Home/Catalog/DL-NEW-DSX1-MIB

DL-NEW-DSX1-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for DL-NEW-DSX1-MIB.

260
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

260 total
Object Name
RFC1213-MIB
Unknown
.1.3.6.1.4.1.300
dl-new-t1
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200
startTestSent upon the initiation of a new test condition.
TRAP-TYPE
.1.3.6.1.4.1.300.200.0.1
endTestSent upon the termination of a test condition.
TRAP-TYPE
.1.3.6.1.4.1.300.200.0.2
startAlarmIndicates the beginning of a new alarm condition.
TRAP-TYPE
.1.3.6.1.4.1.300.200.0.3
endAlarmIndicates the end of an alarm condition.
TRAP-TYPE
.1.3.6.1.4.1.300.200.0.4
manualConfigChangeGenerated when the configuration was changed manually on the unit.
TRAP-TYPE
.1.3.6.1.4.1.300.200.0.5
dlcUnitHwConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.1
dlcUnitModelTypeThe unit model type.ro
Enumeration
.1.3.6.1.4.1.300.200.1.1
dlcUnitHwRevThe ASCII code of the hardware revision number.ro
DisplayString
.1.3.6.1.4.1.300.200.1.2
dlcUnitHwOptionsA bit map, reported as the sum of all the values that correspond to installed options: realTimeClock ( 1) netPortT1 ( 2) netPortE1 ( 4) auxPortT1 ( 8) auxPortE1 ( 16) otherNetT1 ( 32) otherNetE1 ( 64) reserved1 (128) reserved2 (256) reserved3 (512) `netPortT1' and `netPortE1' are mutually exclusive and one of the two will always be TRUE. `auxPortT1' and `auxPortE1' are mutually exclusive; if both are FALSE, there is no AUX port present. `otherNetT1' and `otherNetE1' are mutually exclusive; if both are FALSE, there is no CSU port present.ro
INTEGER ( 0..1023 )
.1.3.6.1.4.1.300.200.1.3
dlcUnitSwRevThe ASCII code of the software revision number.ro
DisplayString
.1.3.6.1.4.1.300.200.1.4
dlcUnitDataPortsThe number of data ports installed on the unit.ro
INTEGER
.1.3.6.1.4.1.300.200.1.5
dlcUnitRamThe amount of usable ram in the unit, in KBytes.ro
INTEGER
.1.3.6.1.4.1.300.200.1.6
dlcUnitRomThe amount of usable rom in the unit, in KBytes.ro
INTEGER
.1.3.6.1.4.1.300.200.1.7
dlcUnitFlashThe amount of FLASH ROM in the unit, in KBytes. If dlcUnitFlash is 0, the Downloadable Code option is not installed.ro
INTEGER
.1.3.6.1.4.1.300.200.1.8
dlcUnitSlotNumThe slot number the unit is in. If it's a stand alone unit, this object will return 0.ro
INTEGER
.1.3.6.1.4.1.300.200.1.9
dlcUnitMibRevThe ASCII code of the MIB revision number.ro
DisplayString
.1.3.6.1.4.1.300.200.1.10
dlcUnitFeaturesFeature configuration for Solo Select. The value returned is a bit mask of which feature key is on/capable when the corresponding bit is 1.ro
Enumeration
.1.3.6.1.4.1.300.200.1.11
dlcUnitConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.2
dlcUnitIdA name that uniquely and globally identifies the unit. The Unit ID must consist of (upper-case) letters 'A'..'Z' and digits '0'..'9'. The first character of the Unit ID may not be a digit.rw
DisplayString
.1.3.6.1.4.1.300.200.2.1
dlcUnitProtectModeWhen true, the unit configuration can not be changed from the front panel nor can tests be initiated or terminated from the front panel.rw
Boolean
.1.3.6.1.4.1.300.200.2.2
dlcUnitYellowEnableWhen false, yellow alarm conditions are ignored when received from a Dsx1 port, and the unit will never transmit a Yellow Alarm signal on a Dsx1 port. This applies to all ports: mainNet, aux, otherNet.rw
Boolean
.1.3.6.1.4.1.300.200.2.3
dlcUnitNetPassFdlIndicates which Dsx1 DTE port's FDL is connected to the `mainNet' FDL when this unit has no traffic of its own. Meaninigful values are `aux', `otherNet', and `noPort'.rw
PortId
.1.3.6.1.4.1.300.200.2.4
dlcUnitMainClockSourceThis is the primary transmit timing source.rw
PortId
.1.3.6.1.4.1.300.200.2.5
dlcUnitAltClockSourceThis is the alternate transmit timing source. It is used when the primary source is not available.rw
PortId
.1.3.6.1.4.1.300.200.2.6
dlcUnitExtClockRateThe signal arriving at the BNC connector on the back of the unit, in units of KHz. Must be a multiple of 56 or 64 KHz (n*56 or n*64) or 1544. For T1 units, the largest acceptable value is 1544. For E1 units, the value can go up to 2048. For Solo CSU products, the value is fixed at 1544 and cannot be changed.rw
INTEGER
.1.3.6.1.4.1.300.200.2.7
dlcUnitFullBandwidthLoopCodeDetermines the loop codes we transmit for the Full Bandwidth Loop Up Remote and Loop Down Remote tests and the code we respond to when it's received on the NET port. For the fullBandwidthLoopCode, `v54' is an invalid value.rw
LoopCodeType
.1.3.6.1.4.1.300.200.2.8
dlcUnitFractionalLoopCodeDetermines the loop codes we transmit for the Fractional Loop Up Remote and Loop Down Remote tests and the code we respond to when it's received on fractional bandwidth.rw
LoopCodeType
.1.3.6.1.4.1.300.200.2.9
dlcUnitTestLengthDetermines the time interval after which tests are automatically terminated. Valid values are 0, 1, 15 and 60. 0 stands for unlimited, 1 for 1 minute, 15 for 15 minutes and 60 for 60 minutes.rw
INTEGER
.1.3.6.1.4.1.300.200.2.10
dlcUnitUserPattern1This is a sequence of the characters '0' and '1' that represents the first of two user patterns. The first character represents the first bit in the sequence.rw
DisplayString
.1.3.6.1.4.1.300.200.2.11
dlcUnitUserPattern2This is a sequence of the characters '0' and '1' that represents the second of two user patterns. The first character represents the first bit in the sequence.rw
DisplayString
.1.3.6.1.4.1.300.200.2.12
dlcUnitBlockAllAlarmsWhen dlcUnitBlockAllAlarms is TRUE, the unit will never send any traps.rw
Boolean
.1.3.6.1.4.1.300.200.2.13
dlcUnitDsx1TrapEnableTableA list of traps that are related to a Dsx1 port.
