APTIS-V2TRAPS-MIB

AI MIB Summary

The APTIS-V2TRAPS-MIB module defines SNMP trap variables for the Aptis platform to notify management systems of specific system events and notification states. These traps enable real-time monitoring of critical infrastructure alerts, such as hardware faults, service disruptions, or configuration changes, within the Aptis environment.

The following variables describe the Aptis Notifications.
Main OID:
aptisTrapsModule.aptis-modules.7
104
Objects
Active
Status
7
Dependencies

Imported Objects

Objects

104 total
Object Name
aptisTrapsModule
MODULE-IDENTITY
.aptis-modules.7
aptisProtraps
OBJECT IDENTIFIER
.aptis-traps.1
aptisProtrapsV2
OBJECT IDENTIFIER
.aptis-traps.1.0
aptis-fandown
NOTIFICATION-TYPE
.aptis-traps.1.0.1
aptis-dc1down
NOTIFICATION-TYPE
.aptis-traps.1.0.2
aptis-dc2down
NOTIFICATION-TYPE
.aptis-traps.1.0.3
aptis-ac1down
NOTIFICATION-TYPE
.aptis-traps.1.0.4
aptis-ac2down
NOTIFICATION-TYPE
.aptis-traps.1.0.5
aptis-acdc1down
NOTIFICATION-TYPE
.aptis-traps.1.0.6
aptis-acdc2down
NOTIFICATION-TYPE
.aptis-traps.1.0.7
aptis-acdc3down
NOTIFICATION-TYPE
.aptis-traps.1.0.8
aptis-flashmount
NOTIFICATION-TYPE
.aptis-traps.1.0.9
aptis-flashdismount
NOTIFICATION-TYPE
.aptis-traps.1.0.10
aptis-coldStart
NOTIFICATION-TYPE
.aptis-traps.1.0.11
warmStart
NOTIFICATION-TYPE
.aptis-traps.1.0.12
linkDown
NOTIFICATION-TYPE
.aptis-traps.1.0.13
linkUp
NOTIFICATION-TYPE
.aptis-traps.1.0.14
authenticationFailure
NOTIFICATION-TYPE
.aptis-traps.1.0.15
aptis-radius-fail
NOTIFICATION-TYPE
.aptis-traps.1.0.16
aptis-slot-up
NOTIFICATION-TYPE
.aptis-traps.1.0.17
aptis-slot-down
NOTIFICATION-TYPE
.aptis-traps.1.0.18
aptis-slot-cfg-chng
NOTIFICATION-TYPE
.aptis-traps.1.0.19
aptis-ds1-red-alarm
NOTIFICATION-TYPE
.aptis-traps.1.0.20
aptis-ds1-yellow-alarm
NOTIFICATION-TYPE
.aptis-traps.1.0.21
aptis-ds1-alarm-clear
NOTIFICATION-TYPE
.aptis-traps.1.0.22
aptis-ds3-red-alarm
NOTIFICATION-TYPE
.aptis-traps.1.0.23
aptis-ds3-yellow-alarm
NOTIFICATION-TYPE
.aptis-traps.1.0.24
aptis-ds3-alarm-clear
NOTIFICATION-TYPE
.aptis-traps.1.0.25
aptis-temp-exceeded
NOTIFICATION-TYPE
.aptis-traps.1.0.29
aptis-cvx-ss7-gateway-failover
NOTIFICATION-TYPE
.aptis-traps.1.0.30
aptis-l2f-tunnel-start
NOTIFICATION-TYPE
.aptis-traps.1.0.31
aptis-l2f-tunnel-stop
NOTIFICATION-TYPE
.aptis-traps.1.0.32
aptis-l2f-tunnel-reject
NOTIFICATION-TYPE
.aptis-traps.1.0.33
cvx-MAC-modems-below-threshold
NOTIFICATION-TYPE
.aptis-traps.1.0.34
cvx-MAC-modems-above-threshold
NOTIFICATION-TYPE
.aptis-traps.1.0.35
cvx-total-modems-below-threshold
NOTIFICATION-TYPE
.aptis-traps.1.0.36
cvx-total-modems-above-threshold
NOTIFICATION-TYPE
.aptis-traps.1.0.37
cvx-local-pswd-change
NOTIFICATION-TYPE
.aptis-traps.1.0.38
cvx-auth-server-failover
NOTIFICATION-TYPE
.aptis-traps.1.0.39
cvx-acct-server-failure
NOTIFICATION-TYPE
.aptis-traps.1.0.40
cvx-acct-server-failover
NOTIFICATION-TYPE
.aptis-traps.1.0.41
cvx-ss7-gateway-down
NOTIFICATION-TYPE
.aptis-traps.1.0.42
cvx-ss7-gateway-up
NOTIFICATION-TYPE
.aptis-traps.1.0.43
