Home/Catalog/ENDACE-EDA-MIB

ENDACE-EDA-MIB

AI MIB Summary

The ENDACE-EDA-MIB module facilitates SNMP-based event notification and status monitoring for Endace's integrated packet capture and analysis appliances, formerly marketed as Shogun. It enables the tracking of application-specific operational states and alert conditions within the Endace hardware ecosystem.

MIB for event notification from integrated Endace's applications, formerly known as 'Shogun'.
Main OID:
shogunEventMIB.1.3.6.1.4.1.18418.9
19
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

19 total
Object Name
shogunEventMIBMIB for event notification from integrated Endace's applications, formerly known as 'Shogun'.
MODULE-IDENTITY
.1.3.6.1.4.1.18418.9
shogunVariables
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.9.1
agentIdUnique ID of the Agent that generated the eventro
OCTET STRING
.1.3.6.1.4.1.18418.9.1.1
eventIdUnique ID of the Event that the Agent generated.ro
OCTET STRING
.1.3.6.1.4.1.18418.9.1.2
eventDescrTextual description of the Event that the Agent generated.ro
OCTET STRING
.1.3.6.1.4.1.18418.9.1.3
alarmNameUnique Name of the Rule that generated the alarmro
OCTET STRING
.1.3.6.1.4.1.18418.9.1.4
alarmDescrDescription of the Rule that generated the alarmro
OCTET STRING
.1.3.6.1.4.1.18418.9.1.5
alarmTriggerThe trigger that generated the alarmro
Counter64
.1.3.6.1.4.1.18418.9.1.6
alarmCriteriaThe criteria that generated the alarmro
Unsigned32
.1.3.6.1.4.1.18418.9.1.7
alarmTypeThe type of the alarmrw
Unsigned32
.1.3.6.1.4.1.18418.9.1.8
alarmSeverityThe severity of the alarmro
Unsigned32
.1.3.6.1.4.1.18418.9.1.9
shogunEventTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.9.3
shogunNotificationPrefix
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.9.3.0
eventNotificationAn eventNotification trap indicates that an application integrated with Shogun has generated an Event that requires the attention of the system administrator.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.9.3.0.1
alarmRaisedNotificationAn alarmRaisedNotification trap indicates that an alarm that requires the attention of the system administrator was raised.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.9.3.0.2
alarmClearedNotificationAn alarmClearedNotification trap indicates that an alarm that was raised previously was cleared.
NOTIFICATION-TYPE
.1.3.6.1.4.1.18418.9.3.0.3
shogunConfContainer for Endace appliances MIB conformance groups.
OBJECT IDENTIFIER
.1.3.6.1.4.1.18418.9.4
shogunNotifyGroupGeneral alarm-specific notifications shared among Endace applications.
Unknown
.1.3.6.1.4.1.18418.9.4.1
shogunObjectGroupGeneral alarm-specific managed objects shared among Endace applications.
Unknown
.1.3.6.1.4.1.18418.9.4.2