Interface Mib. This index can link to the ifEntry to get this interface/port informationro Integer32 .1.3.6.1.4.1.6027.3.25.1.2.5.1.5 |
chSysPortXfpRxPowerThe power signal strength (dB) received for 1G/10G/40G Ethernet/802.3 interface.ro F10HundredthdB UNITS "dB" .1.3.6.1.4.1.6027.3.25.1.2.5.1.6 |
chSysPortXfpRxTempThe temperature value received for the optics.ro Integer32 UNITS "degrees Centigrade" .1.3.6.1.4.1.6027.3.25.1.2.5.1.7 |
chSysPortXfpTxPowerThe power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface.ro F10HundredthdB UNITS "dB" .1.3.6.1.4.1.6027.3.25.1.2.5.1.8 |
chSysPowerSupplyTableA list of power supply resident in the Z-series chassis. SEQUENCE OF ChSysPowerSupplyEntry .1.3.6.1.4.1.6027.3.25.1.2.6 |
chSysPowerSupplyEntryA power supply entry containing objects for a particular power supply. ChSysPowerSupplyEntry .1.3.6.1.4.1.6027.3.25.1.2.6.1 |
chSysPowerSupplyIndexThe unique index of the power supply. Integer32 .1.3.6.1.4.1.6027.3.25.1.2.6.1.1 |
chSysPowerSupplyOperStatusThe status of the power supply.ro Enumeration .1.3.6.1.4.1.6027.3.25.1.2.6.1.2 |
chSysPowerSupplyTypeThe type of the power supply.ro Enumeration .1.3.6.1.4.1.6027.3.25.1.2.6.1.3 |
chSysPowerSupplyPiecePartIDThe power supply's piece part id.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.2.6.1.4 |
chSysPowerSupplyPPIDRevisionThe power supply's PPID revision.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.2.6.1.5 |
chSysPowerSupplyServiceTagThe power supply's service tag.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.2.6.1.6 |
chSysPowerSupplyExpressServiceCodeThe power supply's express service code.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.2.6.1.7 |
chSysPowerSupplyUsagePower usage of this Power Supply in Watts.ro Integer32 .1.3.6.1.4.1.6027.3.25.1.2.6.1.8 |
chSysFanTrayTableA list of fan tray resident in the Z-series chassis. SEQUENCE OF ChSysFanTrayEntry .1.3.6.1.4.1.6027.3.25.1.2.7 |
chSysFanTrayEntryA fan entry containing objects for a particular fan tray. ChSysFanTrayEntry .1.3.6.1.4.1.6027.3.25.1.2.7.1 |
chSysFanTrayIndexThe unique index of the fan tray. Integer32 .1.3.6.1.4.1.6027.3.25.1.2.7.1.1 |
chSysFanTrayOperStatusThe status of the fan tray.ro Enumeration .1.3.6.1.4.1.6027.3.25.1.2.7.1.2 |
chSysFanTrayPiecePartIDThe fan tray's piece part id.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.2.7.1.3 |
chSysFanTrayPPIDRevisionThe fan tray's PPID revision.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.2.7.1.4 |
chSysFanTrayServiceTagThe fan tray's service tag.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.2.7.1.5 |
chSysFanTrayExpressServiceCodeThe fan tray's express service code.ro DisplayString .1.3.6.1.4.1.6027.3.25.1.2.7.1.6 |
chSysSwCoresTableA table containing information about the software cores that have been generated as a result of system failures. SEQUENCE OF ChSysCoresEntry .1.3.6.1.4.1.6027.3.25.1.2.8 |
chSysCoresEntryA row in the software core table representing information about a core that has been generated. ChSysCoresEntry .1.3.6.1.4.1.6027.3.25.1.2.8.1 |
chSysCoresInstanceThe instance of the core for the process which which generated the core since the same process may have generated multiple cores.ro INTEGER .1.3.6.1.4.1.6027.3.25.1.2.8.1.1 |
chSysCoresFileNameThe name of the core file including the core.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6027.3.25.1.2.8.1.2 |
chSysCoresTimeCreatedThe time at which the core file was created.ro F10SwDate (FORCE10-TC) .1.3.6.1.4.1.6027.3.25.1.2.8.1.3 |
chSysCoresProcessorNameThe processor which generated the core.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6027.3.25.1.2.8.1.4 |
chSysCoresProcessThe name of the process which generated the core.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6027.3.25.1.2.8.1.5 |
f10ZSeriesChassisMibConformance OBJECT IDENTIFIER .1.3.6.1.4.1.6027.3.25.2 |
f10ZSeriesChassisMibCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.6027.3.25.2.1 |
f10ZSeriesChassisMibComplianceThe compliance statement for Dell Networking product which implement the Z-Series Chassis MIB. Unknown .1.3.6.1.4.1.6027.3.25.2.1.1 |
f10ZSeriesChassisMibGroups OBJECT IDENTIFIER .1.3.6.1.4.1.6027.3.25.2.2 |
f10ZSeriesComponentGroupA collection of objects providing the overall Z-series chassis information. Unknown .1.3.6.1.4.1.6027.3.25.2.2.1 |
f10ZSeriesSystemGroupA collection of objects providing the chassis system hardware information. Unknown .1.3.6.1.4.1.6027.3.25.2.2.2 |