ARUBAWIRED-FAN-MIB
The ARUBAWIRED-FAN-MIB provides SNMP management objects for monitoring the operational status, speed, and failure states of cooling fans on Aruba Wired infrastructure devices. It enables automated detection of fan degradation or failure to trigger alerts and maintain thermal safety thresholds within network hardware.
Imported Objects
Objects
20 total| Object Name |
|---|
arubaWiredFan MODULE-IDENTITY .1.3.6.1.4.1.47196.4.1.1.3.11.5 |
arubaWiredFanNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.47196.4.1.1.3.11.5.0 |
arubaWiredFanStateNotification NOTIFICATION-TYPE .1.3.6.1.4.1.47196.4.1.1.3.11.5.0.1 |
arubaWiredFanTable SEQUENCE OF ArubaWiredFanEntry .1.3.6.1.4.1.47196.4.1.1.3.11.5.1 |
arubaWiredFanEntry ArubaWiredFanEntry .1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1 |
arubaWiredFanGroupIndex Integer32 .1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.1 |
arubaWiredFanTrayIndex Integer32 .1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.2 |
arubaWiredFanSlotIndex Integer32 .1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.3 |
arubaWiredFanNamero DisplayString .1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.4 |
arubaWiredFanStatero DisplayString .1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.5 |
arubaWiredFanProductNamero DisplayString .1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.6 |
arubaWiredFanSerialNumberro DisplayString .1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.7 |
arubaWiredFanRPMro Integer32 UNITS "RPM" .1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.8 |
arubaWiredFanAirflowDirectionro DisplayString .1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.9 |
arubaWiredFanConformance OBJECT IDENTIFIER .1.3.6.1.4.1.47196.4.1.1.3.11.5.99 |
arubaWiredFanCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.47196.4.1.1.3.11.5.99.1 |
arubaWiredFanCompliance Unknown .1.3.6.1.4.1.47196.4.1.1.3.11.5.99.1.1 |
arubaWiredFanGroups OBJECT IDENTIFIER .1.3.6.1.4.1.47196.4.1.1.3.11.5.99.2 |
arubaWiredFanTableGroup Unknown .1.3.6.1.4.1.47196.4.1.1.3.11.5.99.2.1 |
arubaWiredFanNotificationsGroup Unknown .1.3.6.1.4.1.47196.4.1.1.3.11.5.99.2.2 |
ARUBAWIRED-FAN-MIB Technical Reference Overview
The ARUBAWIRED-FAN-MIB SNMP MIB module published by HPE/Aruba Networking Division defines 20 managed OID objects, including 12 scalar/column metrics, 1 SNMP tables, and 1 trap/notification events anchored at base OID .1.3.6.1.4.1.47196.4.1.1.3.11.5. Key tabular structures include arubaWiredFanTable. Monitored SNMP traps/notifications include arubaWiredFanStateNotification.
Key OID Definitions in ARUBAWIRED-FAN-MIB
.1.3.6.1.4.1.47196.4.1.1.3.11.5This MIB module describes management objects that manage Fans.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.1This table contains one row per switch fan entity.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.0.1A notification generated when a fan state change occurs. This can happen if a fan is inserted, removed, or experiences a fault.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.99.1.1A compliance statement for Aruba switch chassis.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.99.2.2Notifications sent by fan management.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.99.2.1A collection of objects display configuration, status, and measurements of Fan table.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.9Air flow direction for the fan.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1Information about the fan physical entity table.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.1This variable uniquely identifies the group containing the fan. Group means chassis in the stack and the value 1 MUST be used for non-modular devices.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.4Identification of the fan for the system.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.6Fan product name identification.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.8Current RPM read for the fan.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.7Fan serial number to uniquely identify the fan.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.3This variable uniquely identifies the fan instance in a fan tray and value 1 must be used for non-modular devices.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.5Current status for the fan.
.1.3.6.1.4.1.47196.4.1.1.3.11.5.1.1.2This variable uniquely identifies the fan tray instance in a chassis that contains the fan. A value 1 must be used for non-modular devices.
More MIBs from HPE/Aruba Networking Division
Browse all HPE/Aruba Networking DivisionMIBs →The ARUBAWIRED-NETWORKING-OID MIB module provides proprietary extensions for monitoring HPE Aruba Networking hardware, enabling the retrieval of device-specific operational metrics, interface statistics, and system health indicators not covered by standard SNMP MIBs.
The ARUBAWIRED-MGMD-SNOOPING-MIB enables monitoring and management of Multicast Group Management Daemon (MGMD) snooping configurations and state metrics on HPE Aruba wired network switches. This module provides visibility into multicast group memberships, snooping table entries, and interface-specific filtering states to optimize Layer 2 multicast traffic forwarding.
The ARUBAWIRED-PM-MIB enables SNMP-based monitoring and management of pluggable optical transceivers and SFP modules on Aruba wired network infrastructure, exposing critical telemetry such as optical power levels, laser bias currents, temperature, and voltage status for hardware health verification.
The ARUBAWIRED-RPVST-MIB module enables monitoring and management of Rapid Per-VLAN Spanning Tree (RPVST) protocol states, port roles, and topology changes on Aruba wired network switches. It provides visibility into VLAN-specific spanning tree instances, including root bridge election, port blocking/forwarding status, and BPDU transmission metrics for each configured VLAN.
The ARUBAWIRED-LLDP-MIB enables monitoring of Link Layer Discovery Protocol (LLDP) objects specifically for Power Source Equipment (PSE) capabilities on HPE Aruba wired network devices. This module facilitates the retrieval of power negotiation parameters, such as Power via MDI (802.3af/at) status and allocated power levels, to manage PoE distribution and device connectivity.
The ARUBAWIRED-VSX-MIB provides SNMP access to monitor and manage High Availability and Virtual Switching Extension (VSX) cluster states, synchronization status, and inter-chassis link health on HPE Aruba CX switches. It exposes specific metrics for VSX peer relationships, including active/standby roles, keepalive status, and configuration synchronization counters to ensure cluster integrity.