ERI-DNX-LINK-TEST-MIB
The ERI Enterprise MIB Module for the DNX DSx1 links and HS ports.
Main OID:
eriDNXLinkTestMIB.1.3.6.1.4.1.644.3.8
72
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
72 total| Object Name |
|---|
diagnostics OBJECT IDENTIFIER .1.3.6.1.4.1.644.2.4.5 |
dsx1Test OBJECT IDENTIFIER .1.3.6.1.4.1.644.2.4.5.1 |
dsx1TestTableThis is the DS1/E1 Bit Error Test Statistics table which consists of an entry for each DS1/E1 port in the system. This table provides the total counters accumulated since the test has been on or since the last time the counts were cleared. The counters are calculated in accordance with the ITU-T G.821 Error performance events and parameters, August 1996. SEQUENCE OF DSx1TestEntry .1.3.6.1.4.1.644.2.4.5.1.1 |
dsx1TestEntryThe conceptual row of the DS1/E1 Bit Error Test Statistics table. A row in this table cannot be added or deleted but the counter time period can be reset to zero. DSx1TestEntry .1.3.6.1.4.1.644.2.4.5.1.1.1 |
dsx1TestLinkAddrThis number uniquely identifies an DS1/E1 link resource. This number will be used throughout the system to identify a unique link. The format is represented using an IP address syntax (4 byte string). Note that the maximum valid link number will vary depending on the specified carrier and framing options. For example, an octal T1/E1 device has 8 DS1 links but the DS3 has 28 DS1 links. The 1st byte is reserved for future Nest Number use The 2nd byte represents the Slot Number (1-11) The 3rd byte represents the Link Number (1-32) The 4th byte is reserved for future usero LinkPortAddress (ERI-DNX-SMC-MIB) .1.3.6.1.4.1.644.2.4.5.1.1.1.1 |
dsx1TestResrcIdUniquely identifies a link in the system. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.ro Integer32 .1.3.6.1.4.1.644.2.4.5.1.1.1.2 |
dsx1TestLinkStateDetermines the current line condition status of the link. In order to turn on a loop, the link must be configured In Service. ok (0) - In Sync yel (2) - Yellow Alarm ais (8) - Sending All Ones lof (32) - Loss of Frame los (64) - Loss of Signal red (2048) - Red Alarm cfa (4096) - Carrier Frame Alignment oos (65535) - Out of Service txSlip (2097152) - Transmit Slip rxSlip (4194304) - Receive Slip slip (6291456) - Transmit/Receive Slip sef (8388608) - Severely Errored Frames underTest(1073741824) - Running Bit Error Test (BERT) errors (2147483647) - Multiple Errors displays raw bit field valuero Enumeration .1.3.6.1.4.1.644.2.4.5.1.1.1.3 |
dsx1TestLinkLoopDetermines the status of the line loopback associated with this link. In order to turn on a loop, the link must be configured In Service. off (0) - indicates loopback is disabled local (1) - indicates local data is looped back to itself remote (2) - indicates data is looped back from remote to local not applicable to links configured for Clear mode line (3) - entire Frame is looped, framing is not regenerated payload (4) - only payload data is looped, framing is regenerated not applicable to links configured for Clear mode analog (5) - LIU is looped back remoteLine (7) - Remote Line (network) loop indicator, CANNOT be used in SET. smartjack (6) - special remote loop for 'smartjack' devices not applicable to links configured for Clear mode user-defined (8) - user defined loop applicable for T1 links. allLocal (12) - places all links are in local loop allLine (16) - places all links are in line loop loopUpReq (74) - Remote loop status indicator, CANNOT be used in SET. loopDwnReq (75) - Remote loop status indicator, CANNOT be used in SET.rw Enumeration .1.3.6.1.4.1.644.2.4.5.1.1.1.4 |
dsx1TestBackplnLoopDetermines whether or not the link has connection loopback via the Backplane. This affects a data connection which must already be in place prior to invoking this function.rw Enumeration .1.3.6.1.4.1.644.2.4.5.1.1.1.5 |
