Home/Catalog/AC-PM-ATM-MIB

AC-PM-ATM-MIB

AI MIB Summary

The AC-PM-ATM-MIB module enables Audiocodes devices to monitor Asynchronous Transfer Mode (ATM) interface performance counters and configure polling intervals or threshold alerts via SNMP. It provides specific data tables for ATM-related traffic metrics while utilizing a value of -1 to indicate unsupported parameters or intervals that have not yet been recorded.

The AC-PM-ATM MIB offers performance monitoring For the ATMrelated elements in Audiocodes' devices. The Configuration sub-tree is for configuring the interval Period length for the entire AC-PM-ATM MIB, and the different tables' thresholds. The Data sub-tree presents the tables of monitored elements. Note - for the entire MIB the value (-1) means the value Asked for is either not supported or currently not relevant (this is for when values asked for are for intervals not yet recorded.
Main OID:
acPMAtm.1.3.6.1.4.1.5003.10.12
45
Objects
Active
Status
1
Dependencies

Imported Objects

Objects

45 total
Object Name
audioCodes
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003
acRegistrations
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.7
acGeneric
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.8
acProducts
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9
acPerformance
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.10
acPMAtmThe AC-PM-ATM MIB offers performance monitoring For the ATMrelated elements in Audiocodes' devices. The Configuration sub-tree is for configuring the interval Period length for the entire AC-PM-ATM MIB, and the different tables' thresholds. The Data sub-tree presents the tables of monitored elements. Note - for the entire MIB the value (-1) means the value Asked for is either not supported or currently not relevant (this is for when values asked for are for intervals not yet recorded.
MODULE-IDENTITY
.1.3.6.1.4.1.5003.10.12
acPMAtmConfiguration
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.10.12.1
acPMAtmConfigurationPeriodLengthLength of monitoring intervals for entire MIB.Time is in minutes.rw
INTEGER
.1.3.6.1.4.1.5003.10.12.1.1
acPMAtmConfigurationResetTotalCountersTotal-Counters Reset. To reset the total counters, set the value of this object to resetTotalCounters(2).rw
Enumeration
.1.3.6.1.4.1.5003.10.12.1.2
acPMAtmCellAttributes
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.10.12.1.31
acPMAtmCellAttributesTxHighThresholdHigh threshold.rw
INTEGER
.1.3.6.1.4.1.5003.10.12.1.31.1
acPMAtmCellAttributesTxLowThresholdLow threshold.rw
INTEGER
.1.3.6.1.4.1.5003.10.12.1.31.2
acPMAtmCellAttributesRxHighThresholdHigh threshold.rw
INTEGER
.1.3.6.1.4.1.5003.10.12.1.31.3
acPMAtmCellAttributesRxLowThresholdLow threshold.rw
INTEGER
.1.3.6.1.4.1.5003.10.12.1.31.4
acPMAtmData
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.10.12.2
acPMAtmDataAcPMAtmTimeFromStartOfIntervalThe time in seconds since the start of the current interval. MIB specific.ro
INTEGER
.1.3.6.1.4.1.5003.10.12.2.1
acPMAtmCellTxTableAtm interface transmit cells per second.
SEQUENCE OF AcPMAtmCellTxEntry
.1.3.6.1.4.1.5003.10.12.2.21
acPMAtmCellTxEntry
AcPMAtmCellTxEntry
.1.3.6.1.4.1.5003.10.12.2.21.1
acPMAtmCellTxInterfaceAtm interface 0,1 and 2.
INTEGER
.1.3.6.1.4.1.5003.10.12.2.21.1.1
acPMAtmCellTxIntervalInterval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
