Home/Catalog/ACS8000-MIB

ACS8000-MIB

AI MIB Summary

The ACS8000-MIB module provides SNMP management extensions for ABB ACS8000 series industrial AC drives, enabling the monitoring of operational parameters such as motor speed, torque, DC bus voltage, and drive fault states.

This module defines the MIB extensions to ACS80xx products.
Main OID:
acs.1.3.6.1.4.1.10418.26
376
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

376 total
Object Name
acsThis module defines the MIB extensions to ACS80xx products.
MODULE-IDENTITY
.1.3.6.1.4.1.10418.26
SNMPv2-SMIThis module defines the MIB extensions to ACS80xx products.
Unknown
.1.3.6.1.4.1.10418.26
acsProducts
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.1
acs8048
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.1.1
acs8032
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.1.2
acs8016
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.1.3
acs8008
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.1.4
acs808
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.1.5
acs804
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.1.6
acs802
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.1.7
acsManagement
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.2
acsAppliance
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.2.1
acsHostNameThe appliance namero
DisplayString ( SIZE
.1.3.6.1.4.1.10418.26.2.1.1
acsProductModelThe appliance product modelro
DisplayString ( SIZE
.1.3.6.1.4.1.10418.26.2.1.2
acsPartNumberThe part number of this appliance as shown on the label attached or imprinted on the appliance.ro
DisplayString ( SIZE
.1.3.6.1.4.1.10418.26.2.1.3
acsSerialNumberThe serial number of this appliance as shown on the label attached or imprinted on the appliance.ro
DisplayString ( SIZE
.1.3.6.1.4.1.10418.26.2.1.4
acsEIDNumberThe electronic ID number (EID) of this appliance as shown on the label attached or imprinted on the appliance.ro
DisplayString ( SIZE
.1.3.6.1.4.1.10418.26.2.1.5
acsBootcodeVersionThe version of the bootcode of this appliance.ro
DisplayString ( SIZE
.1.3.6.1.4.1.10418.26.2.1.6
acsFirmwareVersionThe version of the firmware of this appliance.ro
DisplayString ( SIZE
.1.3.6.1.4.1.10418.26.2.1.7
acsPowerSupplyIt gives information about Power Supply of this appliance
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.2.1.8
acsPowerSupplyNumberNumber of the power supplies of this appliancero
Integer32
.1.3.6.1.4.1.10418.26.2.1.8.1
acsPowerSupplyStatePw1State of the first power supplyro
PowerSupplyState
.1.3.6.1.4.1.10418.26.2.1.8.2
acsPowerSupplyStatePw2State of the second power supplyro
PowerSupplyState
.1.3.6.1.4.1.10418.26.2.1.8.3
acsRebootA set value of reboot(2) will reboot the appliance. noAction(1) = always returned in a GET. Does nothing if SET. reboot(2) = when SET the appliance immediately reboots.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.1.9
acsSessions
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.2.2
acsActiveSessionsNumberOfSessionNumber of active sessions.ro
Integer32
.1.3.6.1.4.1.10418.26.2.2.1
acsActiveSessionsTableThis table contains the list of active sessions.
SEQUENCE OF AcsActiveSessionsTableEntry
.1.3.6.1.4.1.10418.26.2.2.2
acsActiveSessionsTableEntryeach entry has the information about the active session
AcsActiveSessionsTableEntry
.1.3.6.1.4.1.10418.26.2.2.2.1
acsActiveSessionsTableIndexA unique index representing an entry in this table.ro
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.10418.26.2.2.2.1.1
acsActiveSessionsTableUserThe name of the user that opens this session.ro
DisplayString ( SIZE
.1.3.6.1.4.1.10418.26.2.2.2.1.2
acsActiveSessionsTableGroupThe name of the group that the user belongs to.ro
DisplayString ( SIZE
.1.3.6.1.4.1.10418.26.2.2.2.1.3
acsActiveSessionsTableTypeThe session type.ro
DisplayString ( SIZE
.1.3.6.1.4.1.10418.26.2.2.2.1.4
acsActiveSessionsTableConnectionConnection type.ro
DisplayString ( SIZE
.1.3.6.1.4.1.10418.26.2.2.2.1.5
acsActiveSessionsTableSessionTimeTime of the sessionro
DisplayString ( SIZE
.1.3.6.1.4.1.10418.26.2.2.2.1.6
acsActiveSessionsTableFromThe source IP address of the session.ro
DisplayString ( SIZE
.1.3.6.1.4.1.10418.26.2.2.2.1.7
acsActiveSessionsTableKillA set value of killSession(2) will kill the session. noAction(1) = always returned in a GET. Does nothing if SET. killSession(2)= when SET the appliance immediately kills the session.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.2.2.1.8
acsSerialPort
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.2.3
acsSerialPortNumberOfPortsNumber of Serial Ports (physical serial port plus Aux Port.ro
Integer32
.1.3.6.1.4.1.10418.26.2.3.1
acsSerialPortTableThis table contains information about serial ports.
SEQUENCE OF AcsSerialPortTableEntry
.1.3.6.1.4.1.10418.26.2.3.2
acsSerialPortTableEntryeach entry has the information about specific serial port.
