A3COM-HUAWEI-PPP-OVER-SONET-MIB
AI MIB Summary
The A3COM-HUAWEI-PPP-OVER-SONET-MIB monitors and configures Point-to-Point Protocol over SONET (POS) interface parameters and reports alarm conditions on A3Com and Huawei network devices. It provides an operational table to track interface states, control configuration settings, and detect fault events within the SONET transport layer.
This MIB manages POS(PPP Over Sonet)interfaces by providing an operational table which controls parameters of each POS interface and reports alarm conditions.
Main OID:
h3cPos.1.3.6.1.4.1.2011.10.2.19
51
Objects
Active
Status
4
Dependencies
Imported Objects
Objects
51 total| Object Name |
|---|
h3cPosThis MIB manages POS(PPP Over Sonet)interfaces by providing
an operational table which controls parameters of each POS
interface and reports alarm conditions. MODULE-IDENTITY .1.3.6.1.4.1.2011.10.2.19 |
h3cPosMIBObjects OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.2.19.1 |
h3cPosParamTableThe pos parameter table. SEQUENCE OF H3cPosParamTableEntry .1.3.6.1.4.1.2011.10.2.19.1.1 |
h3cPosParamTableEntry H3cPosParamTableEntry .1.3.6.1.4.1.2011.10.2.19.1.1.1 |
h3cPosCRCThe length of CRCrw Enumeration .1.3.6.1.4.1.2011.10.2.19.1.1.1.1 |
h3cPosMTUMaximum Transfer Unit (MTU) of POS interfacerw INTEGER .1.3.6.1.4.1.2011.10.2.19.1.1.1.2 |
h3cPosScrambleScrambling is used to avoid continuous 0 or 1 in signals. This
object is to decide whether to scramble or notrw TruthValue (SNMPv2-TC) .1.3.6.1.4.1.2011.10.2.19.1.1.1.3 |
h3cPosClockSourceThe value indicates the source of clock signal. System indicates
that clock signals are from device itself and line for clock signals
from remoterw Enumeration .1.3.6.1.4.1.2011.10.2.19.1.1.1.4 |
h3cPosSdhFlagJ0The section trace byte. This node is used when the frame type is sdh.rw DisplayString .1.3.6.1.4.1.2011.10.2.19.1.1.1.5 |
h3cPosSdhFlagJ1The path trace byte. This node is used when the frame type is sdh.rw DisplayString .1.3.6.1.4.1.2011.10.2.19.1.1.1.6 |
h3cPosSonetFlagJ0The section trace byte. This node is used when the frame type is sonet.rw INTEGER .1.3.6.1.4.1.2011.10.2.19.1.1.1.7 |
h3cPosSonetFlagJ1The path trace byte. This node is used when the frame type is sonet.rw DisplayString .1.3.6.1.4.1.2011.10.2.19.1.1.1.8 |
h3cPosFlagC2The parameter for the channel signal value of C2 byterw INTEGER .1.3.6.1.4.1.2011.10.2.19.1.1.1.9 |
h3cPosFrameTypeThe frame type that encapsulates the packet. Default frame type is
sdh(Synchronous Digital Hierarchy) It also can be configured using
sonet type(Synchronous Optical Network).rw Enumeration .1.3.6.1.4.1.2011.10.2.19.1.1.1.10 |
h3cPosBindVlanIdThe vlan that this pos port binds. The vlan can not include any other
port, otherwise error will be returned. If the vlan has a virtual
interface, the status of virtual interface will be up or down according
to the link status or this pos.rw INTEGER .1.3.6.1.4.1.2011.10.2.19.1.1.1.11 |
h3cPosEncapsulationThe type of encapsulationrw Enumeration .1.3.6.1.4.1.2011.10.2.19.1.1.1.12 |
h3cPoskeepaliveTimeoutThe keeplive of hdlc. It is the query interval of link status. Two
members of a link should have same keeplive. The default 0 prohibits
detecting status of link.rw INTEGER .1.3.6.1.4.1.2011.10.2.19.1.1.1.13 |
h3cPosBERthresholdSFThe bit-error rate threshold for Signal Fault. SF threshold should
be greater than SD threshold.rw INTEGER .1.3.6.1.4.1.2011.10.2.19.1.1.1.14 |
h3cPosBERthresholdSDThe bit-error rate threshold for Signal Degrade. SD threshold should
be less than SF threshold.rw INTEGER .1.3.6.1.4.1.2011.10.2.19.1.1.1.15 |
h3cPosB1ErrorCounter for SBIPE(Section Bit Interleave Parity Error)ro Counter64 .1.3.6.1.4.1.2011.10.2.19.1.1.1.16 |
