Home/Catalog/AVAYA-ENTITY-MIB

AVAYA-ENTITY-MIB

AI MIB Summary

The AVAYA-ENTITY-MIB extends the standard Entity MIB to expose Avaya-specific hardware components, logical entities, and physical port states for granular inventory and status monitoring within Avaya networking equipment. This module enables the tracking of device sub-components, such as line cards, power supplies, and fan trays, facilitating precise fault isolation and topology mapping in Avaya enterprise environments.

This module defines private extensions for Entity MIB
Main OID:
avayaEntity.1.3.6.1.4.1.6889.1.1.99
70
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

70 total
Object Name
avayaEntityThis module defines private extensions for Entity MIB
MODULE-IDENTITY
.1.3.6.1.4.1.6889.1.1.99
avEntPhySensorTableThis table extends entPhySensorTable with thresholds on the sensors.
SEQUENCE OF AvEntPhySensorEntry
.1.3.6.1.4.1.6889.1.1.99.1
avEntPhySensorEntryThresholds for sensors described in entPhySensorTable. The Threshold values correspond to entPhySensorValue. Entries are created in this table by the agent. An entry for each physical sensor SHOULD be created at the same time as the associated entPhysicalEntry. An entry SHOULD be destroyed if the associated entPhysicalEntry is destroyed. No entry means that no thresholds are defined for the corresponding sensor
AvEntPhySensorEntry
.1.3.6.1.4.1.6889.1.1.99.1.1
avEntPhySensorHiShutdownThe system shuts down when the sensor reading reaches this valuero
EntitySensorValue (ENTITY-SENSOR-MIB)
.1.3.6.1.4.1.6889.1.1.99.1.1.1
avEntPhySensorHiWarningThe system generates a warning event when the sensor reading rises and crosses this valuero
EntitySensorValue (ENTITY-SENSOR-MIB)
.1.3.6.1.4.1.6889.1.1.99.1.1.2
avEntPhySensorHiWarningClearThe system generates a warning-clear event when the sensor reading falls and crosses below this valuero
EntitySensorValue (ENTITY-SENSOR-MIB)
.1.3.6.1.4.1.6889.1.1.99.1.1.3
avEntPhySensorLoWarningClearThe system generates a warning-clear event when the sensor reading rises and crosses this valuero
EntitySensorValue (ENTITY-SENSOR-MIB)
.1.3.6.1.4.1.6889.1.1.99.1.1.4
avEntPhySensorLoWarningThe system generates a warning event when the sensor reading falls and crosses this valuero
EntitySensorValue (ENTITY-SENSOR-MIB)
.1.3.6.1.4.1.6889.1.1.99.1.1.5
avEntPhySensorLoShutdownThe system shuts down if the sensor reaches this valuero
EntitySensorValue (ENTITY-SENSOR-MIB)
.1.3.6.1.4.1.6889.1.1.99.1.1.6
avEntPhySensorEventSupportMaskA trap and an event is generated upon threshold crossing if the correspond bit is set. Note that there may be other trap filtering mechanisms. 0/0: hiShutdown(0) 0/1: hiWarning(1) 0/2: hiWarningClear(2) 0/3: loWarningClear(3) 0/4: loWarning(4) 0/5: loShowdown(5)ro
OCTET STRING
.1.3.6.1.4.1.6889.1.1.99.1.1.7
avEntTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.6889.1.1.99.2
avEntTrapsV3separator
OBJECT IDENTIFIER
.1.3.6.1.4.1.6889.1.1.99.2.0
avEntFanFltFan Fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.1
avEntFanOkFan Fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.2
avEnt48vPwrFlt48V power supply fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.4
avEnt48vPwrFltOk48V power supply fault clear
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.5
avEnt5vPwrFlt5V power supply fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.7
avEnt5vPwrFltOk5V power supply fault clear
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.8
avEnt3300mvPwrFlt3.3V (3300mv) power supply fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.10
avEnt3300mvPwrFltOk3.3V (3300mv) power supply fault clear
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.11
avEnt2500mvPwrFlt2.5V (2500mv) power supply fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.13
avEnt2500mvPwrFltOk2.5V (2500mv) power supply fault clear
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.14
avEnt1800mvPwrFlt1.8V (1800mv) power supply fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.16
avEnt1800mvPwrFltOk1.8V (1800mv) power supply fault clear
