Home/Catalog/ENDACE-SYSTEM-MIB

ENDACE-SYSTEM-MIB

AI MIB Summary

The ENDACE-SYSTEM-MIB provides SNMP access to monitor Endace hardware and software resources, specifically tracking CPU utilization, process management status, mounted volume states, and the configuration of the Central Management Controller (CMC). This module enables the observation of system-level health indicators and hardware-dependent components, such as RAID arrays, subject to the specific product configuration and available physical resources.

General system objects that are common to all Endace products, covering CPU usage, process manager, mounted volumes and CMC. The availability of some objects is limited by configuration or existent hardware, such as CMC configuration or RAID array.
Main OID:
shogunSystemMIB.1.3.6.1.4.1.18418.1
160
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

160 total
Object Name
shogunSystemMIBGeneral system objects that are common to all Endace products, covering CPU usage, process manager, mounted volumes and CMC. The availability of some objects is limited by configuration or existent hardware, such as CMC configuration or RAID array.
MODULE-IDENTITY
.1.3.6.1.4.1.18418.1
variables
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.1
systemAppliance
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.1.1
systemVersionSystem software version stringro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.1
cpu
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.1.1.2
cpuLoad1One-minute CPU load in hundredthsro
Unsigned32
.1.3.6.1.4.1.18418.1.1.1.2.1
cpuLoad5Five-minute CPU load in hundredthsro
Unsigned32
.1.3.6.1.4.1.18418.1.1.1.2.2
cpuLoad15Fifteen-minute CPU load in hundredthsro
Unsigned32
.1.3.6.1.4.1.18418.1.1.1.2.3
cpuUtil1Percentage CPU utilization, aggregated across all CPUs, rolling average over the past minutero
Unsigned32
.1.3.6.1.4.1.18418.1.1.1.2.4
cpuTableList of CPUs
SEQUENCE OF CpuEntry
.1.3.6.1.4.1.18418.1.1.1.2.5
cpuEntryEntry for one CPU
CpuEntry
.1.3.6.1.4.1.18418.1.1.1.2.5.1
cpuIndexIndex of CPU, starting from 0ro
Unsigned32
.1.3.6.1.4.1.18418.1.1.1.2.5.1.1
idleTimeTime in milliseconds CPU has spent idlero
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.18418.1.1.1.2.5.1.2
systemTimeTime in milliseconds CPU has spent busy with system tasksro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.18418.1.1.1.2.5.1.3
userTimeTime in milliseconds CPU has spent busy with user tasksro
TimeTicks (SNMPv2-SMI)
.1.3.6.1.4.1.18418.1.1.1.2.5.1.4
utilPct1MinPercentage CPU utilization over the past minutero
Unsigned32
.1.3.6.1.4.1.18418.1.1.1.2.5.1.5
procmgr
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.1.1.3
procTableList of processes managed or monitored by Process Manager
SEQUENCE OF ProcEntry
.1.3.6.1.4.1.18418.1.1.1.3.1
procEntryEntry for one process
ProcEntry
.1.3.6.1.4.1.18418.1.1.1.3.1.1
procIndexSynthetic numeric unique ID of processro
Unsigned32
.1.3.6.1.4.1.18418.1.1.1.3.1.1.1
procNameUnique name of processro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.3.1.1.2
procStatusCurrent state of processro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.3.1.1.3
procNumFailuresNumber of times process has crashed or exited unexpectedlyro
Unsigned32
.1.3.6.1.4.1.18418.1.1.1.3.1.1.4
mountmgr
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.1.1.5
mountTableList of all mounted partitions
SEQUENCE OF MountEntry
.1.3.6.1.4.1.18418.1.1.1.5.1
mountEntryEntry for one mounted partition
MountEntry
.1.3.6.1.4.1.18418.1.1.1.5.1.1
mountIndexA unique value, greater then or equal to one, for each mount in the managed system. It is recommended that values are assigned contiguously starting from 1.ro
Unsigned32
.1.3.6.1.4.1.18418.1.1.1.5.1.1.1
mountBytesAvailThe number of available bytes on the mount.ro
Counter64
.1.3.6.1.4.1.18418.1.1.1.5.1.1.2
mountBytesFreeThe number of bytes free on the mount.ro
Counter64
.1.3.6.1.4.1.18418.1.1.1.5.1.1.3
mountBytesPercentFreeThe number of bytes free as a percent of the total amount for the mount.ro
Unsigned32
.1.3.6.1.4.1.18418.1.1.1.5.1.1.4
mountBytesTotalThe total number of bytes on the mount.ro