AcsSerialPortTableEntry
.1.3.6.1.4.1.10418.26.2.3.2.1
acsSerialPortTableNumberA unique index representing an entry in this table. It is the number of the serial port. For AUX port, the number will be the number of physical serial ports plus 1.ro
Integer32
.1.3.6.1.4.1.10418.26.2.3.2.1.1
acsSerialPortTableDeviceNameThe associated device name for the serial port.ro
DisplayString
.1.3.6.1.4.1.10418.26.2.3.2.1.2
acsSerialPortTableStatusThe status of the serial port: disabled(1) = it was configured as disable. idle(2) = there is not any session opened in this port. inUse(3) = there is session(s) opened in this port.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.3.2.1.3
acsSerialPortTableNameName associated with this serial port.ro
DisplayString
.1.3.6.1.4.1.10418.26.2.3.2.1.4
acsSerialPortTableProfileConfigured profile for this serial port.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.3.2.1.5
acsSerialPortTablePinOutRJ45 Pin-out configured for this serial port.ro
SerialPortPinOut
.1.3.6.1.4.1.10418.26.2.3.2.1.6
acsSerialPortTableComSpeedSpeed configured for this serial port.ro
SerialPortSpeed
.1.3.6.1.4.1.10418.26.2.3.2.1.7
acsSerialPortTableComParityParity configured for this serial port.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.3.2.1.8
acsSerialPortTableComDataSizeData Size configured for this serial port.ro
Integer32
.1.3.6.1.4.1.10418.26.2.3.2.1.9
acsSerialPortTableComStopBitsNumber of Stop Bits configured for this serial port.ro
Integer32
.1.3.6.1.4.1.10418.26.2.3.2.1.10
acsSerialPortTableComFlowControlFlow Control configured for this serial port.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.3.2.1.11
acsSerialPortTableSignalStateDTRState of the DTR RS-232C signal.ro
SerialPortSignalState
.1.3.6.1.4.1.10418.26.2.3.2.1.12
acsSerialPortTableSignalStateDCDState of the DCD RS-232C signal.ro
SerialPortSignalState
.1.3.6.1.4.1.10418.26.2.3.2.1.13
acsSerialPortTableSignalStateRTSState of the RTS RS-232C signal.ro
SerialPortSignalState
.1.3.6.1.4.1.10418.26.2.3.2.1.14
acsSerialPortTableSignalStateCTSState of the CTS RS-232C signal.ro
SerialPortSignalState
.1.3.6.1.4.1.10418.26.2.3.2.1.15
acsSerialPortTableTxBytesThe number of transmited bytes by the serial port.ro
Integer32
.1.3.6.1.4.1.10418.26.2.3.2.1.16
acsSerialPortTableRxBytesThe number of received bytes by the serial port.ro
Integer32
.1.3.6.1.4.1.10418.26.2.3.2.1.17
acsSerialPortTableFrameErrorThe number of frame error detected in the serial port.ro
Integer32
.1.3.6.1.4.1.10418.26.2.3.2.1.18
acsSerialPortTableParityErrorThe number of parity error detected in the serial port.ro
Integer32
.1.3.6.1.4.1.10418.26.2.3.2.1.19
acsSerialPortTableBreakThe number of break detected in the serial port.ro
Integer32
.1.3.6.1.4.1.10418.26.2.3.2.1.20
acsSerialPortTableOverrunThe number of overrun error detected in the serial port.ro
Integer32
.1.3.6.1.4.1.10418.26.2.3.2.1.21
acsPowerMgmt
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.2.5
acsPowerMgmtNumSerialPortsThe number of Serial Ports that has PDU connected on the appliance.ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.1
acsPowerMgmtSerialTableInformation about each serial port thas has PDU connect.
SEQUENCE OF AcsPowerMgmtSerialTableEntry
.1.3.6.1.4.1.10418.26.2.5.2
acsPowerMgmtSerialTableEntryInformation about each serial port thas has PDU connect.
AcsPowerMgmtSerialTableEntry
.1.3.6.1.4.1.10418.26.2.5.2.1
acsPowerMgmtSerialTableIndexThe index of the register.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.2.1.1
acsPowerMgmtSerialTablePortNumberThe number of the serial port when the PDU is connected.ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.2.1.2
acsPowerMgmtSerialTableDeviceNameThe device name of this serial port.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.2.1.3
acsPowerMgmtSerialTableNumberPDUsTotal number of units connected in this serial port.ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.2.1.4
acsPowerMgmtSerialTableNumberUPSTotal number of UPS devices connected to this serial port.ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.2.1.5
acsPowerMgmtPDUTableThis table contains the list of detected PDUs.
SEQUENCE OF AcsPowerMgmtPDUTableEntry
.1.3.6.1.4.1.10418.26.2.5.3
acsPowerMgmtPDUTableEntryeach entry has the information about the PDU.
AcsPowerMgmtPDUTableEntry
.1.3.6.1.4.1.10418.26.2.5.3.1
acsPowerMgmtPDUTablePortNumberNumber of serial port when the PDU is connected.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.3.1.1
acsPowerMgmtPDUTablePduIndexA PDU position in the chain.ro
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.3.1.2
acsPowerMgmtPDUTablePduIdPDU identification.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.3.1.3
acsPowerMgmtPDUTablePortNameName of serial port when the PDU is connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.3.1.4
acsPowerMgmtPDUTableModelModel of the PDU.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.3.1.5
acsPowerMgmtPDUTableVendorVendor of the PDU.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.3.1.6
acsPowerMgmtPDUTableFirmwareVersionVersion of the PDU firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.3.1.7
acsPowerMgmtPDUTableNumberOfOutletsNumber of outlets of the PDU.ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.8
acsPowerMgmtPDUTableCurrentNOSNumber of current sensors in the PDU.roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.9
acsPowerMgmtPDUTableCurrent1ValueCurrent of the sensor 1 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.)roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.10
acsPowerMgmtPDUTableCurrent1MaxMaximum current of the sensor 1 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value.rwobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.11
acsPowerMgmtPDUTableCurrent2ValueCurrent of the sensor 2 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.)roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.12
acsPowerMgmtPDUTableCurrent2MaxMaximum current of the sensor 2 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value.rwobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.13
acsPowerMgmtPDUTableCurrent3ValueCurrent of the sensor 3 in this PDU unit in AMP. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.)roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.14
acsPowerMgmtPDUTableCurrent3MaxMaximum current of the sensor 3 in this PDU unit in AMP. When the PDU does not have support for maximum value, the value will be 0. The value of this object is the actual current in AMP * 10. You need to translate the readed value (Ex. : value is 5, the current is 0.5 AMP.) Clear this value, set it with Zero value.rwobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.15
acsPowerMgmtPDUTableTemperatureNOSNumber of temperature sensors in the PDU.roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.16
acsPowerMgmtPDUTableTemperature1ValueTemperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.17
acsPowerMgmtPDUTableTemperature1MaxMaximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature.rwobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.18
acsPowerMgmtPDUTableTemperature2ValueTemperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.19
