ENDACE-EDA-MIB
AI MIB Summary
The ENDACE-EDA-MIB module facilitates SNMP-based event notification and status monitoring for Endace's integrated packet capture and analysis appliances, formerly marketed as Shogun. It enables the tracking of application-specific operational states and alert conditions within the Endace hardware ecosystem.
MIB for event notification from integrated Endace's applications, formerly known as 'Shogun'.
Main OID:
shogunEventMIB.1.3.6.1.4.1.18418.9
19
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
19 total| Object Name |
|---|
shogunEventMIBMIB for event notification from integrated Endace's applications, formerly known as 'Shogun'. MODULE-IDENTITY .1.3.6.1.4.1.18418.9 |
shogunVariables OBJECT IDENTIFIER .1.3.6.1.4.1.18418.9.1 |
agentIdUnique ID of the Agent that generated the eventro OCTET STRING .1.3.6.1.4.1.18418.9.1.1 |
eventIdUnique ID of the Event that the Agent generated.ro OCTET STRING .1.3.6.1.4.1.18418.9.1.2 |
eventDescrTextual description of the Event that the Agent generated.ro OCTET STRING .1.3.6.1.4.1.18418.9.1.3 |
alarmNameUnique Name of the Rule that generated the alarmro OCTET STRING .1.3.6.1.4.1.18418.9.1.4 |
alarmDescrDescription of the Rule that generated the alarmro OCTET STRING .1.3.6.1.4.1.18418.9.1.5 |
alarmTriggerThe trigger that generated the alarmro Counter64 .1.3.6.1.4.1.18418.9.1.6 |
alarmCriteriaThe criteria that generated the alarmro Unsigned32 .1.3.6.1.4.1.18418.9.1.7 |
alarmTypeThe type of the alarmrw Unsigned32 .1.3.6.1.4.1.18418.9.1.8 |
alarmSeverityThe severity of the alarmro Unsigned32 .1.3.6.1.4.1.18418.9.1.9 |
shogunEventTraps OBJECT IDENTIFIER .1.3.6.1.4.1.18418.9.3 |
shogunNotificationPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.18418.9.3.0 |
eventNotificationAn eventNotification trap indicates that an application integrated with Shogun has generated an Event that requires the attention of the system administrator. NOTIFICATION-TYPE .1.3.6.1.4.1.18418.9.3.0.1 |
alarmRaisedNotificationAn alarmRaisedNotification trap indicates that an alarm that requires the attention of the system administrator was raised. NOTIFICATION-TYPE .1.3.6.1.4.1.18418.9.3.0.2 |
alarmClearedNotificationAn alarmClearedNotification trap indicates that an alarm that was raised previously was cleared. NOTIFICATION-TYPE .1.3.6.1.4.1.18418.9.3.0.3 |
shogunConfContainer for Endace appliances MIB conformance groups. OBJECT IDENTIFIER .1.3.6.1.4.1.18418.9.4 |
shogunNotifyGroupGeneral alarm-specific notifications shared among Endace applications. Unknown .1.3.6.1.4.1.18418.9.4.1 |
shogunObjectGroupGeneral alarm-specific managed objects shared among Endace applications. Unknown .1.3.6.1.4.1.18418.9.4.2 |