Counter64
.1.3.6.1.4.1.18418.1.1.1.5.1.1.5
mountBytesUsedThe number of bytes used on the mount.ro
Counter64
.1.3.6.1.4.1.18418.1.1.1.5.1.1.6
mountPointThe mount point for the device.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.5.1.1.7
mountDeviceNameThe device name of the mount.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.5.1.1.8
mountInodesFreeThe number of inodes free on the mount.ro
Counter64
.1.3.6.1.4.1.18418.1.1.1.5.1.1.9
mountInodesPercentFreeThe number of inodes free on the mount as a percentage of the total.ro
Unsigned32
.1.3.6.1.4.1.18418.1.1.1.5.1.1.10
mountInodesTotalThe total number of inodes on the mount.ro
Counter64
.1.3.6.1.4.1.18418.1.1.1.5.1.1.11
mountInodesUsedThe total number of inodes used on the mount.ro
Counter64
.1.3.6.1.4.1.18418.1.1.1.5.1.1.12
sessions
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.1.1.6
sessionTableList of active user-sessions
SEQUENCE OF SessionEntry
.1.3.6.1.4.1.18418.1.1.1.6.1
sessionEntryEntry for one active session
SessionEntry
.1.3.6.1.4.1.18418.1.1.1.6.1.1
sessionIdSession IDro
Unsigned32
.1.3.6.1.4.1.18418.1.1.1.6.1.1.1
usernameUsernamero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.6.1.1.2
usernameLocalLocal usernamero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.6.1.1.3
remoteAddrRemote IP addressro
IpAddress
.1.3.6.1.4.1.18418.1.1.1.6.1.1.4
remoteHostnameRemote hostnamero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.6.1.1.5
clientDescrClient descriptionro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.6.1.1.6
raid
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.1.1.7
raidDrvTableTable for RAID drives.
SEQUENCE OF RaidDrvEntry
.1.3.6.1.4.1.18418.1.1.1.7.1
raidDrvEntryRow of RAID drive table.
RaidDrvEntry
.1.3.6.1.4.1.18418.1.1.1.7.1.1
raidDrvIndexIndex for RAID drive table
INTEGER
.1.3.6.1.4.1.18418.1.1.1.7.1.1.1
raidDrvIdNumerical drive ID as used in the device name.ro
INTEGER
.1.3.6.1.4.1.18418.1.1.1.7.1.1.2
raidDrvTypeType of drive (SATA, SAS, SSD, ect.).ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.7.1.1.3
raidDrvSerialNoSerial number of drive.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.7.1.1.4
raidDrvWearoutWear out level of SSD device.ro
Integer32 (-1..100)
.1.3.6.1.4.1.18418.1.1.1.7.1.1.5
raidDrvLbaWrittenNumber of logical blocks written to device.ro
Counter64
.1.3.6.1.4.1.18418.1.1.1.7.1.1.6
raidDrvReallocReallocated sectors.ro
Integer32
.1.3.6.1.4.1.18418.1.1.1.7.1.1.7
raidDrvPendingCount of currently pending sectors.ro
Integer32
.1.3.6.1.4.1.18418.1.1.1.7.1.1.8
raidDrvUncorrErrorsCount of uncorrectable errors.ro
Integer32
.1.3.6.1.4.1.18418.1.1.1.7.1.1.9
raidDrvDefectNumber of defect blocks.ro
Integer32
.1.3.6.1.4.1.18418.1.1.1.7.1.1.10
raidDrvFdeCapableShows, whether the drive supports Full Disc Encryption: Capable: drive support Full Disk Encryption. Not Capable: drive doesn't support Full Disk Encryption.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.7.1.1.11
raidDrvSecurityShows security status of RAID drive: Secured: drive is encrypted. Unsecured: drive is not encrypted.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.7.1.1.12
raidDrvLockingShows locking status of RAID drive: locked : keys don't match unlocked : keys match, disk is accessible.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.7.1.1.13
raidBbuTableTable for Battery Backup Units.
SEQUENCE OF RaidBbuEntry
.1.3.6.1.4.1.18418.1.1.1.7.2
raidBbuEntryRow of BBU table.
RaidBbuEntry
.1.3.6.1.4.1.18418.1.1.1.7.2.1
raidBbuIndexIndex for BBU table.
INTEGER
.1.3.6.1.4.1.18418.1.1.1.7.2.1.1
raidBbuIdNumerical BBU ID.ro
INTEGER
.1.3.6.1.4.1.18418.1.1.1.7.2.1.2
raidBbuStatusEnumerated status of Battery Backup Unit.ro
Enumeration
.1.3.6.1.4.1.18418.1.1.1.7.2.1.3
raidBbuStatusInfoString with status message.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.7.2.1.4
dataPartList of rotation files and VM images.
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.1.1.8
dataPartTableTable of files on /data partition to break down usage.
SEQUENCE OF DataPartEntry
.1.3.6.1.4.1.18418.1.1.1.8.1
dataPartEntryRow of table of files on /data partition to break down usage.