cvx-Ds3-failover
NOTIFICATION-TYPE
.aptis-traps.1.0.44
cvx-Scc-failover
NOTIFICATION-TYPE
.aptis-traps.1.0.45
cvx-ethernet-port-up
NOTIFICATION-TYPE
.aptis-traps.1.0.46
cvx-ethernet-port-down
NOTIFICATION-TYPE
.aptis-traps.1.0.47
cvx-Hssi-port-up
NOTIFICATION-TYPE
.aptis-traps.1.0.48
cvx-Hssi-port-down
NOTIFICATION-TYPE
.aptis-traps.1.0.49
cvx-local-auth-failure-threshold-exceeded
NOTIFICATION-TYPE
.aptis-traps.1.0.50
cvx-preAuth-fail
NOTIFICATION-TYPE
.aptis-traps.1.0.51
cvx-auth-fail
NOTIFICATION-TYPE
.aptis-traps.1.0.52
cvx-tunnel-start
NOTIFICATION-TYPE
.aptis-traps.1.0.53
cvx-tunnel-stop
NOTIFICATION-TYPE
.aptis-traps.1.0.54
cvx-tunnel-reject
NOTIFICATION-TYPE
.aptis-traps.1.0.55
cvx-radius-packet-discard
NOTIFICATION-TYPE
.aptis-traps.1.0.56
cvx-fanup
NOTIFICATION-TYPE
.aptis-traps.1.0.57
cvx-dc1up
NOTIFICATION-TYPE
.aptis-traps.1.0.58
cvx-dc2up
NOTIFICATION-TYPE
.aptis-traps.1.0.59
cvx-acdc1up
NOTIFICATION-TYPE
.aptis-traps.1.0.62
cvx-acdc2up
NOTIFICATION-TYPE
.aptis-traps.1.0.63
cvx-acdc3up
NOTIFICATION-TYPE
.aptis-traps.1.0.64
cvx-filter-error
NOTIFICATION-TYPE
.aptis-traps.1.0.65
cvx-slave-flash-missing
NOTIFICATION-TYPE
.aptis-traps.1.0.66
cvxSlaveSccFlashDetected
NOTIFICATION-TYPE
.aptis-traps.1.0.67
cvxAuthServerRevived
NOTIFICATION-TYPE
.aptis-traps.1.0.68
cvxPrimaryDhcpServerContactFailed
NOTIFICATION-TYPE
.aptis-traps.1.0.69
cvxPrimaryDhcpServerContactRevived
NOTIFICATION-TYPE
.aptis-traps.1.0.70
cvxSecondaryDhcpServerContactFailed
NOTIFICATION-TYPE
.aptis-traps.1.0.71
cvxSlotTempWarning
NOTIFICATION-TYPE
.aptis-traps.1.0.73
cvxSlotTempNormal
NOTIFICATION-TYPE
.aptis-traps.1.0.74
cvxSlaveSccRemoved
NOTIFICATION-TYPE
.aptis-traps.1.0.75
cvxSlaveSccInserted
NOTIFICATION-TYPE
.aptis-traps.1.0.76
cvxFailedSlaveSccRemoved
NOTIFICATION-TYPE
.aptis-traps.1.0.77
cvxCardCrashed
NOTIFICATION-TYPE
.aptis-traps.1.0.79
cvxCardNotResponding
NOTIFICATION-TYPE
.aptis-traps.1.0.80
cvxLocalAuthenticationFailure
NOTIFICATION-TYPE
.aptis-traps.1.0.81
cvxSessionAuthenticationFailure
NOTIFICATION-TYPE
.aptis-traps.1.0.82
encryptionNotAllowed
NOTIFICATION-TYPE
.aptis-traps.1.0.83
cvxRadiusdSessionDisc
NOTIFICATION-TYPE
.aptis-traps.1.0.84
cvxRadiusdUnknownClient
NOTIFICATION-TYPE
.aptis-traps.1.0.85
cvxRadiusdClientAuthFailed
NOTIFICATION-TYPE
.aptis-traps.1.0.86
cvxSlaveSccFileSyncFailed
NOTIFICATION-TYPE
.aptis-traps.1.0.87
cvxSlaveSccFileSyncCompleted
NOTIFICATION-TYPE
.aptis-traps.1.0.88
cvxSlaveSccFailed
NOTIFICATION-TYPE
.aptis-traps.1.0.89
trapGenNumro
INTEGER
.aptis-traps.2
trapPathro
OCTET STRING
.aptis-traps.3
trapSeverityro
INTEGER
.aptis-traps.4
trapStringro
OCTET STRING
.aptis-traps.5
trapIpAddrro
IpAddress
.aptis-traps.6
trapSlotNumro
INTEGER
.aptis-traps.7
trapPortNumro
INTEGER
.aptis-traps.8
trapTunnelTypero
Enumeration
.aptis-traps.9
trapUserNamero
OCTET STRING
.aptis-traps.10
trapAuthThresholdro
INTEGER
.aptis-traps.11
trapFilterNamero
OCTET STRING
.aptis-traps.12
trapTempCurrentro
INTEGER UNITS "Degrees Celsius"
.aptis-traps.13
Showing 100 of 104 OID objects