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.17
avEnt1600mvPwrFlt1.6V (1600mv) power supply fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.19
avEnt1600mvPwrFltOk1.6V (1600mv) power supply fault clear
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.20
avEntAmbientHiTempFltAmbient High Temprature fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.22
avEntAmbientHiTempFltOkAmbient High Temprature clear
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.23
avEntAmbientLoTempFltAmbient Low Temprature fault
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.24
avEntAmbientLoTempFltOkAmbient High Temprature clear
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.2.0.25
avEntPhyUSBDevices
OBJECT IDENTIFIER
.1.3.6.1.4.1.6889.1.1.99.3
avEntPhyUSBDevicesTraps
OBJECT IDENTIFIER
.1.3.6.1.4.1.6889.1.1.99.3.0
avEntPhyUSBDeviceRemovalOnBackupRestoreOperationThe notification is based on usb mass storage device removal during backup/restore operation to it. If other usb devices are removed during this operation then no harm/syslog.
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.3.0.1
avEntPhyUSBDeviceInsecureRemovalThe notification is based on usb device insecurely removal.
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.3.0.2
avEntPhyUSBDevicePowerFailureThe notification is based on usb device lack of power. For cases as: a. Connecting device which requires more power then gateway can supply. b. Connecting USB device to non power hub which has not enough power. C. Disconnecting power from the USB HUB and there is not enough power to drive the usb devices. D. Disconnecting power from a usb device which requires external power. E. Disconnecting power from USB device and the gateway/USB Hub can not supply power to it.
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.3.0.3
avEntPhyUSBDeviceNotSupportedThe notification is based on attaching non supported usb device to the gateway. The Gateways supports usb mass storage devices based on flash drives that their sub class is SCSI and their protocol is Bulk Only Transport. The Gateways supports usb modems that complies to sub class SFF-8020i, MMC-2 (ATAPI) and protocol Control/Bulk/Interrupt protocol (with no command completion Interrupt).
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.3.0.4
avEntPhyUSBDeviceExceedMaxNumberThe notification is based on reaching the max number of usb devices connected to the gateway. G250/G350 allows only USB Modem with only one usb mass storage device at the same time.
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.3.0.5
avEntPhyUSBFileSystemNotSupportedThe notification is based on reaching connecting USB mass storage device with file system that is not supported.
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.3.0.6
avEntPhyUSBDevicesTableThis table extends entPhysicalTable with USB devices parameters.
SEQUENCE OF AvEntPhyUSBDevicesEntry
.1.3.6.1.4.1.6889.1.1.99.3.1
avEntPhyUSBDevicesEntryThis table includes extension to entPhysicalTable with usb devices parameters.
AvEntPhyUSBDevicesEntry
.1.3.6.1.4.1.6889.1.1.99.3.1.1
avEntPhyUSBDeviceUSBSupportVersionThe USB standard version. Possible values are: 1.1 and 2.0.ro
DisplayString
.1.3.6.1.4.1.6889.1.1.99.3.1.1.1
avEntPhyUSBDeviceClassCodeThe usb device class code. Value Hex Value Descriptor 1 1 Audio 2 2 CDC-Control 3 3 HID 5 5 Physical 6 6 Image (subclass & protocol must be 1) 7 7 Printer 8 8 Mass-Storage 9 9 HUB 10 A CDC-Data 11 B Chip/Smart Card 13 D Content-Security 14 E Video 220 DC Diagnostic Device (see below for details) 224 E0 Wireless Controller (see below for details) 254 FE Application-Specific (see below for details) 255 FF Vendor-Specific The G250/G350 supports usb mass storage devices of class code of 0x8 and usb modem with class 0x2.ro
Integer32
.1.3.6.1.4.1.6889.1.1.99.3.1.1.2
avEntPhyUSBDeviceSubClassCodeThe usb device subclass code. USB standard describe the following class codes: 0x01 - RBC (Reduced Block Commands) 0x02 - SFF-8020i, MMC-2 (ATAPI) 0x03 - QIC-157 0x04 - UFI 0x05 - SFF-8070i 0x06 - SCSI The G250/G350 supports 0x06 - SCSI for USB mass storage devices and 0x2 - SFF-8020i, MMC-2 (ATAPI) for USB modem.ro
