companyMIB
AI MIB Summary
The `companyMIB` module facilitates the monitoring and management of Uninterruptible Power Supply (UPS) hardware via SNMP, exposing critical telemetry such as battery status, input/output voltage, load percentage, and remaining runtime.
The MIB module to describe UPS
Main OID:
companyMIB.1.3.6.1.4.1.21111
328
Objects
Active
Status
5
Dependencies
Imported Objects
Objects
328 total| Object Name |
|---|
companyMIBThe MIB module to describe UPS MODULE-IDENTITY .1.3.6.1.4.1.21111 |
products OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1 |
ups OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1 |
upsIdent OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1.1 |
upsIdManufacturerThe name of the UPS manufacturer.ro DisplayString .1.3.6.1.4.1.21111.1.1.1.1 |
upsIdProtocolThe UPS Protocol id.ro Enumeration .1.3.6.1.4.1.21111.1.1.1.2 |
upsIdModelNameThe UPS Model designation.ro DisplayString .1.3.6.1.4.1.21111.1.1.1.3 |
upsIdSerialNumberThe UPS serial no.ro DisplayString .1.3.6.1.4.1.21111.1.1.1.4 |
upsIdNameA string identifying the UPS. This object should be
set by the administrator.rw DisplayString .1.3.6.1.4.1.21111.1.1.1.5 |
upsIdFWVersionMain CPU firmware version.ro DisplayString .1.3.6.1.4.1.21111.1.1.1.6 |
upsIdUPSTypeUPS type.ro Enumeration .1.3.6.1.4.1.21111.1.1.1.7 |
upsRating OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1.2 |
upsRatinVoltageThe rating input voltage of UPSro NonNegativeInteger UNITS "0.1 Volt DC" .1.3.6.1.4.1.21111.1.1.2.1 |
upsRatoutVoltageThe rating output voltage of UPSro NonNegativeInteger UNITS "0.1 Volt DC" .1.3.6.1.4.1.21111.1.1.2.2 |
upsRatoutFrequencyThe rating output frequency of UPSro NonNegativeInteger UNITS "0.1 HZ" .1.3.6.1.4.1.21111.1.1.2.3 |
upsRatoutCurrentThe rating output current of UPSro NonNegativeInteger UNITS "0.1 Amp DC" .1.3.6.1.4.1.21111.1.1.2.4 |
upsRatoutApparentPowerThe rating output apparent power of UPSro NonNegativeInteger UNITS "0.1 VA" .1.3.6.1.4.1.21111.1.1.2.5 |
upsRatoutTruePowerThe rating output true power of UPSro NonNegativeInteger UNITS "0.1 Wt" .1.3.6.1.4.1.21111.1.1.2.6 |
upsRatBatVoltageThe rating battery voltage of UPSro NonNegativeInteger UNITS "0.1 vol" .1.3.6.1.4.1.21111.1.1.2.7 |
upsBattery OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1.3 |
upsBatStatusThe indication of the status in the UPS system's batteries.ro Enumeration .1.3.6.1.4.1.21111.1.1.3.1 |
upsBatSecondsOnBatteryIf the unit is on battery power, the elapsed time
since the UPS last switched to battery power, or the
time since the network management subsystem was last
restarted, whichever is less. -1 shall be returned
if the unit is not on battery power.ro INTEGER UNITS "seconds" .1.3.6.1.4.1.21111.1.1.3.2 |
upsBatEstMinutesRemainingAn estimate of the time to battery charge depletion
under the present load conditions if the utility power
is off and remains off, or if it were to be lost and
remain off.ro INTEGER UNITS "minutes" .1.3.6.1.4.1.21111.1.1.3.3 |
upsBatEstChargeRemainingAn estimate of the battery charge remaining expressed
as a percent of full charge.ro INTEGER .1.3.6.1.4.1.21111.1.1.3.4 |
upsBatPBatVoltageThe magnitude of the present Positive battery voltage.ro NonNegativeInteger UNITS "0.1 Volt DC" .1.3.6.1.4.1.21111.1.1.3.5 |