dsx1TestBertStateThis indicates the current BERT test running and can be used to start and stop a desired Test Period. In order to turn on a loop, the link must be configured In Service. As of release 14.2, all unframed bert patterns are no longer supported.rw Enumeration .1.3.6.1.4.1.644.2.4.5.1.1.1.6 |
dsx1TestDurationThis the total number of seconds the test data has been collected.ro Integer32 .1.3.6.1.4.1.644.2.4.5.1.1.1.7 |
dsx1TestBitErrsThis is the total number of bits in error since the Test has been running.ro Unsigned32 .1.3.6.1.4.1.644.2.4.5.1.1.1.8 |
dsx1TestESsThis is the total number of errored seconds that have occurred on the local link since the Test has been turned on. This Errored Second is defined as a one second period in which one or more bits are in error.ro Counter32 .1.3.6.1.4.1.644.2.4.5.1.1.1.9 |
dsx1TestRemoteESsThis is the total number of errored seconds that have occurred on the remote link since the Test has been turned on. This only applies to bi-directional Berts which are not supported on the Octal T1/E1 device. This Errored Second is defined as a one second period in which one or more bits are in error.ro Counter32 .1.3.6.1.4.1.644.2.4.5.1.1.1.10 |
dsx1TestErrFreeSecsThis is the total number of error free seconds since the Test has been running.ro Counter32 .1.3.6.1.4.1.644.2.4.5.1.1.1.11 |
dsx1TestSESsThis is the total number of severely errored seconds that have occurred since the Test has been running. This Severely Errored Second is defined as a one second period that contains bit errors equal to or greater than the Severe Error field.ro Counter32 .1.3.6.1.4.1.644.2.4.5.1.1.1.12 |
dsx1TestUASsThis is the number of Unavailable Seconds (UAS) that have occurred since the Test has been running. The UAS is a period of time consisting of 10 or more consecutive ESs.ro Counter32 .1.3.6.1.4.1.644.2.4.5.1.1.1.13 |
dsx1TestASsThis is the number of Available Seconds (AS) that have occurred since the Test has been running. The AS is the Test duration seconds minus the UAS.ro Counter32 .1.3.6.1.4.1.644.2.4.5.1.1.1.14 |
dsx1TestESNonUASsThis is the number of Error Seconds (ES) which are not part of the UAS that occurred since the Test has been running.ro Counter32 .1.3.6.1.4.1.644.2.4.5.1.1.1.15 |
dsx1TestSevereErrorThis is the number of bits in error in a given second that determine a severely errored second.rw Integer32 .1.3.6.1.4.1.644.2.4.5.1.1.1.16 |
dsx1TestBitSpeedThis is the current bit rate at which the link is configured for.ro Integer32 .1.3.6.1.4.1.644.2.4.5.1.1.1.17 |
dsx1TestCmdStatusThis is the command status for the DS1/E1 Link Test Row. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row DS1/E1 Action Commands used in SET Command (1..99) updateTest (1) Can be used optionally when activating loops and berts in order to get status code back in response clearErrors (14) Resets all error counters and bert test time to zero insertError (16) Inserts the current invalid bit pattern as indicated by the value of dsx1TestInsErrMode. Response States used in GET RESPONSE Command (100..199) update-successful (101) Test action has been successfully performed clear-successful (114) Error counts have been successfully cleared insert-successful (116) Errored bits have been successfully inserted DS1/E1 Test Error Codes used in GET RESPONSE Command (200..799) err-general-test-error (200) Unknown Test request error occurred. err-link-not-in-service (201) Requested action cannot be performed for OOS links err-invalid-loop-type (202) Unrecognized loop selection err-invalid-bert-type (203) Unrecognized bert selection err-link-in-clear-mode (204) Requested action cannot be performed for clear framed or clear unframed configured links err-test-in-progress (205) Requested action cannot be performed during bert err-field-cannot-be-set (206) Read-only field was included in SET request err-link-not-connected (207) Requested action cannot be performed without link connection err-invalid-command (208) Unrecognized Test Command requested err-invalid-user-defined-loop (209), The field specifying the Activate and Deactivate values is invalid. err-link-in-E1-mode (210), Must be in set in T1 mode for User Defined loops. err-link-not-in-test (211) Requested action cannot be performed without a bert err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too bigrw Enumeration .1.3.6.1.4.1.644.2.4.5.1.1.1.18 |
