ALTEON-TRAP-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for ALTEON-TRAP-MIB.

20
Objects
Active
Status
3
Dependencies

Imported Objects

Objects

20 total
Object Name
IMPORTSA altSwPrimaryPowerSuppylFailure trap signifies that the primary power supply failed.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.1
altSwRedunPowerSuppylFailureA altSwRedunPowerSuppylFailure trap signifies that the redundant power supply failed.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.2
altSwDefGwUpA altSwDefGwUp trap signifies that the default gateway is alive.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.3
altSwDefGwDownA altSwDefGwDown trap signifies that the default gateway is down.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.4
altSwDefGwInServiceA altSwDefGwEnabled trap signifies that the default gateway is up and in service.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.5
altSwDefGwNotInServiceA altSwDefGwDisabled trap signifies that the default gateway is alive but not in service.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.6
altSwSlbRealServerUpA altSwSlbRealServerUp trap signifies that the real server is up and operational.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.7
altSwSlbRealServerDownA altSwSlbRealServerDown trap signifies that the real server is down and out of service.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.8
altSwSlbRealServerMaxConnReachedA altSwSlbRealServerMaxConnReached trap signifies that the real server has reached maximum connections.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.9
altSwSlbBkupRealServerActA altSwSlbBkupRealServerAct trap signifies that the backup real server is activated due to availablity of the primary real server.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.10
altSwSlbBkupRealServerDeactA altSwSlbBkupRealServerDeact trap signifies that the backup real server is deactivated due to the primary real server is available.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.11
altSwSlbBkupRealServerActOverflowA altSwSlbBkupRealServerActOverflow trap signifies that the backup real server is deactivated due to the primary real server is overflowed.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.12
altSwSlbBkupRealServerDeactOverflowA altSwSlbBkupRealServerDeactOverflow trap signifies that the backup real server is deactivated due to the primary real server is out from overflow situation.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.13
altSwSlbFailoverStandbyA altSwSlbFailoverStandby trap signifies that the switch is now a standby switch.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.14
altSwSlbFailoverActiveA altSwSlbFailoverActive trap signifies that the switch is now an active switch.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.15
altSwSlbFailoverSwitchUpA altSwSlbFailoverSwitchUp trap signifies that the failover switch is alive.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.16
altSwSlbFailoverSwitchDownA altSwSlbFailoverSwitchDown trap signifies that the failover switch is down.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.17
altSwfltFilterFiredA altSwfltFilterFired trap signifies that the packet received on a switch port matches the filter rule.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.18
altSwSlbRealServerServiceUpA altSwSlbRealServerServiceUp trap signifies that the service port of the real server is up and operational.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.19
altSwSlbRealServerServiceDownA altSwSlbRealServerServiceDown trap signifies that the service port of the real server is down and out of service.
TRAP-TYPE
.1.3.6.1.4.1.1872.2.1.13.0.20