upsBatNBatVoltageThe magnitude of the present negative battery voltage.ro NonNegativeInteger UNITS "0.1 Volt DC" .1.3.6.1.4.1.21111.1.1.3.6 |
upsBatPBatCurrentThe positive battery present current.ro INTEGER UNITS "0.1 Amp DC" .1.3.6.1.4.1.21111.1.1.3.7 |
upsBatNBatCurrentThe present negative battery current.ro INTEGER UNITS "0.1 Amp DC" .1.3.6.1.4.1.21111.1.1.3.8 |
upsBatPBatChargCurrentThe Positive battery charging current.ro INTEGER UNITS "0.1 Amp DC" .1.3.6.1.4.1.21111.1.1.3.9 |
upsBatNBatchargCurrentThe present negative battery charging current.ro INTEGER UNITS "0.1 Amp DC" .1.3.6.1.4.1.21111.1.1.3.10 |
upsBatPBatDischargCurrentThe present positive battery discharging current.ro INTEGER UNITS "0.1 Amp DC" .1.3.6.1.4.1.21111.1.1.3.11 |
upsBatNBatDischargCurrentThe present negative battery discharging current.ro INTEGER UNITS "0.1 Amp DC" .1.3.6.1.4.1.21111.1.1.3.12 |
upsBatTemperatureThe ambient temperature at or near the UPS Battery
casing.ro INTEGER UNITS "degrees 0.1 Centigrade" .1.3.6.1.4.1.21111.1.1.3.13 |
upsBatNumberInSeriesThe number of battery in series.ro PositiveInteger (UPS-MIB) .1.3.6.1.4.1.21111.1.1.3.14 |
upsBatNumberInParallelThe number of battery in Parallel.ro PositiveInteger (UPS-MIB) .1.3.6.1.4.1.21111.1.1.3.15 |
upsBatPBatDischargCurrent2The present positive battery pipe2 discharging current.ro INTEGER UNITS "0.1 Amp DC" .1.3.6.1.4.1.21111.1.1.3.16 |
upsInput OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1.4 |
upsInLineBadsA count of the number of times the input entered an
out-of-tolerance condition as defined by the
manufacturer. This count is incremented by one each
time the input transitions from zero out-of-tolerance
lines to one or more input lines out-of-tolerance.ro NonNegativeInteger (UPS-MIB) .1.3.6.1.4.1.21111.1.1.4.1 |
upsInTtlApparentPowerTotal input apparent power .ro NonNegativeInteger UNITS "0.1VA" .1.3.6.1.4.1.21111.1.1.4.2 |
upsInTtlTruePowerTotal input active(true) power .ro NonNegativeInteger UNITS "0.1WT" .1.3.6.1.4.1.21111.1.1.4.3 |
upsInNumLinesThe number of input lines utilized in this device.
This variable indicates the number of rows in the
input table.ro NonNegativeInteger (UPS-MIB) .1.3.6.1.4.1.21111.1.1.4.4 |
upsInTableA list of input table entries. The number of entries
is given by the value of upsInputNumLines. SEQUENCE OF UpsInEntry .1.3.6.1.4.1.21111.1.1.4.5 |
upsInEntryAn entry containing information applicable to a
particular input line. UpsInEntry .1.3.6.1.4.1.21111.1.1.4.5.1 |
upsInLineIndexThe number of output linesro INTEGER .1.3.6.1.4.1.21111.1.1.4.5.1.1 |
upsInFrequencyThe present input frequency.ro NonNegativeInteger UNITS "0.1 Hertz" .1.3.6.1.4.1.21111.1.1.4.5.1.2 |
upsInVoltageThe input utility line voltage .ro INTEGER UNITS "0.1 Volts" .1.3.6.1.4.1.21111.1.1.4.5.1.3 |
upsInCurrentThe magnitude of the present input currentro INTEGER UNITS "0.1Amp" .1.3.6.1.4.1.21111.1.1.4.5.1.4 |
upsInApparentPowerThe magnitude of the present input Apparent power.ro NonNegativeInteger UNITS "0.1VA" .1.3.6.1.4.1.21111.1.1.4.5.1.5 |
upsInTruePowerThe magnitude of the present input true power.ro NonNegativeInteger UNITS "0.1Watts" .1.3.6.1.4.1.21111.1.1.4.5.1.6 |
upsInPowerFactorInput true power/apparent power factorro NonNegativeInteger UNITS "0.01" .1.3.6.1.4.1.21111.1.1.4.5.1.7 |
upsInLineVoltageThe input utility line voltage .