dsx1TestInsErrModeDetermines the status of the current Insert Error mode associated with this link. In order to insert an error, the dsx1TestCmdStatus must be sent in a SET PDU with a value of 'insertError'.rw Enumeration .1.3.6.1.4.1.644.2.4.5.1.1.1.19 |
dsx1TestUsrLoopUnframedThis specifies the type of framing to use during User Defined remote loops. no (0) - Loop data will be framed. yes (1) - Loop data will be unframed. This is the default.rw DecisionType (ERI-DNX-SMC-MIB) .1.3.6.1.4.1.644.2.4.5.1.1.1.20 |
dsx1TestUsrDefLoopThe user defined loop provides the length and value options for activating as well as deactivating the loop. The format is represented using an IP address syntax (4 byte string). The 1st byte signifies the Activate loop code bit length (4-7) The 2nd byte represents the Activate loop code value (0-255) The 3rd byte signifies the Deactivate loop code bit length (4-7) The 4th byte represents the Deactivate loop code value (0-255) The default Loop format is 5.8.6.36: Activate : 5 bits (length) 00001000 (decimal value = 8) Deactivate: 6 bits (length) 00100100 (decimal value = 36) Notes: - Loop code uses 4,5,6 or 7 high order bits of the code value. - Bit 7 is transmitted first. - Unframed code overwrites the framing bits.rw UserDefFormat .1.3.6.1.4.1.644.2.4.5.1.1.1.21 |
hsTest OBJECT IDENTIFIER .1.3.6.1.4.1.644.2.4.5.2 |
hsTestTableThis is the High Speed Bit Error Test Statistics table which consists of an entry for each High Speed port in the system. This table provides the total counters accumulated since the test has been running or since the last time the counts were cleared. SEQUENCE OF HSTestEntry .1.3.6.1.4.1.644.2.4.5.2.1 |
hsTestEntryThe conceptual row of the High Speed Bit Error Test Statistics table. A row in this table cannot be added or deleted but can be modified. HSTestEntry .1.3.6.1.4.1.644.2.4.5.2.1.1 |
hsTestLinkAddrThis number uniquely identifies an High Speed link resource. This number will be used throughout the system to identify a unique link. The format is represented using an IP address syntax (4 byte string). The 1st byte is reserved for future Nest Number use The 2nd byte represents the Slot Number (1-11) The 3rd byte represents the Link Number (1-8) The 4th byte is reserved for future usero LinkPortAddress (ERI-DNX-SMC-MIB) .1.3.6.1.4.1.644.2.4.5.2.1.1.1 |
hsTestResrcIdUniquely identifies a link in the system. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.ro Integer32 .1.3.6.1.4.1.644.2.4.5.2.1.1.2 |
hsTestLinkStateDetermines the current line condition status of the link. In order to turn on a loop, the link must be configured In Service with a Connection. ok (0) - In Sync rxFifo (2) - Receive FIFO Err txFifo (4) - Transmit FIFO Err fifo (6) - Transmit & Receive FIFO Errs clkEdgeErr (8) - Clock Edge Error carrierDrop(16) - Carrier Dropped on Link Failure noConn (255) - Connectionless Port oos (65535) - Out of Service errors (*) - Multiple Errors will display raw bit field valuero Enumeration .1.3.6.1.4.1.644.2.4.5.2.1.1.3 |
hsTestLocalLoopDetermines the status of the local loopback associated with this link. In order to turn on a loop, the link must be configured In Service with a Connection. off (0) - indicates loopback is disabled local (1) - indicates local data is looped back to itselfrw Enumeration .1.3.6.1.4.1.644.2.4.5.2.1.1.4 |