acsPowerMgmtPDUTableTemperature2MaxMaximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature.rwobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.20
acsPowerMgmtPDUTableTemperature3ValueTemperature of this PM unit in Celsius degrees. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.21
acsPowerMgmtPDUTableTemperature3MaxMaximum temperature detected in this PM unit in Celsius degrees. The value will be Zero when the PDU does not have support for maximum value. The value of this object is the actual temperature in degrees C * 10. You need to translate the readed value (Ex. : value is 240, the temperature is 24 Celsius.) If the temperature measurement is not installed this value will be 0. Valid values are 5 to 999 ( 0.5 to 99.9 Celsius). Set with Zero value to clear the max. temperature.rwobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.22
acsPowerMgmtPDUTableHumidityNOSNumber of humidity sensors in the PDU.roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.23
acsPowerMgmtPDUTableHumidity1ValueHumidity of this PM unit . If the humidity measurement is not installed this value will be 0.roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.24
acsPowerMgmtPDUTableHumidity1MaxMaximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature.rwobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.25
acsPowerMgmtPDUTableHumidity2ValueHumidity of this PM unit . If the humidity measurement is not installed this value will be 0.roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.26
acsPowerMgmtPDUTableHumidity2MaxMaximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature.rwobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.27
acsPowerMgmtPDUTableHumidity3ValueHumidity of this PM unit . If the humidity measurement is not installed this value will be 0.roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.28
acsPowerMgmtPDUTableHumidity3MaxMaximum humidity detected in this PM unit. If the humidity measurement is not installed or the PDU does not have support for maximum value this value will be 0. Set with Zero value to clear the max. temperature.rwobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.29
acsPowerMgmtPDUTableVoltageNOSNumber of voltage sensors in the PDU.roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.30
acsPowerMgmtPDUTableVoltage1ValueVoltage of this sensor in this PDU unit.roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.31
acsPowerMgmtPDUTableVoltage1MaxMaximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage.rwobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.32
acsPowerMgmtPDUTableVoltage2ValueVoltage of this sensor in this PDU unit.roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.33
acsPowerMgmtPDUTableVoltage2MaxMaximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage.rwobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.34
acsPowerMgmtPDUTableVoltage3ValueVoltage of this sensor in this PDU unit.roobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.35
acsPowerMgmtPDUTableVoltage3MaxMaximum voltage of this sensor in this PDU unit. Set with Zero value to clear the maximum voltage.rwobsolete
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.36
acsPowerMgmtPDUTableNumberOfPhasesNumber of phases of this PDU unit.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.3.1.37
acsPowerMgmtPDUTableNumberOfBanksNumber of banks of this PDU unit.ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.38
acsPowerMgmtPDUTableCurrentValueActual value of current sensor in this PDU.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.39
acsPowerMgmtPDUTableCurrentMaxMax detected value of current sensor in this PDU.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.40
acsPowerMgmtPDUTableCurrentMinMin detected value of current sensor in this PDU.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.41
acsPowerMgmtPDUTableCurrentAvgAverage value for current sensor in this PDU.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.42
acsPowerMgmtPDUTableCurrentResetReset max, min and avg values of current.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.3.1.43
acsPowerMgmtPDUTableVoltageTypeType of voltage values.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.3.1.44
acsPowerMgmtPDUTableVoltageValueActual value of voltage sensor in this PDU unit.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.45
acsPowerMgmtPDUTableVoltageMaxMax detected value of voltage sensor in this PDU unit.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.46
acsPowerMgmtPDUTableVoltageMinMin detected value of voltage sensor in this PDU unit.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.47
acsPowerMgmtPDUTableVoltageAvgAverage value for voltage sensor in this PDU unit.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.48
acsPowerMgmtPDUTableVoltageResetReset max, min and avg values of voltage.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.3.1.49
acsPowerMgmtPDUTablePowerTypeType of power consumption values.( W x 10 )ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.3.1.50
acsPowerMgmtPDUTablePowerValueActual value of power consumption in this PDU unit.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.51
acsPowerMgmtPDUTablePowerMaxMax detected value of power consumption in this PDU unit.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.52
acsPowerMgmtPDUTablePowerMinMin detected value of power consumption in this PDU unit.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.53
acsPowerMgmtPDUTablePowerAvgAverage value for power consumption in this PDU unit.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.54
acsPowerMgmtPDUTablePowerResetReset max, min and avg values of power consumption.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.3.1.55
acsPowerMgmtPDUTablePowerFactorTypeType of power factor values.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.3.1.56
acsPowerMgmtPDUTablePowerFactorValueActual value of power factor in this PDU unit.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.57
acsPowerMgmtPDUTablePowerFactorMaxMax detected value of power factor in this PDU unit.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.58
acsPowerMgmtPDUTablePowerFactorMinMin detected value of power factor in this PDU unit.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.59
acsPowerMgmtPDUTablePowerFactorAvgAverage value for power factor in this PDU unit.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.60
acsPowerMgmtPDUTablePowerFactorResetReset max, min and avg values of power factor.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.3.1.61
acsPowerMgmtPDUTableAlarmShow the PDU alarm status.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.3.1.62
acsPowerMgmtPDUTableEnvSensorsNumber of environmental sensor in this PDU.ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.3.1.63
acsPowerMgmtTotalNumberOfOutletsNumber of outlets managed by the appliance.ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.4
acsPowerMgmtOutletsTableThis table contains the information about outlets.
SEQUENCE OF AcsPowerMgmtOutletsTableEntry
.1.3.6.1.4.1.10418.26.2.5.5
acsPowerMgmtOutletsTableEntryeach entry has the information about the outlet.
