Home/Catalog/AC-ANALOG-MIB

AC-ANALOG-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for AC-ANALOG-MIB.

Main OID:
acAnalog.1.3.6.1.4.1.5003.9.10.8
95
Objects
Active
Status
5
Dependencies

Imported Objects

Objects

95 total
Object Name
acAnalog
MODULE-IDENTITY
.1.3.6.1.4.1.5003.9.10.8
acAnalogConfiguration
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.1
acAnalogConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.1.1
acAnalogMisc
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.1.1.1
acAnalogMiscCurrentDisconnectDurationDefines the current-disconnect duration (in msec). This value is used in generation and detection. Access: Offline. AC INI-Param: CurrentDisconnectDurationrw
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.1.1.1.1
acAnalogMiscFlashHookPeriodDefines the flashhook period (in msec) for both analog and IP sides. For the analog side it defines: - The maximal hook-flash detection period (for FXS gateways). A longer signal is considered offhook / onhook event. - The hook-flash generation period (for FXO gateways). For the IP side it defines the flash-hook period that is reported to IP. The valid range is 25 to 1500. The default value is 700 msec. Note: For FXO gateways, a constant of 90 msec must be added to the required hook-flash period. For example, to generate a 450 msec hook-flash, set FlashHookPeriod to 540. . Access: Instant. AC INI-Param: FLASHHOOKPERIODrw
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.1.1.1.2
acAnalogMiscGroundKeyDetectionEnables/disables the analog ground key detection. 0 = Disable 1= Enable. Access: Offline. AC INI-Param: GroundKeyDetectionrw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.1.1.3
acAuxiliaryFiles
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.1.1.2
acAuxiliaryFilesFxsCoefficientsDefines the FXS coefficient file name. AC INI-Param: FXSCOEFFILENAMEro
SnmpAdminString
.1.3.6.1.4.1.5003.9.10.8.1.1.2.1
acAuxiliaryFilesFxoCoefficientsDefines the FXO coefficient filename. Max. 47 characters. AC INI-Param: FXOCOEFFILENAMEro
SnmpAdminString
.1.3.6.1.4.1.5003.9.10.8.1.1.2.2
acAnalogFxoConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.1.2
acAnalogFxo
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.1.2.1
acAnalogFxoFarEndDisconnectTypeThis parameter sets the source for the acEV_FAR_END_DISCONNECTED event (or for the relevant control protocol event). It is a bit field parameter, hence (for example) if both CPT and current disconnect are required, the parameter should be set to 5. FarDisconnect contributor: 1 = CPT 2 = PolarityReversal 4 = CurrentDisconnect 8 = Silence. Access: Offline. AC INI-Param: FARENDDISCONNECTTYPErw
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.1.2.1.1
acAnalogFxoCountryCoefficientsAllows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: CountryCoefficientsrw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.2.1.2
acAnalogFxoDCRemoverDetermines whether to enable the analog DC remover in the DAA. One of the following values: 0 = DC remover is disabled 1 = DC remover is enabled. Access: Offline. AC INI-Param: EnableAnalogDCRemoverrw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.2.1.3
acAnalogFxoFarEndDisconnectToneTable
SEQUENCE OF AcAnalogFxoFarEndDisconnectToneEntry
.1.3.6.1.4.1.5003.9.10.8.1.2.1.21
acAnalogFxoFarEndDisconnectToneEntry
AcAnalogFxoFarEndDisconnectToneEntry
.1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1
acAnalogFxoFarEndDisconnectToneRowStatusFar End Disconnect table row-status. AC INI-Param: N/Arw
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.1
acAnalogFxoFarEndDisconnectToneActionFar End Disconnect table action. AC INI-Param: N/Arw
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.2
acAnalogFxoFarEndDisconnectToneActionResultFar End Disconnect table result. AC INI-Param: N/Aro
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.3
acAnalogFxoFarEndDisconnectToneIndexIndex for table use. AC INI-Param: N/Aro
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.4
