CABH-CDP-MIB
The CABH-CDP-MIB module enables SNMP-based monitoring of CableHome DHCP Portal (CDP) session states, lease allocations, and database synchronization metrics within the PacketCable/PS database architecture. It facilitates the management of DHCP portal operational parameters and error counters for CableHome network elements.
Imported Objects
Objects
71 total| Object Name |
|---|
cabhCdpMib MODULE-IDENTITY .1.3.6.1.4.1.4491.2.4.4 |
cabhCdpObjects OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.4.4.1 |
cabhCdpBase OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.4.4.1.1 |
cabhCdpSetToFactoryrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.4491.2.4.4.1.1.1 |
cabhCdpLanTransCurCountro Unsigned32 .1.3.6.1.4.1.4491.2.4.4.1.1.2 |
cabhCdpLanTransThresholdrw INTEGER .1.3.6.1.4.1.4491.2.4.4.1.1.3 |
cabhCdpLanTransActionrw Enumeration .1.3.6.1.4.1.4491.2.4.4.1.1.4 |
cabhCdpWanDataIpAddrCountrw INTEGER ( 0..63 ) .1.3.6.1.4.1.4491.2.4.4.1.1.5 |
cabhCdpLastSetToFactoryro TimeStamp (SNMPv2-TC) .1.3.6.1.4.1.4491.2.4.4.1.1.6 |
cabhCdpTimeOffsetSelectionrw Enumeration .1.3.6.1.4.1.4491.2.4.4.1.1.7 |
cabhCdpSnmpSetTimeOffsetrw Integer32 (-43200..46800) -- -12 to +13 hours (seconds) UNITS "seconds" .1.3.6.1.4.1.4491.2.4.4.1.1.8 |
cabhCdpDaylightSavingTimeEnablerw Enumeration .1.3.6.1.4.1.4491.2.4.4.1.1.9 |
cabhCdpAddr OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.4.4.1.2 |
cabhCdpLanAddrTable SEQUENCE OF CabhCdpLanAddrEntry .1.3.6.1.4.1.4491.2.4.4.1.2.1 |
cabhCdpLanAddrEntry CabhCdpLanAddrEntry .1.3.6.1.4.1.4491.2.4.4.1.2.1.1 |
cabhCdpLanAddrIpType InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.2.1.1.1 |
cabhCdpLanAddrIp InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.2.1.1.2 |
cabhCdpLanAddrClientIDrw PhysAddress (SNMPv2-TC) .1.3.6.1.4.1.4491.2.4.4.1.2.1.1.3 |
cabhCdpLanAddrLeaseCreateTimero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.4491.2.4.4.1.2.1.1.4 |
cabhCdpLanAddrLeaseExpireTimero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.4491.2.4.4.1.2.1.1.5 |
cabhCdpLanAddrMethodro Enumeration .1.3.6.1.4.1.4491.2.4.4.1.2.1.1.6 |
cabhCdpLanAddrHostNamero SnmpAdminString .1.3.6.1.4.1.4491.2.4.4.1.2.1.1.7 |
cabhCdpLanAddrRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.4491.2.4.4.1.2.1.1.8 |
cabhCdpWanDataAddrTable SEQUENCE OF CabhCdpWanDataAddrEntry .1.3.6.1.4.1.4491.2.4.4.1.2.2 |
cabhCdpWanDataAddrEntry CabhCdpWanDataAddrEntry .1.3.6.1.4.1.4491.2.4.4.1.2.2.1 |
cabhCdpWanDataAddrIndex INTEGER .1.3.6.1.4.1.4491.2.4.4.1.2.2.1.1 |
cabhCdpWanDataAddrClientIdrw OCTET STRING .1.3.6.1.4.1.4491.2.4.4.1.2.2.1.2 |
cabhCdpWanDataAddrIpTypero InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.2.2.1.3 |
cabhCdpWanDataAddrIpro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.2.2.1.4 |
cabhCdpWanDataAddrRenewalTimerodeprecated Integer32 .1.3.6.1.4.1.4491.2.4.4.1.2.2.1.5 |
cabhCdpWanDataAddrRowStatusrw RowStatus (SNMPv2-TC) .1.3.6.1.4.1.4491.2.4.4.1.2.2.1.6 |
cabhCdpWanDataAddrLeaseCreateTimero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.4491.2.4.4.1.2.2.1.7 |
cabhCdpWanDataAddrLeaseExpireTimero DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.4491.2.4.4.1.2.2.1.8 |
cabhCdpWanDnsServerTable SEQUENCE OF CabhCdpWanDnsServerEntry .1.3.6.1.4.1.4491.2.4.4.1.2.3 |
cabhCdpWanDnsServerEntry CabhCdpWanDnsServerEntry .1.3.6.1.4.1.4491.2.4.4.1.2.3.1 |
cabhCdpWanDnsServerOrder Enumeration .1.3.6.1.4.1.4491.2.4.4.1.2.3.1.1 |
