Home/Catalog/A3COM-HUWAEI-LswPERFORMANCE-MIB

A3COM-HUWAEI-LswPERFORMANCE-MIB

AI MIB Summary

Standard SNMP MIB module defining data structures for A3COM-HUWAEI-LswPERFORMANCE-MIB.

Main OID:
performance.1.3.6.1.4.1.2011.1.3.4.4
29
Objects
Active
Status
6
Dependencies

Imported Objects

Objects

29 total
Object Name
rmonExtendEventsV2
OBJECT IDENTIFIER
.1.3.6.1.4.1.2011.1.3.4.0
pririsingAlarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.1.3.4.0.1
prifallingAlarm
NOTIFICATION-TYPE
.1.3.6.1.4.1.2011.1.3.4.0.2
performance
MODULE-IDENTITY
.1.3.6.1.4.1.2011.1.3.4.4
RFC1213-MIB
Unknown
.1.3.6.1.4.1.2011.1.3.4.4
prialarmTable
SEQUENCE OF PriAlarmEntry
.1.3.6.1.4.1.2011.1.3.4.4.1
prialarmEntry
PriAlarmEntry
.1.3.6.1.4.1.2011.1.3.4.4.1.1
prialarmIndexro
INTEGER
.1.3.6.1.4.1.2011.1.3.4.4.1.1.1
prialarmIntervalrw
INTEGER
.1.3.6.1.4.1.2011.1.3.4.4.1.1.2
prialarmVariablerw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.1.3.4.4.1.1.3
prialarmSympolrw
DisplayString (SNMPv2-TC)
.1.3.6.1.4.1.2011.1.3.4.4.1.1.4
prialarmSampleTyperw
Enumeration
.1.3.6.1.4.1.2011.1.3.4.4.1.1.5
prialarmValuero
INTEGER
.1.3.6.1.4.1.2011.1.3.4.4.1.1.6
prialarmStartupAlarmrw
Enumeration
.1.3.6.1.4.1.2011.1.3.4.4.1.1.7
prialarmRisingThresholdrw
INTEGER
.1.3.6.1.4.1.2011.1.3.4.4.1.1.8
prialarmFallingThresholdrw
INTEGER
.1.3.6.1.4.1.2011.1.3.4.4.1.1.9
prialarmRisingEventIndexrw
INTEGER
.1.3.6.1.4.1.2011.1.3.4.4.1.1.10
prialarmFallingEventIndexrw
INTEGER
.1.3.6.1.4.1.2011.1.3.4.4.1.1.11
prialarmStatCyclerw
INTEGER
.1.3.6.1.4.1.2011.1.3.4.4.1.1.12
prialarmStatTyperw
Enumeration
.1.3.6.1.4.1.2011.1.3.4.4.1.1.13
prialarmOwnerrw
OwnerString (IF-MIB)
.1.3.6.1.4.1.2011.1.3.4.4.1.1.14
prialarmStatusrw
EntryStatus (RMON-MIB)
.1.3.6.1.4.1.2011.1.3.4.4.1.1.15
hwrmonEnableTable
SEQUENCE OF HwrmonEnableTableEntry
.1.3.6.1.4.1.2011.1.3.4.5
hwrmonEnableTableEntry
HwrmonEnableTableEntry
.1.3.6.1.4.1.2011.1.3.4.5.1
hwrmonEnableIfIndexro
INTEGER
.1.3.6.1.4.1.2011.1.3.4.5.1.1
hwrmonEnableStatusrw
Enumeration
.1.3.6.1.4.1.2011.1.3.4.5.1.2
hwTrapDestTable
SEQUENCE OF HWTrapDestEntry
.1.3.6.1.4.1.2011.1.3.4.6
hwTrapDestEntry
HWTrapDestEntry
.1.3.6.1.4.1.2011.1.3.4.6.1
hwTrapDestVersionrw
Enumeration
.1.3.6.1.4.1.2011.1.3.4.6.1.1

A3COM-HUWAEI-LswPERFORMANCE-MIB Technical Reference Overview

The A3COM-HUWAEI-LswPERFORMANCE-MIB SNMP MIB module published by Huawei defines 29 managed OID objects, including 20 scalar/column metrics, 3 SNMP tables, and 2 trap/notification events anchored at base OID .1.3.6.1.4.1.2011.1.3.4.4. Key tabular structures include prialarmTable, hwrmonEnableTable, hwTrapDestTable. Monitored SNMP traps/notifications include pririsingAlarm, prifallingAlarm.

