CABH-IETF-CTP-MIB
The CABH-IETF-CTP-MIB provides SNMP-managed diagnostic controls for CableHome Test Portal (CTP) implementations, enabling the configuration and monitoring of remote cable modem connectivity tests and link quality metrics. This module facilitates the execution of specific test sessions and the retrieval of resulting performance data to validate last-mile cable network integrity.
Imported Objects
Objects
45 total| Object Name |
|---|
cabhCtpMib MODULE-IDENTITY .1.3.6.1.2.1.1 |
cabhCtpObjects OBJECT IDENTIFIER .1.3.6.1.2.1.1.1 |
cabhCtpBase OBJECT IDENTIFIER .1.3.6.1.2.1.1.1.1 |
cabhCtpSetToFactoryrw TruthValue (SNMPv2-TC) .1.3.6.1.2.1.1.1.1.1 |
cabhCtpLastSetToFactoryro TimeStamp (SNMPv2-TC) .1.3.6.1.2.1.1.1.1.2 |
cabhCtpConnSpeed OBJECT IDENTIFIER .1.3.6.1.2.1.1.1.2 |
cabhCtpConnSrcIpTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.2.1.1.1.2.1 |
cabhCtpConnSrcIprw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.2.1.1.1.2.2 |
cabhCtpConnDestIpTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.2.1.1.1.2.3 |
cabhCtpConnDestIprw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.2.1.1.1.2.4 |
cabhCtpConnProtorw Enumeration .1.3.6.1.2.1.1.1.2.5 |
cabhCtpConnNumPktsrw INTEGER .1.3.6.1.2.1.1.1.2.6 |
cabhCtpConnPktSizerw INTEGER .1.3.6.1.2.1.1.1.2.7 |
cabhCtpConnTimeOutrw INTEGER .1.3.6.1.2.1.1.1.2.8 |
cabhCtpConnControlrw Enumeration .1.3.6.1.2.1.1.1.2.9 |
cabhCtpConnStatusro Enumeration .1.3.6.1.2.1.1.1.2.10 |
cabhCtpConnPktsSentro INTEGER .1.3.6.1.2.1.1.1.2.11 |
cabhCtpConnPktsRecvro INTEGER .1.3.6.1.2.1.1.1.2.12 |
cabhCtpConnRTTro INTEGER .1.3.6.1.2.1.1.1.2.13 |
cabhCtpConnThroughputro INTEGER .1.3.6.1.2.1.1.1.2.14 |
cabhCtpPing OBJECT IDENTIFIER .1.3.6.1.2.1.1.1.3 |
cabhCtpPingSrcIpTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.2.1.1.1.3.1 |
cabhCtpPingSrcIprw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.2.1.1.1.3.2 |
cabhCtpPingDestIpTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.2.1.1.1.3.3 |
cabhCtpPingDestIprw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.2.1.1.1.3.4 |
cabhCtpPingNumPktsrw INTEGER .1.3.6.1.2.1.1.1.3.5 |
cabhCtpPingPktSizerw INTEGER .1.3.6.1.2.1.1.1.3.6 |
cabhCtpPingTimeBetweenrw INTEGER .1.3.6.1.2.1.1.1.3.7 |
cabhCtpPingTimeOutrw INTEGER .1.3.6.1.2.1.1.1.3.8 |
cabhCtpPingControlrw Enumeration .1.3.6.1.2.1.1.1.3.9 |
cabhCtpPingStatusro Enumeration .1.3.6.1.2.1.1.1.3.10 |
cabhCtpPingNumSentro INTEGER .1.3.6.1.2.1.1.1.3.11 |
cabhCtpPingNumRecvro INTEGER .1.3.6.1.2.1.1.1.3.12 |
cabhCtpPingAvgRTTro INTEGER .1.3.6.1.2.1.1.1.3.13 |
cabhCtpPingMaxRTTro INTEGER .1.3.6.1.2.1.1.1.3.14 |
cabhCtpPingMinRTTro INTEGER .1.3.6.1.2.1.1.1.3.15 |
cabhCtpPingNumIcmpErrorro INTEGER .1.3.6.1.2.1.1.1.3.16 |
cabhCtpPingIcmpErrorro INTEGER .1.3.6.1.2.1.1.1.3.17 |
cabhCtpNotification OBJECT IDENTIFIER .1.3.6.1.2.1.1.2 |
cabhCtpNotifications OBJECT IDENTIFIER .1.3.6.1.2.1.1.2.0 |
cabhCtpConformance OBJECT IDENTIFIER .1.3.6.1.2.1.1.3 |
cabhCtpCompliances OBJECT IDENTIFIER .1.3.6.1.2.1.1.3.1 |
cabhCtpBasicCompliance Unknown .1.3.6.1.2.1.1.3.1.3 |
cabhCtpGroups OBJECT IDENTIFIER .1.3.6.1.2.1.1.3.2 |
cabhCtpGroup Unknown .1.3.6.1.2.1.1.3.2.1 |
CABH-IETF-CTP-MIB Technical Reference Overview
The CABH-IETF-CTP-MIB SNMP MIB module published by Default defines 45 managed OID objects, including 35 scalar/column metrics, 0 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.2.1.1.
