BAY-STACK-SFF-MIB
AI MIB Summary
The BAY-STACK-SFF-MIB enables SNMP-based monitoring and management of Avaya SFF (Small Form Factor) transceiver modules on BAY-STACK switches, exposing real-time optical parameters such as transmit and receive optical power, temperature, bias current, and module status flags.
Avaya SFF MIB
Copyright 2012 Avaya, Inc. All rights reserved. This Avaya SNMP Management Information Base Specification embodies Avaya's confidential and proprietary intellectual property. Avaya retains all title and ownership in the Specification, including any revisions.
This Specification is supplied 'AS IS,' and Avaya makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
Main OID:
bayStackDdiSfpMib.bayStackMibs.29
49
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
49 total| Object Name |
|---|
bayStackDdiSfpMibAvaya SFF MIB
Copyright 2012 Avaya, Inc.
All rights reserved.
This Avaya SNMP Management Information Base
Specification embodies Avaya's confidential and
proprietary intellectual property. Avaya retains
all title and ownership in the Specification, including any
revisions.
This Specification is supplied 'AS IS,' and Avaya
makes no warranty, either express or implied, as to the use,
operation, condition, or performance of the Specification. MODULE-IDENTITY .bayStackMibs.29 |
IMPORTSAvaya SFF MIB
Copyright 2012 Avaya, Inc.
All rights reserved.
This Avaya SNMP Management Information Base
Specification embodies Avaya's confidential and
proprietary intellectual property. Avaya retains
all title and ownership in the Specification, including any
revisions.
This Specification is supplied 'AS IS,' and Avaya
makes no warranty, either express or implied, as to the use,
operation, condition, or performance of the Specification. Unknown .bayStackMibs.29 |
bsDdiSfpNotifications OBJECT IDENTIFIER .bayStackMibs.29.0 |
bsDdiSfpTempAlarmThis notification is generated when a transceiver's temperature reaches an alarm level. NOTIFICATION-TYPE .bayStackMibs.29.0.1 |
bsDdiSfpTempWarnThis notification is generated when a transceiver's temperature reaches a warning level. NOTIFICATION-TYPE .bayStackMibs.29.0.2 |
bsDdiSfpTempNormalThis notification is generated when a transceiver's temperature reaches normal operating level.
The notification is triggered after the transceiver's temperature has reached a warning or alarm
level and then returns to normal level. NOTIFICATION-TYPE .bayStackMibs.29.0.3 |
bsDdiSfpVoltageAlarmThis notification is generated when a transceiver's voltage reaches an alarm level. NOTIFICATION-TYPE .bayStackMibs.29.0.4 |
bsDdiSfpVoltageWarnThis notification is generated when a transceiver's voltage reaches a warning level. NOTIFICATION-TYPE .bayStackMibs.29.0.5 |
bsDdiSfpVoltageNormalThis notification is generated when a transceiver's voltage reaches normal operating level.
The notification is triggered after the transceiver's voltage has reached a warning or alarm
level and then returns to normal level. NOTIFICATION-TYPE .bayStackMibs.29.0.6 |
bsDdiSfpBiasAlarmThis notification is generated when a transceiver's bias reaches an alarm level. NOTIFICATION-TYPE .bayStackMibs.29.0.7 |
bsDdiSfpBiasWarnThis notification is generated when a transceiver's bias reaches a warning level. NOTIFICATION-TYPE .bayStackMibs.29.0.8 |
bsDdiSfpBiasNormalThis notification is generated when a transceiver's bias reaches normal operating level.
The notification is triggered after the transceiver's bias has reached a warning or alarm
level and then returns to normal level. NOTIFICATION-TYPE .bayStackMibs.29.0.9 |
bsDdiSfpTxAlarmThis notification is generated when a transceiver's transmit power reaches an alarm level. NOTIFICATION-TYPE .bayStackMibs.29.0.10 |
bsDdiSfpTxWarnThis notification is generated when a transceiver's transmit power reaches a warning level. NOTIFICATION-TYPE .bayStackMibs.29.0.11 |
bsDdiSfpTxNormalThis notification is generated when a transceiver's transmit power reaches normal operating level.
The notification is triggered after the transceiver's transmit power has reached a warning or alarm
level and then returns to normal level. NOTIFICATION-TYPE .bayStackMibs.29.0.12 |
bsDdiSfpRxAlarmThis notification is generated when a transceiver's receive power reaches an alarm level. NOTIFICATION-TYPE .bayStackMibs.29.0.13 |
bsDdiSfpRxWarnThis notification is generated when a transceiver's receive power reaches a warning level. NOTIFICATION-TYPE .bayStackMibs.29.0.14 |
bsDdiSfpRxNormalThis notification is generated when a transceiver's receive power reaches normal operating level.
The notification is triggered after the transceiver's receive power has reached a warning or alarm
level and then returns to normal level. NOTIFICATION-TYPE .bayStackMibs.29.0.15 |
bsDdiSfpObjects OBJECT IDENTIFIER .bayStackMibs.29.1 |
bsDdiSfpTableThis table contains information about DDI SFPs. Entries will
exist in this table only for DDI SFP ports. SEQUENCE OF BsDdiSfpEntry .bayStackMibs.29.1.2 |
bsDdiSfpEntrySFF interface settings. BsDdiSfpEntry .bayStackMibs.29.1.2.1 |
bsDdiSfpIfIndexIdentifies the ifIndex of the SFF port. InterfaceIndex (IF-MIB) .bayStackMibs.29.1.2.1.1 |
bsDdiSfpCalibrationThis object indicates whether the actual values read from EEPROM
internally within an implementation are already calibrated to the
appropriate units (Volts, mA, dB, etc), or whether these values
are first converted to appropriate units. The value external(2)
indicates that the values as read from EEPROM must be converted.