SEQUENCE OF DlcDsx1TrapEnableEntry
.1.3.6.1.4.1.300.200.2.14
dlcDsx1TrapEnableEntryAn entry in the Dsx1 Trap Enable table.
DlcDsx1TrapEnableEntry
.1.3.6.1.4.1.300.200.2.14.1
dlcDsx1TrapPortIdUniquely identifies this port. Valid values are `mainNet', `aux', `otherNet'.ro
PortId
.1.3.6.1.4.1.300.200.2.14.1.1
dlcDsx1BpvThresholdTrapDefines Bipolar Violation Error Rate threshold in units of BPV errors per minute. When this threshold is exceeded, the unit will send a trap to the SNMP manager. The threshold is of the form M x 10 ^ -E where M is a mantissa and E the exponent. Both are single digit values. M and E are represented in this value as one number: (M) x 10 + (E). For example, the threshold 7x10^-3 BPVs/min is encoded as the integer 73. A value of 0 disables the trap altogether. Valid values for dlcDsx1BpvThresholdTrap are: 13 23 33 43 53 63 14 24 34 44 54 64 74 84 94 15 25 35 45 55 65 75 85 95 16 26 36 46 56 66 76 86 96 17 27 37 47 57 67 77 87 97 28 38 48 58 68 78 88 98 or, from 6E-3 to 2E-8. N.B. The BPV Threshold Alarm exists only for the mainNet and otherNet Port IDs, so setting the Threshold for the aux PortId will always fail. The BPV Threshold is always reported as 0 for the aux PortId.rw
INTEGER ( 0..99 )
.1.3.6.1.4.1.300.200.2.14.1.2
dlcDsx1OofThresholdTrapDefines the Out Of Frame Error Rate threshold in units of OOF errors per minute. The threshold is encoded the same as dlcDsx1BpvThresholdTrap. A value of 0 disables the trap altogether. Valid values for dlcDsx1OofThresholdTap are: 12 22 22 42 52 62 72 13 23 33 43 53 63 73 83 93 14 24 34 44 54 64 74 84 94 15 25 35 45 55 65 75 85 95 36 46 56 66 76 86 96 or, from 7E-2 to 3E-6. N.B. The OOF Threshold Alarm exists only for the mainNet and otherNet Port IDs, so setting the Threshold for the aux PortId will always fail. The OOF Threshold is always reported as 0 for the aux PortId.rw
INTEGER ( 0..99 )
.1.3.6.1.4.1.300.200.2.14.1.3
dlcDsx1CrcThresholdTrapDefines the CRC-6 Error Rate threshold in units of CRC errors per minute. The threshold is encoded the same as dlcDsx1BpvThresholdTrap. A value of 0 disables the trap altogether. Valid values for dlcDsx1CrcThresholdTrap are: 10 11 21 31 41 51 61 71 81 91 12 22 32 42 52 62 72 82 92 13 23 33 43 53 63 73 83 93 14 24 34 44 54 64 74 84 94 55 65 75 85 95 or, from 1E0 to 5E-5. N.B. The CRC Threshold Alarm exists only for the mainNet and otherNet Port IDs, so setting the Threshold for the aux PortId will always fail. The CRC Threshold is always reported as 0 for the aux PortId.rw
INTEGER ( 0..99 )
.1.3.6.1.4.1.300.200.2.14.1.4
dlcDsx1LossOfSignalTrapEnableEnables or disables a trap upon loss of network signal (LOS) on a Dsx1 port.rw
Boolean
.1.3.6.1.4.1.300.200.2.14.1.5
dlcDsx1LossOfSyncTrapEnableEnables or disables a trap upon loss of network framing (LOF) on a Dsx1 port.rw
Boolean
.1.3.6.1.4.1.300.200.2.14.1.6
dlcDsx1ReceiveAIStrapEnableEnables or disables a trap upon detection of AIS (Blue Alarm Signal) on a Dsx1 port.rw
Boolean
.1.3.6.1.4.1.300.200.2.14.1.7
dlcDsx1ReceiveYellowAlarmTrapEnableEnables or disables a trap upon detection of Yellow Alarm Signal on a Dsx1 port.rw
Boolean
.1.3.6.1.4.1.300.200.2.14.1.8
dlcDsx1ReceiveRemoteAlarmTrapEnableEnables or disables a trap upon detection of Remote Alarm Indicator on an E1 Dsx1 port. For T1 units, this object's value will always be read as 0 and set operations will succeed, but the value will not be changed.rw
Boolean
.1.3.6.1.4.1.300.200.2.14.1.9
dlcDsx1PSfailureTrapEnableEnables or disables a trap upon a power supply failure. This object doesn't really belong in the dlcDsx1TrapEnableTable. It is specific to units that are installed in a shelf. When accessing this object, the index (portId) is ignored.rw
Boolean
.1.3.6.1.4.1.300.200.2.14.1.10
dlcDsx1CntlCrdMissingTrapEnableEnables or disables a trap upon detection of a missing controller card. This object doesn't really belong in the dlcDsx1TrapEnableTable. It is specific to units that are installed in a shelf. When accessing this object, the index (portId) is ignored.rw
Boolean
.1.3.6.1.4.1.300.200.2.14.1.11
dlcDsx1FdlLinkTrapEnableEnables or disables a trap upon detection of the remote unit is not responding to DLC FDL messages.rw
Boolean
.1.3.6.1.4.1.300.200.2.14.1.12
dlcDsx1IbCrcThresholdTrapDefines the In-Band CRC Error Rate threshold in units of CRC errors per minute. The threshold is encoded the same as dlcDsx1BpvThresholdTrap. A value of 0 disables the trap altogether. For the Eclipse, valid values of dlcDsx1IbCrcThresholdTrap range from 47 to 91. N.B. The CRC Threshold Alarm exists only for the mainNet port.rw
INTEGER ( 0..99 )
.1.3.6.1.4.1.300.200.2.14.1.13
dlcDsx1InbandLinkTrapEnableEnables or disables a trap upon detection of the inband link.rw
Boolean
.1.3.6.1.4.1.300.200.2.14.1.14
dlcUnitDataDteLossTrapEnableTableEnables or disables a trap upon the loss of signal on a Data DTE port.
