Home/Catalog/F10-Z-SERIES-CHASSIS-MIB

F10-Z-SERIES-CHASSIS-MIB

AI MIB Summary

The F10-Z-SERIES-CHASSIS-MIB enables SNMP-based monitoring and management of physical chassis components, including power supplies, fans, temperature sensors, and system status indicators, specifically for Dell Networking OS Z-Series hardware.

Dell Networking OS Z-Series Chassis MIB.
Main OID:
f10ZSerChassisMib.1.3.6.1.4.1.6027.3.25
95
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

95 total
Object Name
f10ZSerChassisMibDell Networking OS Z-Series Chassis MIB.
MODULE-IDENTITY
.1.3.6.1.4.1.6027.3.25
f10ZSerChassisObject
OBJECT IDENTIFIER
.1.3.6.1.4.1.6027.3.25.1
chObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.6027.3.25.1.1
chTypeThe type of chassis.ro
F10ChassisType (FORCE10-TC)
.1.3.6.1.4.1.6027.3.25.1.1.1
chSwVersionCurrent FTOS image version running in the system. The version string will be in following format major_ver.minor_ver(maintenance_ver.patch_ver)ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.1.2
chMacAddrA 6-octet MAC Address assigned to this Chassis.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.6027.3.25.1.1.3
chSerialNumberThe chassis's serial number.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.1.4
chPartNumThe chassis manufacturer's part number.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.1.5
chProductRevThe chassis manufacturer's product revision.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.1.6
chVendorIdThe chassis manufacturer vendor's id.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.1.7
chMfgDateThe date the chassis was manufactured.ro
F10MfgDate (FORCE10-TC)
.1.3.6.1.4.1.6027.3.25.1.1.8
chCountryCodeThe chassis manufacturer's country code.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.1.9
chPiecePartIDThe chassis's piece part ID.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.1.10
chPPIDRevisionThe chassis's piece part ID revision.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.1.11
chServiceTagThe chassis's service tag.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.1.12
chExpressServiceCodeThe chassis's express service code.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.1.13
chNum10GigEtherPortsThe number of 10G Ethernet/802.3 interfaces in the chassis.ro
Integer32
.1.3.6.1.4.1.6027.3.25.1.1.14
chNum40GigEtherPortsThe number of 40G Ethernet/802.3 interfaces in the chassis.ro
Integer32
.1.3.6.1.4.1.6027.3.25.1.1.15
chNumLineCardsThe number of line cards currently supported in the chassis.ro
Integer32
.1.3.6.1.4.1.6027.3.25.1.1.16
chNumFanTraysNumber of Fan trays in the chassis.ro
Integer32
.1.3.6.1.4.1.6027.3.25.1.1.17
chNumPowerSuppliesNumber of Power supplies in the chassis.ro
Integer32
.1.3.6.1.4.1.6027.3.25.1.1.18
chSysObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.6027.3.25.1.2
chSysProcessorTableA list of Processors resident in the chassis. The card table contains the Processor information of each Processor in the chassis.
SEQUENCE OF ChSysProcessorEntry
.1.3.6.1.4.1.6027.3.25.1.2.1
chSysProcessorEntryA list of Processor's entries containing information for Processors in the system.
ChSysProcessorEntry
.1.3.6.1.4.1.6027.3.25.1.2.1.1
chSysProcessorIndexA unique index for each Processor within the chassis. The valid entries are 1 to the value of number of processors. In Z9500, Index 1 - Control Processor Index 2 - Routing Processor Index 3 - LineCard Processor 0 Index 4 - LineCard Processor 1 Index 5 - LineCard Processor 2
Integer32
.1.3.6.1.4.1.6027.3.25.1.2.1.1.1
chSysProcessorTypeThe type of module running on the Processor.ro
F10ProcessorModuleType (FORCE10-TC)
.1.3.6.1.4.1.6027.3.25.1.2.1.1.2
chSysProcessorUpTimeThe SysUpTime for this Processor.ro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.6027.3.25.1.2.1.1.3
chSysProcessorMemSizeThe size of the RAM in MB.ro
Integer32
.1.3.6.1.4.1.6027.3.25.1.2.1.1.4
chSysSwModuleTableA list of software version information in a processor.