Note that this is only an indication of what happens internally
within an implementation, and does not have any effect on the
values of other columns in this table.ro Enumeration .bayStackMibs.29.1.2.1.2 |
bsDdiSfpRxPowerMeasurementThis object indicates the measurement type used for the received
power. A value of oma(1) indicates Optical Modulation Amplitude
(OMA).ro Enumeration .bayStackMibs.29.1.2.1.3 |
bsDdiSfpTempValueThe actual temperature value, measured in 1/10000 Celsius.ro Integer32 (-1280000..1280000) .bayStackMibs.29.1.2.1.4 |
bsDdiSfpTempLowAlarmThresholdThe low alarm temperature threshold, measure in 1/10000 Celsius.ro Integer32 (-1280000..1280000) .bayStackMibs.29.1.2.1.5 |
bsDdiSfpTempLowWarnThresholdThe low warn temperature threshold, measure in 1/10000 Celsius.ro Integer32 (-1280000..1280000) .bayStackMibs.29.1.2.1.6 |
bsDdiSfpTempHighAlarmThresholdThe high alarm temperature threshold, measure in 1/10000 Celsius.ro Integer32 (-1280000..1280000) .bayStackMibs.29.1.2.1.7 |
bsDdiSfpTempHighWarnThresholdThe high warn temperature threshold, measure in 1/10000 Celsius.ro Integer32 (-1280000..1280000) .bayStackMibs.29.1.2.1.8 |
bsDdiSfpVoltageValueThe actual voltage value, measured in 1/10000 volts.ro Integer32 .bayStackMibs.29.1.2.1.9 |
bsDdiSfpVoltageLowAlarmThresholdThe low alarm voltage threshold, measured in 1/10000 volts.ro Integer32 .bayStackMibs.29.1.2.1.10 |
bsDdiSfpVoltageLowWarnThresholdThe low warn voltage threshold, measured in 1/10000 volts.ro Integer32 .bayStackMibs.29.1.2.1.11 |
bsDdiSfpVoltageHighAlarmThresholdThe high alarm voltage threshold, measured in 1/10000 volts.ro Integer32 .bayStackMibs.29.1.2.1.12 |
bsDdiSfpVoltageHighWarnThresholdThe high warn voltage threshold, measured in 1/10000 volts.ro Integer32 .bayStackMibs.29.1.2.1.13 |
bsDdiSfpBiasValueThe actual bias value, measured in 1/10000 mA.ro Integer32 .bayStackMibs.29.1.2.1.14 |
bsDdiSfpBiasLowAlarmThresholdThe low alarm bias threshold, measured in 1/10000 mA.ro Integer32 .bayStackMibs.29.1.2.1.15 |
bsDdiSfpBiasLowWarnThresholdThe low warn bias threshold, measured in 1/10000 mA.ro Integer32 .bayStackMibs.29.1.2.1.16 |
bsDdiSfpBiasHighAlarmThresholdThe high alarm bias threshold, measured in 1/10000 mA.ro Integer32 .bayStackMibs.29.1.2.1.17 |
bsDdiSfpBiasHighWarnThresholdThe high warn bias threshold, measured in 1/10000 mA.ro Integer32 .bayStackMibs.29.1.2.1.18 |
bsDdiSfpTxPowerValueThe actual transmit power value, measured in 1/10000 dBm.ro Integer32 (-400000..83000) .bayStackMibs.29.1.2.1.19 |
bsDdiSfpTxPowerLowAlarmThresholdThe low alarm transmit power threshold, measured in 1/10000 dBm.ro Integer32 (-400000..83000) .bayStackMibs.29.1.2.1.20 |
bsDdiSfpTxPowerLowWarnThresholdThe low warn transmit power threshold, measured in 1/10000 dBm.ro Integer32 (-400000..83000) .bayStackMibs.29.1.2.1.21 |
bsDdiSfpTxPowerHighAlarmThresholdThe high alarm transmit power threshold, measured in 1/10000 dBm.ro Integer32 (-400000..83000) .bayStackMibs.29.1.2.1.22 |
bsDdiSfpTxPowerHighWarnThresholdThe high warn transmit power threshold, measured in 1/10000 dBm.ro Integer32 (-400000..83000) .bayStackMibs.29.1.2.1.23 |
bsDdiSfpRxPowerValueThe actual receive power value, measured in 1/10000 dBm.ro Integer32 (-400000..83000) .bayStackMibs.29.1.2.1.24 |
bsDdiSfpRxPowerLowAlarmThresholdThe low alarm receive power threshold, measured in 1/10000 dBm.ro Integer32 (-400000..83000) .bayStackMibs.29.1.2.1.25 |
bsDdiSfpRxPowerLowWarnThresholdThe low warn receive power threshold, measured in 1/10000 dBm.ro Integer32 (-400000..83000) .bayStackMibs.29.1.2.1.26 |
bsDdiSfpRxPowerHighAlarmThresholdThe high alarm receive power threshold, measured in 1/10000 dBm.ro Integer32 (-400000..83000) .bayStackMibs.29.1.2.1.27 |
bsDdiSfpRxPowerHighWarnThresholdThe high warn receive power threshold, measured in 1/10000 dBm.ro Integer32 (-400000..83000) .bayStackMibs.29.1.2.1.28 |