DataPartEntry
.1.3.6.1.4.1.18418.1.1.1.8.1.1
dataPartIndexIndex for files table on /data.
INTEGER
.1.3.6.1.4.1.18418.1.1.1.8.1.1.1
dataPartTypeType of file.ro
Enumeration
.1.3.6.1.4.1.18418.1.1.1.8.1.1.2
dataPartNameFilename.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.8.1.1.3
dataPartSizeSize of data files in MB.ro
Gauge32 UNITS "MB"
.1.3.6.1.4.1.18418.1.1.1.8.1.1.4
dataPartSizeCapMaximum size of data files in MB.ro
Gauge32 UNITS "MB"
.1.3.6.1.4.1.18418.1.1.1.8.1.1.5
dataPartMetadataSizeSize of disk area holding the meta data in MB.ro
Gauge32 UNITS "MB"
.1.3.6.1.4.1.18418.1.1.1.8.1.1.6
dataPartMetadataSizeCapMaximum size of disk area holding the meta data in MB.ro
Gauge32 UNITS "MB"
.1.3.6.1.4.1.18418.1.1.1.8.1.1.7
systemServiceLevelShows the current service level of the system: nomal: regular operational state maintenance: system ios in maintenance mode and supports only a minimum of functionality. See User Guide for details.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.9
systemSerialSystem Serial Number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.10
systemModelSystem Model.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.1.11
cmc
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.1.2
applTableList of appliances managed by the CMC
SEQUENCE OF ApplEntry
.1.3.6.1.4.1.18418.1.1.2.1
applEntryEntry for one managed appliance
ApplEntry
.1.3.6.1.4.1.18418.1.1.2.1.1
applIndexSynthetic numeric unique ID of appliancero
Unsigned32
.1.3.6.1.4.1.18418.1.1.2.1.1.1
applNameTextual ID/name of appliancero
OCTET STRING
.1.3.6.1.4.1.18418.1.1.2.1.1.2
applConnectedIs CMC connected to this appliance (2=no, 1=yes)ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.2.1.1.3
applOKDid this appliance pass its most recent status check (2=no, 1=yes)ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.2.1.1.4
raidStatusCodeNon-zero status code returned by the RAID controller when in error.ro
RaidStatusCode
.1.3.6.1.4.1.18418.1.1.3
sysDiskRaidStatusCodeNon-zero status code returned by the system disk RAID controller when in error.ro
RaidStatusCode
.1.3.6.1.4.1.18418.1.1.4
raidDiskStatusCodeNon-zero status code returned by the system when in error.ro
Enumeration
.1.3.6.1.4.1.18418.1.1.5
raidDiskSecurityModeRAID security status Information.ro
Enumeration
.1.3.6.1.4.1.18418.1.1.6
fipsInformation about FIPS
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.1.7
fipsStatusFIPS status: disabled: FIPS mode is disabled, enabled: FIPS mode is enabled and the power-on self-test passed, error: FIPS mode is enabled but the power-on self-test failed.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.1.1.7.1
systemTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.3
notificationPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.3.0
procCrashA procCrash trap signifies that a process managed by Process Manager has crashed and left a core file. The variable sent with the notification indicates which process crashed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.1
procExitA procExit trap signifies that a process managed by Process Manager has exited unexpectedly, but not left a core file. The variable sent with the notification indicates which process exited.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.2
procNormalA procNormal trap signifies that a process managed by the process manager (PM) was restarted by the PM because it failed a liveness test or crashed unexpectedly and has now been restarted. If the problem with the process is reoccurring then either a procCrash, procExit or liveness test trap will be resent.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.3
cpuUtilHighThe average CPU utilization in the past minute has gone above the acceptable threshold.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.4
cpuUtilNormalThe average CPU utilization in the past minute has gone below the acceptable threshold again.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.5
pagingActivityHighThe system has been paging excessively (thrashing)obsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.6
pagingActivityNormalThe system was previously paging excessively (thrashing) but is now paging within acceptable limits.obsolete
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.7
smartErrorSMART has sent an event about a possible disk error
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.8
unexpectedShutdownThe system has shut down unexpectedly
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.9
diskSpaceLowDisk space on the system is low
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.10
diskSpaceNormalDisk space on the system was low but now has returned to a normal operating level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.11
procLivenessFailureProcess Manager has detected that a process has hung, and will now perform its restart action
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.12
cmcStatusFailureOne or more status criteria on a CMC-managed appliance have failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.13
cmcStatusNormalA CMC-managed appliance had passes its status check, where it previously failed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.14
memUtilizationHighMemory utilization on the system is high
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.15
netUtilizationHighNetwork utilization on the system is high
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.16
diskIOHighDisk I/O on the system is high
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.17
cmcVersionMismatchThe system software version on a CMC managed appliance does not match the server version
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.18