hsTestRemoteLoopDetermines the status of the remote side loopback associated with this link. In order to turn on a loop, the link must be configured In Service with a Connection. off (10) - indicates remote loopback is disabled remoteV54 (11) - indicates data is looped back from remote to local loopUpReq (74) - Remote loop status indicator, CANNOT be used in SET. loopDwnReq (75) - Remote loop status indicator, CANNOT be used in SET.rw Enumeration .1.3.6.1.4.1.644.2.4.5.2.1.1.5 |
hsTestBackplnLoopDetermines whether or not the link has connection loopback via the Backplane. This affects a data connection which must already be in place prior to invoking this function.rw Enumeration .1.3.6.1.4.1.644.2.4.5.2.1.1.6 |
hsTestBertStateThis indicates the current BERT test running and can be used to start and stop a desired Test Period. In order to turn on a loop, the link must be configured In Service.rw Enumeration .1.3.6.1.4.1.644.2.4.5.2.1.1.7 |
hsTestDurationThis the total number of seconds the test data has been collected.ro Integer32 .1.3.6.1.4.1.644.2.4.5.2.1.1.8 |
hsTestLocESsThis is the total number of errored seconds that have occurred on the local link since the Test has been turned on. This Errored Second is defined as a one second period in which one or more bits are in error.ro Counter32 .1.3.6.1.4.1.644.2.4.5.2.1.1.9 |
hsTestRemESsThis is the total number of errored seconds that have occurred on the remote side (backplane bus) since the Test has been turned on. This Errored Second is defined as a one second period in which one or more bits are in error.ro Counter32 .1.3.6.1.4.1.644.2.4.5.2.1.1.10 |
hsTestBitSpeedThis is the current bit rate at which the link is configured for.ro Integer32 .1.3.6.1.4.1.644.2.4.5.2.1.1.11 |
hsTestCmdStatusThis is the command status for the High Speed Test Row. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row High Speed Action Commands used in SET Command (1..99) updateTest (1) Can be used optionally when activating loops and berts in order to get status code back in response clearErrors (14) Resets all error counters and bert test time to zero insertError (16) Inserts an invalid bit pattern on both local and remote sides causing an Errored Second for both. Response States used in GET RESPONSE Command (100..199) update-successful (101) Test action has been successfully performed clear-successful (114) Error counts have been successfully cleared insert-successful (116) Errored bits have been successfully inserted High Speed Test Error Codes used in GET RESPONSE Command (200..799) err-general-test-error (200) Unknown Test request error occurred. err-link-not-in-service (201) Requested action cannot be performed for OOS ports err-invalid-loop-type (202) Unrecognized loop selection err-invalid-bert-type (203) Unrecognized bert selection err-link-not-connected (204) Requested action cannot be performed without connection err-test-in-progress (205) Requested action cannot be performed during bert err-field-cannot-be-set (206) Read-only field was included in SET request err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too bigrw Enumeration .1.3.6.1.4.1.644.2.4.5.2.1.1.12 |
hsTestLocEFSsThis is the total number of Local Error Free Seconds since the Test has been running.ro Counter32 .1.3.6.1.4.1.644.2.4.5.2.1.1.13 |
hsTestLocUASsThis is the number of Local Unavailable Seconds (UAS) that have occurred since the Test has been running. The UAS is a period of time consisting of 10 or more consecutive ESs.ro Counter32 .1.3.6.1.4.1.644.2.4.5.2.1.1.14 |
hsTestLocASsThis is the number of Local Available Seconds (AS) that have occurred since the Test has been running. The AS is the Test duration seconds minus the UAS.ro Counter32 .1.3.6.1.4.1.644.2.4.5.2.1.1.15 |