cabhCdpWanDnsServerIpTypero InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.2.3.1.2 |
cabhCdpWanDnsServerIpro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.2.3.1.3 |
cabhCdpServer OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.4.4.1.3 |
cabhCdpLanPoolStartTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.1 |
cabhCdpLanPoolStartrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.2 |
cabhCdpLanPoolEndTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.3 |
cabhCdpLanPoolEndrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.4 |
cabhCdpServerNetworkNumberTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.5 |
cabhCdpServerNetworkNumberrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.6 |
cabhCdpServerSubnetMaskTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.7 |
cabhCdpServerSubnetMaskrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.8 |
cabhCdpServerTimeOffsetrw Integer32 (-86400..86400) -- 0 to 24 hours (in seconds) UNITS "seconds" .1.3.6.1.4.1.4491.2.4.4.1.3.9 |
cabhCdpServerRouterTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.10 |
cabhCdpServerRouterrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.11 |
cabhCdpServerDnsAddressTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.12 |
cabhCdpServerDnsAddressrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.13 |
cabhCdpServerSyslogAddressTyperw InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.14 |
cabhCdpServerSyslogAddressrw InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.15 |
cabhCdpServerDomainNamerw SnmpAdminString .1.3.6.1.4.1.4491.2.4.4.1.3.16 |
cabhCdpServerTTLrw INTEGER .1.3.6.1.4.1.4491.2.4.4.1.3.17 |
cabhCdpServerInterfaceMTUrw Integer32 (0 | 68..4096) .1.3.6.1.4.1.4491.2.4.4.1.3.18 |
cabhCdpServerVendorSpecificrw OCTET STRING .1.3.6.1.4.1.4491.2.4.4.1.3.19 |
cabhCdpServerLeaseTimerw Unsigned32 UNITS "seconds" .1.3.6.1.4.1.4491.2.4.4.1.3.20 |
cabhCdpServerDhcpAddressTypero InetAddressType (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.21 |
cabhCdpServerDhcpAddressro InetAddress (INET-ADDRESS-MIB) .1.3.6.1.4.1.4491.2.4.4.1.3.22 |
cabhCdpServerControlrw Enumeration .1.3.6.1.4.1.4491.2.4.4.1.3.23 |
cabhCdpServerCommitStatusro Enumeration .1.3.6.1.4.1.4491.2.4.4.1.3.24 |
cabhCdpServerUseCableDataNwDnsAddrrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.4491.2.4.4.1.3.25 |
cabhCdpNotification OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.4.4.2 |
cabhCdpNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.4.4.2.0 |
cabhCdpConformance OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.4.4.3 |
cabhCdpCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.4.4.3.1 |
cabhCdpBasicCompliance Unknown .1.3.6.1.4.1.4491.2.4.4.3.1.3 |
cabhCdpGroups OBJECT IDENTIFIER .1.3.6.1.4.1.4491.2.4.4.3.2 |
cabhCdpGroup Unknown .1.3.6.1.4.1.4491.2.4.4.3.2.1 |
CABH-CDP-MIB Technical Reference Overview
The CABH-CDP-MIB SNMP MIB module published by Cable Television Laboratories defines 71 managed OID objects, including 55 scalar/column metrics, 3 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.4491.2.4.4. Key tabular structures include cabhCdpLanAddrTable, cabhCdpWanDataAddrTable, cabhCdpWanDnsServerTable.
Key OID Definitions in CABH-CDP-MIB
.1.3.6.1.4.1.4491.2.4.4This MIB module supplies the basic management objects for the CableHome DHCP Portal (CDP) portion of the PS database.