AcsPowerMgmtOutletsTableEntry
.1.3.6.1.4.1.10418.26.2.5.5.1
acsPowerMgmtOutletsTablePortNumberSerial Port number.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.5.1.1
acsPowerMgmtOutletsTablePduNumberIndex.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.5.1.2
acsPowerMgmtOutletsTableNumberNumber of the outlet in the PDU.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.5.1.3
acsPowerMgmtOutletsTableNameName of the outlet.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.5.1.4
acsPowerMgmtOutletsTableStatusStatus of the outlet.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.5.1.5
acsPowerMgmtOutletsTablePowerControlA set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to PDU. powerOff(3) = when SET the power Off command is sent to PDU. powerCycle(4)=when SET the power cycle command is sent to PDU. powerLock(5)= when SET the power lock command is sent to PDU. powerUnlock(6)=when SET the power unlock command is sent to PDU. The powerLock and powerUnlock are valid only for Cyclades-PM PDUsrw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.5.1.6
acsPowerMgmtOutletsTablePortNameSerial Port Name where the PDU is connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.5.1.7
acsPowerMgmtOutletsTablePduIdPDU identification.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.5.1.8
acsPowerMgmtNumberOfOutletGroupNumber of configured group of outlets.ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.6
acsPowerMgmtGroupTableThis table contains the information about group of outlets.
SEQUENCE OF AcsPowerMgmtGroupTableEntry
.1.3.6.1.4.1.10418.26.2.5.7
acsPowerMgmtGroupTableEntryeach entry has the information about group of outlets.
AcsPowerMgmtGroupTableEntry
.1.3.6.1.4.1.10418.26.2.5.7.1
acsPowerMgmtGroupTableIndexIndex of the group.ro
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.7.1.1
acsPowerMgmtGroupTableNameName of the group of outlets.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.7.1.2
acsPowerMgmtGroupTableStatusStatus of the group of outlet.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.7.1.3
acsPowerMgmtGroupTablePowerControlA set value of power*(2-6) will send command to PDU. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to PDU. powerOff(3) = when SET the power Off command is sent to PDU. powerCycle(4)=when SET the power cycle command is sent to PDU.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.7.1.4
acsPowerMgmtPhasesTableThis table contains data monitoring of each detected phase.
SEQUENCE OF AcsPowerMgmtPhasesTableEntry
.1.3.6.1.4.1.10418.26.2.5.8
acsPowerMgmtPhasesTableEntryeach entry has the data monitoring about phases.
AcsPowerMgmtPhasesTableEntry
.1.3.6.1.4.1.10418.26.2.5.8.1
acsPowerMgmtPhasesTablePortNumberNumber of serial port when the PDU is connected.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.8.1.1
acsPowerMgmtPhasesTablePduIndexA PDU position in the chain.ro
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.8.1.2
acsPowerMgmtPhasesTablePhaseIndexphase index in the PDU.ro
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.8.1.3
acsPowerMgmtPhasesTablePhaseNamephase name in the PDU.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.8.1.4
acsPowerMgmtPhasesTablePduIdPDU identification.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.8.1.5
acsPowerMgmtPhasesTablePortNameName of serial port when the PDU is connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.8.1.6
acsPowerMgmtPhasesTableCurrentValueActual value of current sensor in this phase.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.7
acsPowerMgmtPhasesTableCurrentMaxMax detected value of current sensor in this phase.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.8
acsPowerMgmtPhasesTableCurrentMinMin detected value of current sensor in this phase.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.9
acsPowerMgmtPhasesTableCurrentAvgAverage value for current sensor in this phase.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.10
acsPowerMgmtPhasesTableCurrentResetReset max, min and avg values of current.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.8.1.11
acsPowerMgmtPhasesTableVoltageTypeType of voltage values.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.8.1.12
acsPowerMgmtPhasesTableVoltageValueActual value of voltage sensor in this phase.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.13
acsPowerMgmtPhasesTableVoltageMaxMax detected value of voltage sensor in this phase.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.14
acsPowerMgmtPhasesTableVoltageMinMin detected value of voltage sensor in this phase.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.15
acsPowerMgmtPhasesTableVoltageAvgAverage value for voltage sensor in this phase.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.16
acsPowerMgmtPhasesTableVoltageResetReset max, min and avg values of voltage.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.8.1.17
acsPowerMgmtPhasesTablePowerTypeType of power consumption values.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.8.1.18
acsPowerMgmtPhasesTablePowerValueActual value of power consumption in this phase.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.19
acsPowerMgmtPhasesTablePowerMaxMax detected value of power consumption in this phase.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.20
acsPowerMgmtPhasesTablePowerMinMin detected value of power consumption in this phase.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.21
acsPowerMgmtPhasesTablePowerAvgAverage value for power consumption in this phase.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.22
acsPowerMgmtPhasesTablePowerResetReset max, min and avg values of power consumption.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.8.1.23
acsPowerMgmtPhasesTablePowerFactorTypeType of power factor values.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.8.1.24
acsPowerMgmtPhasesTablePowerFactorValueActual value of power factor in this phase.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.25
acsPowerMgmtPhasesTablePowerFactorMaxMax detected value of power factor in this phase.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.26
acsPowerMgmtPhasesTablePowerFactorMinMin detected value of power factor in this phase.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.27
acsPowerMgmtPhasesTablePowerFactorAvgAverage value for power factor in this phase.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.8.1.28
acsPowerMgmtPhasesTablePowerFactorResetReset max, min and avg values of power factor.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.8.1.29
acsPowerMgmtPhasesTableAlarmShow the phase alarm status.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.8.1.30
acsPowerMgmtBanksTableThis table contains data monitoring of each detected bank.
SEQUENCE OF AcsPowerMgmtBanksTableEntry
.1.3.6.1.4.1.10418.26.2.5.9
acsPowerMgmtBanksTableEntryeach entry has the data monitoring about bank.