Key OID Definitions in CABH-IETF-CTP-MIB
.1.3.6.1.2.1.1This MIB module defines the diagnostic controls offered by the CableHome Test Portal (CTP). Copyright (C) The Internet Society (2003). This version of this MIB module is part of RFC xxxx; see the RFC itself for full legal notices.
.1.3.6.1.2.1.1.3.1.3The compliance statement for devices that implement Portal Service feature.
.1.3.6.1.2.1.1.1.2.9The control for the Connection Speed Tool. Setting this object to start(1) causes the Connection Speed Tool to execute. Setting this object to abort(2) causes the Connection Speed Tool to stop running. This parameter should only be set via SNMP.
.1.3.6.1.2.1.1.1.2.4The IP Address used as the destination address for the Connection Speed Test. The type of this address is specified by cabhCtpConnDestIpType
.1.3.6.1.2.1.1.1.2.3The IP Address Type for the CTP Connection Speed Tool destination address.
.1.3.6.1.2.1.1.1.2.6The number of packets the CTP is to send when triggered to execute the Connection Speed Tool.
.1.3.6.1.2.1.1.1.2.7The size of the test frames.
.1.3.6.1.2.1.1.1.2.12The number of packets the CTP received after it executed the Connection Speed Tool.
.1.3.6.1.2.1.1.1.2.11The number of packets the CTP sent after it was triggered to execute the Connection Speed Tool.
.1.3.6.1.2.1.1.1.2.5The protocol used in the Connection Speed Test. TCP testing is optional.
.1.3.6.1.2.1.1.1.2.13The resulting round trip time for the set of packets sent to and received from the target LAN IP Device.
.1.3.6.1.2.1.1.1.2.2The IP Address used as the source address for the Connection Speed Test. The type of this address is specified by cabhCtpConnSrcIpType. The default value is the value of cabhCdpServerRouter (192.168.0.1).
.1.3.6.1.2.1.1.1.2.1The IP Address type used as the source address for the Connection Speed Test.
.1.3.6.1.2.1.1.1.2.10The status of the Connection Speed Tool.
.1.3.6.1.2.1.1.1.2.14The average round-trip throughput measured in kilobits per second.
.1.3.6.1.2.1.1.1.2.8The timeout value for the response. A value of zero indicates no time out and can be used for TCP only.
.1.3.6.1.2.1.1.3.2.1Group of objects for CableHome CTP MIB.
.1.3.6.1.2.1.1.1.1.2The value of sysUpTime when cabhCtpSetToFactory was last set to true. Zero if never reset.
.1.3.6.1.2.1.1.1.3.13The resulting average of round trip times for acknowledged packets.
.1.3.6.1.2.1.1.1.3.9The control for the Ping Tool. Setting this object to start(1) causes the Ping Tool to execute. Setting this object to abort(2) causes the Ping Tool to stop running. This parameter should only be set via SNMP.
.1.3.6.1.2.1.1.1.3.4The Destination IP Address used as the destination address for the Ping Test.
.1.3.6.1.2.1.1.1.3.3The IP Address Type for the CTP Ping Tool destination address.
.1.3.6.1.2.1.1.1.3.17The last ICMP error.
.1.3.6.1.2.1.1.1.3.14The resulting maximum of round trip times for acknowledged packets.
More MIBs from Default
Browse all DefaultMIBs →The VMWARE-NSX-MIB enables SNMP-based monitoring and management of VMware NSX-T Data Center virtual network infrastructure, exposing metrics for logical switches, routers, distributed firewalls, and overlay tunnel states. It facilitates the tracking of Layer 2 through Layer 7 service instances, including access control lists, Quality of Service policies, and virtual network topology changes within the software-defined networking environment.
Standard SNMP MIB module defining data structures for 923switch.m.
Standard SNMP MIB module defining data structures for CTATX-MIB.
SNMP MIB module
SNMP MIB module
SNMP MIB module