Home/Catalog/BRCM-BATTERY-MGMT-MIB

BRCM-BATTERY-MGMT-MIB

AI MIB Summary

The BRCM-BATTERY-MGMT-MIB enables SNMP-based monitoring of battery health parameters, including charge levels, voltage, current, and remaining runtime, specifically on Broadcom-managed hardware platforms. This proprietary module facilitates the tracking of battery status and degradation metrics to support power redundancy management and predictive maintenance.

Broadcom proprietary MIB for management of battery objects.
Main OID:
batteryMgmt.cableDataMgmtMIBObjects.10
44
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

44 total
Object Name
batteryMgmt
MODULE-IDENTITY
.cableDataMgmtMIBObjects.10
batteryMgmtBase
OBJECT IDENTIFIER
.cableDataMgmtMIBObjects.10.1
batteryTable
SEQUENCE OF BatteryEntry
.cableDataMgmtMIBObjects.10.1.1
batteryEntry
BatteryEntry
.cableDataMgmtMIBObjects.10.1.1.1
battIndex
Integer32
.cableDataMgmtMIBObjects.10.1.1.1.1
battCapacityro
Unsigned32 UNITS "milliamp hours"
.cableDataMgmtMIBObjects.10.1.1.1.2
battMaximumVoltagero
Unsigned32 UNITS "millivolts"
.cableDataMgmtMIBObjects.10.1.1.1.3
battMinimumVoltagero
Unsigned32 UNITS "millivolts"
.cableDataMgmtMIBObjects.10.1.1.1.4
battMeasuredVoltagero
Unsigned32 UNITS "millivolts"
.cableDataMgmtMIBObjects.10.1.1.1.5
battIsValidro
TruthValue (SNMPv2-TC)
.cableDataMgmtMIBObjects.10.1.1.1.6
battIsSelectedro
TruthValue (SNMPv2-TC)
.cableDataMgmtMIBObjects.10.1.1.1.7
battEstimatedMinutesRemainingro
PositiveInteger UNITS "minutes"
.cableDataMgmtMIBObjects.10.1.1.1.8
battEstimatedChargeRemainingro
INTEGER
.cableDataMgmtMIBObjects.10.1.1.1.9
battErrorsro
Unsigned32
.cableDataMgmtMIBObjects.10.1.1.1.10
battEpromRevisionro
DisplayString (SNMPv2-TC)
.cableDataMgmtMIBObjects.10.1.1.1.11
battPackSupplierro
DisplayString (SNMPv2-TC)
.cableDataMgmtMIBObjects.10.1.1.1.12
battModelNumberro
DisplayString (SNMPv2-TC)
.cableDataMgmtMIBObjects.10.1.1.1.13
battSerialNumberro
DisplayString (SNMPv2-TC)
.cableDataMgmtMIBObjects.10.1.1.1.14
battCellSupplierro
DisplayString (SNMPv2-TC)
.cableDataMgmtMIBObjects.10.1.1.1.15
battCellCapacityro
DisplayString (SNMPv2-TC)
.cableDataMgmtMIBObjects.10.1.1.1.16
battCellDateCodero
DisplayString (SNMPv2-TC)
.cableDataMgmtMIBObjects.10.1.1.1.17
battPackDateCodero
DisplayString (SNMPv2-TC)
.cableDataMgmtMIBObjects.10.1.1.1.18
batteryCharger
OBJECT IDENTIFIER
.cableDataMgmtMIBObjects.10.2
battChargerMicrocodeVersionro
DisplayString (SNMPv2-TC)
.cableDataMgmtMIBObjects.10.2.1
battChargerMicrocodeBuildTimero
DateAndTime (SNMPv2-TC)
.cableDataMgmtMIBObjects.10.2.2
battChargerInputVoltagero
Unsigned32 UNITS "millivolts"
.cableDataMgmtMIBObjects.10.2.3
battChargerStatero
Enumeration
.cableDataMgmtMIBObjects.10.2.4
battChargerMaximumChargerw
Unsigned32
.cableDataMgmtMIBObjects.10.2.5
battChargerReplaceBatteryThresholdrw
Unsigned32
.cableDataMgmtMIBObjects.10.2.6
battChargerLowChargeThresholdrw
Unsigned32
.cableDataMgmtMIBObjects.10.2.7
batteryPowerMgmt
OBJECT IDENTIFIER
.cableDataMgmtMIBObjects.10.3
batteryPowerMgmtInterfaces
OBJECT IDENTIFIER
.cableDataMgmtMIBObjects.10.3.1
battPowerMgmtCmDelayrw
Integer32 (-1..2147483647) UNITS "seconds"
.cableDataMgmtMIBObjects.10.3.1.1
battPowerMgmtEthernetDelayrw
Integer32 (-1..2147483647) UNITS "seconds"
.cableDataMgmtMIBObjects.10.3.1.2
battPowerMgmtUsbDelayrw
Integer32 (-1..2147483647) UNITS "seconds"
.cableDataMgmtMIBObjects.10.3.1.3
battPowerMgmtWiFiDelayrw
Integer32 (-1..2147483647) UNITS "seconds"
.cableDataMgmtMIBObjects.10.3.1.4
battPowerMgmtBluetoothDelayrw
Integer32 (-1..2147483647) UNITS "seconds"
.cableDataMgmtMIBObjects.10.3.1.5
battPowerMgmtHpnaDelayrw
Integer32 (-1..2147483647) UNITS "seconds"
.cableDataMgmtMIBObjects.10.3.1.6
batteryBcmAlarms
OBJECT IDENTIFIER
.cableDataMgmtMIBObjects.10.4
bcmAlarmLowBatteryCharge
OBJECT IDENTIFIER
.cableDataMgmtMIBObjects.10.4.1
bcmAlarmTempBadChargeSuspended
OBJECT IDENTIFIER
.cableDataMgmtMIBObjects.10.4.2
bcmAlarmTempBadPowerReduced
OBJECT IDENTIFIER
.cableDataMgmtMIBObjects.10.4.3
bcmAlarmBatteryMissing
OBJECT IDENTIFIER
.cableDataMgmtMIBObjects.10.4.4
bcmAlarmTempBadDischargeInhibited
OBJECT IDENTIFIER
.cableDataMgmtMIBObjects.10.4.5