hsTestLocESNonUASsThis is the number of Local Error Seconds (ES) which are not part of the UAS that occurred since the Test has been running.ro Counter32 .1.3.6.1.4.1.644.2.4.5.2.1.1.16 |
hsTestRemEFSsThis is the total number of Remote Error Free Seconds since the Test has been running.ro Counter32 .1.3.6.1.4.1.644.2.4.5.2.1.1.17 |
hsTestRemUASsThis is the number of Remote Unavailable Seconds (UAS) that have occurred since the Test has been running. The UAS is a period of time consisting of 10 or more consecutive ESs.ro Counter32 .1.3.6.1.4.1.644.2.4.5.2.1.1.18 |
hsTestRemASsThis is the number of Remote Available Seconds (AS) that have occurred since the Test has been running. The AS is the Test duration seconds minus the UAS.ro Counter32 .1.3.6.1.4.1.644.2.4.5.2.1.1.19 |
hsTestRemESNonUASsThis is the number of Remote Error Seconds (ES) which are not part of the UAS that occurred since the Test has been running.ro Counter32 .1.3.6.1.4.1.644.2.4.5.2.1.1.20 |
dsx1Status OBJECT IDENTIFIER .1.3.6.1.4.1.644.2.4.5.3 |
dsx1StatusTableThis is the DS1/E1 Link Status Counters table which consists of an entry for each DS1/E1 port in the system. This table provides the total counters accumulated since the link has been up or since the last time the counts were cleared. SEQUENCE OF Dsx1StatusEntry .1.3.6.1.4.1.644.2.4.5.3.1 |
dsx1StatusEntryThe conceptual row of the DS1/E1 Link Status Counters table. A row in this table cannot be added or deleted but the counter time period can be reset to zero. Dsx1StatusEntry .1.3.6.1.4.1.644.2.4.5.3.1.1 |
dsx1StatusAddrThis number uniquely identifies an DS1/E1 link resource. This number will be used throughout the system to identify a unique link. The format is represented using an IP address syntax (4 byte string). Note that the maximum valid link number will vary depending on the specified carrier and framing options. For example, an octal T1/E1 device has 8 DS1 links but the DS3 has 28 DS1 links. The 1st byte is reserved for future Nest Number use The 2nd byte represents the Slot Number (1-11) The 3rd byte represents the Link Number (1-32) The 4th byte is reserved for future usero LinkPortAddress (ERI-DNX-SMC-MIB) .1.3.6.1.4.1.644.2.4.5.3.1.1.1 |
dsx1StatusResrcIdUniquely identifies a link in the system. This number is provided as key to allow the manager to map this entry to a corresponding Resource Table entry.ro Integer32 .1.3.6.1.4.1.644.2.4.5.3.1.1.2 |
dsx1StatusStateDetermines the current line condition status of the link. In order to turn on a loop, the link must be configured In Service. ok (0) - In Sync yel (2) - Yellow Alarm ais (8) - Sending All Ones lof (32) - Loss of Frame los (64) - Loss of Signal red (2048) - Red Alarm cfa (4096) - Carrier Frame Alignment oos (65535) - Out of Service txSlip (2097152) - Transmit Slip rxSlip (4194304) - Receive Slip slip (6291456) - Transmit/Receive Slip sef (8388608) - Severely Errored Frames underTest(1073741824) - Running Bit Error Test (BERT) errors (2147483647) - Multiple Errors displays raw bit field valuero Enumeration .1.3.6.1.4.1.644.2.4.5.3.1.1.3 |
dsx1StatusRedAlrmErrsThis is the number of seconds a Loss of Signal was declared.ro Counter32 .1.3.6.1.4.1.644.2.4.5.3.1.1.4 |
dsx1StatusRAIErrsThis is the number of seconds a Remote Alarm Indication was received. Sometimes referred to as a Yellow Alarm Indication.ro Counter32 .1.3.6.1.4.1.644.2.4.5.3.1.1.5 |
dsx1StatusMFRAIErrsThis is the number of seconds a Far End CAS Multi-Frame Alarm Indication was received. Sometimes referred to as a MF Yellow Alarm Indication.ro Counter32 .1.3.6.1.4.1.644.2.4.5.3.1.1.6 |
dsx1StatusLOSErrsThis is the number of seconds a Loss of Signal was declared.ro Counter32 .1.3.6.1.4.1.644.2.4.5.3.1.1.7 |
dsx1StatusAISErrsThis is the number of seconds a Alarm Indication Signal was declared.ro Counter32 .1.3.6.1.4.1.644.2.4.5.3.1.1.8 |
