DOCS-TEST-MIB
This is the MIB Module supporting programmable test features for DOCSIS 2.0 compliant Cable Modems (CM) and Cable Modem Termination Systems (CMTS).
Main OID:
docsTestMIB.1.3.6.1.4.1.4491.2.1.12
23
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
23 total| Object Name |
|---|
cableLabs OBJECT IDENTIFIER .1.3.6.1.4.1.4491 |
clabFunction OBJECT IDENTIFIER .1.3.6.1.4.1.4491.1 |
clabFuncMib2 OBJECT IDENTIFIER .1.3.6.1.4.1.4491.1.1 |
clabFuncProprietary OBJECT IDENTIFIER .1.3.6.1.4.1.4491.1.2 |
clabProject OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2 |
clabProjDocsis OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.1 |
docsTestMIBThis is the MIB Module supporting programmable test features for DOCSIS 2.0 compliant Cable Modems (CM) and Cable Modem Termination Systems (CMTS). MODULE-IDENTITY .1.3.6.1.4.1.4491.2.1.12 |
docsTestMibObjects OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.1.12.1 |
docsTestBaseObjects OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.1.12.1.1 |
docsTestCapabilityIndicates the ability of this device to support the programmable features identified by the TYPE field from the CM/CMTS TLV table in [17]. Each octet within this octet string represents eight tests. For example, the first octet represents tests one through eight (with the msb representing test one) as identified by the TYPE field.ro OCTET STRING .1.3.6.1.4.1.4491.2.1.12.1.1.1 |
docsTestStatusIndicates the current operating status of tests initiated through the docsTestSetupObjects. The octet representation is identical to that used by docsTestCapability. A bit representation of one indicates that a test is currently active, while zero indicates the test is inactive or has completed.ro OCTET STRING .1.3.6.1.4.1.4491.2.1.12.1.1.2 |
docsTestSetupObjects OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.1.12.1.2 |
docsTestTypeCorresponds to the TYPE field from the CM/CMTS TLV Table in [17]. The default value of zero indicates no test has yet been initiated. A WrongValueError should be returned in response to a write request for a test not supported by the device. A read request will return the docsTestType value last successfully written, whether that test is active or inactive.rw Integer32 .1.3.6.1.4.1.4491.2.1.12.1.2.1 |
docsTestDataThe OCTET STRING length and value correspond to the LENGTH and VALUE fields from the CM/CMTS TLV Table in [17]. A read request will return the docsTestData value last successfully written, whether that test is active or inactive.rw OCTET STRING .1.3.6.1.4.1.4491.2.1.12.1.2.2 |
docsTestEnableUsed to initiate or stop the tests setup through the docsTestType and docsTestData objects. A CommitFailedError should be returned in response to a TRUE Write request if the values in docsTestType and docsTestData are incompatible, or a test could not be initiated for any other reason.rw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.4491.2.1.12.1.2.3 |
docsTestConformance OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.1.12.2 |
docsTestCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.1.12.2.1 |
docsTestBasicComplianceThe compliance statement for devices that implement the DOCSIS compliant programmable test features. Unknown .1.3.6.1.4.1.4491.2.1.12.2.1.1 |
docsTestGroups OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.1.12.2.2 |
docsTestGroupGroup of objects implemented in both Cable Modems and Cable Modem Termination Systems. Unknown .1.3.6.1.4.1.4491.2.1.12.2.2.1 |
clabProjPacketCable OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.2 |
clabProjOpenCable OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.3 |
clabProjCableHome OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.4 |