AcsPowerMgmtBanksTableEntry
.1.3.6.1.4.1.10418.26.2.5.9.1
acsPowerMgmtBanksTablePortNumberNumber of serial port when the PDU is connected.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.9.1.1
acsPowerMgmtBanksTablePduIndexA PDU position in the chain.ro
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.9.1.2
acsPowerMgmtBanksTableBankIndexBank index in the PDU.ro
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.9.1.3
acsPowerMgmtBanksTableBankNameBank name in the PDU.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.9.1.4
acsPowerMgmtBanksTablePduIdPDU identification.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.9.1.5
acsPowerMgmtBanksTablePortNameName of serial port when the PDU is connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.9.1.6
acsPowerMgmtBanksTableCurrentValueActual value of current sensor in this bank.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.7
acsPowerMgmtBanksTableCurrentMaxMax detected value of current sensor in this bank.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.8
acsPowerMgmtBanksTableCurrentMinMin detected value of current sensor in this bank.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.9
acsPowerMgmtBanksTableCurrentAvgAverage value for current sensor in this bank.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.10
acsPowerMgmtBanksTableCurrentResetReset max, min and avg values of current.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.9.1.11
acsPowerMgmtBanksTableVoltageTypeType of voltage values.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.9.1.12
acsPowerMgmtBanksTableVoltageValueActual value of voltage sensor in this bank.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.13
acsPowerMgmtBanksTableVoltageMaxMax detected value of voltage sensor in this bank.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.14
acsPowerMgmtBanksTableVoltageMinMin detected value of voltage sensor in this bank.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.15
acsPowerMgmtBanksTableVoltageAvgAverage value for voltage sensor in this bank.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.16
acsPowerMgmtBanksTableVoltageResetReset max, min and avg values of voltage.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.9.1.17
acsPowerMgmtBanksTablePowerTypeType of power consumption values.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.9.1.18
acsPowerMgmtBanksTablePowerValueActual value of power consumption in this bank.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.19
acsPowerMgmtBanksTablePowerMaxMax detected value of power consumption in this bank.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.20
acsPowerMgmtBanksTablePowerMinMin detected value of power consumption in this bank.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.21
acsPowerMgmtBanksTablePowerAvgAverage value for power consumption in this bank.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.22
acsPowerMgmtBanksTablePowerResetReset max, min and avg values of power consumption.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.9.1.23
acsPowerMgmtBanksTablePowerFactorTypeType of power factor values.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.9.1.24
acsPowerMgmtBanksTablePowerFactorValueActual value of power factor in this bank.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.25
acsPowerMgmtBanksTablePowerFactorMaxMax detected value of power factor in this bank.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.26
acsPowerMgmtBanksTablePowerFactorMinMin detected value of power factor in this bank.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.27
acsPowerMgmtBanksTablePowerFactorAvgAverage value for power factor in this bank.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.9.1.28
acsPowerMgmtBanksTablePowerFactorResetReset max, min and avg values of power factor.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.9.1.29
acsPowerMgmtBanksTableAlarmShow the bank alarm status.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.9.1.30
acsPowerMgmtEnvMonTableThis table contains data monitoring of each detected environmental sensor.
SEQUENCE OF AcsPowerMgmtEnvMonTableEntry
.1.3.6.1.4.1.10418.26.2.5.10
acsPowerMgmtEnvMonTableEntryeach entry has the data monitoring about environmental sensors.
AcsPowerMgmtEnvMonTableEntry
.1.3.6.1.4.1.10418.26.2.5.10.1
acsPowerMgmtEnvMonTablePortNumberNumber of serial port when the PDU is connected.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.10.1.1
acsPowerMgmtEnvMonTablePduIndexA PDU position in the chain.ro
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.10.1.2
acsPowerMgmtEnvMonTableIndexenvmon sensor index.ro
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.10.1.3
acsPowerMgmtEnvMonTableNameenvmon sensor name.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.10.1.4
acsPowerMgmtEnvMonTablePduIdPDU identification.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.10.1.5
acsPowerMgmtEnvMonTablePortNameName of serial port when the PDU is connected.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.10.1.6
acsPowerMgmtEnvMonTableTypeThe type of environmental monitor.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.10.1.7
acsPowerMgmtEnvMonTableStatusStatus of digital sensors: Dry-Contact, Water level, Smoke sensor, Motion sensor, Door-Contact. For Door-Contact, normal(1) = closed, triggered(2) = opened.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.10.1.8
acsPowerMgmtEnvMonTableValueDetected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu.ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.10.1.9
acsPowerMgmtEnvMonTableMaxValueMax detected value for envmon sensors. Temperature: C x 10. Humidity: %. Air flow: afu.ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.10.1.10
acsPowerMgmtOutElecMonTableThis table contains the information about data monitoring of outlets.
SEQUENCE OF AcsPowerMgmtOutElecMonTableEntry
.1.3.6.1.4.1.10418.26.2.5.11
acsPowerMgmtOutElecMonTableEntryeach entry has the information about the outlet.