INTEGER
.1.3.6.1.4.1.5003.10.12.2.21.1.2
acPMAtmCellTxAverageAverage value within the period time.ro
INTEGER (-1..2147483647)
.1.3.6.1.4.1.5003.10.12.2.21.1.3
acPMAtmCellTxMaxMaximum value within the period time.ro
INTEGER (-1..2147483647)
.1.3.6.1.4.1.5003.10.12.2.21.1.4
acPMAtmCellTxMinMinimum value within the period time.ro
INTEGER (-1..2147483647)
.1.3.6.1.4.1.5003.10.12.2.21.1.5
acPMAtmCellTxVolumeActivity volume.ro
Counter32
.1.3.6.1.4.1.5003.10.12.2.21.1.6
acPMAtmCellTxTimeBelowLowThresholdPercent of interval time for which gauge is below what was determined as the low threshold.ro
INTEGER (-1..100)
.1.3.6.1.4.1.5003.10.12.2.21.1.7
acPMAtmCellTxTimeBetweenThresholdsPercent of interval time for which gauge is above what was determined as the high threshold.ro
INTEGER (-1..100)
.1.3.6.1.4.1.5003.10.12.2.21.1.8
acPMAtmCellTxTimeAboveHighThresholdPercent of interval time for which gauge is between what were determined as the low and high thresholds.ro
INTEGER (-1..100)
.1.3.6.1.4.1.5003.10.12.2.21.1.9
acPMAtmCellTxFullDayAverageThe average of full 24 hours.ro
INTEGER (-1..2147483647)
.1.3.6.1.4.1.5003.10.12.2.21.1.10
acPMAtmCellRxTableAtm interface recieve cells per second.
SEQUENCE OF AcPMAtmCellRxEntry
.1.3.6.1.4.1.5003.10.12.2.22
acPMAtmCellRxEntry
AcPMAtmCellRxEntry
.1.3.6.1.4.1.5003.10.12.2.22.1
acPMAtmCellRxInterfaceAtm interface 0,1 and 2.
INTEGER
.1.3.6.1.4.1.5003.10.12.2.22.1.1
acPMAtmCellRxIntervalInterval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
INTEGER
.1.3.6.1.4.1.5003.10.12.2.22.1.2
acPMAtmCellRxAverageAverage value within the period time.ro
INTEGER (-1..2147483647)
.1.3.6.1.4.1.5003.10.12.2.22.1.3
acPMAtmCellRxMaxMaximum value within the period time.ro
INTEGER (-1..2147483647)
.1.3.6.1.4.1.5003.10.12.2.22.1.4
acPMAtmCellRxMinMinimum value within the period time.ro
INTEGER (-1..2147483647)
.1.3.6.1.4.1.5003.10.12.2.22.1.5
acPMAtmCellRxVolumeActivity volume.ro
Counter32
.1.3.6.1.4.1.5003.10.12.2.22.1.6
acPMAtmCellRxTimeBelowLowThresholdPercent of interval time for which gauge is below what was determined as the low threshold.ro
INTEGER (-1..100)
.1.3.6.1.4.1.5003.10.12.2.22.1.7
acPMAtmCellRxTimeBetweenThresholdsPercent of interval time for which gauge is above what was determined as the high threshold.ro
INTEGER (-1..100)
.1.3.6.1.4.1.5003.10.12.2.22.1.8
acPMAtmCellRxTimeAboveHighThresholdPercent of interval time for which gauge is between what were determined as the low and high thresholds.ro
INTEGER (-1..100)
.1.3.6.1.4.1.5003.10.12.2.22.1.9
acPMAtmCellRxFullDayAverageThe average of full 24 hours.ro
INTEGER (-1..2147483647)
.1.3.6.1.4.1.5003.10.12.2.22.1.10
acPMAtmCellDiscardedTableCounts the number of cells discarded in the reporting interval.
SEQUENCE OF AcPMAtmCellDiscardedEntry
.1.3.6.1.4.1.5003.10.12.2.23
acPMAtmCellDiscardedEntry
AcPMAtmCellDiscardedEntry
.1.3.6.1.4.1.5003.10.12.2.23.1
acPMAtmCellDiscardedInterfaceAtm interface 0,1 and 2.
INTEGER
.1.3.6.1.4.1.5003.10.12.2.23.1.1
acPMAtmCellDiscardedIntervalInterval index. 0 - current period (incomplete monitoring - mid period). 1 - Last full period. 2 - One before last.
INTEGER
.1.3.6.1.4.1.5003.10.12.2.23.1.2
acPMAtmCellDiscardedValValue of gauge or counter.ro
Gauge32
.1.3.6.1.4.1.5003.10.12.2.23.1.3
AC-PM-ATM-MIB - SNMP MIB Reference | MIBs Explorer