SEQUENCE OF DlcDataDteLossTrapEnableEntry
.1.3.6.1.4.1.300.200.2.15
dlcDataDteLossTrapEnableEntryAn entry in the Data DTE Loss Trap Enable table.
DlcDataDteLossTrapEnableEntry
.1.3.6.1.4.1.300.200.2.15.1
dlcDataLossPortIdUniquely identifies this port. Valid values are `data1' through `data32'.ro
PortId
.1.3.6.1.4.1.300.200.2.15.1.1
dlcDataLossEnableSays whether to enable this trap.rw
Boolean
.1.3.6.1.4.1.300.200.2.15.1.2
dlcUnitExternalAlarmInputTrapEnableEnables or disables a trap upon detection of an alarm condition on the External Alarm Input.rw
Boolean
.1.3.6.1.4.1.300.200.2.16
dlcUnitExternalAlarmInputContactsWhen set to normallyOpen, an alarm is declared when the contacts close ... and vice-versa.rw
Enumeration
.1.3.6.1.4.1.300.200.2.17
dlcUnitExternalAlarmInputMessageA character string that describes what's going on when an alarm on the External Alarm Input is detected.rw
DisplayString
.1.3.6.1.4.1.300.200.2.18
dlcUnitExternalAlarmOutputContactsWhen set to normallyOpen, the contacts close when any enabled alarm occurs and vice-versa. Pushing any button on the units Front Panel will cause the alarm contacts to open again until another alarm is recognized.rw
Enumeration
.1.3.6.1.4.1.300.200.2.19
dlcUnitExternalAlarmOutputTrapEnableEnables or disables the external alarm output contacts.rw
Boolean
.1.3.6.1.4.1.300.200.2.20
dlcUnitDsx1ConfigTableA table of configuration items for a Dsx1 port.
SEQUENCE OF DlcDsx1ConfigEntry
.1.3.6.1.4.1.300.200.2.21
dlcDsx1ConfigEntryAn entry in the Dsx1 configuration table.
DlcDsx1ConfigEntry
.1.3.6.1.4.1.300.200.2.21.1
dlcDsx1ConfigPortIdUniquely identifies this port. Valid values are `mainNet', `aux', `otherNet'.ro
PortId
.1.3.6.1.4.1.300.200.2.21.1.1
dlcDsx1FramingDsx1 framing type: T1 E1 Unstructured is E1 only, when in this mode, the E1 line acts like a 2048 Bps pipe with no framing information.rw
Enumeration
.1.3.6.1.4.1.300.200.2.21.1.2
dlcDsx1LineCodeDsx1 line code type, AMI or B8ZS. E1 lines are always HDB3.rw
Enumeration
.1.3.6.1.4.1.300.200.2.21.1.3
dlcDsx1LineMatchingDsx1 line build out or equalization: For a T1 NET port, LBO is 0, -7.5 or -15dB. For a T1 AUX port, EQ is 0..533 feet. For any E1 port, impedance is 75 or 120 Ohms.rw
Enumeration
.1.3.6.1.4.1.300.200.2.21.1.4
dlcDsx1DacsModeTrue if DACS mode is in effect for this port.rw
Boolean
.1.3.6.1.4.1.300.200.2.21.1.5
dlcDsx1UseDlcFdlProtocolTrue when DLC FDL protocol is enabled over this port's FDL.rw
Boolean
.1.3.6.1.4.1.300.200.2.21.1.6
dlcDsx1UseAnsiProtocolTrue if ANSI Dsx1.403 is enabled over the FDL.rw
Boolean
.1.3.6.1.4.1.300.200.2.21.1.7
dlcDsx1Bit7StuffingWhen true, bit 7 stuffing is turned on for a T1 Aux port to provide pulse density protection. Valid only on a T1 AUX port.rw
Boolean
.1.3.6.1.4.1.300.200.2.21.1.8
dlcDsx1InBandBitSpecifies which bit in Timeslot 1 of an E1 link is used to pass message traffic. Not implemented for T1 ports.rw
INTEGER
.1.3.6.1.4.1.300.200.2.21.1.9
dlcUnitDataDteConfigTableThe data DTE configuration table.
SEQUENCE OF DlcDataDteConfigEntry
.1.3.6.1.4.1.300.200.2.22
dlcDataDteConfigEntryAn entry in the data DTE configuration table.
DlcDataDteConfigEntry
.1.3.6.1.4.1.300.200.2.22.1
dlcDataConfigPortIdUniquely identifies this port. Valid values are `data1' through `data32'.ro
PortId
.1.3.6.1.4.1.300.200.2.22.1.1
dlcDataConfigEncodingData DTE encoding type.rw
Enumeration
.1.3.6.1.4.1.300.200.2.22.1.2
dlcDataConfigLossThe criterion to declare a Loss of Data DTE.rw
Enumeration
.1.3.6.1.4.1.300.200.2.22.1.3
dlcDataConfigModeIn dteMode the unit is the DTE and the external equipment the DCE.rw
Enumeration
.1.3.6.1.4.1.300.200.2.22.1.4
dlcDataConfigFormatSelects V.35 or RS449 format.rw
Enumeration
.1.3.6.1.4.1.300.200.2.22.1.5
dlcDataConfigTransmitTimingSelects the Data DTE tramsmit timing source. Can be SCTE, SCT or inverted SCT.rw
Enumeration
.1.3.6.1.4.1.300.200.2.22.1.6
dlcUnitMuxConfigTableThis is the timeslot map configuration.
SEQUENCE OF DlcMuxConfigEntry
.1.3.6.1.4.1.300.200.2.23
dlcMuxConfigEntryAn entry in the timeslot map.
