ASCEND-CALL-MIB
AI MIB Summary
Standard SNMP MIB module defining data structures for ASCEND-CALL-MIB.
54
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
54 total| Object Name |
|---|
RFC1213-MIBThe maximum number of entries that can exist
in the call status table.ro INTEGER .1.3.6.1.4.1.529.11.1 |
callStatusTableA list of call status entries. SEQUENCE OF CallStatusEntry .1.3.6.1.4.1.529.11.2 |
callStatusEntryAn entry containing object variables to describe
a call's status. CallStatusEntry .1.3.6.1.4.1.529.11.2.1 |
callStatusIndexThe index number for this call status entry. Its
value ranges from 1 to 'callStatusMaximumEntries'.ro INTEGER .1.3.6.1.4.1.529.11.2.1.1 |
callStatusValidFlagValue indicates whether this entry indexed by
'callStatusIndex' contains valid information or not.ro Enumeration .1.3.6.1.4.1.529.11.2.1.2 |
callStatusStartingTimeStampThe starting time for this call in seconds
since startup. A value of 0 is returned if
entry is invalid (ie. 'callStatusValidFlag' is
invalid(1)).ro INTEGER .1.3.6.1.4.1.529.11.2.1.3 |
callStatusCallReferenceNumThe unique number identifying the session for which
this call is associated. A value of 0 is returned
if entry is invalid.ro INTEGER (1..'7fffffff'h) SYNTAX INTEGER .1.3.6.1.4.1.529.11.2.1.4 |
callStatusDataRateThe receive rate for ISDN calls or the baud rate
for modem calls. A value of 0 is returned if entry
is invalid.ro INTEGER .1.3.6.1.4.1.529.11.2.1.5 |
callStatusSlotNumberIdentifies the slot of the line being used. It's
value ranges between 1 and the value 'slotNumber'
in Ascend's slots group. This variable is equivalent
to 'slotIndex' in the slot group. A value of 0 is
returned if entry is invalid.ro INTEGER .1.3.6.1.4.1.529.11.2.1.6 |
callStatusSlotLineNumberIdentifies the line for network slots. This variable
is equivalent to 'slotItemIndex' in Ascend's slot
group. A value of 0 is returned if entry is invalid.ro INTEGER .1.3.6.1.4.1.529.11.2.1.7 |
callStatusSlotChannelNumberIdentifies the channel for the particular line
identified by 'callStatusSlotLineNumber'. A value
of 0 is returned if entry is invalid.ro INTEGER .1.3.6.1.4.1.529.11.2.1.8 |
callStatusModemSlotNumberIdentifies the slot on the device. It's
value ranges between 1 and the value 'slotNumber'
in Ascend's slot group. A value of 0 is returned
if entry is invalid.ro INTEGER .1.3.6.1.4.1.529.11.2.1.9 |
callStatusModemOnSlotIt identifies the particular port within a slot.
A value of 0 is returned if entry is invalid.ro INTEGER .1.3.6.1.4.1.529.11.2.1.10 |
callStatusIfIndexThe interface index, ranging from 1 to the number of
interfaces specified in the MIB-II variable ifNumber.
The interface identified by a particular value of
this index is the same interface as identified by the
same value if ifIndex. A value of 0 is returned if
entry is invalid.ro INTEGER .1.3.6.1.4.1.529.11.2.1.11 |
callSessionIndexThe index of the associated session entry. Value
ranges from 1 to 'ssnStatusMaximumSessions'.
A value of 0 is returned if entry is invalid.ro INTEGER .1.3.6.1.4.1.529.11.2.1.12 |
callStatusTypeA value of 0 is returned if entry is invalid.ro Enumeration .1.3.6.1.4.1.529.11.2.1.13 |
callStatusXmitRateThe transmit rate for ISDN calls or the baud rate
for modem calls. A value of 0 is returned if entry
is invalid.ro INTEGER .1.3.6.1.4.1.529.11.2.1.14 |
callStatusPortTypeThe port type associated with the call.ro Enumeration .1.3.6.1.4.1.529.11.2.1.15 |
callStatusCalledParyIDThe called party Number. In case of incoming calls
this is set to the DNIS, in the case of outgoing
calls this is set to the number dialed.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.529.11.2.1.16 |
callStatusCallingPartyIDThe calling party Number. In the case of incoming calls
this variable is set to the CLID ( calling Line Identification )
received. This variable is set to the empty string for
outgoing calls.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.529.11.2.1.17 |
callStatusMultiLinkIDThis is applicable only when the call is part
of an MPP bundle, for other cases it is 0.ro INTEGER .1.3.6.1.4.1.529.11.2.1.18 |
callStatusHighWaterMarkThe highest number of channels ever used on the
wide area network since power up. Nailed channels,
if any, are also included in this count. Its value can
be set to zero with a SET command.rw INTEGER .1.3.6.1.4.1.529.11.3 |
callCurrentAnalogOutgoingThe number of current analog outgoing calls
is returned.ro INTEGER .1.3.6.1.4.1.529.11.4 |
callCurrentAnalogIncomingThe number of current analog incoming calls
is returned.ro INTEGER .1.3.6.1.4.1.529.11.5 |
callCurrentDigitalOutgoingThe number of current digital outgoing calls
is returned.ro INTEGER .1.3.6.1.4.1.529.11.6 |
