The ENDACE-INVMGR-MIB provides SNMP access to monitor and manage the Investigation Manager Appliance, specifically exposing metrics related to network traffic capture sources, packet buffer utilization, and system health status for forensic data collection operations.

MIB for Investigation Manager Appliance Sources.
Main OID:
invmgrMIB.1.3.6.1.4.1.18418.15
21
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

21 total
Object Name
invmgrMIBMIB for Investigation Manager Appliance Sources.
MODULE-IDENTITY
.1.3.6.1.4.1.18418.15
invmgrNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.15.0
invmgrConnectionChangedThe Investigation source Endace Appliance connection has changed.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.15.0.1
invmgrObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.15.1
invmgrApplStateTableList of Endace Appliances used as Investigation Sources by the Investigation Manager.
SEQUENCE OF InvmgrApplStateEntry
.1.3.6.1.4.1.18418.15.1.1
invmgrApplStateEntryEntry for one Investigation Source Endace Appliance.
InvmgrApplStateEntry
.1.3.6.1.4.1.18418.15.1.1.1
invmgrApplStateIndexSynthetic numeric unique ID of an Endace Appliance.
INTEGER
.1.3.6.1.4.1.18418.15.1.1.1.1
invmgrApplStateNameTextual ID/name of appliance.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.15.1.1.1.2
invmgrApplStateConnectedIs Investigation Manager connected to this Endace Appliance? (2=no,1=yes)ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18418.15.1.1.1.3
invmgrApplStateOKDid this Endace Appliance pass its most recent status check? (2=no,1=yes)ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18418.15.1.1.1.4
invmgrApplConfigTableList of configuration entries of Investigation Manager appliances.
SEQUENCE OF InvmgrApplConfigEntry
.1.3.6.1.4.1.18418.15.1.2
invmgrApplConfigEntryConfiguration for one Investigation Manager Source Endace Appliance.
InvmgrApplConfigEntry
.1.3.6.1.4.1.18418.15.1.2.1
invmgrApplConfigIndexSynthetic numeric unique ID of Appliance.
INTEGER
.1.3.6.1.4.1.18418.15.1.2.1.1
invmgrApplConfigNameTextual ID/name of appliance.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.18418.15.1.2.1.2
invmgrApplConfigEnabledIs this Endace Appliance enabled in the Investigation Manager? (1=yes, 2=no)ro
TruthValue (SNMPv2-TC)
.1.3.6.1.4.1.18418.15.1.2.1.3
invmgrConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.15.2
invmgrCompliances
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.15.2.1
invmgrMandatoryMandatory groups for Investigation Manager Appliances.
Unknown
.1.3.6.1.4.1.18418.15.2.1.1
invmgrGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.15.2.2
invmgrBasicObjectsInvestigation Manager basic objects.
Unknown
.1.3.6.1.4.1.18418.15.2.2.1
invmgrBasicEventsInvestigation Manager basic events.
Unknown
.1.3.6.1.4.1.18418.15.2.2.2