Home/Catalog/ED-5000-MIB

ED-5000-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for ED-5000-MIB.

60
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

60 total
Object Name
mcData
OBJECT IDENTIFIER
.1.3.6.1.4.1.289
RFC1155-SMI
Unknown
.1.3.6.1.4.1.289
ed5000PortScnAn ed5000PortScn(1) is generated whenever a Fc_Port changes its operational state. For instance, the Fc_Port goes from on-line to offline.
TRAP-TYPE
.1.3.6.1.4.1.289.0.1
ed5000FruScnAn ed5000FruScn(2) is generated whenever a FRU status changes its operational state.
TRAP-TYPE
.1.3.6.1.4.1.289.0.2
commDev
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2
fibreChannel
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2.1
fcSwitch
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2.1.1
ed-5000
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2.1.1.1
ed5000Sys
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2.1.1.1.1
ed5000SysCurrentDateThe current date information.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.1
ed5000SysBootDateThe date and time of the last IPLro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.2
ed5000SysFirmwareVersionThe current version of the firmware.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.3
ed5000SysTypeNumThis object identifies ASCII type number for the unit.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.4
ed5000SysModelNumThis object identifies ASCII model number for the unit.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.5
ed5000SysMfgThis object identifies ASCII manufacturer for the unit.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.6
ed5000SysPlantOfMfgThis object identifies ASCII plant of manufacturer for the unit.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.7
ed5000SysSeqNumThis object identifies ASCII sequence number for the unit.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.8
ed5000SysEcLevelThis object identifies ASCII EC level ID for the unit.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.9
ed5000SysOemSerialNumThis object identifies ASCII OEM serial number for the unitro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.10
ed5000SysOperStatusThe current operational status of the switch. The values are defined as follow: operational (1), redundant-failure (2), minor-failure (3), major-failure (4), not-operational (5).ro
Ed5000SysOperStatus
.1.3.6.1.4.1.289.2.1.1.1.1.11
ed5000SysStateIf the edOperStatus of the switch is operational, the switch will be in one of the four states: online(1), coming-online(2), offline(3), and going-offline(4).ro
Ed5000SysState
.1.3.6.1.4.1.289.2.1.1.1.1.12
ed5000SysAdmStatusThe desired administrative status of the switch. A management station may place the switch in a desired state by setting this object accordingly. The desired administrative status are online(1) and offline(2). The online means setting the switch to be accessible by an external Fibre Channel port, and offline means setting the switch to be inaccessible.rw
Enumeration
.1.3.6.1.4.1.289.2.1.1.1.1.13
ed5000Fru
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2.1.1.1.2
ed5000FruTableA table that contains one entry for each module.
SEQUENCE OF Ed5000FruEntry
.1.3.6.1.4.1.289.2.1.1.1.2.1
ed5000FruEntryAn entry containing the service parameters of the module.
Ed5000FruEntry
.1.3.6.1.4.1.289.2.1.1.1.2.1.1
ed5000FruCodeField Replaceable Unit. A hardware component of the product that is replaceable as an entire unit. Each module defined in this MIB has a fixed FRU code. The values are defined as follow: fru-none (0) , fru-bkplane (1), fru-ctp (2), fru-mpc (3), fru-cmm (4), fru-fan (5), fru-power (6), fru-panel (7), fru-gsm (8), fru-gls (9), fru-glx (10), fru-lsm (11), fru-gxx (12).ro
Ed5000FruCode
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.1
ed5000FruPositionThis object identifies the position of the module. Port cards start from 1 to 8. All other cards start from 1 to 1 or 2.ro
Ed5000FruPosition
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.2
ed5000FruStatusThis object identifies the operational status of the module. The active(1) state indicates that the current module is active. The backup(2) state indicates that the back up module is used. update-busy (3) state indicates that the module is in the updating process. The failed(4) state indicates that the current module is failed.ro
Ed5000FruStatus
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.3
ed5000FruPartNumberThis object identifies the part number of the module.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.4
ed5000FruSerialNumberThis object identifies the serial number of the module.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.5
ed5000FruPowerOnHoursThis object indicates the number of the hours that the FRU has been in operation.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.6
ed5000FruTestDateThis object indicates final test date of the module.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.7
ed5000Port
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2.1.1.1.3
ed5000PortTableA table that contains one entry for each switch port (stitch only).
SEQUENCE OF Ed5000PortEntry
.1.3.6.1.4.1.289.2.1.1.1.3.1
ed5000PortEntryAn entry containing the information of the switch port.
Ed5000PortEntry
.1.3.6.1.4.1.289.2.1.1.1.3.1.1
ed5000PortIndexThis object identifies the switch port.ro
Ed5000PortIndex
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.1
ed5000PortPhyStateThis object identifies the physical state of the port.ro
Ed5000PortPhyState
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.2
ed5000PortOpStatusThis object identifies the operational status of the port. The online state indicates that user frames can be passed.ro
Ed5000PortStatus
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.3
ed5000PortAdmStatusThe desired state of the port. A management station may place the port in a desired state by setting this object accordingly. The testing(3) state indicates that no user frames can be passed. As the result of either explicit management action or per configuration information accessible by the switch, ed5000PortAdmStatus is then changed to either the online(1) or testing(3) states, or remains in the offline state.rw
Ed5000PortAdmStatus
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.4
ed5000PortTxWordsThis object counts the number of Fibre Channel words that the port has transmitted.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.11
ed5000PortRxWordsThis object counts the number of Fibre Channel words that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.12
ed5000PortTxFramesThis object counts the number of (Fibre Channel) frames that the port has transmitted.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.13
ed5000PortRxFramesThis object counts the number of (Fibre Channel) frames that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.14
ed5000PortRxC2FramesThis object counts the number of Class 2 frames that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.15
ed5000PortRxC3FramesThis object counts the number of Class 3 frames that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.16
ed5000PortRxLCsThis object counts the number of Link Control frames that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.17
ed5000PortRxMcastsThis object counts the number of Multicast frames that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.18
ed5000PortTooManyRdysThis object counts the number of 2.26 micro second intervals where the transmission of RDYs has priority over the transmission of frame traffic. (In 2.x releases and below, this counter gets incremented continuously and therefore has no meaning. In release 3.0 and above, it is always 0.)ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.19
ed5000PortNoTxCreditsThis object counts the amount of time that frame transmission is blocked by a transmit credit of zero. This is sampled once every 120 53.125 MHZ clocks, and the counter is incremented by 1 if the condition is true.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.20
ed5000PortRxEncFrsThis object counts the number of encoding error or disparity error inside or outside frames received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.21
ed5000PortRxCrcsThis object counts the number of CRC errors detected for frames received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.22
ed5000PortRxTruncsThis object counts the number of truncated frames that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.23
ed5000PortRxTooLongsThis object counts the number of received frames that are too long.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.24
ed5000PortRxBadEofsThis object counts the number of received frames that have bad EOF delimiter.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.25
ed5000PortRxBadOsThis object counts the number of invalid Ordered Sets received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.26
ed5000PortC3DiscardsThis object counts the number of Class 3 frames that the port has discarded.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.27
ed5000PortMcastTimedOutsThis object counts the number of Multicast frames that has been timed out.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.28
ed5000PortTxMcastsThis object counts the number of Multicast frames that has been transmitted.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.29
ed5000PortTxThroughputThis object presents the Bps transmission rate.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.30
ed5000PortRxThroughputThis object presents the Bps reception rate.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.31
ED-5000-MIB - SNMP MIB Reference | MIBs Explorer