AcsPowerMgmtOutElecMonTableEntry
.1.3.6.1.4.1.10418.26.2.5.11.1
acsPowerMgmtOutElecMonTablePortNumberSerial Port number.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.11.1.1
acsPowerMgmtOutElecMonTablePduNumberIndex.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.11.1.2
acsPowerMgmtOutElecMonTableNumberNumber of the outlet in the PDU.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.11.1.3
acsPowerMgmtOutElecMonTableCurrentValueActual value of outlet current sensor.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.4
acsPowerMgmtOutElecMonTableCurrentMaxMax detected value of outlet current sensor.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.5
acsPowerMgmtOutElecMonTableCurrentMinMin detected value of outlet current sensor.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.6
acsPowerMgmtOutElecMonTableCurrentAvgAverage value for outlet current sensor.( A x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.7
acsPowerMgmtOutElecMonTableCurrentResetReset max, min and avertage values of outlet current.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.11.1.8
acsPowerMgmtOutElecMonTablePowerValueActual value of outlet power comsumption sensor.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.9
acsPowerMgmtOutElecMonTablePowerMaxMax detected value of outlet power comsumption sensor.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.10
acsPowerMgmtOutElecMonTablePowerMinMin detected value of outlet power comsumption sensor.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.11
acsPowerMgmtOutElecMonTablePowerAvgAverage value for outlet power comsumption sensor.( W x 10 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.12
acsPowerMgmtOutElecMonTablePowerResetReset max, min and avertage values of outlet power comsumption.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.11.1.13
acsPowerMgmtOutElecMonTableVoltageValueActual value of outlet voltage sensor.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.14
acsPowerMgmtOutElecMonTableVoltageMaxMax detected value of outlet voltage sensor.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.15
acsPowerMgmtOutElecMonTableVoltageMinMin detected value of outlet voltage sensor.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.16
acsPowerMgmtOutElecMonTableVoltageAvgAverage value for outlet voltage sensor.( V )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.17
acsPowerMgmtOutElecMonTableVoltageResetReset max, min and avertage values of outlet voltage.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.11.1.18
acsPowerMgmtOutElecMonTablePowerFactorValueActual value of outlet power-factor sensor.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.19
acsPowerMgmtOutElecMonTablePowerFactorMaxMax detected value of outlet power-factor sensor.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.20
acsPowerMgmtOutElecMonTablePowerFactorMinMin detected value of outlet power-factor sensor.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.21
acsPowerMgmtOutElecMonTablePowerFactorAvgAverage value for outlet power-factor sensor.( PF x 100 )ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.11.1.22
acsPowerMgmtOutElecMonTablePowerFactorResetReset max, min and avertage values of outlet power-factor.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.11.1.23
acsPowerMgmtOutElecMonTableAlarmShow the outlet alarm status.ro
Enumeration
.1.3.6.1.4.1.10418.26.2.5.11.1.24
acsPowerMgmtUPSTableThis table contains the list of detected UPSs.
SEQUENCE OF AcsPowerMgmtUPSTableEntry
.1.3.6.1.4.1.10418.26.2.5.12
acsPowerMgmtUPSTableEntryEach entry has the information about the UPS.
AcsPowerMgmtUPSTableEntry
.1.3.6.1.4.1.10418.26.2.5.12.1
acsPowerMgmtUPSTablePortNumberNumber of serial port when the UPS is connected.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.12.1.1
acsPowerMgmtUPSTableUpsIndexA UPS position in the chain.ro
InterfaceIndexOrZero (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.12.1.2
acsPowerMgmtUPSTableUpsIdUPS identification.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.3
acsPowerMgmtUPSTablePortNameName of serial port or IP address if network devicero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.4
acsPowerMgmtUPSTableModelModel of the UPS.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.5
acsPowerMgmtUPSTableVendorVendor of the UPS.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.6
acsPowerMgmtUPSTableFirmwareVersionVersion of the UPS firmware.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.7
acsPowerMgmtUPSTableAgentFirmwareVersionFirmware version of the agent card.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.8
acsPowerMgmtUPSTableSystemStatusSystem Status of the UPS.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.9
acsPowerMgmtUPSTableInputBlackOutCountThe number of occurrences, since the last reset, where the input was not qualified to provide power to the system.ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.12.1.10
acsPowerMgmtUPSTableInputBrownOutCountThe number of occurrences, since the last reset, where the system input voltage has fallen below a pre-determined threshold for a specified amount of time.ro
Integer32
.1.3.6.1.4.1.10418.26.2.5.12.1.11
acsPowerMgmtUPSTableInletAirTemperatureTemperature of the inlet air.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.12
acsPowerMgmtUPSTableNumberOutletGroupsThe number of Outlet Groups on this UPSro
Integer32
.1.3.6.1.4.1.10418.26.2.5.12.1.13
acsPowerMgmtUPSTableUPSSerialNumberSystem serial number.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.14
acsPowerMgmtUPSTableUPSManufactureDateManufacturing date of the system.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.15
acsPowerMgmtUPSTableAutoRestartDelayIf power is lost, the control will delay this amount of time after power is restored before restarting the unit.rw
Integer32
.1.3.6.1.4.1.10418.26.2.5.12.1.16
acsPowerMgmtUPSTableAutoRestartControlWhen set to enabled, the UPS will automatically restart the load when utility power is restored after a battery discharge.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.12.1.17
acsPowerMgmtUPSTableAudibleAlarmControlAudible alarm control.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.12.1.18
acsPowerMgmtUPSTableSilenceAlarmSilence audible alarm.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.12.1.19
acsPowerMgmtUPSTableInverterStateInverter on/off state.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.20
acsPowerMgmtUPSTableDCConverterStatusThe operating state of the dc converter.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.21
acsPowerMgmtUPSTableShutdownReasonThe reason for the most recent shutdown.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.22
acsPowerMgmtUPSTableUPSTopologyUPS Topology.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.23
acsPowerMgmtUPSTableBypassInverterInputConfigInput source configuration for the bypass and inverter.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.12.1.24
acsPowerMgmtUPSInputTableThis table contains the information about UPS inputs.
SEQUENCE OF AcsPowerMgmtUPSInputTableEntry
.1.3.6.1.4.1.10418.26.2.5.13
acsPowerMgmtUPSInputTableEntryeach entry has the information about the UPS inputs.