SEQUENCE OF ChSysSwModuleEntry
.1.3.6.1.4.1.6027.3.25.1.2.2
chSysSwModuleEntryA software module entry containing version number information for a particular processor.
ChSysSwModuleEntry
.1.3.6.1.4.1.6027.3.25.1.2.2.1
chSysSwModuleRuntimeImgVersionCurrent FTOS image version running in the system. The version string will be in following format major_ver.minor_ver(maintenance_ver.patch_ver)ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.2.1.1
chSysSwModuleRuntimeImgDateThe release date of this software module.ro
F10SwDate
.1.3.6.1.4.1.6027.3.25.1.2.2.1.2
chSysSwModuleBootFlashImgVersionThis provides the Grub image version that is currently running in the processor.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.2.1.3
chSysSwModuleBootSelectorImgVersionThis provides the BIOS image version that is currently running in the processor.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.2.1.4
chSysSwModuleNextRebootImageThe image selection, when the chassis is rebooted. partitionA - Image stored in bootflash partition A: partitionB - Image stored in bootflash partition B: networkBoot - will be booted via network.ro
Enumeration
.1.3.6.1.4.1.6027.3.25.1.2.2.1.5
chSysSwModuleCurrentBootImageThe current image is booted from. partitionA - Image stored in bootflash partition A: partitionB - Image stored in bootflash partition B: networkBoot - Booted via network.ro
Enumeration
.1.3.6.1.4.1.6027.3.25.1.2.2.1.6
chSysSwModuleInPartitionAImgVersThis provides the FTOS system image version that is stored in partition A: and The version string has Major and Minor release numbers. It also denotes if the release is Maintenance, Technical, Patch, Beta, or Generally Availablero
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.2.1.7
chSysSwModuleInPartitionBImgVersThis provides the FTOS system image version that is stored in partition B: and The version string has Major and Minor release numbers. It also denotes if the release is Maintenance, Technical, Patch, Beta, or Generally Availablero
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.2.1.8
chSysCpuUtilTableA table listing the processor and memory utilization of of each CPU in the system.
SEQUENCE OF ChSysCpuUtilEntry
.1.3.6.1.4.1.6027.3.25.1.2.3
chSysCpuUtilEntryProcessor and Memory Utilization entry for a particular CPU.
ChSysCpuUtilEntry
.1.3.6.1.4.1.6027.3.25.1.2.3.1
chSysCpuUtil5SecCPU utilization in percentage for last 5 seconds.ro
Gauge32
.1.3.6.1.4.1.6027.3.25.1.2.3.1.1
chSysCpuUtil1MinCPU utilization in percentage for last 1 minute.ro
Gauge32
.1.3.6.1.4.1.6027.3.25.1.2.3.1.2
chSysCpuUtil5MinCPU utilization in percentage for last 5 minutes.ro
Gauge32
.1.3.6.1.4.1.6027.3.25.1.2.3.1.3
chSysCpuUtilMemUsageTotal Memory usage in percentage.ro
Gauge32
.1.3.6.1.4.1.6027.3.25.1.2.3.1.4
chSysCpuUtilFlashUsageTotal Flash usage in percentage.ro
Gauge32
.1.3.6.1.4.1.6027.3.25.1.2.3.1.5
chSysLineCardTableA list of line cards resident in the chassis. This table contains the information on each linecard in the chassis.
SEQUENCE OF ChSysLineCardEntry
.1.3.6.1.4.1.6027.3.25.1.2.4
chSysLineCardEntryEntry for each line card in the chassis.
ChSysLineCardEntry
.1.3.6.1.4.1.6027.3.25.1.2.4.1
chSysLineCardIndexA unique index for each line card in the chassis.
