ACC-NOTIFICATION-MIB
The ACC-NOTIFICATION-MIB configures remote parameters for the ACC NetController software to control the generation and transmission of SNMP traps and notifications. This module manages the operational behavior of alert mechanisms rather than monitoring specific hardware performance metrics or traffic counters.
Imported Objects
Objects
16 total| Object Name |
|---|
accNotificationMIB MODULE-IDENTITY .1.3.6.1.4.1.10829.4.1 |
accNotifyObjects OBJECT IDENTIFIER .1.3.6.1.4.1.10829.4.1.1 |
accNotifyList OBJECT IDENTIFIER .1.3.6.1.4.1.10829.4.1.1.1 |
accNotifyNumberro Integer32 .1.3.6.1.4.1.10829.4.1.1.1.1 |
accNotifyTable SEQUENCE OF AccNotifyEntry .1.3.6.1.4.1.10829.4.1.1.1.2 |
accNotifyEntry AccNotifyEntry .1.3.6.1.4.1.10829.4.1.1.1.2.1 |
notifyIndexro Unsigned32 .1.3.6.1.4.1.10829.4.1.1.1.2.1.1 |
notifyAddressrw IpAddress .1.3.6.1.4.1.10829.4.1.1.1.2.1.2 |
notifyTyperw Enumeration .1.3.6.1.4.1.10829.4.1.1.1.2.1.3 |
notifyStorageTypero StorageType (SNMPv2-TC) .1.3.6.1.4.1.10829.4.1.1.1.2.1.4 |
notifyRowStatusrw Enumeration .1.3.6.1.4.1.10829.4.1.1.1.2.1.5 |
accNotifyConformance OBJECT IDENTIFIER .1.3.6.1.4.1.10829.4.1.3 |
accNotifyCompliances OBJECT IDENTIFIER .1.3.6.1.4.1.10829.4.1.3.1 |
accNotifyBasicCompliance Unknown .1.3.6.1.4.1.10829.4.1.3.1.1 |
accNotifyGroups OBJECT IDENTIFIER .1.3.6.1.4.1.10829.4.1.3.2 |
accNotifyGroup Unknown .1.3.6.1.4.1.10829.4.1.3.2.1 |
ACC-NOTIFICATION-MIB Technical Reference Overview
The ACC-NOTIFICATION-MIB SNMP MIB module published by Andover Controls defines 16 managed OID objects, including 8 scalar/column metrics, 1 SNMP tables, and 0 trap/notification events anchored at base OID .1.3.6.1.4.1.10829.4.1. Key tabular structures include accNotifyTable.
Key OID Definitions in ACC-NOTIFICATION-MIB
.1.3.6.1.4.1.10829.4.1This MIB module defines MIB objects which provide mechanisms to remotely configure the parameters used by an ACC NetController software for the generation of notifications.
.1.3.6.1.4.1.10829.4.1.1.1.2This table is used to select management targets which should receive notifications, as well as the type of notification which should be sent to each selected management target.
.1.3.6.1.4.1.10829.4.1.3.1.1Module Compliance
.1.3.6.1.4.1.10829.4.1.3.2.1A collection of objects for selecting which management targets are used for generating notifications, and the type of notification to be generated for each selected management target.
.1.3.6.1.4.1.10829.4.1.1.1.1count of entries in the Notify Table
.1.3.6.1.4.1.10829.4.1.1.1.2.1An entry in this table selects a set of management targets which should receive notifications, as well as the type of notification which should be sent to each selected management target.
.1.3.6.1.4.1.10829.4.1.1.1.2.1.2This object contains an IP Address as the destination of a notification
.1.3.6.1.4.1.10829.4.1.1.1.2.1.1The locally arbitrary, but unique identifier associated with this accNotifyEntry.
.1.3.6.1.4.1.10829.4.1.1.1.2.1.5The status of this conceptual row. To set a field, a manager must set the this object to inActive(2), then do the set. After finish, change it to active(1).
.1.3.6.1.4.1.10829.4.1.1.1.2.1.4The storage type for this conceptual row.
.1.3.6.1.4.1.10829.4.1.1.1.2.1.3This object determines the type of notification to be generated. If the value of this object is none(0), then no messages will be generated. If the value of this object is trap(1), then any messages generated for selected rows will contain SNMPv2-Trap PDUs.
More MIBs from Andover Controls
Browse all Andover ControlsMIBs →The ACC-NC-ALARM-MIB facilitates SNMP-based monitoring of alarm states and notifications generated by Andover Controls Continuum building automation controllers. It maps proprietary hardware alarm conditions into standard MIB objects to enable centralized fault detection and event logging within network management systems.
The ANDOVER-CONTROLS-MIB module facilitates the monitoring and management of Andover Controls NetLinx network controllers and associated field devices, providing access to operational status, configuration parameters, and environmental telemetry data via SNMP. This module enables administrators to track device availability, I/O states, and system health metrics critical for maintaining building automation and industrial control infrastructure.