DlcMuxConfigEntry
.1.3.6.1.4.1.300.200.2.23.1
dlcMuxConfigBusIdIdentifies which muxBus this timeslot is on.ro
Enumeration
.1.3.6.1.4.1.300.200.2.23.1.1
dlcMuxConfigSlotNumberUniquely identifies this timeslot.ro
INTEGER
.1.3.6.1.4.1.300.200.2.23.1.2
dlcMuxConfigPortIdSays which DTE port receives data from the indicated muxBus during this timeslot.rw
PortId
.1.3.6.1.4.1.300.200.2.23.1.3
dlcUnitSnmpConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.2.24
dlcSnmpUnitIpAddrSpecifies the IP address that is assigned to this unit.rw
IpAddress
.1.3.6.1.4.1.300.200.2.24.1
dlcSnmpUnitNetMaskSpecifies the net mask that this unit uses.rw
IpAddress
.1.3.6.1.4.1.300.200.2.24.2
dlcSnmpTrapAddr1Specifies the IP address of the management station to which this unit sends traps.rw
IpAddress
.1.3.6.1.4.1.300.200.2.24.3
dlcSnmpTrapAddr2Specifies the IP address of the management station to which this unit sends traps.rw
IpAddress
.1.3.6.1.4.1.300.200.2.24.4
dlcSnmpTrapAddr3Specifies the IP address of the management station to which this unit sends traps.rw
IpAddress
.1.3.6.1.4.1.300.200.2.24.5
dlcSnmpTrapDlci1Specifies the first of three DLCI value to which this unit sends TRAP PDUs.rw
Gauge
.1.3.6.1.4.1.300.200.2.24.6
dlcSnmpTrapDlci2Specifies the second of three DLCI value to which this unit sends TRAP PDUs.rw
Gauge
.1.3.6.1.4.1.300.200.2.24.7
dlcSnmpTrapDlci3Specifies the third of three DLCI value to which this unit sends TRAP PDUs.rw
Gauge
.1.3.6.1.4.1.300.200.2.24.8
dlcSnmpTrapDirection1Specifies the first of three Port to which this unit sends TRAP PDUs.rw
Enumeration
.1.3.6.1.4.1.300.200.2.24.9
dlcSnmpTrapDirection2Specifies the second of three Port to which this unit sends TRAP PDUs.rw
Enumeration
.1.3.6.1.4.1.300.200.2.24.10
dlcSnmpTrapDirection3Specifies the third of three Port to which this unit sends TRAP PDUs.rw
Enumeration
.1.3.6.1.4.1.300.200.2.24.11
dlcSnmpTrapDirectionSpecifies where this unit sends TRAP PDUs.rw
Enumeration
.1.3.6.1.4.1.300.200.2.24.12
dlcSnmpEthernetConfiguration
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.2.24.13
dlcEthernetIpAddrSpecifies the IP address of Ethernet port.rw
IpAddress
.1.3.6.1.4.1.300.200.2.24.13.1
dlcEthernetIpMaskSpecifies the subnet mask of Ethernet port.rw
IpAddress
.1.3.6.1.4.1.300.200.2.24.13.2
dlcEthernetGatewayAddrSpecifies the gateway address of Ethernet port.rw
IpAddress
.1.3.6.1.4.1.300.200.2.24.13.3
dlcEthernetMacAddrThe MAC address of the Ethernet port.ro
MacAddress (SNMPv2-TC)
.1.3.6.1.4.1.300.200.2.24.13.4
dlcUnitConfigTime
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.2.25
dlcUnitTimeYearThe unit's notion of the current year.rw
INTEGER
.1.3.6.1.4.1.300.200.2.25.1
dlcUnitTimeMonthThe unit's notion of the current month.rw
INTEGER
.1.3.6.1.4.1.300.200.2.25.2
dlcUnitTimeDayThe unit's notion of the current day.rw
INTEGER
.1.3.6.1.4.1.300.200.2.25.3
dlcUnitTimeHourThe the unit's notion of the current hour.rw
INTEGER
.1.3.6.1.4.1.300.200.2.25.4
dlcUnitTimeMinuteThe the unit's notion of the current minute.rw
INTEGER
.1.3.6.1.4.1.300.200.2.25.5
dlcUnitTimeSecondThe the unit's notion of the current second.rw
INTEGER
.1.3.6.1.4.1.300.200.2.25.6
dlcUnitSerialNumAn ID that uniquely and globally identifies the unit. A Serial Number must consist of printable ASCII characters 0x20 ..0x7E.ro
DisplayString
.1.3.6.1.4.1.300.200.2.26
dlcUnitModemConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.2.27
dlcModemPhoneNum1The first phone number to dial when the unit needs to set up a modem connection.rw
DisplayString
.1.3.6.1.4.1.300.200.2.27.1
dlcModemPhoneNum2The second phone number to try if the phone number failed in setting up a modem connection.rw
DisplayString
.1.3.6.1.4.1.300.200.2.27.2
dlcModemInitString1In setting up a modem connection, the first group of commands used to initialize the modem.rw
DisplayString
.1.3.6.1.4.1.300.200.2.27.3
dlcModemInitString2In setting up a modem connection, the second group of commands used to initialize the modem. There is a delay between sending the first and second groups of initialzation commands.rw
DisplayString
.1.3.6.1.4.1.300.200.2.27.4
dlcUnitInbandModeThe type of traffic expected on the link for inband management and IPM.ro
Enumeration
.1.3.6.1.4.1.300.200.2.28
dlcUnitDialOutTimeIntervalA time interval for the dialout. The value should be between 0 and 255.rw
INTEGER
.1.3.6.1.4.1.300.200.2.29
dlcAlarmSignalFramed/unframed aux alarm signal optionrw
FramedUnframed
.1.3.6.1.4.1.300.200.2.30
dlcUnitIdleCodeIdle Code that is send on unassigned time slotsrw
INTEGER
.1.3.6.1.4.1.300.200.2.31
dlcRemoteCommunicationsModeFramed/unframed aux alarm signal optionrw
RemoteCommunicationsMode
.1.3.6.1.4.1.300.200.2.32
dlcUnitConfigLinkTest
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.2.33
dlcLinkTestStateSpecifies the status configuration of link based test. Only setable to values disabled(1) and enabled(2) to end and start the test respectively. Values running(3) and idle(4) are returned for status of the test.rw
Enumeration
.1.3.6.1.4.1.300.200.2.33.1
dlcLinkTestAddressSpecifies the address for the next link based test to run.rw
IpAddress
.1.3.6.1.4.1.300.200.2.33.2
dlcLinkTestDlciSpecifies the frame relay DLCI for the next link based test to run. This value is used when the unit is in frameRelay InbandMode only and if the next link based test is not done on the commPort.rw
INTEGER ( 0..1023 )
.1.3.6.1.4.1.300.200.2.33.3
dlcLinkTestPortSpecifies which port to run the next link based test.rw
Enumeration
.1.3.6.1.4.1.300.200.2.33.4
dlcLinkTestLengthSpecifies the time length of the next test to run in minutes.rw
INTEGER
.1.3.6.1.4.1.300.200.2.33.5
dlcLinkTestIntervalSpecifies the repetition interval in seconds between packets for the next link based test.rw
INTEGER
.1.3.6.1.4.1.300.200.2.33.6
dlcLinkTestPacketSizeSpecifies the packet size for the next link based test.rw
INTEGER
.1.3.6.1.4.1.300.200.2.33.7
dlcLinkTestPatternSpecifies the test pattern for the next link based test.rw
Enumeration
.1.3.6.1.4.1.300.200.2.33.8
dlcUnitInbandConfigWhen true (== 2), inband management is enabled.ro
Boolean
.1.3.6.1.4.1.300.200.2.34
dlcUnitInbandTrafficTypeThe type of traffic expected on the link for inband management and IPM.ro
Enumeration
.1.3.6.1.4.1.300.200.2.35
dlcUnitPerformanceMonitoringWhen true (== 2), the integrated performance monitoring (IPM) is enabledrw
Boolean
.1.3.6.1.4.1.300.200.2.36
dlcUnitPvcAutoDiscoveryWhen true (== 2), automatic discovery of DLCIs is enabledrw
Boolean
.1.3.6.1.4.1.300.200.2.37
dlcUnitDelayMonitorConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.2.38
dlcDelayMonitorConfigTableTable of Delay Monitor test configuration.