Key OID Definitions in A3COM-HUWAEI-LswPERFORMANCE-MIB

prialarmTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.1.3.4.4.1

A list of alarm entries.

hwrmonEnableTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.1.3.4.5

A list of enable rmon entries.

hwTrapDestTableSEQUENCEnot-accessible
.1.3.6.1.4.1.2011.1.3.4.6

Defines the trap destination Extend Table for providing, via SNMP, the capability of configure a trap dest.

pririsingAlarmNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.1.3.4.0.1

The SNMP trap that is generated when an alarm entry crosses its rising threshold and generates an event that is configured for sending SNMP traps.

prifallingAlarmNOTIFICATION-TYPEnot-accessible
.1.3.6.1.4.1.2011.1.3.4.0.2

The SNMP trap that is generated when an alarm entry crosses its falling threshold and generates an event that is configured for sending SNMP traps.

hwTrapDestEntryHWTrapDestEntrynot-accessible
.1.3.6.1.4.1.2011.1.3.4.6.1

Defines an entry in the hwTrapDestTable.

hwTrapDestVersionINTEGERread-create
.1.3.6.1.4.1.2011.1.3.4.6.1.1

The version for trap destination. This object may not be modified if the associated trapDestStatus object is equal to active(1).

rmonExtendEventsV2OBJECTnot-accessible
.1.3.6.1.4.1.2011.1.3.4.0

Definition point for pri RMON notifications.

prialarmEntryPriAlarmEntrynot-accessible
.1.3.6.1.4.1.2011.1.3.4.4.1.1

A list of parameters that set up a periodic checking for alarm conditions. For example, an instance of the alarmValue object might be named alarmValue.8

prialarmIndexINTEGERread-only
.1.3.6.1.4.1.2011.1.3.4.4.1.1.1

An index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device.

prialarmIntervalINTEGERread-write
.1.3.6.1.4.1.2011.1.3.4.4.1.1.2

The interval in seconds over which the data is sampled and compared with the rising and falling thresholds. When setting this variable, care should be taken in the case of deltaValue sampling - the interval should be set short enough that the sampled variable is very unlikely to increase or decrease by more than 2^31 - 1 during a single sampling interval. This object may not be modified if the associated alarmStatus object is equal to valid(1).

prialarmVariableDisplayStringread-write
.1.3.6.1.4.1.2011.1.3.4.4.1.1.3

The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Integer32, Counter32, Counter64, Gauge, or TimeTicks) may be sampled. Because SNMP access control is articulated entirely in terms of the contents of MIB views, no access control mechanism exists that can restrict the value of this object to identify only those objects that exist in a particular MIB view. Because there is thus no acceptable means of restricting the read access that could be obtained through the alarm mechanism, the probe must only grant write access to this object in those views that have read access to all objects on the probe. During a set operation, if the supplied variable name is not available in the selected MIB view, a badValue error must be returned. If at any time the variable name of an established alarmEntry is no longer available in the selected MIB view, the probe must change the status of this alarmEntry to invalid(4). This object may not be modified if the associated alarmStatus object is equal to valid(1).

prialarmSampleTypeINTEGERread-write
.1.3.6.1.4.1.2011.1.3.4.4.1.1.5

The method of sampling the selected variable and calculating the value to be compared against the thresholds. If the value of this object is absoluteValue(1), the value of the selected variable will be compared directly with the thresholds at the end of the sampling interval. If the value of this object is deltaValue(2), the value of the selected variable at the last sample will be subtracted from the current value, and the difference compared with the thresholds. This object may not be modified if the associated alarmStatus object is equal to valid(1).

prialarmValueINTEGERread-only
.1.3.6.1.4.1.2011.1.3.4.4.1.1.6

The value of the statistic during the last sampling period. For example, if the sample type is deltaValue, this value will be the difference between the samples at the beginning and end of the period. If the sample type is absoluteValue, this value will be the sampled value at the end of the period. This is the value that is compared with the rising and falling thresholds. The value during the current sampling period is not made available until the period is completed and will remain available until the next period completes.

prialarmStartupAlarmINTEGERread-write
.1.3.6.1.4.1.2011.1.3.4.4.1.1.7

The alarm that may be sent when this entry is first set to valid. If the first sample after this entry becomes valid is greater than or equal to the risingThreshold and alarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3), then a single rising alarm will be generated. If the first sample after this entry becomes valid is less than or equal to the fallingThreshold and alarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3), then a single falling alarm will be generated. This object may not be modified if the associated alarmStatus object is equal to valid(1).

prialarmRisingThresholdINTEGERread-write
.1.3.6.1.4.1.2011.1.3.4.4.1.1.8

A threshold for the sampled statistic. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval was less than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is greater than or equal to this threshold and the associated alarmStartupAlarm is equal to risingAlarm(1) or risingOrFallingAlarm(3). After a rising event is generated, another such event will not be generated until the sampled value falls below this threshold and reaches the alarmFallingThreshold. This object may not be modified if the associated alarmStatus object is equal to valid(1).