.1.3.6.1.4.1.4491.2.4.4.1.2.1This table is a list of LAN-Trans realm parameters. This table has one row entry for each allocated LAN-Trans IP address. Each row must have at least a valid cabhCdpLanAddrMethod, a cabhCdpLanAddrIpType, a unique cabhCdpLanAddrIp, and a unique cabhCdpLanAddrClientId value. Static/Manual address assignment: To create a new DHCP address reservation, the NMS creates a row with: an index comprised of a new cabhCdpLanAddrIp and its cabhCdpLanAddrIpType, a new unique cabhCdpLanAddrClientID, (an empty LeaseCreateTime and empty LeaseExpireTime,) and a cabhCdpLanDataAddrRowStatus of createAndGo(4). If the syntax and values of the new row - indicating a reservation - are valid, the PS must set cabhCdpLanAddrMethod to reservationInactive(1) and cabhCdpLanDataAddrRowStatus to active(1). When the PS grants a lease for a reserved IP, it must set the cabhCdpLanAddrMethod object for that row to reservationActive(2). When a lease for a reserved IP expires, the PS must set the corresponding row's cabhCdpLanAddrMethod object to reservationInactive(1). For row entries that represent lease reservations - rows in which the cabhCdpLanAddrMethod object has a value of either reservationInactive(1) or reservationActive(2) - the cabhCdpLanAddrIpType, cabhCdpLanAddrIp, cabhCdpLanAddrClientID, cabhCdpLanAddrMethod, and cabhCdpLanAddrHostName object values must persist across PS reboots. Dynamic address assignment: When the PS grants a lease for a non-reserved IP, it must set the cabhCdpLanAddrMethod object for that row to dynamicActive(4). When a lease for a non-reserved IP expires, the PS must set the corresponding row's cabhCdpLanAddrMethod object to dynamicInactive(3). The PS must create new row entries using cabhCdpLanAddrIp values that are unique to this table. If all cabhCdpLanAddrIp values in the range defined by cabhCdpLanPoolStart and cabhCdpLanPoolEnd are in use in this table, the PS may overwrite the cabhCdpLanAddrClientId of a row that has a cabhCdpLanAddrMethod object with a value of dynamicInactive(3) with a new cabhCdpLanAddrClientId value and use that cabhCdpLanAddrIp as part of a new lease. For row entries that represent active leases - rows in which the cabhCdpLanAddrMethod object has a value of dynamicActive(4) - the cabhCdpLanAddrIpType, cabhCdpLanAddrIp, cabhCdpLanAddrClientID, cabhCdpLanAddrMethod, and cabhCdpLanAddrHostName object values must persist across PS reboots.
.1.3.6.1.4.1.4491.2.4.4.1.2.2This table contains WAN-Data address realm information.
.1.3.6.1.4.1.4491.2.4.4.1.2.3This table contains the IP addresses of cable network and Internet DNS servers, in the order of preference in which the PS's CNP will query them, when it cannot resolve a DNS query using local information. Entries in this table are updated with the information contained in DHCP Option 6, received during both the WAN-Man and WAN-Data IP acquisition processes.
.1.3.6.1.4.1.4491.2.4.4.3.1.3The compliance statement for devices that implement the CableHome Portal Services functionality.
.1.3.6.1.4.1.4491.2.4.4.1.1.9This object allows a manager to configure the PS to adjust the current time of day based on Daylight Saving Time. If the value of this object is enabled(1), the PS adds 3600 seconds and the time offset specified by cabhCdpServerTimeOffsetSelection to the UTC time acquired from the time of day server to create the current time of day during Daylight Saving Time, and adds only the time offset specified by cabhCdpServerTimeOffsetSelection to the UTC time acquired from the time of day server during standard time. The PS is responsible for knowing the date and time of each transition between Daylight Saving Time and standard time. If the value of this object is disabled(2), the PS adds only the time offset specified by cabhCdpServerTimeOffsetSelection to the UTC time acquired from the time of day server.
.1.3.6.1.4.1.4491.2.4.4.3.2.1Group of objects for CableHome CDP MIB.
.1.3.6.1.4.1.4491.2.4.4.1.3.4The end of range for LAN-Trans IP Addresses. The type of this address is specified by cabhCdpLanPoolEndType.
.1.3.6.1.4.1.4491.2.4.4.1.3.3The Address type of the end of range LAN Trans IP Addresses.
.1.3.6.1.4.1.4491.2.4.4.1.3.2The start of range LAN Trans IP Addresses. The type of this address is specified by cabhCdpLanPoolStartType.
.1.3.6.1.4.1.4491.2.4.4.1.3.1The Address type of the start of range LAN Trans IP Addresses.
.1.3.6.1.4.1.4491.2.4.4.1.1.4The action taken when the CDS assigns a LAN-Trans address and the number of LAN-Trans addresses assigned (cabhCdpLanTransCurCount) is greater than the threshold (cabhCdpLanTransThreshold) The actions are as follows: normal - assign a LAN-Trans IP address as would normally occur if the threshold was not exceeded. noAssignment - do not assign a LAN-Trans IP address.
.1.3.6.1.4.1.4491.2.4.4.1.1.2The current number of active leases in the cabhCdpLanAddrTable (the number of row entries in the table that have a cabhCdpLanAddrMethod value of reservationActive(2) or dynamicActive (4)). This count does not include expired leases or reservations not associated with a current lease.