SEQUENCE OF DlcDelayMonitorConfigEntry
.1.3.6.1.4.1.300.200.2.38.1
dlcDelayMonitorConfigEntryAn entry in the network configuration table.
DlcDelayMonitorConfigEntry
.1.3.6.1.4.1.300.200.2.38.1.1
dlcDelayMonitorConfigIndexUniquely identifies which delay monitor test in the configuration table.ro
INTEGER ( 1..4 )
.1.3.6.1.4.1.300.200.2.38.1.1.1
dlcDelayMonitorStateSpecifies the status configuration of this delay monitor. Only setable to values disabled(1) and enabled(2) to end and start the test respectively. Values running(3) and idle(4) are returned for status of the test.rw
Enumeration
.1.3.6.1.4.1.300.200.2.38.1.1.2
dlcDelayMonitorTargetAddressSpecifies the address for the next delay monitor to run.rw
IpAddress
.1.3.6.1.4.1.300.200.2.38.1.1.3
dlcDelayMonitorDlciSpecifies the frame relay DLCI for the next delay monitor to run. This value is used when the unit is in frameRelay InbandMode only and if the next delay monitor is not done on the commPort.rw
INTEGER ( 0..1023 )
.1.3.6.1.4.1.300.200.2.38.1.1.4
dlcDelayMonitorPortSpecifies which port to run the next delay monitor.rw
Enumeration
.1.3.6.1.4.1.300.200.2.38.1.1.5
dlcDelayMonitorIntervalSpecifies the repetition interval in seconds between packets for the next delay monitor to run.rw
INTEGER
.1.3.6.1.4.1.300.200.2.38.1.1.6
dlcDelayMonitorPacketSizeSpecifies the packet size for the next delay monitor.rw
INTEGER
.1.3.6.1.4.1.300.200.2.38.1.1.7
dlcDelayMonitorPatternSpecifies the test pattern for the next delay monitor.rw
Enumeration
.1.3.6.1.4.1.300.200.2.38.1.1.8
dlcDLCItableTable for current DLCI
SEQUENCE OF DlcDLCItableEntry
.1.3.6.1.4.1.300.200.2.39
dlcDLCItableEntryAn entry for a DLCI
DlcDLCItableEntry
.1.3.6.1.4.1.300.200.2.39.1
dlcDLCInumberIdentifies DLCI number.ro
INTEGER
.1.3.6.1.4.1.300.200.2.39.1.1
dlcDTECIRThis DLCI's DTE Confirmed Information Rate (CIR)ro
INTEGER
.1.3.6.1.4.1.300.200.2.39.1.2
dlcNETCIRThis DLCI's NET Confirmed Information Rate (CIR)ro
INTEGER
.1.3.6.1.4.1.300.200.2.39.1.3
dlcDLCIstatusThis object represents status of the entry. When read, it will return status 'active' or 'inactive' representing the status of the row. When written, this object is used to add or delete entry. Setting to 'enabled' will add a new entry, setting to 'disabled' will delete the entry.rw
Enumeration
.1.3.6.1.4.1.300.200.2.39.1.4
dlcLMIConditioningGroup
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.2.41
dlcLMIConfiguration
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.2.41.1
dlcLMIEnableThis object specifies whether to enable or disable LMI Conditioning.rw
Enumeration
.1.3.6.1.4.1.300.200.2.41.1.1
dlcMaintenanceDLCIThis objects specifies the status of the LMI Spoofing.rw
INTEGER
.1.3.6.1.4.1.300.200.2.41.1.2
dlcManagementDLCIThis objects specifies the number of management DLCI between 16 and 991 inclusive. Must not be the same as maintenance DLCI. Default is 989.rw
INTEGER
.1.3.6.1.4.1.300.200.2.41.1.3
dlcManagementDLCIEnableThis object specifies whether to enable or disable Management DLCI.rw
Enumeration
.1.3.6.1.4.1.300.200.2.41.1.4
dlcSpoofingProtocolTypeThis objects configures which LMI message type to 'spoof', in the event that spoofing is activated. The possible choices are FRF 1.0 (Frame Relay Forum's early LMI adaptation), Annex A (ITU Q.933, annex A), and Annex D (ANSI T1.617, annex D). Default is Annex D.rw
Enumeration
.1.3.6.1.4.1.300.200.2.41.1.5
dlcDTESpoofingEnableIf the value of this object is 'enabled', LMI spoofing to the DTE port is done automatically.rw
Enumeration
.1.3.6.1.4.1.300.200.2.41.1.6
dlcNetSpoofingEnableIf the value of this object is 'enabled', LMI spoofing to the Network port is done automatically.rw
Enumeration
.1.3.6.1.4.1.300.200.2.41.1.7
dlcLinkIntegrityVerificationPollingTimerThis object is the interval in seconds between Link Integrity Verification Messages. This is known as T391 in the standards. Possible values are 5 to 30 seconds in increments of 5. Default is 10 seconds.rw
INTEGER
.1.3.6.1.4.1.300.200.2.41.1.8
dlcFullStatusPollingCounterThis value corresponds to N391 in the ITU and ANSI standards. It is the number of polling cycles of the type before the unit generates the full status request. Possible values are 1 to 255. Default is 10.rw
INTEGER
.1.3.6.1.4.1.300.200.2.41.1.9
dlcLMIErrorEventThis object configures the parameter which sets the number of errors that can occur on the LMI link in LMI Error Monitored Events before reporting an interface down. Applies to the DTE and Network ports. This is used in the same manner as the N392 parameter (N2) in the standards. Possible values are 1 to 10. Default is 1.rw