if upsInLineIndex =1, upsInLineVoltage = Line voltage of RS phase;
if upsInLineIndex =2, upsInLineVoltage = Line voltage of ST phase;
if upsInLineIndex =3, upsInLineVoltage = Line voltage of TR phase.ro INTEGER UNITS "0.1 Volts" .1.3.6.1.4.1.21111.1.1.4.5.1.8 |
upsInTtlVoltageThe input utility line tatol voltage .ro INTEGER UNITS "0.1 Volts" .1.3.6.1.4.1.21111.1.1.4.6 |
upsInTtlCurrentThe input utility line tatol current.ro INTEGER UNITS "0.1 A" .1.3.6.1.4.1.21111.1.1.4.7 |
upsOutput OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1.5 |
upsOutSourceThe present source of output power. The enumeration
none(2) indicates that there is no source of output
power (and therefore no output power), for example,
the system has opened the output breaker.==UPS standby modero Enumeration .1.3.6.1.4.1.21111.1.1.5.1 |
upsOutTtlApparentPowerTotal output apparent power .ro NonNegativeInteger UNITS "0.1VA" .1.3.6.1.4.1.21111.1.1.5.3 |
upsOutTtlTruePowerTotal output active(true) power .ro NonNegativeInteger UNITS "0.1Watts" .1.3.6.1.4.1.21111.1.1.5.4 |
upsOutTtlPercentLoadThe percentage of the UPS power capacity presently
being used on this output line, i.e., the greater of
the percent load of true power capacity and the
percent load of VA.ro INTEGER .1.3.6.1.4.1.21111.1.1.5.5 |
upsOutNumLinesThe number of output lines utilized in this device.
This variable indicates the number of rows in the
output table.ro INTEGER .1.3.6.1.4.1.21111.1.1.5.6 |
upsOutTableA list of output table entries. The number of
entries is given by the value of upsOutputNumLines. SEQUENCE OF UpsOutEntry .1.3.6.1.4.1.21111.1.1.5.7 |
upsOutEntryAn entry containing information applicable to a
particular output line. UpsOutEntry .1.3.6.1.4.1.21111.1.1.5.7.1 |
upsOutLineIndexThe output line identifier.ro INTEGER .1.3.6.1.4.1.21111.1.1.5.7.1.1 |
upsOutVoltageThe output voltage of the UPS system.ro INTEGER UNITS "0.1 Volts" .1.3.6.1.4.1.21111.1.1.5.7.1.2 |
upsOutCurrentThe output current of the UPS systemro INTEGER UNITS "0.1 Amp" .1.3.6.1.4.1.21111.1.1.5.7.1.3 |
upsOutApparentPowerThe present output apparent power.ro NonNegativeInteger UNITS "0.1VA" .1.3.6.1.4.1.21111.1.1.5.7.1.4 |
upsOutTruePowerThe present output true power.ro NonNegativeInteger UNITS "0.1Watts" .1.3.6.1.4.1.21111.1.1.5.7.1.5 |
upsOutPowerFactorOutput true power/apparent power factorro NonNegativeInteger UNITS "0.01" .1.3.6.1.4.1.21111.1.1.5.7.1.6 |
upsOutPercentLoadThe percentage of the UPS power capacity presently
being used on this output line, i.e., the greater of
the percent load of true power capacity and the
percent load of VA.ro INTEGER .1.3.6.1.4.1.21111.1.1.5.7.1.7 |
upsOutLineVoltageThe output line voltage of the UPS system.
