Home/Catalog/ASCEND-SDSL-MIB

ASCEND-SDSL-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for ASCEND-SDSL-MIB.

39
Objects
Active
Status
2
Dependencies

Imported Objects

Objects

39 total
Object Name
ASCEND-WAN-MIBSDSL status parameters.
SEQUENCE OF SdslLineStatusEntry
.1.3.6.1.4.1.529.4.8.1
sdslLineStatisticTableSDSL statistical parameters.
SEQUENCE OF SdslLineStatisticEntry
.1.3.6.1.4.1.529.4.8.2
sdslLineStatisticEntryAn interface statistical entry containing objects to describe the interface.
SdslLineStatisticEntry
.1.3.6.1.4.1.529.4.8.2.1
sdslStatIfEntryIndexThe interface groups interface index is used to index into this table.ro
INTEGER
.1.3.6.1.4.1.529.4.8.2.1.1
sdslStatShelfIndexSDSL modules Shelf ID.ro
INTEGER
.1.3.6.1.4.1.529.4.8.2.1.2
sdslStatSlotIndexSDSL modules Slot ID.ro
INTEGER
.1.3.6.1.4.1.529.4.8.2.1.3
sdslStatLineIndexSDSL modules interface ID.ro
INTEGER
.1.3.6.1.4.1.529.4.8.2.1.4
sdslStatConnUpDaysConnection up day count.ro
INTEGER
.1.3.6.1.4.1.529.4.8.2.1.5
sdslStatConnUpHoursConnection Up 24 hour count.ro
INTEGER
.1.3.6.1.4.1.529.4.8.2.1.6
sdslStatConnUpMinutesConnection up minute count.ro
INTEGER
.1.3.6.1.4.1.529.4.8.2.1.7
sdslStatRxSignalPresentReceive signal present detection.ro
Enumeration
.1.3.6.1.4.1.529.4.8.2.1.8
sdslStatLineQualityDbLines noise margin. Reliable data will transfer with a reading of -5db or greater.ro
INTEGER
.1.3.6.1.4.1.529.4.8.2.1.9
sdslStatUpDwnCntrLine Up Down counter value displays the number of times the interface transitions from a down to up state.ro
INTEGER
.1.3.6.1.4.1.529.4.8.2.1.10
sdslStatLineSelfTestLine hardware self test results (Passed or Failed).ro
Enumeration
.1.3.6.1.4.1.529.4.8.2.1.11
sdslStatBertTimerBER test duration configuration. The BER test lasts for the duration of this timer.rw
Enumeration
.1.3.6.1.4.1.529.4.8.2.1.12
sdslStatBertEnaEnable/disable of the BER test. If nodes are connected, then the BER test is ran between the units. If this node is not connected to a remote node, then the interface is placed into analog loopback and the BER test is started.rw
Enumeration
.1.3.6.1.4.1.529.4.8.2.1.13
sdslStatBertStateBER test states. When this node is not connected to another node, the test is disabled. When two nodes are connected then the BER test waits for the other node to start it's BER test and then starts collecting bit errors immediately.ro
Enumeration
.1.3.6.1.4.1.529.4.8.2.1.14
sdslStatBertErrorCounterBER test bit error counter.ro
INTEGER
.1.3.6.1.4.1.529.4.8.2.1.15
sdslLineConfigTableSDSL status parameters.
SEQUENCE OF SdslLineConfigEntry
.1.3.6.1.4.1.529.4.8.3
sdslLineConfigEntryAn interface status entry containing objects to describe the interface.
SdslLineConfigEntry
.1.3.6.1.4.1.529.4.8.3.1
sdslConfigIfEntryIndexInterface group index assigned to this port.ro
INTEGER
.1.3.6.1.4.1.529.4.8.3.1.1
sdslConfigShelfIndexTNT's SDSL modules Shelf ID.ro
INTEGER
.1.3.6.1.4.1.529.4.8.3.1.2
sdslConfigSlotIndexTNT's SDSL modules Slot ID.ro
INTEGER
.1.3.6.1.4.1.529.4.8.3.1.3
sdslConfigLineIndexSDSL modules line ID.ro
INTEGER
.1.3.6.1.4.1.529.4.8.3.1.4
sdslConfigLineRateThe current line raterw
Enumeration
.1.3.6.1.4.1.529.4.8.3.1.5
sdslLineStatusEntryAn interface status entry containing objects to describe the interface.
SdslLineStatusEntry
.sdslLineStatusTable.1
sdslStatusIfEntryIndexInterface group index assigned to this port.ro
INTEGER
.sdslLineStatusTable.1.1
sdslStatusShelfIndexTNT's SDSL modules Shelf ID.ro
INTEGER
.sdslLineStatusTable.1.2
sdslStatusSlotIndexTNT's SDSL modules Slot ID.ro
INTEGER
.sdslLineStatusTable.1.3
sdslStatusLineIndexSDSL modules line ID.ro
INTEGER
.sdslLineStatusTable.1.4
sdslStatusUnitTypeUnit type defines if the unit is operating either as a Central Office Equipment (COE) or Customer Premiss equipment (CPE).ro
Enumeration
.sdslLineStatusTable.1.5
sdslStatusLineStateInterface state describes the current ports operating state. States are: Config, Pend Down, Up, Down, Start-up, or N/A.ro
Enumeration
.sdslLineStatusTable.1.6
sdslStatusUpRateThe current up stream (cpe to coe) rate The object dslStatusUpRate is deprecated. To set line rate the object sdslConfigLineRate of the new sdslLineConfigTable should be used.rwdeprecated
Enumeration
.sdslLineStatusTable.1.7
sdslStatusDownRateThe current down stream (coe to cpe) rate The object dslStatusDownRate is deprecated. To set line rate the object sdslConfigLineRate of the new sdslLineConfigTable should be used.rwdeprecated
Enumeration
.sdslLineStatusTable.1.8
sdslStatusVendorIdVendor identification.ro
INTEGER
.sdslLineStatusTable.1.9
sdslStatusMajorFirmWareVerMajor firmware version.ro
INTEGER
.sdslLineStatusTable.1.10
sdslStatusMinorFirmWareVerMinor firmware version.ro
INTEGER
.sdslLineStatusTable.1.11
sdslStatusHardWareVerHardware version.ro
INTEGER
.sdslLineStatusTable.1.12
sdslStatusLineRateThe current line ratero
Enumeration
.sdslLineStatusTable.1.13
ASCEND-SDSL-MIB - SNMP MIB Reference | MIBs Explorer