BAY-STACK-NES-MIB
AI MIB Summary
The BAY-STACK-NES-MIB facilitates SNMP-based monitoring and control of energy consumption metrics and power-saving operational states on Nortel BayStack network switches. This module enables administrators to query specific power usage counters and manage the Energy Saver (NES) feature set to optimize device power efficiency.
Nortel Energy Saver (NES) MIB
Copyright 2009 Nortel Networks, Inc. All rights reserved. This Nortel Networks SNMP Management Information Base Specification embodies Nortel Networks' confidential and proprietary intellectual property. Nortel Networks retains all title and ownership in the Specification, including any revisions.
This Specification is supplied 'AS IS,' and Nortel Networks makes no warranty, either express or implied, as to the use, operation, condition, or performance of the Specification.
Main OID:
bayStackNesMib.bayStackMibs.34
35
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
35 total| Object Name |
|---|
bayStackNesMibNortel Energy Saver (NES) MIB
Copyright 2009 Nortel Networks, Inc.
All rights reserved.
This Nortel Networks SNMP Management Information Base
Specification embodies Nortel Networks' confidential and
proprietary intellectual property. Nortel Networks retains
all title and ownership in the Specification, including any
revisions.
This Specification is supplied 'AS IS,' and Nortel Networks
makes no warranty, either express or implied, as to the use,
operation, condition, or performance of the Specification. MODULE-IDENTITY .bayStackMibs.34 |
IMPORTSNortel Energy Saver (NES) MIB
Copyright 2009 Nortel Networks, Inc.
All rights reserved.
This Nortel Networks SNMP Management Information Base
Specification embodies Nortel Networks' confidential and
proprietary intellectual property. Nortel Networks retains
all title and ownership in the Specification, including any
revisions.
This Specification is supplied 'AS IS,' and Nortel Networks
makes no warranty, either express or implied, as to the use,
operation, condition, or performance of the Specification. Unknown .bayStackMibs.34 |
bayStackNesNotifications OBJECT IDENTIFIER .bayStackMibs.34.0 |
bsnesGloballyEnabledIndicates that NES was globally enabled. NOTIFICATION-TYPE .bayStackMibs.34.0.1 |
bsnesGloballyDisabledIndicates that NES was globally disabled. NOTIFICATION-TYPE .bayStackMibs.34.0.2 |
bsnesManuallyActivatedIndicates that NES was manually activated. NOTIFICATION-TYPE .bayStackMibs.34.0.3 |
bsnesManuallyDeactivatedIndicates that NES was manually deactived. NOTIFICATION-TYPE .bayStackMibs.34.0.4 |
bsnesScheduleNotAppliedIndicates that a schedule was not applied because
SNTP in not synchronized. NOTIFICATION-TYPE .bayStackMibs.34.0.5 |
bsnesScheduleAppliedIndicates that SNTP is synchronized and that the
schedule is being applied. NOTIFICATION-TYPE .bayStackMibs.34.0.6 |
bsnesActivatedIndicates that NES was activated by schedule. NOTIFICATION-TYPE .bayStackMibs.34.0.7 |
bsnesDeactivatedIndicates that NES was deactivated by schedule. NOTIFICATION-TYPE .bayStackMibs.34.0.8 |
bayStackNesObjects OBJECT IDENTIFIER .bayStackMibs.34.1 |
bsnesScalars OBJECT IDENTIFIER .bayStackMibs.34.1.1 |
bsnesEnergySaverEnabledThis object controls whether the Nortel Energy Saver feature
is enabled.rw TruthValue (SNMPv2-TC) .bayStackMibs.34.1.1.1 |
bsnesPoePowerSavingEnabledThis object controls whether Nortel Energy Saver POE power saving
is enabled.rw TruthValue (SNMPv2-TC) .bayStackMibs.34.1.1.2 |
bsnesEfficiencyModeEnabledThis object controls whether Nortel Energy Saver Efficiency-Mode
is enabled.rw TruthValue (SNMPv2-TC) .bayStackMibs.34.1.1.3 |
bsnesEnergySaverActiveThis object controls whether Nortel Energy Saver is currently active.
A value of true(1) indicates energy saving is active. A value of
false(2) indicates energy saving is currently inactive. The value
of this object will change over time as specified by the energy
saving schedule. Setting this object allows energy saving to be
manually activated or deactivated.rw TruthValue (SNMPv2-TC) .bayStackMibs.34.1.1.4 |
bsnesScheduleTableThis table contains the schedule for activation and deactivation
of the Nortel Energy Saver feature. SEQUENCE OF BsnesScheduleEntry .bayStackMibs.34.1.2 |
bsnesScheduleEntryAn energy saver schedule entry, indicates a time to activate or
deactivate energy savings. BsnesScheduleEntry .bayStackMibs.34.1.2.1 |
bsnesScheduleDayDay on which this schedule entry takes effect. Enumeration .bayStackMibs.34.1.2.1.1 |
bsnesScheduleHourHour on which this schedule entry takes effect. A value of 0 means
12am midnight. A value of 12 means 12pm noon. Integer32 .bayStackMibs.34.1.2.1.2 |
bsnesScheduleMinuteMinute on which this schedule entry takes effect. Integer32 .bayStackMibs.34.1.2.1.3 |
bsnesScheduleActionThe action taken when this schedule entry takes effect. Indicates
whether energy savings will be activated or deactivated.rw Enumeration .bayStackMibs.34.1.2.1.4 |
bsnesScheduleRowStatusUsed to create/delete schedule entries.rw RowStatus (SNMPv2-TC) .bayStackMibs.34.1.2.1.5 |
bsnesInterfaceTableThis table contains per-port NES settings. SEQUENCE OF BsnesInterfaceEntry .bayStackMibs.34.1.3 |
bsnesInterfaceEntryNES settings for a port. BsnesInterfaceEntry .bayStackMibs.34.1.3.1 |
bsnesInterfaceIndexThe ifIndex value of an interface. InterfaceIndex (IF-MIB) .bayStackMibs.34.1.3.1.1 |
bsnesInterfaceEnergySaverEnabledIndicates whether the Nortel Energy Saver feature is enabled for
this interface.rw TruthValue (SNMPv2-TC) .bayStackMibs.34.1.3.1.2 |
bsnesInterfaceEnergySaverPoeStatusIndicates the Nortel Energy Saver PoE status for this interface.ro Enumeration .bayStackMibs.34.1.3.1.3 |
bsnesSavingsTableThis table contains per-unit information about the amount of power
being saved by NES. SEQUENCE OF BsnesSavingsEntry .bayStackMibs.34.1.4 |
bsnesSavingsEntryInformation about the amount of power being saved for a unit. BsnesSavingsEntry .bayStackMibs.34.1.4.1 |
bsnesSavingsUnitIndexThe unit number. Unsigned32 .bayStackMibs.34.1.4.1.1 |
bsnesSavingsUnitSavingsIndicates the amount of switch capacity power being saved on this
unit. The value of this object is 1/10 watts.ro Unsigned32 .bayStackMibs.34.1.4.1.2 |
bsnesSavingsPoeSavingsIndicates the amount of PoE power being saved on this unit. The
value of this object is 1/10 watts.ro Unsigned32 .bayStackMibs.34.1.4.1.3 |
bayStackNesNotificationObjects OBJECT IDENTIFIER .bayStackMibs.34.2 |