if upsOutLineIndex =1, upsOutLineVoltage = Line voltage of RS phase;
if upsOutLineIndex =2, upsOutLineVoltage = Line voltage of ST phase;
if upsOutLineIndex =3, upsOutLineVoltage = Line voltage of TR phase.ro INTEGER UNITS "0.1 Volts" .1.3.6.1.4.1.21111.1.1.5.7.1.8 |
upsOutFrequencyThe present output frequency.ro NonNegativeInteger UNITS "0.1Hertz" .1.3.6.1.4.1.21111.1.1.5.7.1.9 |
upsOutTtlVoltageTotal output voltage .ro INTEGER UNITS "0.1vot" .1.3.6.1.4.1.21111.1.1.5.8 |
upsOutTtlCurrentTotal output current.ro INTEGER UNITS "0.1A" .1.3.6.1.4.1.21111.1.1.5.9 |
upsOutStatusFor HVDC device.
char status[4];
status[0]status[1]:00, no output1; 01, line output1; 02, bat output1
status[2]status[3]:00, no output2; 01, line output2; 02, bat output2ro DisplayString .1.3.6.1.4.1.21111.1.1.5.10 |
upsOutSource2For HVDC(protocol:P12) machine. The present source of output power. The enumeration
none(2) indicates that there is no source of output
power (and therefore no output power), for example,
the system has opened the output breaker.==UPS standby modero Enumeration .1.3.6.1.4.1.21111.1.1.5.11 |
upsBypass OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1.6 |
upsByFrequencyThe present bypass frequency.ro INTEGER UNITS "0.1 Hertz" .1.3.6.1.4.1.21111.1.1.6.1 |
upsByNumLinesThe number of bypass lines utilized in this device.
This entry indicates the number of rows in the bypass
table.ro INTEGER .1.3.6.1.4.1.21111.1.1.6.2 |
upsByTableA list of bypass table entries. The number of
entries is given by the value of upsBypassNumLines. SEQUENCE OF UpsByEntry .1.3.6.1.4.1.21111.1.1.6.3 |
upsByEntryAn entry containing information applicable to a
particular bypass input. UpsByEntry .1.3.6.1.4.1.21111.1.1.6.3.1 |
upsByLineIndexThe bypass line identifier.ro INTEGER .1.3.6.1.4.1.21111.1.1.6.3.1.1 |
upsByVoltageThe present bypass voltage.ro INTEGER UNITS "0.1 Volts" .1.3.6.1.4.1.21111.1.1.6.3.1.2 |
upsByCurrentThe present bypass current.ro INTEGER UNITS "0.1 RMS Amp" .1.3.6.1.4.1.21111.1.1.6.3.1.3 |
upsByPowerThe present true power conveyed by the bypass.ro NonNegativeInteger UNITS "0.1Watts" .1.3.6.1.4.1.21111.1.1.6.3.1.4 |
upsByLineVoltageThe present bypass line voltage.
if upsByLineIndex=1,upsByLineVoltage=Line voltage of RS phase;
if upsByLineIndex=2,upsByLineVoltage=Line voltage of ST phase;
if upsByLineIndex=3,upsByLineVoltage=Line voltage of TR phase.ro INTEGER UNITS "0.1 Volts" .1.3.6.1.4.1.21111.1.1.6.3.1.5 |
upsTest OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1.7 |
upsTstBatteryTestThis object specify the battery test type and initiate
battery test. If battTestWithTime selected, the test
time is refer to upsTestBatteryTestTime.rw Enumeration .1.3.6.1.4.1.21111.1.1.7.1 |
upsTstBatteryTestResultThe results of the current or last UPS diagnostics
test performed. The values for donePassed(1),
doneWarning(2), and doneError(3) indicate that the
test completed either successfully, with a warning, or
with an error, respectively. The value aborted(4) is
returned for tests which are aborted by setting the
value of upsTestId to upsTestAbortTestInProgress.