Integer32
.1.3.6.1.4.1.6027.3.25.1.2.4.1.1
chSysLineCardTypeLine card's type. In Z9500, there is 36 40G port line card and 48 40G port line card. z9500LC36 - 36 (40G) port LC z9500LC48 - 48 (40G) port LC.ro
Enumeration
.1.3.6.1.4.1.6027.3.25.1.2.4.1.2
chSysLineCardDescriptionA short description of the line card.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.4.1.3
chSysLineCardStatusThe current operational state of the line card.ro
F10CardOperStatus (FORCE10-TC)
.1.3.6.1.4.1.6027.3.25.1.2.4.1.4
chSysLineCardTempTemperature of the Line card.ro
Integer32 UNITS "degrees Centigrade"
.1.3.6.1.4.1.6027.3.25.1.2.4.1.5
chSysLineCardNum10GigEtherPortsThe number of 10G Ethernet/802.3 interfaces in the line card.ro
Integer32
.1.3.6.1.4.1.6027.3.25.1.2.4.1.6
chSysLineCardNum40GigEtherPortsThe number of 40G Ethernet/802.3 interfaces in the line card.ro
Integer32
.1.3.6.1.4.1.6027.3.25.1.2.4.1.7
chSysPortTableA list of ports in the Z-series chassis.
SEQUENCE OF ChSysPortEntry
.1.3.6.1.4.1.6027.3.25.1.2.5
chSysPortEntryA port entry containing objects for a particular port.
ChSysPortEntry
.1.3.6.1.4.1.6027.3.25.1.2.5.1
chSysPortIndexA unique index for each port within the Line Card. Line card 0 will have index from 1 to 144 Line card 1 will have index from 1 to 192 Line card 2 will have index from 1 to 192.
Integer32
.1.3.6.1.4.1.6027.3.25.1.2.5.1.1
chSysPortTypeThe type of port in the unit.ro
F10SSeriesPortType (FORCE10-TC)
.1.3.6.1.4.1.6027.3.25.1.2.5.1.2
chSysPortAdminStatusThe admin status of the port. The port admin status is Up if the user has configured it to be up otherwise, the admin status is Down.ro
Enumeration
.1.3.6.1.4.1.6027.3.25.1.2.5.1.3
chSysPortOperStatusThe operational status provides further condition of the port. If the chSysPortAdminStatus is 'up', the valid state is 'ready' - the card is present and ready and the chSysPortAdminStatus status is 'up'. 'portDown' - the port is down or not enabled. 'portProblem' - port hardware problems. 'cardProblem' - not used. Same as cardDown. 'cardDown' - the card is downed. 'notPresent' - the card is not present.ro
Enumeration
.1.3.6.1.4.1.6027.3.25.1.2.5.1.4
chSysPortIfIndexThe index of ifIndex in the Interface Mib. This index can link to the ifEntry to get this interface/port informationro
Integer32
.1.3.6.1.4.1.6027.3.25.1.2.5.1.5
chSysPortXfpRxPowerThe power signal strength (dB) received for 1G/10G/40G Ethernet/802.3 interface.ro
F10HundredthdB UNITS "dB"
.1.3.6.1.4.1.6027.3.25.1.2.5.1.6
chSysPortXfpRxTempThe temperature value received for the optics.ro
Integer32 UNITS "degrees Centigrade"
.1.3.6.1.4.1.6027.3.25.1.2.5.1.7
chSysPortXfpTxPowerThe power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface.ro
F10HundredthdB UNITS "dB"
.1.3.6.1.4.1.6027.3.25.1.2.5.1.8
chSysPowerSupplyTableA list of power supply resident in the Z-series chassis.
SEQUENCE OF ChSysPowerSupplyEntry
.1.3.6.1.4.1.6027.3.25.1.2.6
chSysPowerSupplyEntryA power supply entry containing objects for a particular power supply.
ChSysPowerSupplyEntry
.1.3.6.1.4.1.6027.3.25.1.2.6.1
chSysPowerSupplyIndexThe unique index of the power supply.