INTEGER
.1.3.6.1.4.1.300.200.2.41.1.10
dlcLMIErrorMonitorEventThis object configures parameter which sets the number of events that are used with the LMI Error Event to define the error ratio that is used to report when the LMI link is down. Applies to the DTE and Network ports. This value is used in the same manner as the N393 parameter (N3) in the standards.rw
INTEGER
.1.3.6.1.4.1.300.200.2.41.1.11
dlcLMIErrorFreeEventThis object configures the parameter which sets the number of error-free messages that must be received in LMI Error Free Monitored Events prior to declaring an interface is up. Applies to the DTE and Network ports. For network spoofing, this is the number of error-free events that will cause the DSU to believe the network is back up and runnig, and the DSU will stop spoofing. This is used in the same manner as the N392 parameter (N2) in the standards. Possible values are 1 to 10. Default is 1.rw
INTEGER
.1.3.6.1.4.1.300.200.2.41.1.12
dlcLMIErrorFreeMonitorEventThis object configures parameter which sets the number of events that are used with the LMI Error Free Event to define the error ratio that is used to report that the LMI link is up. Applies to the DTE and Network ports. This is used in the same manner as the N393 parameter (N3) in the standards.rw
INTEGER
.1.3.6.1.4.1.300.200.2.41.1.13
dlcDTEResponseTimerThis object configures the parameter which sets the number of seconds between the sending of a status enquiry message and the receipt of a response. Applies to the DTE port. This value is similar in nature to the T392 (T2) parameter in the standards. Possible values are 5 to 30 in increments of 5. Default is 15.rw
INTEGER
.1.3.6.1.4.1.300.200.2.41.1.14
dlcLMIUnitLocationThis object configures where the unit is located so that LMI spoofing could be done properly. If 'cpe' is selected, it means the unit is located in Customer Premise. If 'co' is selected, the unit is in Central Office.rw
Enumeration
.1.3.6.1.4.1.300.200.2.41.1.15
dlcLMIStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.2.41.2
dlcSpoofingStatusThis object configures automatic LMI spoofing to the router. 'True' means LMI spoofing will occur automatically, 'False' means it's disabled.ro
Enumeration
.1.3.6.1.4.1.300.200.2.41.2.1
dlcDTEInterfaceLMIStatusThis object indicates the LMI status of DTE interface.ro
Enumeration
.1.3.6.1.4.1.300.200.2.41.2.2
dlcNetInterfaceLMIStatusThis object indicates the LMI status of Net interface.ro
Enumeration
.1.3.6.1.4.1.300.200.2.41.2.3
dlcInbandDtePortThis object configures which DTE port has inband management.rw
Enumeration
.1.3.6.1.4.1.300.200.2.42
dlcUnitStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.3
dlcUnitCurrentStatusWhat's going on in this unit?ro
UnitStatusItem
.1.3.6.1.4.1.300.200.3.1
dlcUnitErrorFreeSecondsRepresents the percent of error free seconds over the last 24 hours. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is encoded as 942.ro
Gauge
.1.3.6.1.4.1.300.200.3.2
dlcUnitLastSelfTestResultThe result of the last self test. unitLastSelfTest is a bitmap ... the sum of: 0 Selftest passed 1 ROM checksum failure 2 RAM test failure 4 EEPROM CRC failure 8 DTE test failure 16 Pattern loss during test 32 FLASH checksum failure 64 reserved 128 reserved 256 reserved 512 reserved A result of 0 means no errors occurred.ro
INTEGER ( 0..1023 )
.1.3.6.1.4.1.300.200.3.3
dlcUnitPortStatusTableA table of all port-related status
SEQUENCE OF DlcPortStatusEntry
.1.3.6.1.4.1.300.200.3.4
dlcPortStatusEntryAn entry in the port status table.
DlcPortStatusEntry
.1.3.6.1.4.1.300.200.3.4.1
dlcPortStatusIdIdentifies which port (NET, AUX, Data DTE, or whatever) this status entry is describing.ro
PortId
.1.3.6.1.4.1.300.200.3.4.1.1
dlcPortStatusGives the actual status value for to this port.ro
PortStatusItem
.1.3.6.1.4.1.300.200.3.4.1.2
dlcPortStatusNetRxBwUtilizationRepresents the percent of net receive bandwidth utilization over the last 60 seconds. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is encoded as 942.ro
Gauge
.1.3.6.1.4.1.300.200.3.4.1.3
dlcPortStatusNetTxBwUtilizationRepresents the percent of net receive bandwidth utilization over the last 60 seconds. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is encoded as 942.ro
Gauge
.1.3.6.1.4.1.300.200.3.4.1.4
dlcUnitAlarmTableA table of all currently-raised alarms
SEQUENCE OF DlcAlarmEntry
.1.3.6.1.4.1.300.200.3.5
dlcAlarmEntryAn entry in the alarm table.
