CBS-VAPGROUP-MIB
The CBS-VAPGROUP-MIB module enables SNMP-based monitoring and configuration of Virtual Access Point (VAP) entities and their aggregation groups within Extreme Networks XOS 9.5 firmware. It provides granular visibility into VAP operational states, group membership parameters, and associated traffic statistics for wireless network management.
Imported Objects
Objects
30 total| Object Name |
|---|
cbsVapGroups OBJECT IDENTIFIER .1.3.6.1.4.1.6848.2.4 |
cbsVapGroupTable SEQUENCE OF CbsVapGroupEntry .1.3.6.1.4.1.6848.2.4.1 |
cbsVapGroupEntry CbsVapGroupEntry .1.3.6.1.4.1.6848.2.4.1.1 |
cbsVgVapGroupIDro Integer32 .1.3.6.1.4.1.6848.2.4.1.1.1 |
cbsVgVapGroupNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6848.2.4.1.1.2 |
cbsVgLoadPriorityro Integer32 .1.3.6.1.4.1.6848.2.4.1.1.3 |
cbsVgPreempPriorityro Integer32 .1.3.6.1.4.1.6848.2.4.1.1.4 |
cbsVgApmListro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6848.2.4.1.1.5 |
cbsVgVapCountro Integer32 .1.3.6.1.4.1.6848.2.4.1.1.6 |
cbsVgMaxLoadCountro Integer32 .1.3.6.1.4.1.6848.2.4.1.1.7 |
cbsVgLBListro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6848.2.4.1.1.8 |
cbsVgBackUpModero Enumeration .1.3.6.1.4.1.6848.2.4.1.1.9 |
cbsVgIpForwardro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.6848.2.4.1.1.10 |
cbsVgRpFilterro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.6848.2.4.1.1.11 |
cbsVgLogMartiansro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.6848.2.4.1.1.12 |
cbsVgReloadTimerro Integer32 .1.3.6.1.4.1.6848.2.4.1.1.13 |
cbsVgRemoteBoxBackuproobsolete TruthValue (SNMPv2-TC) .1.3.6.1.4.1.6848.2.4.1.1.14 |
cbsVgDelayFlowro Integer32 .1.3.6.1.4.1.6848.2.4.1.1.15 |
cbsVgIpv6Forwardro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.6848.2.4.1.1.16 |
cbsVapMappingTable SEQUENCE OF CbsVapMappingEntry .1.3.6.1.4.1.6848.2.4.2 |
cbsVapMappingEntry CbsVapMappingEntry .1.3.6.1.4.1.6848.2.4.2.1 |
cbsVmVapGroupIDro Integer32 .1.3.6.1.4.1.6848.2.4.2.1.1 |
cbsVmVapGroupNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6848.2.4.2.1.2 |
cbsVmVapNamero DisplayString (SNMPv2-TC) .1.3.6.1.4.1.6848.2.4.2.1.3 |
cbsVmVapIndexro Integer32 .1.3.6.1.4.1.6848.2.4.2.1.4 |
cbsVmVapStatusro ModuleState .1.3.6.1.4.1.6848.2.4.2.1.5 |
cbsVmSlotNumberro Integer32 .1.3.6.1.4.1.6848.2.4.2.1.6 |
cbsVapGroupsMIB MODULE-IDENTITY .1.3.6.1.4.1.6848.3.4 |
cbsVapGroupsTraps OBJECT IDENTIFIER .1.3.6.1.4.1.6848.4.3 |
cbsVapStatusChanged NOTIFICATION-TYPE .1.3.6.1.4.1.6848.4.3.1 |
CBS-VAPGROUP-MIB Technical Reference Overview
The CBS-VAPGROUP-MIB SNMP MIB module published by Crossbeam defines 30 managed OID objects, including 22 scalar/column metrics, 2 SNMP tables, and 1 trap/notification events anchored at base OID .1.3.6.1.4.1.6848.3.4. Key tabular structures include cbsVapGroupTable, cbsVapMappingTable. Monitored SNMP traps/notifications include cbsVapStatusChanged.
Key OID Definitions in CBS-VAPGROUP-MIB
.1.3.6.1.4.1.6848.3.4XOS, Release 9.5: This MIB module defines the objects related to VAPs and VAP groups.
.1.3.6.1.4.1.6848.2.4.1This table contains information about the VAP groups.
.1.3.6.1.4.1.6848.2.4.2This table contains information about how the individual VAPs are mapped to hardware modules.
.1.3.6.1.4.1.6848.4.3.1The VAP status for the given VAP changed.
.1.3.6.1.4.1.6848.2.4.1.1An entry in the VAP group table.
.1.3.6.1.4.1.6848.2.4.2.1An entry in the vap mapping table.
.1.3.6.1.4.1.6848.2.4.1.1.5The APMs that are potentially assigned to support this VAP group.
.1.3.6.1.4.1.6848.2.4.1.1.9Specifies how to perform a backup in case an APM fails. None - no backup Pair - VAPs are paired to provide backup functionality Group - all VAPs in the group back up each other.
.1.3.6.1.4.1.6848.2.4.1.1.15Specifies the delay time, in seconds, after the VAP has come up before starting to load balance traffic to this VAP.
.1.3.6.1.4.1.6848.2.4.1.1.10Specifies if IP forwarding is enabled or not.
.1.3.6.1.4.1.6848.2.4.1.1.16Specifies if IPv6 forwarding is enabled or not.
.1.3.6.1.4.1.6848.2.4.1.1.8The list of VAPs to be load balanced.
.1.3.6.1.4.1.6848.2.4.1.1.3Defines relative priority while loading VAPs to hardware modules.
.1.3.6.1.4.1.6848.2.4.1.1.12Specifies if log martians is enabled or not.
.1.3.6.1.4.1.6848.2.4.1.1.7The maximum number of VAPs in this group.
.1.3.6.1.4.1.6848.2.4.1.1.4If this VAP group requires additional APMs to load its VAPs, this priority is used to determine if APMs can be taken from another group. If the preemption priority for this group is higher than the load priority for a currently running VAP, that VAP is thrown out and this VAP is loaded instead. A zero value sets the lowest priority level.
.1.3.6.1.4.1.6848.2.4.1.1.13Specifies the timeout for reloading this VAP group.
.1.3.6.1.4.1.6848.2.4.1.1.14Specifies if failover of this VAP group to a remote system is enabled or not.
.1.3.6.1.4.1.6848.2.4.1.1.11Specifies if RP filter is enabled or not.
.1.3.6.1.4.1.6848.2.4.1.1.6The number of VAPs to load in this group.
.1.3.6.1.4.1.6848.2.4.1.1.1The unique Group ID for the VAP group.
.1.3.6.1.4.1.6848.2.4.1.1.2The VAP group name
.1.3.6.1.4.1.6848.2.4.2.1.6The hardware module ID (slot number) that this VAP is currently mapped to.
.1.3.6.1.4.1.6848.2.4.2.1.1The VAP group ID.
More MIBs from Crossbeam
Browse all CrossbeamMIBs →The CBS-HARDWARE-MIB facilitates SNMP-based monitoring and identification of physical hardware components, environmental sensors, and system status indicators for Crossbeam Systems appliances. It provides standardized access to device inventory, interface states, and hardware health metrics required for infrastructure management and fault isolation.
SNMP MIB module
SNMP MIB module
The CROSSBEAM-SYSTEMS-MIB module enables monitoring of Crossbeam Systems hardware appliances by exposing Product IDs (ProdectIDs) to distinguish specific device models and firmware revisions within the network management infrastructure.