APTIS-V2TRAPS-MIB Technical Reference Overview

The APTIS-V2TRAPS-MIB SNMP MIB module published by Default defines 104 managed OID objects, including 16 scalar/column metrics, 0 SNMP tables, and 85 trap/notification events anchored at base OID .aptis-modules.7. Monitored SNMP traps/notifications include aptis-fandown, aptis-dc1down, aptis-dc2down, aptis-ac1down, aptis-ac2down, aptis-acdc1down.

Key OID Definitions in APTIS-V2TRAPS-MIB

aptisTrapsModuleMODULE-IDENTITYnot-accessible
.aptis-modules.7

The following variables describe the Aptis Notifications.

aptis-fandownNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.1

The fans on the chassis have stopped functioning. This trap is only supported on systems with the smart fan tray. This trap carries a severity of 6 (emergency).

aptis-dc1downNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.2

The DC1 power supply has stopped functioning. This trap carries a severity of 6 (emergency).

aptis-dc2downNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.3

The DC2 power supply has stopped functioning. This trap carries a severity of 6 (emergency).

aptis-ac1downNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.4

The AC1 power supply has stopped functioning. This trap is no longer supported.

aptis-ac2downNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.5

The AC2 power supply has stopped functioning. This trap is no longer supported.

aptis-acdc1downNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.6

The ACDC1 power converter has stopped functioning. This trap carries a severity of 6 (emergency).

aptis-acdc2downNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.7

The ACDC2 power converter has stopped functioning. This trap carries a severity of 6 (emergency).

aptis-acdc3downNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.8

The ACDC3 power converter has stopped functioning. This trap carries a severity of 6 (emergency).

aptis-flashmountNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.9

The flash card has been mounted. See also trap aptis-flashdismount. This trap carries a severity of 2 (warning).

aptis-flashdismountNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.10

The flash card has been dismounted. See also trap aptis-flashmount. This trap carries a severity of 2 (warning).

aptis-coldStartNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.11

A coldStart trap signifies that the sending protocol entity is reinitializing itself such that the agent's configuration or the protocol entity implementation may be altered. This trap carries a severity of 2 (warning).

warmStartNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.12

A warmStart trap signifies that the sending protocol entity is reinitializing itself such that neither the agent configuration nor the protocol entity implementation is altered. This trap carries a severity of 2 (warning).

linkDownNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.13

A linkDown trap signifies that the sending protocol entity recognizes a failure in one of the communications links represented in the agent's configuration. This trap carries a severity of 6 (emergency).

linkUpNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.14

A linkUp trap signifies that the sending protocol entity recognizes that one of the communications links represented in the agent's configuration has come up. This trap carries a severity of 6 (emergency).

authenticationFailureNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.15

An authenticationFailure trap signifies that the sending protocol entity is the addressee of a protocol message that is not properly authenticated. While implementations of the SNMP must be capable of generating this trap, they must also be capable of suppressing the emission of such traps via an implementation-specific mechanism. NOTE: This trap has been obsoleted and replaced by specific trap #s 81 (cvxLocalAuthenticationFailure) and 82 (cvxSessionAuthenticationFailure) and generic trap # 5 (authenticationFailure). This trap carries a severity of 3 (error).

aptis-radius-failNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.16

No Radius Server is available. This trap carries a severity of 5 (alert).

aptis-slot-upNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.17

Slot is up. See also trap aptis-slot-down. This trap carries a severity of 5 (alert).

aptis-slot-downNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.18

Slot is down. See also trap aptis-slot-up. This trap carries a severity of 5 (alert).

aptis-slot-cfg-chngNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.19

Slot configuration has changed. This trap carries a severity of 1 (notice).

aptis-ds1-red-alarmNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.20

The specified DS1 is in red alarm. See also trap aptis-ds1-alarm-clear. This trap carries a severity of 5 (alert).

aptis-ds1-yellow-alarmNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.21

The specified DS1 is in yellow alarm. See also trap aptis-ds1-alarm-clear. This trap carries a severity of 5 (alert).

aptis-ds1-alarm-clearNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.22

The specified DS1 is no longer in alarm. See also traps aptis-ds1-red-alarm and aptis-ds1-yellow-alarm. This trap carries a severity of 5 (alert).

aptis-ds3-red-alarmNOTIFICATION-TYPEnot-accessible
.aptis-traps.1.0.23

The specified DS3 is in red alarm. See also trap aptis-ds3-alarm-clear. This trap carries a severity of 5 (alert).