Home/Catalog/BAS-SONET-MIB

BAS-SONET-MIB

AI MIB Summary

The BAS-SONET-MIB module enables the monitoring and configuration of SONET interface parameters, including line status, signal quality, and error counters, on Broadband Access System (BAS) hardware. It facilitates the management of optical transport layer connectivity and performance metrics essential for maintaining service reliability in broadband aggregation networks.

This MIB module defines the configuration and status MIB objects for a Broadband Access System SONET interface.
Main OID:
basSonetMib.1.3.6.1.4.1.3493.2.20.1
35
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

35 total
Object Name
basSonetMibThis MIB module defines the configuration and status MIB objects for a Broadband Access System SONET interface.
MODULE-IDENTITY
.1.3.6.1.4.1.3493.2.20.1
basSonetObjects
OBJECT IDENTIFIER
.1.3.6.1.4.1.3493.2.20.1.1
basSonetPathTableA table containing SONET Path specific variables for this POS implementation.
SEQUENCE OF BasSonetPathEntry
.1.3.6.1.4.1.3493.2.20.1.1.1
basSonetPathEntryManagement information about a particular POS Link.
BasSonetPathEntry
.1.3.6.1.4.1.3493.2.20.1.1.1.1
basSonetPathB3ErrThe number of packets received on this link with B3 bit errors. Bit Interleaved Parity 8 is calculated over all bits in the SPE of each frame.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.1.1.1
basSonetPathG1ErrThe number of B3 errors that were detected by the remote terminal in its received signal.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.1.1.2
basSonetPathPaisThe number of times a Path Alarm Indication Signal has been detected. A PAIS occurs if all the H1/H2 pointer bytes in the received SONET frame are 01.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.1.1.3
basSonetPathPrdiThe number of times a Path Remote Defect Indication has been detected. A PRDI occurs if bits 5,6 and 7 of the G1 byte received with the same value for 5 onsecutive frames.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.1.1.4
basSonetPathPlopThe number of times a Path Loss of Pointer has been detected. A PLOP occurs if all the H1/H2 pointer bytes in the received SONET frame are not all 01 indicating PRDI or the first pair equals 00 and all other pairs equaling 11 indicating normal operation.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.1.1.5
basSonetPathB3ThresholdThe number of packets received with B3 errors hits this threshold issue an alarm.rw
Integer32
.1.3.6.1.4.1.3493.2.20.1.1.1.1.6
basSonetPathRxJ1The first J1 byte received in last packet.ro
Integer32
.1.3.6.1.4.1.3493.2.20.1.1.1.1.7
basSonetPathRxC2C2 byte received in last packet.ro
Integer32
.1.3.6.1.4.1.3493.2.20.1.1.1.1.8
basSonetPathRxG1G1 byte received in last packet.ro
Integer32
.1.3.6.1.4.1.3493.2.20.1.1.1.1.9
basSonetLineTableA table containing SONET Line specific variables for this POS implementation.
SEQUENCE OF BasSonetLineEntry
.1.3.6.1.4.1.3493.2.20.1.1.2
basSonetLineEntryManagement information about a particular POS Link.
BasSonetLineEntry
.1.3.6.1.4.1.3493.2.20.1.1.2.1
basSonetLineTxErrThe sum of all transmit errors that caused the packet to not be transmitted. These errors consist of tx fifo error, link layer errors, minimum packet size violations, maximum packet size violations and tx parity errors.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.1
basSonetLineB1ErrThe number of packets received on this link with B1 bit errors. Bit Interleaved Parity 8 is calculated over all bytes of each frame.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.2
basSonetLineB2ErrThe number of packets received on this link with B2 bit errors. Bit Interleaved Parity 8 is calculated over all bytes of each frame except for the first three rows of the TOHro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.3
basSonetLineM1ErrThe number of B2 errors that were detected by the remote terminal in its received signal.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.4
basSonetLineRxFifoOverflowThe number of packets received on this link with an error detected in the receive fifo.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.5
basSonetLineRxAbortThe number of packets received on this link in which the abort sequence is detected.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.6
basSonetLineRxRuntsThe number of packets received on this link which are smaller than the minimum packet size.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.7
basSonetLineLocThe number of times a loss of clock has been detected. LOC occurs if no transitions are detected on the receive SONET clock for 16 periods of the transmit clock..ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.8
basSonetLineLofThe number of times a loss of frame has been detected. LOF occurs if RX_OOF (out-of-frame) is active continuously for 24 consecutive frames (3 ms).ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.9
basSonetLineLosThe number of times a loss of signal has been detected. A LOS indicates to the framer that there is no signal present from the optical receiver.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.10
basSonetLineLaisThe number of times a Line Alarm Indication Signal has been detected. A LAIS occurs if the 3 LSBs of K2 are received as '111' for 5 consecutive framesro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.11
basSonetLineLrdiThe number of times a Line Remote Defect Indication has been detected. A LRDI occurs if the 3 LSBs of K2 are not received as '110' for 5 consecutive frames.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.12
basSonetLineB1ThresholdThe number of packets received with B1 errors hits this threshold issue an alarm.rw
Integer32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.13
basSonetLineB2ThresholdThe number of packets received with B2 errors hits this threshold issue an alarm.rw
Integer32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.14
basSonetLineSFThresholdThe number of packets received with B2 errors hits this threshold issue a signal fail alarm.rw
Integer32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.15
basSonetLineSDThresholdThe number of packets received with B2 errors hits this threshold issue a signal degrade alarm.rw
Integer32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.16
basSonetLineLastClearedThe value of sysUpTime when these Counter32s were last cleared.ro
TimeStamp (SNMPv2-TC)
.1.3.6.1.4.1.3493.2.20.1.1.2.1.17
basSonetLineRxK1K1 byte received in last packet.ro
Integer32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.18
basSonetLineRxK2K2 byte received in last packet.ro
Integer32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.19
basSonetLineRxGiantsThe number of packets received on this link which are larger than the maximum packet size.ro
Counter32
.1.3.6.1.4.1.3493.2.20.1.1.2.1.20
BAS-SONET-MIB - SNMP MIB Reference | MIBs Explorer