AC-ModularGW-MIB
AI MIB Summary
The AC-ModularGW-MIB facilitates monitoring of AudioCodes modular gateways by mapping analog and digital port assignments to their respective hardware modules. This module is deprecated and obsolete in versions 5.2 and 5.4 respectively, having been superseded by newer management interfaces.
This MIB is solely for AudioCodes modular Gateways. Use this MIBs status section for cross reference tables connecting analog/digital ports to the modules on which they are. The MIB has become deprecated as of version 5.2. It will be obsolete as of version 5.4
Main OID:
acModularGateway.1.3.6.1.4.1.5003.9.10.11
27
Objects
Active
Status
3
Dependencies
Imported Objects
Objects
27 total| Object Name |
|---|
audioCodes OBJECT IDENTIFIER .1.3.6.1.4.1.5003 |
acRegistrations OBJECT IDENTIFIER .1.3.6.1.4.1.5003.7 |
acGeneric OBJECT IDENTIFIER .1.3.6.1.4.1.5003.8 |
acProducts OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9 |
acBoardMibs OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10 |
acModularGatewayThis MIB is solely for AudioCodes modular Gateways. Use this MIBs status section for cross reference tables connecting analog/digital ports to the modules on which they are. The MIB has become deprecated as of version 5.2. It will be obsolete as of version 5.4 MODULE-IDENTITY .1.3.6.1.4.1.5003.9.10.11 |
acModularGatewayConfiguration OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.11.1 |
acModularGatewayStatus OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.11.2 |
acModularGWModules OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.11.2.1 |
acModularGWModuleTableThis table holds the information about each module in Audiocodes' modular gateways. If an index (Module number) is shown - then the module is in and working. You can also see the modules type, number of ports and it's first port's logical number allowing you to calculate which port is which logical trunk or analog channel. (This information is also obtainable in the acModularGWTrunkTable and acModularGWChannelTable). SEQUENCE OF AcModularGWModuleEntry .1.3.6.1.4.1.5003.9.10.11.2.1.20 |
acModularGWModuleEntry AcModularGWModuleEntry .1.3.6.1.4.1.5003.9.10.11.2.1.20.1 |
acModularGWModuleIndexModule index. 1 is the first Module - top left corner. 2 is the next Module to the right and so on. 4 is under 1.deprecated INTEGER .1.3.6.1.4.1.5003.9.10.11.2.1.20.1.1 |
acModularGWModuleTypeModule Type. The Modules are characterized according to their ports. 0 = Digital - Quad. 1 = Analog - FXS. 2 = Analog - FXO. 4 = Digital - FALC.rodeprecated Enumeration .1.3.6.1.4.1.5003.9.10.11.2.1.20.1.2 |
acModularGWModuleNumOfPortsThe number of physical interfaces in a module, analog or digital.rodeprecated INTEGER .1.3.6.1.4.1.5003.9.10.11.2.1.20.1.3 |
acModularGWModuleFirstPortNumThe logical number as seen in the general trunk/analog-channel table of the first port in the module in question. Since analog and digital ports can be operational at once, analog and digital ports may have same logical number.rodeprecated INTEGER .1.3.6.1.4.1.5003.9.10.11.2.1.20.1.4 |
acModularGWCrossReference OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.11.2.2 |
acModularGWTrunkTableThis table shows the trunk location and type. SEQUENCE OF AcModularGWTrunkEntry .1.3.6.1.4.1.5003.9.10.11.2.2.20 |
acModularGWTrunkEntry AcModularGWTrunkEntry .1.3.6.1.4.1.5003.9.10.11.2.2.20.1 |
acModularGWTrunkIndexTrunk index. The trunk in question's logical number.deprecated INTEGER .1.3.6.1.4.1.5003.9.10.11.2.2.20.1.1 |
acModularGWTrunkOnModuleNumModule number on which the trunk in question is placed. 1 is the first Module - top left corner. 2 is the next Module to the right and so on. 4 is under 1.rodeprecated INTEGER .1.3.6.1.4.1.5003.9.10.11.2.2.20.1.2 |
acModularGWTrunkOnPortNumPhysical Port on module. 1 - left most port.rodeprecated INTEGER .1.3.6.1.4.1.5003.9.10.11.2.2.20.1.3 |
acModularGWAnalogPortTableThis table shows the analog port location and type. SEQUENCE OF AcModularGWAnalogPortEntry .1.3.6.1.4.1.5003.9.10.11.2.2.21 |
acModularGWAnalogPortEntry AcModularGWAnalogPortEntry .1.3.6.1.4.1.5003.9.10.11.2.2.21.1 |
acModularGWAnalogPortIndexChannel index. The channel in question's logical number.deprecated INTEGER .1.3.6.1.4.1.5003.9.10.11.2.2.21.1.1 |
acModularGWAnalogPortOnModuleNumModule number on which the analog port in question is placed. 1 is the first Module - top left corner. 2 is the next Module to the right and so on. 4 is under 1.rodeprecated INTEGER .1.3.6.1.4.1.5003.9.10.11.2.2.21.1.2 |
acModularGWAnalogPortOnPortNumPhysical port on module. 1 - left most port.rodeprecated INTEGER .1.3.6.1.4.1.5003.9.10.11.2.2.21.1.3 |
acModularGatewayAction OBJECT IDENTIFIER .1.3.6.1.4.1.5003.9.10.11.3 |