prialarmFallingThresholdINTEGERread-write
.1.3.6.1.4.1.2011.1.3.4.4.1.1.9

A threshold for the sampled statistic. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval was greater than this threshold, a single event will be generated. A single event will also be generated if the first sample after this entry becomes valid is less than or equal to this threshold and the associated alarmStartupAlarm is equal to fallingAlarm(2) or risingOrFallingAlarm(3). After a falling event is generated, another such event will not be generated until the sampled value rises above this threshold and reaches the alarmRisingThreshold. This object may not be modified if the associated alarmStatus object is equal to valid(1).

prialarmRisingEventIndexINTEGERread-write
.1.3.6.1.4.1.2011.1.3.4.4.1.1.10

The index of the eventEntry that is used when a rising threshold is crossed. The eventEntry identified by a particular value of this index is the same as identified by the same value of the eventIndex object. If there is no corresponding entry in the eventTable, then no association exists. In particular, if this value is zero, no associated event will be generated, as zero is not a valid event index. This object may not be modified if the associated alarmStatus object is equal to valid(1).

prialarmFallingEventIndexINTEGERread-write
.1.3.6.1.4.1.2011.1.3.4.4.1.1.11

The index of the eventEntry that is used when a falling threshold is crossed. The eventEntry identified by a particular value of this index is the same as identified by the same value of the eventIndex object. If there is no corresponding entry in the eventTable, then no association exists. In particular, if this value is zero, no associated event will be generated, as zero is not a valid event index. This object may not be modified if the associated alarmStatus object is equal to valid(1).

prialarmOwnerOwnerStringread-write
.1.3.6.1.4.1.2011.1.3.4.4.1.1.14

The entity that configured this entry and is therefore using the resources assigned to it.

prialarmStatusEntryStatusread-write
.1.3.6.1.4.1.2011.1.3.4.4.1.1.15

The status of this alarm entry.

hwrmonEnableTableEntryHwrmonEnableTableEntrynot-accessible
.1.3.6.1.4.1.2011.1.3.4.5.1

A list of parameters that set up a hwrmonEnableTable

hwrmonEnableIfIndexINTEGERread-only
.1.3.6.1.4.1.2011.1.3.4.5.1.1

Specify an interface to enable rmon.

hwrmonEnableStatusINTEGERread-write
.1.3.6.1.4.1.2011.1.3.4.5.1.2

Specify an interface to enable rmon.

More MIBs from Huawei

Browse all HuaweiMIBs →
H3C-ENTITY-VENDORTYPE-OID-MIB

SNMP MIB module

1462 objects→
HUAWEI-WLAN-CONFIGURATION-MIB

The HUAWEI-WLAN-CONFIGURATION-MIB facilitates the configuration and monitoring of Huawei Wireless LAN access point parameters, specifically managing AP port link profiles and broadcast suppression settings. This module enables administrators to enforce traffic control policies and optimize wireless network performance by adjusting switch profile associations and limiting broadcast traffic on specific ports.

1280 objects→
HUAWEI-XQoS-MIB

The HUAWEI-XQoS-MIB enables configuration and real-time monitoring of Class Based QoS parameters on Huawei network devices, specifically tracking traffic classification rules, queue states, and policy enforcement metrics. This module facilitates granular control over bandwidth allocation and packet prioritization by exposing objects for policy definitions, interface queue depths, and dropped packet counters associated with QoS classes.

1134 objects→
HUAWEI-ENT-VOICE-PBX-MIB

The HUAWEI-ENT-VOICE-PBX-MIB enables SNMP-based monitoring and configuration of Huawei enterprise PBX systems, specifically tracking voice trunk states, active call session counts, and hardware resource utilization for telephony management.

1011 objects→
HUAWEI-WLAN-DEVICE-MIB

The HUAWEI-WLAN-DEVICE-MIB enables SNMP-based monitoring and configuration of Huawei Access Point hardware, providing granular visibility into device status, radio interface statistics, client association counts, and operational health metrics.

897 objects→
HUAWEI-BRAS-SBC-MIB

The HUAWEI-BRAS-SBC-MIB module provides configuration and status monitoring for Huawei Broadband Remote Access Server (BRAS) Session Border Controllers, specifically tracking session establishment parameters, resource utilization, and protocol state variables. It enables administrators to manage SBC-specific attributes such as call routing policies, media stream limits, and session timeout thresholds within the broadband aggregation network.

848 objects→