DlcAlarmEntry
.1.3.6.1.4.1.300.200.3.5.1
dlcAlarmPortIdentifies which port (NET, AUX, Data DTE, or whatever) this alarm relates to.ro
PortId
.1.3.6.1.4.1.300.200.3.5.1.1
dlcAlarmTypeIdentifies an alarm that's currently outstanding against this port.ro
AlarmType
.1.3.6.1.4.1.300.200.3.5.1.2
dlcUnitErrorSecondsRatioRepresents the percent of error seconds over the last 24 hours. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is encoded as 942.ro
Gauge
.1.3.6.1.4.1.300.200.3.6
dlcUnitSeverelyErroredSecondsRatioRepresents the percent of severely errored seconds over the last 24 hours. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is encoded as 942.ro
Gauge
.1.3.6.1.4.1.300.200.3.7
dlcUnitBackgroundBlockErrorRatioRepresents the percent of background block errors over the last 24 hours. The number is multiplied by 10 and rounded to the nearest integer. For example, 94.2% is encoded as 942.ro
Gauge
.1.3.6.1.4.1.300.200.3.8
dlcUnitUserArchive
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.4
dlcUnitUserArchiveValidTableA table of all port-related status
SEQUENCE OF DlcUserArchiveValidEntry
.1.3.6.1.4.1.300.200.4.1
dlcUserArchiveValidEntryAn entry in the user archive valid-intervals table.
DlcUserArchiveValidEntry
.1.3.6.1.4.1.300.200.4.1.1
dlcValidPortIdIdentifies which port (`net' or `otherNet') this entry is describing.ro
PortId
.1.3.6.1.4.1.300.200.4.1.1.1
dlcValidIntervalsThe number of valid intervals in the user's error register database for this port. Writing a 0 to this variable will clear the entire archive for this port. Writing any other value is a no-op.rw
INTEGER ( 1..96 )
.1.3.6.1.4.1.300.200.4.1.1.2
dlcUnitUserLifetimeTableA table of the lifetime error counts, per-port.
SEQUENCE OF DlcUserLifetimeEntry
.1.3.6.1.4.1.300.200.4.2
dlcUserLifetimeEntryAn entry in the user archive lifetime-totals table.
DlcUserLifetimeEntry
.1.3.6.1.4.1.300.200.4.2.1
dlcLifetimePortIdIdentifies which port (`net' or `otherNet') this entry relates to.ro
PortId
.1.3.6.1.4.1.300.200.4.2.1.1
dlcLifetimeESAn ongoing count of Errored Seconds detected on this network port. Can be read and written (to zero).rw
Gauge
.1.3.6.1.4.1.300.200.4.2.1.2
dlcLifetimeUASAn ongoing count of Unavailable Seconds detected on this network port. Can be read and written (to zero).rw
Gauge
.1.3.6.1.4.1.300.200.4.2.1.3
dlcLifetimeCrcErrorsAn ongoing count of the CRC errors detected on this network port. Can be read and written (to zero).rw
Gauge
.1.3.6.1.4.1.300.200.4.2.1.4
dlcLifetimeBpvErrorsAn ongoing count of the Code Violation errors detected on this network port. Can be read and written (to zero).rw
Gauge
.1.3.6.1.4.1.300.200.4.2.1.5
dlcLifetimeOofErrorsFor an ESF T1 port, an ongoing count of Out-Of-Frame errors. For a D4 T1 port, an ongoing count of Framing Errors. Available only for the network port. Can be read and written (to zero).rw
Gauge
.1.3.6.1.4.1.300.200.4.2.1.6
dlcLifetimeIbCrcErrorsAn ongoing count of the FCS errors detected on this network port.rw
Gauge
.1.3.6.1.4.1.300.200.4.2.1.7
dlcUnitUserCurrentTableA table of all the current interval error counts, per-port.
SEQUENCE OF DlcUserCurrentEntry
.1.3.6.1.4.1.300.200.4.3
dlcUserCurrentEntryAn entry in the user archive current interval table.
DlcUserCurrentEntry
.1.3.6.1.4.1.300.200.4.3.1
dlcCurrentPortIdIdentifies which port (`net' or `otherNet') this entry relates to.ro
PortId
.1.3.6.1.4.1.300.200.4.3.1.1
dlcCurrentESErrored seconds in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.3.1.2
dlcCurrentUASUnavailable seconds in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.3.1.3
dlcCurrentCrcErrorsCRC Errors in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.3.1.4
dlcCurrentBpvErrorsCode Violation Errors in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.3.1.5
dlcCurrentOofErrorsOOF or Framing Errors in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.3.1.6
dlcCurrentTimeElapsedThe number of seconds that have elapsed since the beginning of the current error-measurement period. Available only for the network port.ro
INTEGER
.1.3.6.1.4.1.300.200.4.3.1.7
dlcCurrentIbCrcErrorsFCS Errors in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.3.1.8
dlcUnitUserArchiveTableA table of all the archive intervals' error counts, per-port.
SEQUENCE OF DlcUserArchiveEntry
.1.3.6.1.4.1.300.200.4.4
dlcUserArchiveEntryAn entry in the user archive table.
DlcUserArchiveEntry
.1.3.6.1.4.1.300.200.4.4.1
dlcArchivePortIdIdentifies which port (`net' or `otherNet') this entry relates to.ro
PortId
.1.3.6.1.4.1.300.200.4.4.1.1
dlcArchiveIntervalIdentifies which interval this secondaryArchiveEntry describes. 1 indicates the most-recent interval.ro
INTEGER ( 1..96 )
.1.3.6.1.4.1.300.200.4.4.1.2
dlcArchiveESErrored seconds in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.4.1.3
dlcArchiveUASUnavailable seconds in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.4.1.4
dlcArchiveCrcErrorsCRC Errors in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.4.1.5
dlcArchiveBpvErrorsCode Violation Errors in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.4.1.6
dlcArchiveOofErrorsOOF or Framing Errors in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.4.1.7
dlcArchiveIbCrcErrorsFCS Errors in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.4.1.8
dlcArchiveNetRxBwUtilizationNet Rx Bandwidth Utilization in the interval.ro
Gauge
.1.3.6.1.4.1.300.200.4.4.1.9
dlcArchiveNetRxPacketsNet Rx Packets in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.4.1.10
dlcArchiveNetTxBwUtilizationNet Tx Bandwidth Utilization in the interval.ro
Gauge
.1.3.6.1.4.1.300.200.4.4.1.11
dlcArchiveNetTxPacketsNet Tx Packets in the interval.ro
Counter
.1.3.6.1.4.1.300.200.4.4.1.12
dlcUnitTest
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.5
dlcUnitTestTableA table containing all currently active tests. The initial release of the product's firmware does not include multiple tests. However, a later version will allow a number of tests to be active at a time. This MIB object structure allows any number of tests to be running at any time. Upon receiving a SET request, the unit compares this table with the list of currently active tests and terminates or initiates any tests as required. However, this does not apply to Link Based Test. dlcUnitConfigLinkTest group contains objects to configure and start Link Based Test. This table only contains the statistics for Link Based Test.
