Home/Catalog/ED-1032-MIB

ED-1032-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for ED-1032-MIB.

60
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

60 total
Object Name
mcData
OBJECT IDENTIFIER
.1.3.6.1.4.1.289
RFC1155-SMI
Unknown
.1.3.6.1.4.1.289
ed1032PortScnAn ed1032PortScn(1) is generated whenever a Fc_Port changes its operational state. For instance, the Fc_Port goes from on-line to offline.
TRAP-TYPE
.1.3.6.1.4.1.289.0.1
ed1032FruScnAn ed1032FruScn(2) is generated whenever a FRU status changes its operational state.
TRAP-TYPE
.1.3.6.1.4.1.289.0.2
commDev
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2
fibreChannel
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2.1
fcSwitch
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2.1.1
ed-1032
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2.1.1.1
ed1032Sys
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2.1.1.1.1
ed1032SysCurrentDateThe current date information.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.1
ed1032SysBootDateThe date and time of the last IPLro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.2
ed1032SysFirmwareVersionThe current version of the firmware.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.3
ed1032SysTypeNumThis object identifies ASCII type number for the unit.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.4
ed1032SysModelNumThis object identifies ASCII model number for the unit.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.5
ed1032SysMfgThis object identifies ASCII manufacturer for the unit.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.6
ed1032SysPlantOfMfgThis object identifies ASCII plant of manufacturer for the unit.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.7
ed1032SysSeqNumThis object identifies ASCII sequence number for the unit.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.8
ed1032SysEcLevelThis object identifies ASCII EC level ID for the unit.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.9
ed1032SysOemSerialNumThis object identifies ASCII OEM serial number for the unit.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.1.10
ed1032SysOperStatusThe current operational status of the switch. The values are defined as follow: operational (1), redundant-failure (2), minor-failure (3), major-failure (4), not-operational (5).ro
Ed1032SysOperStatus
.1.3.6.1.4.1.289.2.1.1.1.1.11
ed1032SysStateIf the edOperStatus of the switch is operational, the switch will be in one of the four states: online(1), coming-online(2), offline(3), and going-offline(4).ro
Ed1032SysState
.1.3.6.1.4.1.289.2.1.1.1.1.12
ed1032SysAdmStatusThe desired administrative status of the switch. A management station may place the switch in a desired state by setting this object accordingly. The desired administrative status are online(1) and offline(2). The online means setting the switch to be accessible by an external Fibre Channel port, and offline means setting the switch to be inaccessible.rw
Enumeration
.1.3.6.1.4.1.289.2.1.1.1.1.13
ed1032Fru
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2.1.1.1.2
ed1032FruTableA table that contains one entry for each module.
SEQUENCE OF Ed1032FruEntry
.1.3.6.1.4.1.289.2.1.1.1.2.1
ed1032FruEntryAn entry containing the service parameters of the module.
Ed1032FruEntry
.1.3.6.1.4.1.289.2.1.1.1.2.1.1
ed1032FruCodeField Replaceable Unit. A hardware component of the product that is replaceable as an entire unit. Each module defined in this MIB has a fixed FRU code. The values are defined as follow: fru-none (0) , fru-bkplane (1), fru-ctp (2), fru-mpc (3), fru-cmm (4), fru-fan (5), fru-power (6), fru-panel (7), fru-gsm (8), fru-gls (9), fru-glx (10), fru-lsm (11), fru-gxx (12).ro
Ed1032FruCode
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.1
ed1032FruPositionThis object identifies the position of the module. Port cards start from 1 to 8. All other cards start from 1 to 1 or 2.ro
Ed1032FruPosition
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.2
ed1032FruStatusThis object identifies the operational status of the module. The active(1) state indicates that the current module is active. The backup(2) state indicates that the back up module is used. update-busy (3) state indicates that the module is in the updating process. The failed(4) state indicates that the current module is failed.ro
Ed1032FruStatus
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.3
ed1032FruPartNumberThis object identifies the part number of the module.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.4
ed1032FruSerialNumberThis object identifies the serial number of the module.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.5
ed1032FruPowerOnHoursThis object indicates the number of the hours that the FRU has been in operation.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.6
ed1032FruTestDateThis object indicates final test date of the module.ro
DisplayString
.1.3.6.1.4.1.289.2.1.1.1.2.1.1.7
ed1032Port
OBJECT IDENTIFIER
.1.3.6.1.4.1.289.2.1.1.1.3
ed1032PortTableA table that contains one entry for each switch port (stitch only).
SEQUENCE OF Ed1032PortEntry
.1.3.6.1.4.1.289.2.1.1.1.3.1
ed1032PortEntryAn entry containing the information of the switch port.
Ed1032PortEntry
.1.3.6.1.4.1.289.2.1.1.1.3.1.1
ed1032PortIndexThis object identifies the switch port.ro
Ed1032PortIndex
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.1
ed1032PortPhyStateThis object identifies the physical state of the port.ro
Ed1032PortPhyState
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.2
ed1032PortOpStatusThis object identifies the operational status of the port. The online state indicates that user frames can be passed.ro
Ed1032PortStatus
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.3
ed1032PortAdmStatusThe desired state of the port. A management station may place the port in a desired state by setting this object accordingly. The testing(3) state indicates that no user frames can be passed. As the result of either explicit management action or per configuration information accessible by the switch, ed1032PortAdmStatus is then changed to either the online(1) or testing(3) states, or remains in the offline state.rw
Ed1032PortAdmStatus
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.4
ed1032PortTxWordsThis object counts the number of Fibre Channel words that the port has transmitted.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.11
ed1032PortRxWordsThis object counts the number of Fibre Channel words that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.12
ed1032PortTxFramesThis object counts the number of (Fibre Channel) frames that the port has transmitted.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.13
ed1032PortRxFramesThis object counts the number of (Fibre Channel) frames that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.14
ed1032PortRxC2FramesThis object counts the number of Class 2 frames that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.15
ed1032PortRxC3FramesThis object counts the number of Class 3 frames that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.16
ed1032PortRxLCsThis object counts the number of Link Control frames that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.17
ed1032PortRxMcastsThis object counts the number of Multicast frames that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.18
ed1032PortTooManyRdysThis object counts the number of times when RDYs exceeds the frames received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.19
ed1032PortNoTxCreditsThis object counts the amount of time that frame transmission is blocked by a transmit credit of zero. This is sampled once every 120 53.125 MHZ clocks, and the counter is incremented by 1 if the condition is true.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.20
ed1032PortRxEncFrsThis object counts the number of encoding error or disparity error inside or outside frames received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.21
ed1032PortRxCrcsThis object counts the number of CRC errors detected for frames received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.22
ed1032PortRxTruncsThis object counts the number of truncated frames that the port has received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.23
ed1032PortRxTooLongsThis object counts the number of received frames that are too long.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.24
ed1032PortRxBadEofsThis object counts the number of received frames that have bad EOF delimiter.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.25
ed1032PortRxBadOsThis object counts the number of invalid Ordered Sets received.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.26
ed1032PortC3DiscardsThis object counts the number of Class 3 frames that the port has discarded.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.27
ed1032PortMcastTimedOutsThis object counts the number of Multicast frames that has been timed out.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.28
ed1032PortTxMcastsThis object counts the number of Multicast frames that has been transmitted.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.29
ed1032PortTxThroughputThis object presents the Bps transmission rate.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.30
ed1032PortRxThroughputThis object presents the Bps reception rate.ro
Counter
.1.3.6.1.4.1.289.2.1.1.1.3.1.1.31
ED-1032-MIB - SNMP MIB Reference | MIBs Explorer