Integer32
.1.3.6.1.4.1.6889.1.1.99.3.1.1.3
avEntPhyUSBDeviceProtocolThe usb device protocol code. 0x0 - Control/Bulk/Interrupt protocol (with command completion Interrupt). 0x1 - Control/Bulk/Interrupt protocol (with no command completion Interrupt). 0x50 - Bulk Only Transport. The G250/G350 supports 0x50 protocol for usb mass storage devices and 0x1 for USB modem.ro
Integer32
.1.3.6.1.4.1.6889.1.1.99.3.1.1.4
avEntPhyUSBDeviceVendorIdThe USB device vendor HEX-formatted string as it is provided to the USB host by the USB devicero
OCTET STRING
.1.3.6.1.4.1.6889.1.1.99.3.1.1.5
avEntPhyUSBDeviceSpeedThe USB device speed. Possible values: 'Low', 'Full' and 'High'. G250/G350 supports 'Full' and 'High'ro
DisplayString
.1.3.6.1.4.1.6889.1.1.99.3.1.1.6
avEntPhyUSBDevicePowerThe USB device power. Possible values: 'Unknown', 'Self Powered' and 'Bus Powered'.ro
DisplayString
.1.3.6.1.4.1.6889.1.1.99.3.1.1.7
avEntPhyUSBDeviceCurrentThe USB current consumption in mA.ro
Integer32
.1.3.6.1.4.1.6889.1.1.99.3.1.1.8
avEntPhyUSBMassStorageDevicesTableThis table extends entPhysicalTable with USB mass storage devices parameters.
SEQUENCE OF AvEntPhyUSBMassStorageDevicesEntry
.1.3.6.1.4.1.6889.1.1.99.3.2
avEntPhyUSBMassStorageDevicesEntryThis table includes extension to entPhysicalTable with usb mass storage devices parameters.
AvEntPhyUSBMassStorageDevicesEntry
.1.3.6.1.4.1.6889.1.1.99.3.2.1
avEntPhyUSBMassStorageDeviceFileSystemNameThe usb mass storage device File system name. An exmaple for one usb mass storage device on the gateway is mapped to /usbdevice0/.ro
DisplayString
.1.3.6.1.4.1.6889.1.1.99.3.2.1.1
avEntPhyUSBMassStorageDeviceCapacityCapacity of USB Mass storage device in KBytes.ro
Integer32
.1.3.6.1.4.1.6889.1.1.99.3.2.1.2
avEntPhyUSBMassStorageDeviceFreeMemoryFree memory of USB Mass storage device in KB. For R/O USB mass storage devices (as CDROM) this value returns 0. Note that this MIB item shall be updated according backup operations that may consume memory space.ro
Integer32
.1.3.6.1.4.1.6889.1.1.99.3.2.1.3
avEntPhyUSBMassStorageDeviceFsThe file system supported by the USB device. Possible values: 'FAT16' and 'FAT32'.ro
DisplayString
.1.3.6.1.4.1.6889.1.1.99.3.2.1.4
avEntPhyNotificationDefinitions
OBJECT IDENTIFIER
.1.3.6.1.4.1.6889.1.1.99.4
avEntPhySeverityThe severity of the notification.ro
AvEntPhyItuPerceivedSeverity
.1.3.6.1.4.1.6889.1.1.99.4.1
avEntPhyProductIdThe Product Id of Avaya Device - 10 characters.ro
DisplayString
.1.3.6.1.4.1.6889.1.1.99.4.2
avEntPhysicalIndexThe index for this entry.ro
PhysicalIndex (ENTITY-MIB)
.1.3.6.1.4.1.6889.1.1.99.4.3
avEntPhyChFru
OBJECT IDENTIFIER
.1.3.6.1.4.1.6889.1.1.99.5
avEntPhyChFruNotifications
OBJECT IDENTIFIER
.1.3.6.1.4.1.6889.1.1.99.5.0
avEntPhyChFruRemovalFRU unit was removed from chassis
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.5.0.1
avEntPhyChFruInsertionFRU unit was inserted into chassis
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.5.0.2
avEntPhyChFruPsuFltPower Supply unit failed
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.5.0.3
avEntPhyChFruPsuFltOkPower Supply unit resumed operation
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.5.0.4
avEntPhyChFruExpansionTestFailureCable Test Failure on Expansion module
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.5.0.5
avEntPhyChFruExpansionTestClearCable Test Passed OK on Expansion module
NOTIFICATION-TYPE
.1.3.6.1.4.1.6889.1.1.99.5.0.6
avEntPhyChFruTableTable depicting the status of chassis FRU units such as Power-Supplies and Fan-Tray
SEQUENCE OF AvEntPhyChFruEntry
.1.3.6.1.4.1.6889.1.1.99.5.1
avEntPhyChFruEntryTable entry depicting the status of chassis FRU units such as Power-Supplies and Fan-Tray
AvEntPhyChFruEntry
.1.3.6.1.4.1.6889.1.1.99.5.1.1
avEntPhyChFruOperStatOperational status of the chassis FRU unit.ro
Enumeration
.1.3.6.1.4.1.6889.1.1.99.5.1.1.1
avEntPhyChFruFaultDescription of fault, in case an FRU has failedro
Enumeration
.1.3.6.1.4.1.6889.1.1.99.5.1.1.2
AVAYA-ENTITY-MIB - SNMP MIB Reference | MIBs Explorer