.1.3.6.1.4.1.4491.2.4.4.1.1.3The threshold number of LAN-Trans IP addresses allocated or assigned above which the PS generates an alarm condition. Whenever an attempt is made to allocate a LAN-Trans IP address when cabhCdpLanTransCurCount is greater than or equal to cabhCdpLanTransThreshold, an event is generated. A value of 0 indicates that the CDP sets the threshold at the highest number of addresses in the LAN address pool.
.1.3.6.1.4.1.4491.2.4.4.1.1.6The value of sysUpTime when cabhCdpSetToFactory was last set to true. Zero if never reset.
.1.3.6.1.4.1.4491.2.4.4.1.3.24Indicates the status of committing the current cabhCdpServer mib object values to the running configuration of the CDS (DHCP Server). commitSucceeded - indicates the current cabhCdpServer mib object values are valid and have been successfully committed to the running configuration of the CDS. commitNeeded - indicates that the value of one or more objects in cabhCdpServer mib group have been changed but not yet committed to the running configuration of the CDS. commitFailed - indicates the PS was unable to commit the cabhCdpServer mib object values to the running configuration of the CDS due to conflicts in those values.
.1.3.6.1.4.1.4491.2.4.4.1.3.23The control for the CDS (DHCP Server) configuration. All changes to the cabhCdpServer mib objects are reflected when reading the value of the mib objects; however, those changes are NOT applied to the running configuration of the CDS until they are successfully committed via use of the cabhCdpServerControl object. If changes are made to the cabhCdpServer mib objects which are not yet successfully committed to the CDS, the cabhCdpServerControl object can be used to rollback all changes to the last valid CDS configuration and discard all intermediate changes. restoreConfig - Setting cabhCdpServerControl to this value will cause any changes to the cabhCdpServer objects not yet committed be reset to the values from the current running configuration of the CDS. commitConfig - Setting cabhCdpServerControl to this value will cause the CDS to validate and apply the valid cabhCdpServer mib settings to its running configuration. The cabhCdpServerCommitStatus object will detail the status of this operation.
.1.3.6.1.4.1.4491.2.4.4.1.3.22The value of this MIB object is always the same as the value of the cabhCdpServerRouter object. The type of this address is specified by cabhCdpServerDhcpAddressType. The PS MUST provide the value of this MIB object in the Option 54 (DHCP server identifier) field of DHCP OFFER and ACK messages sent to a LAN IP device.
.1.3.6.1.4.1.4491.2.4.4.1.3.21Type of LAN DHCP server IP address. The IP address of LAN DHCP server is provided by the PS in option 54 of DHCP OFFER or ACK.
.1.3.6.1.4.1.4491.2.4.4.1.3.13The default value of this MIB object is the same as the value of the cabhCdpServerRouter object. The NMS may set the value of this object to a value different than the value of cabhCdpServerRouter (e.g. DNS server in the cable data network) so that a LAN IP Device can direct its DNS queries to a server other than the PS DNS server. The type of this address is specified by cabhCdpServerDnsAddressType. The PS MUST provide the value of this MIB object in the Option 6 (Domain Name Server) of DHCP OFFER and ACK messages sent to a LAN IP Device.
.1.3.6.1.4.1.4491.2.4.4.1.3.12The Type of IP Addresses of the LAN-Trans address realm DNS servers.
.1.3.6.1.4.1.4491.2.4.4.1.3.16The PS MUST provide the value of this MIB object in the Option 15 (Domain Name Option) of the DHCP OFFER and ACK messages sent to the LAN IP Device.
.1.3.6.1.4.1.4491.2.4.4.1.3.18The PS MUST provide the value of this MIB object in the Option 26 (Interface MTU Option) of the DHCP OFFER and ACK messages sent to the LAN IP Device. If the value of this object is 0, the PS must not include this option in its DHCP OFFER or DHCP ACK messages to LAN IP Devices.
.1.3.6.1.4.1.4491.2.4.4.1.3.20The PS MUST provide the value of this MIB object in the Option 51 (IP Address lease time) of the DHCP OFFER and ACK messages sent to the LAN IP Device.
More MIBs from Cable Television Laboratories
Browse all Cable Television LaboratoriesMIBs →The CLAB-WIFI-MIB module provides SNMP management objects for monitoring and configuring Wi-Fi interface parameters on Cable Television Laboratories, Inc. (CableLabs) compliant hardware. It exposes specific metrics for wireless interface status, operational states, and performance counters to facilitate network troubleshooting and configuration management.