SEQUENCE OF DlcUnitTestEntry
.1.3.6.1.4.1.300.200.5.1
dlcUnitTestEntryAn entry in the network configuration table.
DlcUnitTestEntry
.1.3.6.1.4.1.300.200.5.1.1
dlcUnitTestPortIdIdentifies a port that a test might be running on. By convention, Self Test and all full-bandwidth tests (loopbacks, patterns, etc.) are assigned to the netPort. For E1 unit, if it is in unstructured mode, only full-bandwidth tests can be performed.ro
PortId
.1.3.6.1.4.1.300.200.5.1.1.1
dlcUnitTestTypeSays what test is running on this port. Note that the following test nomenclature is equivalent: SNMP Terminal UI Front Panel 1in8 1:7 1:7 3in24 3:24 3.24 1in1 1:1 1:1 AllOne All 1 1's AllZero All 0 0's 1in3 1:2 1:2 1in5 1:4 1:4 The SNMP test identifiers use the names on the left. The terminal User Interface uses the names in the middle column, and the unit's front panel uses the names in the right column.rw
TestType
.1.3.6.1.4.1.300.200.5.1.1.2
dlcUnitTestPatternStatusThe current state of the Pattern Test module.ro
Enumeration
.1.3.6.1.4.1.300.200.5.1.1.3
dlcUnitTestPatternErrorsAn ongoing count of errors detected by the Pattern Generator/Detector. Can be read and written (to zero).rw
Gauge
.1.3.6.1.4.1.300.200.5.1.1.4
dlcLinkTestSentPacketsNumber of sent packets for the currently running link based test.ro
Gauge
.1.3.6.1.4.1.300.200.5.1.1.5
dlcLinkTestReceivedPacketsNumber of good received packets for the currently running link based test.ro
Gauge
.1.3.6.1.4.1.300.200.5.1.1.6
dlcLinkTestErroredPacketsNumber of errored received packets for the currently running link based test.ro
Gauge
.1.3.6.1.4.1.300.200.5.1.1.7
dlcLinkTestMissingPacketsNumber of missing packets for the currently running link based test.ro
Gauge
.1.3.6.1.4.1.300.200.5.1.1.8
dlcLinkTestAverageRoundTripAverage round trip time in milli seconds for the currently running link based test.ro
Gauge
.1.3.6.1.4.1.300.200.5.1.1.9
dlcLinkTestMaximumRoundTripMaximum round trip time in milli seconds for the currently running link based test.ro
Gauge
.1.3.6.1.4.1.300.200.5.1.1.10
dlcUnitDelayMonitorStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.300.200.6
dlcDelayMonitorStatusTableTable of Delay Monitor status.
SEQUENCE OF DlcDelayMonitorStatusEntry
.1.3.6.1.4.1.300.200.6.1
dlcDelayMonitorStatusEntryAn entry in the network configuration table.
DlcDelayMonitorStatusEntry
.1.3.6.1.4.1.300.200.6.1.1
dlcDelayMonitorStatusIndexUniquely identifies which Delay Monitor test in the configuration table.ro
INTEGER ( 1..4 )
.1.3.6.1.4.1.300.200.6.1.1.1
dlcDelayMonitorSentPacketsNumber of sent packets for the currently running delay monitor test.ro
Gauge
.1.3.6.1.4.1.300.200.6.1.1.2
dlcDelayMonitorReceivedPacketsNumber of good received packets for the currently running delay monitor test.ro
Gauge
.1.3.6.1.4.1.300.200.6.1.1.3
dlcDelayMonitorErroredPacketsNumber of errored received packets for the currently running delay monitor test.ro
Gauge
.1.3.6.1.4.1.300.200.6.1.1.4
dlcDelayMonitorMissingPacketsNumber of missing packets for the currently running delay monitor test.ro
Gauge
.1.3.6.1.4.1.300.200.6.1.1.5
dlcDelayMonitorAverageRoundTripAverage round trip time in milli seconds for the currently running delay monitor test.ro
Gauge
.1.3.6.1.4.1.300.200.6.1.1.6
dlcDelayMonitorMaximumRoundTripMaximum round trip time in milli seconds for the currently running delay monitor test.ro
Gauge
.1.3.6.1.4.1.300.200.6.1.1.7
dlcUtilizationTableTable for lifetime Utilization statistics.
SEQUENCE OF DlcUtilTableEntry
.1.3.6.1.4.1.300.200.7
dlcUtilTableEntryAn entry for the utilization table.
DlcUtilTableEntry
.1.3.6.1.4.1.300.200.7.1
dlcUtilDLCINumberIdentifies the DLCI number of the utilization statistics of this entry/row.ro
INTEGER
.1.3.6.1.4.1.300.200.7.1.1
dlcUtilEncodedValueThis object represents the value of the whole row of the table. The intent of object is to increase the efficiency of retrieving the table. For each object value in this table, which are all of Counter type, it will be represented with 4 bytes of data.ro
OCTET STRING
.1.3.6.1.4.1.300.200.7.1.2
dlcUtilTimestampIdentifies timestamp when this entry is last updated.ro
Counter
.1.3.6.1.4.1.300.200.7.1.3
dlcUtilLessThan20The number of times utilization is less than 20% of Committed Information Rate (CIR).ro
Counter
.1.3.6.1.4.1.300.200.7.1.4
dlcUtil20-40The number of times utilization is between 20% and 40% of Committed Information Rate (CIR).ro
Counter
.1.3.6.1.4.1.300.200.7.1.5
dlcUtil40-60The number of times utilization is between 40% and 60% of Committed Information Rate (CIR).ro
Counter
.1.3.6.1.4.1.300.200.7.1.6
dlcUtil60-80The number of times utilization is between 60% and 80% of Committed Information Rate (CIR).ro
Counter
.1.3.6.1.4.1.300.200.7.1.7
dlcUtil80-100The number of times utilization is between 80% and 100% of Committed Information Rate (CIR).ro
Counter
.1.3.6.1.4.1.300.200.7.1.8
dlcUtilMoreThan100The number of times utilization is more than 100% of Committed Information Rate (CIR).ro
Counter
.1.3.6.1.4.1.300.200.7.1.9
DL-NEW-DSX1-MIB - SNMP MIB Reference | MIBs Explorer