Integer32
.1.3.6.1.4.1.6027.3.25.1.2.6.1.1
chSysPowerSupplyOperStatusThe status of the power supply.ro
Enumeration
.1.3.6.1.4.1.6027.3.25.1.2.6.1.2
chSysPowerSupplyTypeThe type of the power supply.ro
Enumeration
.1.3.6.1.4.1.6027.3.25.1.2.6.1.3
chSysPowerSupplyPiecePartIDThe power supply's piece part id.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.6.1.4
chSysPowerSupplyPPIDRevisionThe power supply's PPID revision.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.6.1.5
chSysPowerSupplyServiceTagThe power supply's service tag.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.6.1.6
chSysPowerSupplyExpressServiceCodeThe power supply's express service code.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.6.1.7
chSysPowerSupplyUsagePower usage of this Power Supply in Watts.ro
Integer32
.1.3.6.1.4.1.6027.3.25.1.2.6.1.8
chSysFanTrayTableA list of fan tray resident in the Z-series chassis.
SEQUENCE OF ChSysFanTrayEntry
.1.3.6.1.4.1.6027.3.25.1.2.7
chSysFanTrayEntryA fan entry containing objects for a particular fan tray.
ChSysFanTrayEntry
.1.3.6.1.4.1.6027.3.25.1.2.7.1
chSysFanTrayIndexThe unique index of the fan tray.
Integer32
.1.3.6.1.4.1.6027.3.25.1.2.7.1.1
chSysFanTrayOperStatusThe status of the fan tray.ro
Enumeration
.1.3.6.1.4.1.6027.3.25.1.2.7.1.2
chSysFanTrayPiecePartIDThe fan tray's piece part id.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.7.1.3
chSysFanTrayPPIDRevisionThe fan tray's PPID revision.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.7.1.4
chSysFanTrayServiceTagThe fan tray's service tag.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.7.1.5
chSysFanTrayExpressServiceCodeThe fan tray's express service code.ro
DisplayString
.1.3.6.1.4.1.6027.3.25.1.2.7.1.6
chSysSwCoresTableA table containing information about the software cores that have been generated as a result of system failures.
SEQUENCE OF ChSysCoresEntry
.1.3.6.1.4.1.6027.3.25.1.2.8
chSysCoresEntryA row in the software core table representing information about a core that has been generated.
ChSysCoresEntry
.1.3.6.1.4.1.6027.3.25.1.2.8.1
chSysCoresInstanceThe instance of the core for the process which which generated the core since the same process may have generated multiple cores.ro
INTEGER
.1.3.6.1.4.1.6027.3.25.1.2.8.1.1
chSysCoresFileNameThe name of the core file including the core.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.6027.3.25.1.2.8.1.2
chSysCoresTimeCreatedThe time at which the core file was created.ro
F10SwDate (FORCE10-TC)
.1.3.6.1.4.1.6027.3.25.1.2.8.1.3
chSysCoresProcessorNameThe processor which generated the core.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.6027.3.25.1.2.8.1.4
chSysCoresProcessThe name of the process which generated the core.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.6027.3.25.1.2.8.1.5
f10ZSeriesChassisMibConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.6027.3.25.2
f10ZSeriesChassisMibCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.6027.3.25.2.1
f10ZSeriesChassisMibComplianceThe compliance statement for Dell Networking product which implement the Z-Series Chassis MIB.
Unknown
.1.3.6.1.4.1.6027.3.25.2.1.1
f10ZSeriesChassisMibGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.6027.3.25.2.2
f10ZSeriesComponentGroupA collection of objects providing the overall Z-series chassis information.
Unknown
.1.3.6.1.4.1.6027.3.25.2.2.1
f10ZSeriesSystemGroupA collection of objects providing the chassis system hardware information.
Unknown
.1.3.6.1.4.1.6027.3.25.2.2.2
F10-Z-SERIES-CHASSIS-MIB - SNMP MIB Reference | MIBs Explorer