ANDOVER-CONTROLS-MIB
The ANDOVER-CONTROLS-MIB module facilitates the monitoring and management of Andover Controls NetLinx network controllers and associated field devices, providing access to operational status, configuration parameters, and environmental telemetry data via SNMP. This module enables administrators to track device availability, I/O states, and system health metrics critical for maintaining building automation and industrial control infrastructure.
Imported Objects
Objects
15 total| Object Name |
|---|
andoverControls MODULE-IDENTITY .1.3.6.1.4.1.10829 |
accAlarmAgentdeprecated OBJECT IDENTIFIER .1.3.6.1.4.1.10829.1 |
accCommon OBJECT IDENTIFIER .1.3.6.1.4.1.10829.4 |
accProduct OBJECT IDENTIFIER .1.3.6.1.4.1.10829.5 |
accInfinetController OBJECT IDENTIFIER .1.3.6.1.4.1.10829.5.1 |
accNetController OBJECT IDENTIFIER .1.3.6.1.4.1.10829.5.2 |
accFrontEnd OBJECT IDENTIFIER .1.3.6.1.4.1.10829.5.3 |
accSystem OBJECT IDENTIFIER .1.3.6.1.4.1.10829.6 |
accModelro DisplayString .1.3.6.1.4.1.10829.6.1 |
accFirmwareVersionro DisplayString .1.3.6.1.4.1.10829.6.2 |
accConformance OBJECT IDENTIFIER .1.3.6.1.4.1.10829.7 |
accGroups OBJECT IDENTIFIER .1.3.6.1.4.1.10829.7.2 |
accSystemGroup Unknown .1.3.6.1.4.1.10829.7.2.1 |
accCompliance OBJECT IDENTIFIER .1.3.6.1.4.1.10829.7.3 |
accBasicCompliance Unknown .1.3.6.1.4.1.10829.7.3.1 |
ANDOVER-CONTROLS-MIB Technical Reference Overview
The ANDOVER-CONTROLS-MIB SNMP MIB module published by Andover Controls defines 15 managed OID objects, including 4 scalar/column metrics, 0 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.10829.
Key OID Definitions in ANDOVER-CONTROLS-MIB
.1.3.6.1.4.1.10829This is the MIB module at the top of the Andover Controls enterprise group.
.1.3.6.1.4.1.10829.7.3.1Compliance requires these nodes.
.1.3.6.1.4.1.10829.6.2Version of the firmware running on device.
.1.3.6.1.4.1.10829.6.1Model name of this product.
.1.3.6.1.4.1.10829.7.2.1Description.
.1.3.6.1.4.1.10829.1Cyberstation alarm group witch contains information about the last alarm sent out as a trap.
.1.3.6.1.4.1.10829.4Group for items that may be common to more than one product.
.1.3.6.1.4.1.10829.5Group for items specific to a product or family of products. Children of this node will be product families.
.1.3.6.1.4.1.10829.6Similiar to MIB-II system group, except for Andover Controls specific information about the device.
More MIBs from Andover Controls
Browse all Andover ControlsMIBs →The ACC-NC-ALARM-MIB facilitates SNMP-based monitoring of alarm states and notifications generated by Andover Controls Continuum building automation controllers. It maps proprietary hardware alarm conditions into standard MIB objects to enable centralized fault detection and event logging within network management systems.
The ACC-NOTIFICATION-MIB configures remote parameters for the ACC NetController software to control the generation and transmission of SNMP traps and notifications. This module manages the operational behavior of alert mechanisms rather than monitoring specific hardware performance metrics or traffic counters.