AISLC-MIB
AI MIB Summary
AISLC-MIB provides SNMP management capabilities for Alcatel-Lucent Smart Line Cards (SLC), enabling the monitoring of interface status, traffic counters, and hardware health metrics such as temperature and power supply states. This module facilitates granular visibility into the operational performance and fault conditions of specific line card hardware within carrier-grade switching and routing platforms.
The MIB Module for Smart Line Cards (SLC)
Main OID:
aiSLC.1.3.6.1.4.1.539.10
16
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
16 total| Object Name |
|---|
aii OBJECT IDENTIFIER .1.3.6.1.4.1.539 |
aiSLCThe MIB Module for Smart Line Cards (SLC) MODULE-IDENTITY .1.3.6.1.4.1.539.10 |
aiSLCSystem OBJECT IDENTIFIER .1.3.6.1.4.1.539.10.1 |
aislcAdminStatusConfigured boot status of the
card. A write of boot(2)when this
object is in up(1) state will
cause the SLC to reboot. Any
other write will have no effect.
This may not yet be the
operational state of the SLC.
The current operational state of
the SLC is available as
aislcOperStatus below.rw Enumeration .1.3.6.1.4.1.539.10.1.1 |
aislcAdminPushA write of push(2) to this object informs the
SLC that the management station is done with a
group of related set requests. The SLC will save
to novolatile memory any unsaved values. The use
of this feature by the management station is
OPTIONAL. The SLC will save to nonvolatile memory
periodically, and upon the occurence of various
events, even if the management station never writes
to this object.rw Enumeration .1.3.6.1.4.1.539.10.1.2 |
aislcOperBaseportThe baseport of the SLC. This
is the lowest-numbered
backplane Time Division
Subchannel assigned to this
SLC.ro INTEGER .1.3.6.1.4.1.539.10.1.3 |
aislcLastConfigTimeThe timestamp of the last
configuration or inventory
change in the SLC. This value
should be set to the value of
sysUpTime at boot time.
Additionaly, this value should
be updated when a user changes
the configuration or when any
new hardware is detected that
would effect variables in the
supported MIBs.ro TimeTicks (SNMPv2-SMI) .1.3.6.1.4.1.539.10.1.4 |
aislcAdminResetAlarmA write of reset(2) to this object informs the SLC
that the management station wishes to reset the board
alarm level for the SLC to the NORMAL level. The use
of this feature by the management station is OPTIONAL.
The SLC will reset the alarm status of the SLC to a
normal alarm status. Used to reset the alarm status
of the SLC after marking an enabled link that is down
as dormant. A get of this object will return the
current board level alarm state, either normal(1) or
linkdown(3).rw Enumeration .1.3.6.1.4.1.539.10.1.5 |
aislcFirmwareVersionThe version of the firmware currently executing on the
SLC. This is in the format xxx.yyy[.zzz] where xxx,
yyy, and zzz are 1 to 3 digit numbers and the third
field, zzz, is optional.ro DisplayString .1.3.6.1.4.1.539.10.1.6 |
aislcProductNameThe name of the product, such as AI296 or AI193-FT.ro DisplayString .1.3.6.1.4.1.539.10.1.7 |
aislcRomIdImageIdThe image identifier (ROM ID) string of the firmware
currently executing on the SLC.ro DisplayString .1.3.6.1.4.1.539.10.1.8 |
aislcRomIdTimeDateThis is the image build time and date. The DateAndTime
type is a structured OCTET STRING, defined in v2-tc.my
(SNMPv2 Textual Conventions).ro DateAndTime (SNMPv2-TC) .1.3.6.1.4.1.539.10.1.9 |
aislcRomIdSelFeatTableA table of selectable features in this firmware image.
If there are no selectable features, this table is
empty. SEQUENCE OF AislcRomIdSelFeatTableEntry .1.3.6.1.4.1.539.10.1.10 |
aislcRomIdSelFeatTableEntryInformation about a particular selectable feature. AislcRomIdSelFeatTableEntry .1.3.6.1.4.1.539.10.1.10.1 |
aislcRomIdSelFeatNameThe name of the selectable feature for this entry.ro DisplayString (SNMPv2-TC) .1.3.6.1.4.1.539.10.1.10.1.1 |
aislcRomIdSelFeatEnabledWhether or not this selectable feature is enabled. The
TruthValue syntax defines values of true(1) and
false(2).ro TruthValue (SNMPv2-TC) .1.3.6.1.4.1.539.10.1.10.1.2 |