Tests which have not yet concluded are indicated by
inProgress(5). The value noTestsInitiated(6)
indicates that no previous test results are available,
such as is the case when no tests have been run since
the last reinitialization of the network management
subsystem and the system has no provision for non-
volatile storage of test results.ro Enumeration .1.3.6.1.4.1.21111.1.1.7.2 |
upsTstBatteryTestStartTimeThe value of the time the test in progress was initiated,
or, if no test is in progress, the time the previous test
was initiated. If the value of upsTestBatteryTestResult
is noTestsInitiated(6), upsTestStartTime has the value
01/01/1970 00:00:00. format is (MM/DD/YYYY hh:mm:ss)ro DisplayString .1.3.6.1.4.1.21111.1.1.7.3 |
upsTstBatterySettingTimeThe object specify the test time for battery test, the unit is secondsrw INTEGER .1.3.6.1.4.1.21111.1.1.7.4 |
upsControl OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1.8 |
upsCtlShutdownDelayThe delay in seconds the UPS remains on after being told
to turn off. if value=-2 cancel shutdown, if value=-1 donothing,
value=0 shutdown ups immediatelyrw INTEGER (-2..2147483648) UNITS "seconds" .1.3.6.1.4.1.21111.1.1.8.1 |
upsCtlSleepTimeThe time in minutes for the UPS to go to sleep when
instructed. When in sleep mode, the UPS will not provide
output power regardless of the input line state. Once the
specified time has elapsed, output power will be restored.
This is a configuration setting. The UPS will not go to
sleep until told to do so by the manager from a management
station.
Any input value is allowed, however the UPS only recognizes
0 - 9999 minutes in one minute increments.
If the provided value is higher than the highest acceptable
value, the highest acceptable value is used.rw INTEGER (-1..2147483648) UNITS "minutes" .1.3.6.1.4.1.21111.1.1.8.2 |
upsCtlStartupAfterDelaySetting this object will start the output after the
indicated number of seconds, including starting the
UPS, if necessary. -1 mean not startup.
must set upsCtlStartupAfterDelay before upsCtlShutdownDelay ,
the value must larger than 59 if the value not equal -1rw INTEGER (-1..2147483648) UNITS "seconds" .1.3.6.1.4.1.21111.1.1.8.3 |
upsCtlbuzzerSetting this object to 'on' or 'off' to enable or disable buzzerrw Enumeration .1.3.6.1.4.1.21111.1.1.8.4 |
upsCtlRemoteControlUPSSetting this object to turn 'on' or 'off' UPSrw Enumeration .1.3.6.1.4.1.21111.1.1.8.5 |
upsCtloutletPoweronSetting this object to 1 means 1st outlet,2 means 2nd outlet , immediately processrw INTEGER .1.3.6.1.4.1.21111.1.1.8.6 |
upsCtloutletPoweroffSetting this object to 1 means 1st outlet,
2 means 2nd outlet , immediately processrw INTEGER .1.3.6.1.4.1.21111.1.1.8.7 |
upsCtlOutlet1Powerofftimesetting this object to -1 means this control not effect,
0 means immediately process,
>0 means wait times unit is minutes
use in battery moderw INTEGER (-1..999) .1.3.6.1.4.1.21111.1.1.8.8 |
upsCtlOutlet2Powerofftimesetting this object to -1 means this control not effect,
0 means immediately process ,
>0 means wait times unit is minutes .use in battery moderw INTEGER (-1..999) .1.3.6.1.4.1.21111.1.1.8.9 |
upsCtlResetConfigurereset all configure para to default.rw Enumeration .1.3.6.1.4.1.21111.1.1.8.10 |
agentConfig OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1.9 |
agentConfigDatetimeThe datetime in agent, format is (MM/DD/YYYY hh:mm:ss)rw DisplayString .1.3.6.1.4.1.21111.1.1.9.1 |
commConfig OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1.10 |