callCurrentDigitalIncomingThe number of current digital incoming calls
is returned.ro INTEGER .1.3.6.1.4.1.529.11.7 |
callCurrentFROutgoingThe number of current frame relay outgoing calls
is returned.ro INTEGER .1.3.6.1.4.1.529.11.8 |
callCurrentFRIncomingThe number of current frame relay incoming calls
is returned.ro INTEGER .1.3.6.1.4.1.529.11.9 |
callTotalAnalogOutgoingThe total number of analog outgoing calls
since system bootup or last clear of the
variable is returned.rw INTEGER .1.3.6.1.4.1.529.11.10 |
callTotalAnalogIncomingThe total number of analog incoming calls
since system bootup or last clear of the
variable is returned.rw INTEGER .1.3.6.1.4.1.529.11.11 |
callTotalDigitalOutgoingThe total number of digital outgoing calls
since system bootup or last clear of the
variable is returned.rw INTEGER .1.3.6.1.4.1.529.11.12 |
callTotalDigitalIncomingThe total number of digital incoming calls
since system bootup or last clear of the
variable is returned.rw INTEGER .1.3.6.1.4.1.529.11.13 |
callTotalFROutgoingThe total number of frame relay outgoing calls
since system bootup or last clear of the
variable is returned.rw INTEGER .1.3.6.1.4.1.529.11.14 |
callTotalFRIncomingThe total number of frame relay incoming calls
since system bootup or last clear of the
variable is returned.rw INTEGER .1.3.6.1.4.1.529.11.15 |
callActiveTableA list of active call status entries. SEQUENCE OF CallActiveEntry .1.3.6.1.4.1.529.11.16 |
callActiveEntryAn entry containing object variables to describe
an active call's status. CallActiveEntry .1.3.6.1.4.1.529.11.16.1 |
callActiveCallReferenceNumThe unique number identifying the session for which
this call is associated.ro INTEGER (1..'7fffffff'h) SYNTAX INTEGER .1.3.6.1.4.1.529.11.16.1.1 |
callActiveIndexThe index number for this call status entry. Its
value ranges from 1 to 'callStatusMaximumEntries'.ro INTEGER .1.3.6.1.4.1.529.11.16.1.2 |
callActiveValidFlagvalid(2) for all active calls.ro Enumeration .1.3.6.1.4.1.529.11.16.1.3 |
callActiveStartingTimeStampThe starting time for this call in seconds
since startup.ro INTEGER .1.3.6.1.4.1.529.11.16.1.4 |
callActiveDataRateThe receive rate for ISDN calls or the baud rate
for modem calls.ro INTEGER .1.3.6.1.4.1.529.11.16.1.5 |
callActiveSlotNumberIdentifies the slot of the line being used. It's
value ranges between 1 and the value 'slotNumber'
in Ascend's slots group. This variable is equivalent
to 'slotIndex' in the slot group.ro INTEGER .1.3.6.1.4.1.529.11.16.1.6 |
callActiveSlotLineNumberIdentifies the line for network slots. This variable
is equivalent to 'slotItemIndex' in Ascend's slot
group.ro INTEGER .1.3.6.1.4.1.529.11.16.1.7 |
callActiveSlotChannelNumberIdentifies the channel for the particular line
identified by 'callActiveSlotLineNumber'.ro INTEGER .1.3.6.1.4.1.529.11.16.1.8 |
callActiveModemSlotNumberIdentifies the slot on the device. It's
value ranges between 1 and the value 'slotNumber'
in Ascend's slot group. A value of 0 is returned if
entry is invalid.ro INTEGER .1.3.6.1.4.1.529.11.16.1.9 |
callActiveModemOnSlotIt identifies the particular port within a slot.
A value of 0 is returned if entry is invalid.ro INTEGER .1.3.6.1.4.1.529.11.16.1.10 |
callActiveIfIndexThe interface index, ranging from 1 to the number of
interfaces specified in the MIB-II variable ifNumber.
The interface identified by a particular value of
this index is the same interface as identified by the
same value if ifIndex.ro INTEGER .1.3.6.1.4.1.529.11.16.1.11 |
callActiveSessionIndexThe index of the associated session entry. Value
ranges from 1 to 'ssnActiveMaximumSessions'.ro INTEGER .1.3.6.1.4.1.529.11.16.1.12 |
callActiveTypeDifferenciates between outgoing and incoming calls.ro Enumeration .1.3.6.1.4.1.529.11.16.1.13 |
callActiveXmitRateThe transmit rate for ISDN calls or the baud rate
for modem calls.ro INTEGER .1.3.6.1.4.1.529.11.16.1.14 |
callActivePortTypeThe port type associated with the call.ro Enumeration .1.3.6.1.4.1.529.11.16.1.15 |
callActiveCalledParyIDThe called party Number. In case of incoming calls
this is set to the DNIS, in the case of outgoing
calls this is set to the number dialed.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.529.11.16.1.16 |
callActiveCallingPartyIDThe calling party Number. In the case of incoming calls
this variable is set to the CLID ( calling Line Identification )
received. This variable is set to the empty string for outgoing calls.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.529.11.16.1.17 |
callActiveMultiLinkIDThis is applicable only when the call is part
of an MPP bundle, for other cases it is 0.ro INTEGER .1.3.6.1.4.1.529.11.16.1.18 |