h3cPosB2ErrorCounter for LBIPE(Line Bit Interleave Parity Error)ro Counter64 .1.3.6.1.4.1.2011.10.2.19.1.1.1.17 |
h3cPosB3ErrorCounter for PBIPE(Path Bit Interleave Parity Error)ro Counter64 .1.3.6.1.4.1.2011.10.2.19.1.1.1.18 |
h3cPosM1ErrorHow many times does LREI(Line Remote Error Indication) occurro Counter64 .1.3.6.1.4.1.2011.10.2.19.1.1.1.19 |
h3cPosG1ErrorHow many times does PREI(Path Remote Error Indication) occurro Counter64 .1.3.6.1.4.1.2011.10.2.19.1.1.1.20 |
h3cPosFlagJ0TypeThe frame type that encapsulates the flag J0. Default frame type is
sdh(Synchronous Digital Hierarchy). It also can be configured using
sonet(Synchronous Optical Network) type.rw Enumeration .1.3.6.1.4.1.2011.10.2.19.1.1.1.21 |
h3cPosFlagJ1TypeThe frame type that encapsulates the flag J1. Default frame type is
sdh(Synchronous Digital Hierarchy). It also can be configured using
sonet(Synchronous Optical Network) type.rw Enumeration .1.3.6.1.4.1.2011.10.2.19.1.1.1.22 |
h3cPosB1TCAThresholdThreshold for B1 TCA.rw INTEGER .1.3.6.1.4.1.2011.10.2.19.1.1.1.23 |
h3cPosB2TCAThresholdThreshold for B2 TCA.rw INTEGER .1.3.6.1.4.1.2011.10.2.19.1.1.1.24 |
h3cPosB3TCAThresholdThreshold for B3 TCA.rw INTEGER .1.3.6.1.4.1.2011.10.2.19.1.1.1.25 |
h3cPosB1TCAEnableEnable traps of B1 TCA.rw Enumeration .1.3.6.1.4.1.2011.10.2.19.1.1.1.26 |
h3cPosB2TCAEnableEnable traps of B2 TCA.rw Enumeration .1.3.6.1.4.1.2011.10.2.19.1.1.1.27 |
h3cPosB3TCAEnableEnable traps of B3 TCA.rw Enumeration .1.3.6.1.4.1.2011.10.2.19.1.1.1.28 |
h3cPosMIBNotificationsPrefix OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.2.19.2 |
h3cPosMIBNotifications OBJECT IDENTIFIER .1.3.6.1.4.1.2011.10.2.19.2.0 |
h3cPosLOSAlarmAlarm indicates loss of signal NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.1 |
h3cPosLOFAlarmAlarm indicates loss of frame NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.2 |
h3cPosOOFAlarmAlarm indicates out of frame NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.3 |
h3cPosLAISAlarmAlarm when LAIS(Line Alarm Indication Signal) arrives NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.4 |
h3cPosLRDIAlarmAlarm when LRDI(Line Remote Defect Indication) arrives NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.5 |
h3cPosPRDIAlarmAlarm when PRDI(Path Remote Defect Indication) arrives NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.6 |
h3cPosPAISAlarmAlarm when PAIS(Path Alarm Indication Signal) arrives NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.7 |
h3cPosLOPAlarmAlarm indicates loss of pointer NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.8 |
h3cPosSTIMAlarmAlarm indicates inconsistency between sent and received J0 bytes. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.9 |
h3cPosPTIMAlarmAlarm indicates inconsistency between sent and received J1 bytes. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.10 |
h3cPosPSLMAlarmAlarm indicates a mismatched C2 byte. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.11 |
h3cPosLSDAlarmAlarm indicates that the B2 bit-error rate exceeds SD threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.12 |
h3cPosLSFAlarmAlarm indicates that the B2 bit-error rate exceeds SF threshold. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.13 |
h3cPosNormalAlarmAlarm indicates that the Pos interface state returns normal. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.14 |
h3cPosB1TCAlarmThreshold crossing alarms for B1. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.15 |
h3cPosB2TCAlarmThreshold crossing alarms for B2. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.16 |
h3cPosB3TCAlarmThreshold crossing alarms for B3. NOTIFICATION-TYPE .1.3.6.1.4.1.2011.10.2.19.2.0.17 |