AcsPowerMgmtUPSInputTableEntry
.1.3.6.1.4.1.10418.26.2.5.13.1
acsPowerMgmtUPSInputTablePortNumberSerial Port number.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.13.1.1
acsPowerMgmtUPSInputTableUpsIndexIndex.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.13.1.2
acsPowerMgmtUPSInputTableFrequencyInput Frequency.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.13.1.3
acsPowerMgmtUPSInputTableRMSVoltageL1NRMS Voltage L1-N.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.13.1.4
acsPowerMgmtUPSInputTableRMSVoltageL1L2RMS Voltage L1L2.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.13.1.5
acsPowerMgmtUPSInputTableRMSVoltageL2NRMS Voltage L2N.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.13.1.6
acsPowerMgmtUPSInputTableRMSCurrentL1RMS Current for L1.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.13.1.7
acsPowerMgmtUPSInputTableRMSCurrentL2RMS Current for L2.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.13.1.8
acsPowerMgmtUPSInputTableMaxVoltageL1NInput Max Voltage measurement for Line L1-N since the last reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.13.1.9
acsPowerMgmtUPSInputTableMinVoltageL1NInput Min Voltage measurement for Line L1-N since the last reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.13.1.10
acsPowerMgmtUPSInputTableMaxVoltageL2NInput Max Voltage measurement for Line L2-N since the last reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.13.1.11
acsPowerMgmtUPSInputTableMinVoltageL2NInput Min Voltage measurement for Line L1-N since the last reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.13.1.12
acsPowerMgmtUPSInputTableNominalVoltageInput nominal voltage.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.13.1.13
acsPowerMgmtUPSInputTableNominalFrequencyInput nominal frequency.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.13.1.14
acsPowerMgmtUPSInputTableNominalCurrentInput nominal current.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.13.1.15
acsPowerMgmtUPSBypassTableThis table contains the information about UPS bypass.
SEQUENCE OF AcsPowerMgmtUPSBypassTableEntry
.1.3.6.1.4.1.10418.26.2.5.14
acsPowerMgmtUPSBypassTableEntryeach entry has the information about the UPS bypass.
AcsPowerMgmtUPSBypassTableEntry
.1.3.6.1.4.1.10418.26.2.5.14.1
acsPowerMgmtUPSBypassTablePortNumberSerial Port number.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.14.1.1
acsPowerMgmtUPSBypassTableUpsIndexIndex.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.14.1.2
acsPowerMgmtUPSBypassTableRMSVoltageL1NRMS Voltage L1N.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.14.1.3
acsPowerMgmtUPSBypassTableRMSVoltageL1L2RMS Voltage L1L2.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.14.1.4
acsPowerMgmtUPSBypassTableRMSVoltageL2NRMS Voltage L2N.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.14.1.5
acsPowerMgmtUPSBypassTableRMSCurrentRMS Current.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.14.1.6
acsPowerMgmtUPSBypassTableRMSCurrentL2RMS Current.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.14.1.7
acsPowerMgmtUPSBypassTableInputFrequencyBypass Input Frequency.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.14.1.8
acsPowerMgmtUPSBypassTableNominalVoltageBypass Nominal Voltage.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.14.1.9
acsPowerMgmtUPSBatteryTableThis table contains the information about UPS battery.
SEQUENCE OF AcsPowerMgmtUPSBatteryTableEntry
.1.3.6.1.4.1.10418.26.2.5.15
acsPowerMgmtUPSBatteryTableEntryeach entry has the information about the UPS bypass.
AcsPowerMgmtUPSBatteryTableEntry
.1.3.6.1.4.1.10418.26.2.5.15.1
acsPowerMgmtUPSBatteryTablePortNumberSerial Port number.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.15.1.1
acsPowerMgmtUPSBatteryTableUpsIndexIndex.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.15.1.2
acsPowerMgmtUPSBatteryTableDCBusVoltageDC Bus Voltagero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.3
acsPowerMgmtUPSBatteryTableTimeRemainingThe calculated available time on battery.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.4
acsPowerMgmtUPSBatteryTablePercentageChargeBattery Percentage Charge.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.5
acsPowerMgmtUPSBatteryTableChargeStatusBattery Charge Status.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.6
acsPowerMgmtUPSBatteryTableLowBatteryWarningTimeWhen battery time remaining falls to, or below, this value (minutes) the low battery alarm is activated.rw
INTEGER
.1.3.6.1.4.1.10418.26.2.5.15.1.7
acsPowerMgmtUPSBatteryTableTestResultThe outcome of the previous battery test.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.8
acsPowerMgmtUPSBatteryTableDCBusNominalVoltageBattery DC Bus Nominal Voltage.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.9
acsPowerMgmtUPSBatteryTableNominalBatteryCapacityNominal Battery Capacity.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.10
acsPowerMgmtUPSBatteryTableBatteryFloatVoltageBattery Float Voltage.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.11
acsPowerMgmtUPSBatteryTableBatteryCabinetTypeBattery Cabinet Type.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.12
acsPowerMgmtUPSBatteryTableBatteryNumberOfEBCNumber of Extended Battery Cabinets installed.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.13
acsPowerMgmtUPSBatteryTableBatteryRatingBattery Rating.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.14
acsPowerMgmtUPSBatteryTableBatteryDischargeTimeTime on battery operation for this dischargero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.15
acsPowerMgmtUPSBatteryTableBatteryChargeCompensatingBattery charge algorithm changed due to battery temperature.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.16
acsPowerMgmtUPSBatteryTableBatteryChargerStateBattery charger state.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.17
acsPowerMgmtUPSBatteryTableStartBatteryTestCommand to initate a manual battery test.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.15.1.18
acsPowerMgmtUPSBatteryTableBatteryStatusBattery Status.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.15.1.19
acsPowerMgmtUPSOutputTableThis table contains the information about UPS output.
SEQUENCE OF AcsPowerMgmtUPSOutputTableEntry
.1.3.6.1.4.1.10418.26.2.5.16
acsPowerMgmtUPSOutputTableEntryEach entry has the information about the UPS output.