BRCM-BATTERY-MGMT-MIB Technical Reference Overview

The BRCM-BATTERY-MGMT-MIB SNMP MIB module published by Default defines 44 managed OID objects, including 31 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .cableDataMgmtMIBObjects.10. Key tabular structures include batteryTable.

Key OID Definitions in BRCM-BATTERY-MGMT-MIB

batteryMgmtMODULE-IDENTITYnot-accessible
.cableDataMgmtMIBObjects.10

Broadcom proprietary MIB for management of battery objects.

batteryTableSEQUENCEnot-accessible
.cableDataMgmtMIBObjects.10.1.1

A table of batteries present on the system.

battChargerMicrocodeVersionDisplayStringread-only
.cableDataMgmtMIBObjects.10.2.1

The version of the battery charger microcode.

battChargerMicrocodeBuildTimeDateAndTimeread-only
.cableDataMgmtMIBObjects.10.2.2

The build date and time of the battery charger microcode.

battChargerInputVoltageUnsigned32read-only
.cableDataMgmtMIBObjects.10.2.3

The most recently measured input voltage to the battery charger. Typically, if operating on battery power, this value will approach zero. If operating on utility power, this value will approach the value of the power supplied to the device.

battChargerStateINTEGERread-only
.cableDataMgmtMIBObjects.10.2.4

The current state of the battery charger. Note that all states may not be supported on all types of chargers.

battChargerMaximumChargeUnsigned32read-write
.cableDataMgmtMIBObjects.10.2.5

Specifies the level to which the charger should charge the batteries.

battChargerReplaceBatteryThresholdUnsigned32read-write
.cableDataMgmtMIBObjects.10.2.6