acAnalogFxoFarEndDisconnectToneTypeDefines which CPT types are detected as far-end disconnect. The CPT type is based on the acTCallProgressToneType enum. This is valid when FarEndDisconnectType allows CPT detection. Range = An array of up to 4 tone types. Access: Offline. AC INI-Param: DISCONNECTTONETYPErw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.2.1.21.1.5
acAnalogFxsConfig
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.1.3
acAnalogFxs
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.1.3.1
acAnalogFxsPolarityReversalTypeSets the type of the polarity reversal signal used for the network far-end answer and disconnect indications. Smooth reversal prevents negative effects as non-required ringing. 0 = Soft reverse polarity 1 = Hard reverse polarity. Access: Offline. AC INI-Param: POLARITYREVERSALTYPErw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.3.1.1
acAnalogFxsMeteringTypeSets the metering method for charging pulses. 0 = 12 kHz sinusoidal bursts 1 = 16 kHz sinusoidal bursts 2 = Polarity Reversal pulses. Access: Offline. AC INI-Param: METERINGTYPErw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.3.1.2
acAnalogFxsLifeLineTypeDefines the Lifeline phone type. The Lifeline phone is available (for FXS only) on port 4 in MP-104 and MP-108, on port 2 in MP-102, on ports 1-4 in the MP-118, and on port 2 of each analog module in the Mediant 1000. 0 = activate Lifeline phone on power down 1 = activate Lifeline phone on power down or on detection of LAN disconnect 2 = activate Lifeline phone on power down, or on detection of LAN disconnect, or on loss of ping. Access: Offline. AC INI-Param: LIFELINETYPErw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.3.1.3
acAnalogFxsMinFlashHookTimeSets the minimal time (in msec) for detection of a flash-hook event (for FXS only). The valid range is 25 to 300. The default value is 300 msec. Detection is guaranteed for flash hook periods of at least 60 msec (when setting the minimal time to 25). Flash-hook signals that last a shorter period of time are ignored. Note: It is recommended to reduce the detection time by 50 msec from the desired value (e.g. if you set the value as 200 msec, then enter 150 msec, i.e. 200 minus 50). . Access: Offline. AC INI-Param: MINFLASHHOOKTIMErw
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.1.3.1.4
acAnalogFxsCallerIDTimingModeDefines the Analog CallerID Timing Mode. 0 = CallerID transferred between first and second rings 1 = CallerID transferred on valid Off ring. Access: Offline. AC INI-Param: ANALOGCALLERIDTIMINGMODErw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.3.1.5
acAnalogFxsBellcoreCallerIDTypeOneSubStandardSelects the sub-standard of the Bellcore Caller ID type. 0 = Between_Rings 1 = Not_Ring_Related 2 = Before_Ring_RP_AS. Access: Offline. AC INI-Param: BellcoreCallerIDTypeOneSubStandardrw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.3.1.6
acAnalogFxsETSICallerIDTypeOneSubStandardSelects the number denoting the ETSI CallerID Type 1 sub-standard. Either: 0 = ETSI_Between_Rings 1 = ETSI_Before_Ring_DT_AS 2 = ETSI_Before_Ring_RP_AS 3 = ETSI_Before_Ring_LR_DT_AS 4 = ETSI_Not_Ring_Related_DT_AS 5 = ETSI_Not_Ring_Related_RP_AS 6 = ETSI_Not_Ring_Related_LR_DT_AS. Access: Offline. AC INI-Param: ETSICallerIDTypeOneSubStandardrw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.3.1.7
acAnalogFxsETSIVMWITypeOneStandardSelects the number denoting the ETSI VMWI Type 1 Standard. Choose: 0 = ETSI_VMWI_Between_Rings 1 = ETSI_VMWI_Before_Ring_DT_AS 2 = ETSI_VMWI_Before_Ring_RP_AS 3 = ETSI_VMWI_Before_Ring_LR_DT_AS 4 = ETSI_VMWI_Not_Ring_Related_DT_AS 5 = ETSI_VMWI_Not_Ring_Related_RP_AS 6 = ETSI_VMWI_Not_Ring_Related_LR_DT_AS. Access: Offline. AC INI-Param: ETSIVMWITypeOneStandardrw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.3.1.8
acAnalogFxsBellcoreVMWITypeOneStandardUse this parameter to select the Bellcore VMWI standard. 0 - Between_Rings 1 - Not_Ring_Related. Access: Offline. AC INI-Param: BellcoreVMWITypeOneStandardrw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.3.1.9
acAnalogFxsDisableAutoCalibrationDetermines whether to enable the analog Autocalibration in the DAA. One of the following values: 0 = Auto calibration is enabled 1 = Auto calibration is disabled. Access: Offline. AC INI-Param: DisableAnalogAutoCalibrationrw
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.1.3.1.10