AcsPowerMgmtUPSOutputTableEntry
.1.3.6.1.4.1.10418.26.2.5.16.1
acsPowerMgmtUPSOutputTablePortNumberSerial Port number.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.16.1.1
acsPowerMgmtUPSOutputTableUpsIndexIndex.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.16.1.2
acsPowerMgmtUPSOutputTableApparentPowerDC Bus Voltagero
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.3
acsPowerMgmtUPSOutputTableFrequencyOutput frequency.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.4
acsPowerMgmtUPSOutputTablePercentPowerThe system output power as a percentage of the rated capacity.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.5
acsPowerMgmtUPSOutputTablePercentPowerL1The system output power on line L1 as a percentage of the rated capacity.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.6
acsPowerMgmtUPSOutputTablePercentPowerL2The system output power on line L2 as a percentage of the rated capacity.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.7
acsPowerMgmtUPSOutputTablePowerThe sum total power of all system output phases.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.8
acsPowerMgmtUPSOutputTableRMSCurrentL1System output RMS current for line L1.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.9
acsPowerMgmtUPSOutputTableRMSCurrentL2System output RMS current for line L2.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.10
acsPowerMgmtUPSOutputTableRMSVoltageL1NThe system output RMS voltage.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.11
acsPowerMgmtUPSOutputTableRMSVoltageL2NThe system output RMS voltage.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.12
acsPowerMgmtUPSOutputTableRMSVoltageL1L2The system output RMS voltage.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.13
acsPowerMgmtUPSOutputOffDelayTurns the UPS output off after the number of seconds specified. When a value is written to this object the output will be turned off after the specified time has elapsed and the output will remain off.rw
INTEGER
.1.3.6.1.4.1.10418.26.2.5.16.1.14
acsPowerMgmtUPSOutputOnDelayTurns the UPS output on after the number of seconds specified. When a value is written to this object the output will be turned on after the specified time has elapsed.rw
INTEGER
.1.3.6.1.4.1.10418.26.2.5.16.1.15
acsPowerMgmtUPSOutputCycleDelayTurns the UPS off and then back on after the number of seconds specified. When a value is written to this object the output will turned off immediately and then turned back on after the specified time has elapsed.rw
INTEGER
.1.3.6.1.4.1.10418.26.2.5.16.1.16
acsPowerMgmtUPSOutputTableMaxVoltageL1The maximum system output voltage measurement for line 1 since the last reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.17
acsPowerMgmtUPSOutputTableMinVoltageL1The minimum system output voltage measurement for line 1 since the last reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.18
acsPowerMgmtUPSOutputTableMaxVoltageL2The maximum system output voltage measurement for line 21 since the last reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.19
acsPowerMgmtUPSOutputTableMinVoltageL2The minimum system output voltage measurement for line 2 since the last reset.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.20
acsPowerMgmtUPSOutputTableNominalVoltageThe nominal (or rated) system output voltage.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.21
acsPowerMgmtUPSOutputTablePowerNominalFrequencyThe nominal (or rated) system output frequency.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.22
acsPowerMgmtUPSOutputTablePowerApparentPowerRatingOutput apparent power rating.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.23
acsPowerMgmtUPSOutputTablePowerNominalPowerFactorThe nominal (or rated) system power factor.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.24
acsPowerMgmtUPSOutputTablePowerPowerFactorCorrectionThe state of the power factor correction circuitry of the system.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.25
acsPowerMgmtUPSOutputTablePowerL1The system output power on line 1.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.26
acsPowerMgmtUPSOutputTablePowerL2The system output power on line 2.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.27
acsPowerMgmtUPSOutputTableApparentPowerL1The system output apparent power on line 1.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.28
acsPowerMgmtUPSOutputTableApparentPowerL2The system output apparent power on line 2.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.16.1.29
acsPowerMgmtUPSEcoModeTableThis table contains the information about UPS ECO Mode.
SEQUENCE OF AcsPowerMgmtUPSEcoModeTableEntry
.1.3.6.1.4.1.10418.26.2.5.17
acsPowerMgmtUPSEcoModeTableEntryeach entry has the information about the UPS ECO Mode.
AcsPowerMgmtUPSEcoModeTableEntry
.1.3.6.1.4.1.10418.26.2.5.17.1
acsPowerMgmtUPSEcoModeTablePortNumberSerial Port number.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.17.1.1
acsPowerMgmtUPSEcoModeTableUpsIndexIndex.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.17.1.2
acsPowerMgmtUPSEcoModeTableStatusCurrent ECO Mode Status.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.17.1.3
acsPowerMgmtUPSEcoModeTableStateControlEnable or disable ECO mode.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.17.1.4
acsPowerMgmtUPSOutletGroupTableThis table contains the UPS Outlet Group Information.
SEQUENCE OF AcsPowerMgmtUPSOutletGroupTableEntry
.1.3.6.1.4.1.10418.26.2.5.18
acsPowerMgmtUPSOutletGroupTableEntryEach entry has the UPS outlet group information.
AcsPowerMgmtUPSOutletGroupTableEntry
.1.3.6.1.4.1.10418.26.2.5.18.1
acsPowerMgmtUPSOutletGroupTablePortNumberSerial Port number.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.18.1.1
acsPowerMgmtUPSOutletGroupTableUpsIndexIndex.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.18.1.2
acsPowerMgmtUPSOutletGroupTableNumberNumber of the outletgroup in the UPS.ro
InterfaceIndex (IF-MIB)
.1.3.6.1.4.1.10418.26.2.5.18.1.3
acsPowerMgmtUPSOutletGroupTableLabelUser-defined label for the outlet group.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.18.1.4
acsPowerMgmtUPSOutletGroupTableStateUser-defined label for the outlet group.ro
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.10418.26.2.5.18.1.5
acsPowerMgmtUPSOutletGroupTablePowerControlA set value of power(2-6) will send command to the UPS. noAction(1) = always returned in a GET. Does nothing if SET. powerOn(2) = when SET the power On command is sent to UPS. powerOff(3) = when SET the power Off command is sent to UPS. powerCycle(4)=when SET the power cycle command is sent to UPS.rw
Enumeration
.1.3.6.1.4.1.10418.26.2.5.18.1.6
acsTrapObject
OBJECT IDENTIFIER
.1.3.6.1.4.1.10418.26.2.6
ACS8000-MIB - SNMP MIB Reference | MIBs Explorer