Specifies the minimum charge percentage that the battery must be able to reach when charging. If a battery cannot be charged above this percentage, it will be considered bad and battIsValid will transition to false(2).

battChargerLowChargeThresholdUnsigned32read-write
.cableDataMgmtMIBObjects.10.2.7

Specifies the charge percentage at which the bcmAlarmLowBatteryCharge will be raised.

battPowerMgmtCmDelayInteger32read-write
.cableDataMgmtMIBObjects.10.3.1.1

Specifies the number of seconds following transition to battery power before the DOCSIS CM interface will enter power management mode. If set to -1, the interface will never enter power management mode and will remain at full power until utility power is restored or battery charge is depleted.

battPowerMgmtEthernetDelayInteger32read-write
.cableDataMgmtMIBObjects.10.3.1.2

Specifies the number of seconds following transition to battery power before the ethernet interface will enter power management mode. If set to -1, the interface will never enter power management mode and will remain at full power until utility power is restored or battery charge is depleted.

battPowerMgmtUsbDelayInteger32read-write
.cableDataMgmtMIBObjects.10.3.1.3

Specifies the number of seconds following transition to battery power before the USB interface will enter power management mode. If set to -1, the interface will never enter power management mode and will remain at full power until utility power is restored or battery charge is depleted.

battPowerMgmtWiFiDelayInteger32read-write
.cableDataMgmtMIBObjects.10.3.1.4

Specifies the number of seconds following transition to battery power before the WiFi interface will enter power management mode. If set to -1, the interface will never enter power management mode and will remain at full power until utility power is restored or battery charge is depleted.

battPowerMgmtBluetoothDelayInteger32read-write
.cableDataMgmtMIBObjects.10.3.1.5

Specifies the number of seconds following transition to battery power before the bluetooth interface will enter power management mode. If set to -1, the interface will never enter power management mode and will remain at full power until utility power is restored or battery charge is depleted.

battPowerMgmtHpnaDelayInteger32read-write
.cableDataMgmtMIBObjects.10.3.1.6

Specifies the number of seconds following transition to battery power before the HPNA interface will enter power management mode. If set to -1, the interface will never enter power management mode and will remain at full power until utility power is restored or battery charge is depleted.

bcmAlarmLowBatteryChargeOBJECTnot-accessible
.cableDataMgmtMIBObjects.10.4.1

The value of upsEstimatedChargeRemaining is less than or equal to the value of battChargerLowChargeThreshold.

bcmAlarmTempBadChargeSuspendedOBJECTnot-accessible
.cableDataMgmtMIBObjects.10.4.2

The temperature of the device has exceeded operational limits for safe battery charging, and battery charging has been suspended.

bcmAlarmTempBadPowerReducedOBJECTnot-accessible
.cableDataMgmtMIBObjects.10.4.3

The temperature of the device has exceeded operational limits, and the device has been placed in low power mode in an to attempt to reduce heat production.

bcmAlarmBatteryMissingOBJECTnot-accessible
.cableDataMgmtMIBObjects.10.4.4

There are no batteries installed in the device and the device will not be capable of sustaining power in the event of utility power loss.

bcmAlarmTempBadDischargeInhibitedOBJECTnot-accessible
.cableDataMgmtMIBObjects.10.4.5

The temperature of the device has exceeded operational limits for safe battery discharging, and battery discharging has been inhibited.

batteryEntryBatteryEntrynot-accessible
.cableDataMgmtMIBObjects.10.1.1.1

An entry describing the characteristics of an individual battery.

battIndexInteger32not-accessible
.cableDataMgmtMIBObjects.10.1.1.1.1

Identifies the instance number of this individual battery.

battCapacityUnsigned32read-only
.cableDataMgmtMIBObjects.10.1.1.1.2

The charge capacity of this battery.

battMaximumVoltageUnsigned32read-only
.cableDataMgmtMIBObjects.10.1.1.1.3

The voltage at which this battery is considered to be fully charged. Note that if battChargerMaximumCharge is set to less than 100%, the battery will never be charged to this voltage.