Home/Catalog/AIXIRB-MIB

AIXIRB-MIB

AI MIB Summary

The AIXIRB-MIB module facilitates the monitoring and management of TCP options and passive/extended link configurations on AIX-based systems utilizing the SLC (System Link Control) framework. It exposes specific metrics for TCP extension parameters and link state settings to enable granular troubleshooting of network interface behavior and protocol negotiation on IBM AIX servers.

SLC MIB for misc. TCP options and passive/extended link settings
Main OID:
aiXirb.1.3.6.1.4.1.539.16.5
19
Objects
Active
Status
1
Dependencies

Imported Objects

Objects

19 total
Object Name
aii
OBJECT IDENTIFIER
.1.3.6.1.4.1.539
aiSystemOID
OBJECT IDENTIFIER
.1.3.6.1.4.1.539.2
aiSLC2
OBJECT IDENTIFIER
.1.3.6.1.4.1.539.16
aiXirbSLC MIB for misc. TCP options and passive/extended link settings
MODULE-IDENTITY
.1.3.6.1.4.1.539.16.5
aiXirbSystem
OBJECT IDENTIFIER
.1.3.6.1.4.1.539.16.5.1
aiXirbTcp
OBJECT IDENTIFIER
.1.3.6.1.4.1.539.16.5.2
aiXirbTcpWindowSizeDefault window size for TCP connections. Current connections will maintain their current window sizes, but new connections will use the updated window size.rw
Enumeration
.1.3.6.1.4.1.539.16.5.2.1
aiXirbTcpSendAheadIndicates whether or not TCP connections wait for data acknowledgment before sending more data (if disabled (1)), or send the maximum TCP window size before requiring data to be acknowledged (if enabled (2)).rw
Enumeration
.1.3.6.1.4.1.539.16.5.2.2
aiXirbX25
OBJECT IDENTIFIER
.1.3.6.1.4.1.539.16.5.3
aiXirbBx25CallDownIf set to off(2), a passive link will stay up after all calls are disconnected. If set to on(1), a passive link will drop and go into DMLOCK (see aiXirbBx25DMlock below) when all the incomming calls are terminated. This object is meaningful only when aiLinkX25LinkMode is set to passive(2) on a given linkrw
Enumeration
.1.3.6.1.4.1.539.16.5.3.1
aiXirbBx25DMlockThe number of seconds to wait for after a link has gone inactive before allowing an outgoing call to attemp to bring up the link. Any outgoing call attempts will be rejected until the DMLOCK timer expires and the passive link returns to the standby mode. This object is meaningful only when aiLinkX25LinkMode is set to passive(2) on a given linkrw
INTEGER
.1.3.6.1.4.1.539.16.5.3.2
aiXirbBx25LinkUpThe number of seconds to wait for a passive link to become active. This object is meaningful only when aiLinkX25LinkMode is set to passive(2) on a given linkrw
INTEGER
.1.3.6.1.4.1.539.16.5.3.3
aiXirbCpuStats
OBJECT IDENTIFIER
.1.3.6.1.4.1.539.16.5.4
aiXirbCpuStatsCurrentThis indicates the average of percentage CPU utilization during last 60 secondsro
INTEGER
.1.3.6.1.4.1.539.16.5.4.1
aiXirbCpuStatsMaxThis shows the maximum percentage CPU utilization during last 24 hours. This value is calculated from the average CPU utilization information which is found every 60 seconds.ro
INTEGER
.1.3.6.1.4.1.539.16.5.4.2
aiXirbCpuStatsResetThis resets the CPU utilization statisticsrw
Enumeration
.1.3.6.1.4.1.539.16.5.4.3
aiXirbEthernet
OBJECT IDENTIFIER
.1.3.6.1.4.1.539.16.5.5
aiXirbPpc10BaseTDetermines whether the front panel 10 BaseT interface is enabled or not on - to enable the 10 BaseT interface off - to disable the 10 BaseT interfacerw
Enumeration
.1.3.6.1.4.1.539.16.5.5.1
aiXirb10BaseTDuplexFor AIwan only. Setting this to full(1) puts the AIwan Ethernet interface into Full Duplex mode (sends and receives simultaneously). Setting this to half(2) puts the AIwan Ethernet interface into Half Duplex mode (sends OR receives, but not simultaneously -- this means that collisions are possible). In general, half duplex works fine for switches AND hubs, whereas full duplex mode should only be used with switches or other interfaces that are full duplex capable.rw
Enumeration
.1.3.6.1.4.1.539.16.5.5.2

More MIBs from Applied Innovation

Browse all Applied InnovationMIBs →
AISPY-MIB

Standard SNMP MIB module defining data structures for AISPY-MIB.

397 objects→
AI198CLC-MIB

The AI198CLC-MIB facilitates SNMP-based monitoring and management of Series 1 Common Logic Controllers (CLCs), enabling the retrieval of operational status, alarm states, and performance counters for these industrial automation devices.

217 objects→
AIX1-MIB

Standard SNMP MIB module defining data structures for AIX1-MIB.

176 objects→
AIMIB

The AIMIB module facilitates SNMP-based monitoring and management of Common Logic Controller (CLC) hardware, providing access to operational status, configuration parameters, and performance counters specific to the controller's logic execution and I/O subsystems.

131 objects→
STREAMS-MIB

STREAMS-MIB monitors the configuration and operational status of STREAMS subsystems, specifically tracking pipe instances, module bindings, and data flow states within Unix-based operating systems. This module enables administrators to verify the integrity of STREAMS drivers and multiplexers by observing interface counters, error conditions, and resource allocation metrics.

119 objects→
AIBADGER-MIB

The AIBADGER-MIB module provides SNMP management interfaces for AI's AIBadger hardware or software platform, exposing specific operational metrics such as system status, resource utilization, and device health counters. This module enables network administrators to monitor the performance and availability of AIBadger instances within an infrastructure environment.

113 objects→