acAnalogFxsExternalLifeLinePortsSet the amount of FXS ports which will be connected to an external life line and will be disabled (max value is half of the FXS ports). Access: Offline. AC INI-Param: ExternalLifeLinePortsrw
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.1.3.1.11
acAnalogFxsCountryCoefficientsAllows the user to modify the line characteristic (AC and DC) according to country. Access: Offline. AC INI-Param: FXSCountryCoefficientsrw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.3.1.12
acAnalogFxsTTXVoltageLevelSets the TTX pulses voltage level. 0 = 0Vrms sinusoidal bursts 1 = 0.5Vrms sinusoidal bursts 2 = 1Vrms sinusoidal bursts -1 = notAvailable. Access: Offline. AC INI-Param: AnalogTTXVoltageLevelrw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.1.3.1.13
acAnalogStatus
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.2
acAnalogStatusMisc
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.2.1
acAnalogStatusMiscFxsOrFxoBoard is Fxs Or Fxo (For all devices except MP118). For MP118 - see acAnalogFxsFxoType for a line specific status. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.2.1.1
acAnalogStatusMiscBoardTemperatureTemperature of the board in degrees Celsius, should not go higher then 60!. AC INI-Param: N/Aro
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.2.1.2
acAnalogStatusMiscAnalogChannelsCountNumber of the Analog channels in the board. AC INI-Param: N/Aro
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.2.1.3
acAnalogFxsFxo
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.2.20
acAnalogFxsFxoTable
SEQUENCE OF AcAnalogFxsFxoEntry
.1.3.6.1.4.1.5003.9.10.8.2.20.1
acAnalogFxsFxoEntry
AcAnalogFxsFxoEntry
.1.3.6.1.4.1.5003.9.10.8.2.20.1.1
acAnalogFxsFxoIndexIndex for table use. AC INI-Param: N/A
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.2.20.1.1.1
acAnalogFxsFxoTypeLine is Fxs Or Fxo. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.2.20.1.1.2
acAnalogFxsFxoChipRevNumFxs/Fxo's Chip revision number. AC INI-Param: N/Aro
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.2.20.1.1.3
acAnalogFxsFxoHookStateThe hook state of the analog line. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.2.20.1.1.4
acAnalogLegs
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.2.21
acAnalogLegsTable
SEQUENCE OF AcAnalogLegsEntry
.1.3.6.1.4.1.5003.9.10.8.2.21.1
acAnalogLegsEntry
AcAnalogLegsEntry
.1.3.6.1.4.1.5003.9.10.8.2.21.1.1
acAnalogLegsLegIndexDecribes The Digital EndPoint In A Call. AC INI-Param: N/A
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.2.21.1.1.1
acAnalogLegsCallIndexDecribes The Call which The Rtp EndPoint Participant In It. AC INI-Param: N/Aro
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.2.21.1.1.2
acAnalogLegsAnalogTypeDescribs whether the board is FXS or FXO. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.2.21.1.1.3
acAnalogLegsEchoCancellerEnables or Disables the Echo Canceller. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.2.21.1.1.4
acAnalogLegsHighPassFilterEnables or Disables theHigh Pass Filter. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.2.21.1.1.5
acAnalogLegsDTMFDetectionEnables or Disables the DTMF Detection. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.2.21.1.1.6
acAnalogLegsVoiceVolumeDescribs the volume of the voice in dB. AC INI-Param: N/Aro
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.2.21.1.1.7
acAnalogLegsInputGainDescribes the Input Gain on the leg in dB. AC INI-Param: N/Aro
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.2.21.1.1.8
acAnalogLegsLegNameDescribes the Leg Name as in the Control Protocol. AC INI-Param: N/Aro
SnmpAdminString
.1.3.6.1.4.1.5003.9.10.8.2.21.1.1.9
acAnalogAction
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.3
acAnalogFxoAction
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.3.1
acAnalogFxoLineTestTable
SEQUENCE OF AcAnalogFxoLineTestEntry
.1.3.6.1.4.1.5003.9.10.8.3.1.1
acAnalogFxoLineTestEntry
AcAnalogFxoLineTestEntry
.1.3.6.1.4.1.5003.9.10.8.3.1.1.1
acAnalogFxoLineTestIndexIndex for table use. AC INI-Param: N/A
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.3.1.1.1.1