dsx1StatusOOFErrsThis is the number of seconds a Out Of Frame alignement error was declared.ro Counter32 .1.3.6.1.4.1.644.2.4.5.3.1.1.9 |
dsx1StatusSEFErrsThis is the number of seconds a Severely Errored Frame was declared.ro Counter32 .1.3.6.1.4.1.644.2.4.5.3.1.1.10 |
dsx1StatusTransSlipErrsThis is the number of seconds a controlled slip was detected on outgoing path.ro Counter32 .1.3.6.1.4.1.644.2.4.5.3.1.1.11 |
dsx1StatusRecvSlipErrsThis is the number of seconds a controlled slip was detected on incoming path.ro Counter32 .1.3.6.1.4.1.644.2.4.5.3.1.1.12 |
dsx1StatusCRCErrsThis is the total number of CRC-6 (T1) or CRC-4 (E1) errors detected.ro Counter32 .1.3.6.1.4.1.644.2.4.5.3.1.1.13 |
dsx1StatusBPVErrsThis is the total number of invalid Bipolar Violations or Code Violations detected.ro Counter32 .1.3.6.1.4.1.644.2.4.5.3.1.1.14 |
dsx1StatusFrameBitErrsThis is the total number of Frame Alignment Signal (FAS) framing words received incorrectly.ro Counter32 .1.3.6.1.4.1.644.2.4.5.3.1.1.15 |
dsx1StatusFarEndBlockErrsThis is the total number of Remote CRC errors reported.ro Counter32 .1.3.6.1.4.1.644.2.4.5.3.1.1.16 |
dsx1StatusTrunkConditionDetetermines if Trunk Conditioning state is 'On' or 'Off'.ro DataSwitch (ERI-DNX-SMC-MIB) .1.3.6.1.4.1.644.2.4.5.3.1.1.17 |
dsx1StatusInsErrModeDetermines the status of the current Insert Error mode associated with this link. In order to insert an error, the dsx1StatusCmdStatus must be sent in a SET PDU with a value of 'insertError'.rw Enumeration .1.3.6.1.4.1.644.2.4.5.3.1.1.18 |
dsx1StatusCmdStatusThis is the command status for the DS1/E1 Link Test Row. The value used in a SET will be replaced by a response value in the GET RESPONSE indicating success or failure. Default Response State used in GET RESPONSE Command ready-for-command (0) initial default status for a row DS1/E1 Action Commands used in SET Command (1..99) update (1) Can be used optionally when modifing insert mode in order to get status code back in response clearErrors (14) Resets all error counters to zero insertError (16) Inserts the current invalid bit pattern as indicated by the value of dsx1StatusInsErrMode. Response States used in GET RESPONSE Command (100..199) update-successful (101) Test action has been successfully performed clear-successful (114) Error counts have been successfully cleared insert-successful (116) Errored bits have been successfully inserted DS1/E1 Status Error Codes used in GET RESPONSE Command (200..799) err-general-status-error (200) Unknown link status table request error occurred. err-link-not-in-service (201) Requested action cannot be performed for OOS links err-link-in-clear-mode (204) Requested action cannot be performed for clear framed or clear unframed configured links err-test-in-progress (205) Requested action cannot be performed during bert err-field-cannot-be-set (206) Read-only field was included in SET request err-link-not-connected (207) Requested action cannot be performed without link connection err-invalid-command (208) Unrecognized Test Command requested err-link-not-in-test (211) Requested action cannot be performed without a bert err-snmp-parse-failed (500) Agent could not parse variable err-invalid-snmp-type (501) Variable ASN type does not match Agent defined type err-invalid-snmp-var-size (502) Variable size is too bigrw Enumeration .1.3.6.1.4.1.644.2.4.5.3.1.1.19 |
dsx1StatusRcvNationalBitsDisplays the E1 National S-bits being received on the link. This single byte field shows the values in Hex of the E1 NFA byte in odd frames as depicted below: sa8 sa7 sa6 sa5 sa4 reserved bits --- --- --- --- --- ------------- 1 1 1 1 1 0 0 0 = F8 Reserved bits are always zero.ro OneByteField (ERI-DNX-SMC-MIB) .1.3.6.1.4.1.644.2.4.5.3.1.1.20 |
eriDNXLinkTestMIBThe ERI Enterprise MIB Module for the DNX DSx1 links and HS ports. MODULE-IDENTITY .1.3.6.1.4.1.644.3.8 |