raidStatusOkThe RAID array is in its optimal state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.19
raidStatusNotOkThe RAID array is in a suboptimal state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.20
userLoginA user has logged into the system
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.21
userLogoutA user has logged out of the system
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.22
sysDiskRaidStatusOkThe system disk RAID array is in its optimal state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.23
sysDiskRaidStatusNotOkThe system disk RAID array is in a suboptimal state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.24
raidDiskStatusOkOverall disk health is OK.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.25
raidDiskStatusNotOkOverall disk health is not OK. (details in raidDiskStatusCode)
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.26
raidDrvWearWarningWearout level of SSD exceeded warning level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.27
raidDrvWearCriticalWearout level of SSD exceeded critical level.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.28
raidBbuOkBattery Backup Unit status is back to normal.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.29
raidBbuWarningBattery Backup Unit status went into warning state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.30
raidBbuErrorBattery Backup Unit status went into alarm state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.31
raidDiskWarningDisk health is in a warning state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.32
raidDiskErrorDisk health is in an error state.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.33
cmcConnectionDownConnection to a CMC-managed appliance is down.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.34
cmcConnectionUpConnection to a CMC-managed appliance is up.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.35
ipfixEngineStartThe IPFIX/Netflow generator engine was started.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.40
ipfixEngineStopThe IPFIX/Netflow generator engine was stopped regularly. This usually happens during reconfigurations.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.41
diskIONormalDisk I/O on system is back to normal
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.42
memUtilizationNormalMemory utilization on the system is back to normal
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.43
netUtilizationNormalNetwork utilization on the system is back to normal
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.44
systemServiceLevelChangedThis notification is triggered when the system service level changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.45
fipsStatusChangedIndicates a change of the FIPS status OID 'fipsStatus'.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.46
testTrapTest trap, can be triggered by CLI command 'snmp-server notify send-test'.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.1.3.0.100
systemConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.4
systemGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.4.1
systemInformationGroupA collection of objects providing information applicable to the overall system.
Unknown
.1.3.6.1.4.1.18418.1.4.1.1
cmcInformationGroupA collection of objects providing information applicable to CMC enabled appliances.
Unknown
.1.3.6.1.4.1.18418.1.4.1.2
systemNotificationsGroupA collection of objects providing notifications related to overall system health.
Unknown
.1.3.6.1.4.1.18418.1.4.1.3
cmcNotificationsGroupA collection of objects providing information related to CMC related notifications.
Unknown
.1.3.6.1.4.1.18418.1.4.1.4
systemInformationGroup2A collection of objects providing additional information applicable to overall system.
Unknown
.1.3.6.1.4.1.18418.1.4.1.5
systemDiskRaidInformationGroupManaged objects associated to the system disk RAID array. This group applies only to systems that use a RAID array as system disk.
Unknown
.1.3.6.1.4.1.18418.1.4.1.6
systemDiskRaidNotificationsGroupNotifications associated to the system disk RAID array. This group applies only to systems that use a RAID array as system disk.
Unknown
.1.3.6.1.4.1.18418.1.4.1.7
ssdRaidInformationGroupThis groups contains all objects being valid, when the sytem deploys an SSD RAID array.
Unknown
.1.3.6.1.4.1.18418.1.4.1.8
ssdRaidNotificationsGroupThis groups contains all notifications being used, when the sytem deploys an SSD RAID array.
Unknown
.1.3.6.1.4.1.18418.1.4.1.9
bbuInformationGroupThis groups contains all objects being valid, when the sytem deploys Battery Backup Unit
Unknown
.1.3.6.1.4.1.18418.1.4.1.10
bbuNotificationsGroupThis groups contains all notifications being used, when the sytem deploys a Battery Backup Unit.
Unknown
.1.3.6.1.4.1.18418.1.4.1.11
dataPartGroupAll objects that describe files on the /data partition.
Unknown
.1.3.6.1.4.1.18418.1.4.1.12
ipfixNotifyGroupThese notification will only emerge from a IPFIX/Netflow generator appliance.
Unknown
.1.3.6.1.4.1.18418.1.4.1.13
obsoleteNotificationsThis group contains obsolete notifications, because even if unused according to SMIv2 practices all notifications have to be in at least one group.obsolete
Unknown
.1.3.6.1.4.1.18418.1.4.1.14
fipsInformationGroupConformance group for all FIPS related OIDs.
Unknown
.1.3.6.1.4.1.18418.1.4.1.15
fipsNotificationGroupGroup for all FIPS related notifications.
Unknown
.1.3.6.1.4.1.18418.1.4.1.16
systemCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.1.4.2
systemCompliance1The compliance statement for managed Endace network entities.
Unknown
.1.3.6.1.4.1.18418.1.4.2.1
ENDACE-SYSTEM-MIB - SNMP MIB Reference | MIBs Explorer