acAnalogFxoLineTestActivateActivate line testing in an FXO analog line according to a given line-index. AC INI-Param: N/Arw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.3.1.1.1.2
acAnalogFxoLineTestHookStateThe hook state of the analog line. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.3.1.1.1.3
acAnalogFxoLineTestPolarityStatusThe line's polarity state. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.3.1.1.1.4
acAnalogFxoLineTestLineConnectionStatusThe connection's status of the line. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.3.1.1.1.5
acAnalogFxoLineTestLineCurrentThe line's current [ma]. AC INI-Param: N/Aro
Integer32 (-1..24)
.1.3.6.1.4.1.5003.9.10.8.3.1.1.1.6
acAnalogFxoLineTestLineVoltageThe line's voltage [V]. AC INI-Param: N/Aro
Integer32 (-128..128)
.1.3.6.1.4.1.5003.9.10.8.3.1.1.1.7
acAnalogFxoLineTestRingStateThe Ring's State. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.3.1.1.1.8
acAnalogFxoLineTestLinePolarityThe line's polarity state. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.3.1.1.1.9
acAnalogFxoLineTestMwiStateMwi's state. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.3.1.1.1.10
acAnalogFxoLineTestLastCurrentDisconnectDurationLast current disconnect duration in msec. AC INI-Param: N/Aro
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.3.1.1.1.11
acAnalogFxsAction
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.3.2
acAnalogFxsLineTestTable
SEQUENCE OF AcAnalogFxsLineTestEntry
.1.3.6.1.4.1.5003.9.10.8.3.2.1
acAnalogFxsLineTestEntry
AcAnalogFxsLineTestEntry
.1.3.6.1.4.1.5003.9.10.8.3.2.1.1
acAnalogFxsLineTestIndexIndex for table use. AC INI-Param: N/A
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.3.2.1.1.1
acAnalogFxsLineTestActivateActivate line testing in a FXS analog line according to a given line-index. AC INI-Param: N/Arw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.3.2.1.1.2
acAnalogFxsLineTestHookStateThe hook state of the analog line. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.3.2.1.1.3
acAnalogFxsLineTestRingStateLine's ring state. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.3.2.1.1.4
acAnalogFxsLineTestPolarityStatusLine's reversal-polarity. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.3.2.1.1.5
acAnalogFxsLineTestMessageWaitingIndicationLine's messgae waiting indication state. AC INI-Param: N/Aro
Enumeration
.1.3.6.1.4.1.5003.9.10.8.3.2.1.1.6
acAnalogFxsLineTestLineCurrentReadingThe Line current reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/Aro
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.3.2.1.1.7
acAnalogFxsLineTestLineVoltageReadingThe Line voltage reading in 10mV units. In case of MP124 the Line voltage reading in 1V units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/Aro
Integer32 (-6000..6000)
.1.3.6.1.4.1.5003.9.10.8.3.2.1.1.8
acAnalogFxsLineTestAnalogVoltageReadingThe current analog voltage reading in 10mV units. his test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/Aro
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.3.2.1.1.9
acAnalogFxsLineTestRingVoltageReadingThe current ring voltage reading in 10mV units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/Aro
Integer32 (-13000..13000)
.1.3.6.1.4.1.5003.9.10.8.3.2.1.1.10
acAnalogFxsLineTestLongLineCurrentReadingThe current long line reading in 10ua units. This test is supported only in line no. 0. Not supported on MP500. In case of MP124 this test is supported in all ports except ports 2 and 3. AC INI-Param: N/Aro
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.3.2.1.1.11
acAnalogCommonAction
OBJECT IDENTIFIER
.1.3.6.1.4.1.5003.9.10.8.3.3
acAnalogCommonChannelTableTable for common channels operations.
SEQUENCE OF AcAnalogCommonChannelEntry
.1.3.6.1.4.1.5003.9.10.8.3.3.1
acAnalogCommonChannelEntry
AcAnalogCommonChannelEntry
.1.3.6.1.4.1.5003.9.10.8.3.3.1.1
acAnalogCommonChannelIndexIndex for table use, the current channel. AC INI-Param: N/A
Unsigned32
.1.3.6.1.4.1.5003.9.10.8.3.3.1.1.1
acAnalogCommonChannelActionAn action to make on the current channel, The Reset action is for Analog channels only. AC INI-Param: N/Arw
Enumeration
.1.3.6.1.4.1.5003.9.10.8.3.3.1.1.2
AC-ANALOG-MIB - SNMP MIB Reference | MIBs Explorer