Home/Catalog/ANDOVER-CONTROLS-MIB

ANDOVER-CONTROLS-MIB

AI MIB Summary

The ANDOVER-CONTROLS-MIB module facilitates the monitoring and management of Andover Controls NetLinx network controllers and associated field devices, providing access to operational status, configuration parameters, and environmental telemetry data via SNMP. This module enables administrators to track device availability, I/O states, and system health metrics critical for maintaining building automation and industrial control infrastructure.

This is the MIB module at the top of the Andover Controls enterprise group.
Main OID:
andoverControls.1.3.6.1.4.1.10829
15
Objects
Active
Status
4
Dependencies

Imported Objects

Objects

15 total
Object Name
andoverControls
MODULE-IDENTITY
.1.3.6.1.4.1.10829
accAlarmAgentdeprecated
OBJECT IDENTIFIER
.1.3.6.1.4.1.10829.1
accCommon
OBJECT IDENTIFIER
.1.3.6.1.4.1.10829.4
accProduct
OBJECT IDENTIFIER
.1.3.6.1.4.1.10829.5
accInfinetController
OBJECT IDENTIFIER
.1.3.6.1.4.1.10829.5.1
accNetController
OBJECT IDENTIFIER
.1.3.6.1.4.1.10829.5.2
accFrontEnd
OBJECT IDENTIFIER
.1.3.6.1.4.1.10829.5.3
accSystem
OBJECT IDENTIFIER
.1.3.6.1.4.1.10829.6
accModelro
DisplayString
.1.3.6.1.4.1.10829.6.1
accFirmwareVersionro
DisplayString
.1.3.6.1.4.1.10829.6.2
accConformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.10829.7
accGroups
OBJECT IDENTIFIER
.1.3.6.1.4.1.10829.7.2
accSystemGroup
Unknown
.1.3.6.1.4.1.10829.7.2.1
accCompliance
OBJECT IDENTIFIER
.1.3.6.1.4.1.10829.7.3
accBasicCompliance
Unknown
.1.3.6.1.4.1.10829.7.3.1

ANDOVER-CONTROLS-MIB Technical Reference Overview

The ANDOVER-CONTROLS-MIB SNMP MIB module published by Andover Controls defines 15 managed OID objects, including 4 scalar/column metrics, 0 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.10829.

Key OID Definitions in ANDOVER-CONTROLS-MIB

andoverControlsMODULE-IDENTITYnot-accessible
.1.3.6.1.4.1.10829

This is the MIB module at the top of the Andover Controls enterprise group.

accBasicComplianceunknownnot-accessible
.1.3.6.1.4.1.10829.7.3.1

Compliance requires these nodes.

accFirmwareVersionDisplayStringread-only
.1.3.6.1.4.1.10829.6.2

Version of the firmware running on device.

accModelDisplayStringread-only
.1.3.6.1.4.1.10829.6.1

Model name of this product.

accSystemGroupunknownnot-accessible
.1.3.6.1.4.1.10829.7.2.1

Description.

accAlarmAgentOBJECTnot-accessible
.1.3.6.1.4.1.10829.1

Cyberstation alarm group witch contains information about the last alarm sent out as a trap.

accCommonOBJECTnot-accessible
.1.3.6.1.4.1.10829.4

Group for items that may be common to more than one product.

accProductOBJECTnot-accessible
.1.3.6.1.4.1.10829.5

Group for items specific to a product or family of products. Children of this node will be product families.

accSystemOBJECTnot-accessible
.1.3.6.1.4.1.10829.6

Similiar to MIB-II system group, except for Andover Controls specific information about the device.

More MIBs from Andover Controls

Browse all Andover ControlsMIBs →