commBaudRateThe UPS communicate baudraterw Enumeration .1.3.6.1.4.1.21111.1.1.10.1 |
commDatabitsThe UPS communicate data bitsrw INTEGER .1.3.6.1.4.1.21111.1.1.10.2 |
commStopbitsThe UPS communicate stop bitsrw INTEGER .1.3.6.1.4.1.21111.1.1.10.3 |
commParityThe UPS communicate Parityrw Enumeration .1.3.6.1.4.1.21111.1.1.10.4 |
commTimeoutThe UPS communicate timeoutrw INTEGER .1.3.6.1.4.1.21111.1.1.10.5 |
upsConfig OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1.11 |
upsCfgAlarmbypassSetting this object enable /disable alarm bypass moderw Enumeration .1.3.6.1.4.1.21111.1.1.11.1 |
upsCfgAlarmbatterySetting this object enable/disable alarm battery moderw Enumeration .1.3.6.1.4.1.21111.1.1.11.2 |
upsCfgAutoRebootSetting this object enable/disable auto rebootrw Enumeration .1.3.6.1.4.1.21111.1.1.11.3 |
upsCfgBypasswhenupsoffSetting this object start/stop bypass when ups offrw Enumeration .1.3.6.1.4.1.21111.1.1.11.4 |
upsCfgBatterDDPSetting this object to enable/disable battery deep-discharge protectionrw Enumeration .1.3.6.1.4.1.21111.1.1.11.5 |
upsCfgConvertermodeSetting this object to enable/disable converter moderw Enumeration .1.3.6.1.4.1.21111.1.1.11.6 |
upsCfgECOmodeSetting this object to enable/disable ECO moderw Enumeration .1.3.6.1.4.1.21111.1.1.11.7 |
upsCfgAdvanceECOmodeSetting this object to enable/disable advance ECO moderw Enumeration .1.3.6.1.4.1.21111.1.1.11.8 |
upsCfgGreenPowerFunctionSetting this object to enable/disable green power functionrw Enumeration .1.3.6.1.4.1.21111.1.1.11.9 |
upsCfgBatteryOSCSetting this object to enable/disable battery open status checkrw Enumeration .1.3.6.1.4.1.21111.1.1.11.10 |
upsCfgAllowShort3timesSetting this object to enable/disable short 3 timesrw Enumeration .1.3.6.1.4.1.21111.1.1.11.11 |
upsCfgColdstartSetting this object to cold start upsrw Enumeration .1.3.6.1.4.1.21111.1.1.11.12 |
upsCfgBypassNotAllowedSetting this object to enable/disable bypass moderw Enumeration .1.3.6.1.4.1.21111.1.1.11.13 |
upsCfgBatterylowprotectSetting this object to enable/disable battery low protectrw Enumeration .1.3.6.1.4.1.21111.1.1.11.14 |
upsCfgP1progoutletcontrolSetting this object to enable/disable p1 programmable outlet control (battery mode)rw Enumeration .1.3.6.1.4.1.21111.1.1.11.15 |
upsCfgP2progoutletcontrolSetting this object to enable/disable p2 programmable outlet control (battery mode)rw Enumeration .1.3.6.1.4.1.21111.1.1.11.16 |
upsCfgInverterShortClearSetting this object to enable/disable Inverter short clear functionrw Enumeration .1.3.6.1.4.1.21111.1.1.11.17 |
upsCfgSitefaildetectionSetting this object to enable/disable site fail detectionrw Enumeration .1.3.6.1.4.1.21111.1.1.11.18 |
upsCfgBatNumInParallelBattery numbers in parallel (battery numbers setting)rw INTEGER .1.3.6.1.4.1.21111.1.1.11.19 |
upsCfgBatNumInSeriesBattery numbers in series (battery numbers setting)rw INTEGER .1.3.6.1.4.1.21111.1.1.11.20 |
upsCfgBypassmaxvoltageBypass mode max voltagerw INTEGER .1.3.6.1.4.1.21111.1.1.11.21 |
upsCfgBypassminvoltageBypass mode min voltagerw INTEGER .1.3.6.1.4.1.21111.1.1.11.22 |
upsCfgBypassmaxfrequencyBypass mode max frequency ,for 50 HZ (510..600) for 60HZ (610..700)rw INTEGER .1.3.6.1.4.1.21111.1.1.11.23 |
upsCfgBypassminfrequencyBypass mode min frequency, for 50HZ (400..490) for 60Hz (500..590)rw INTEGER .1.3.6.1.4.1.21111.1.1.11.24 |
upsCfgECOmaxvoltageECO mode max voltagerw INTEGER .1.3.6.1.4.1.21111.1.1.11.25 |
upsCfgECOminvoltageECO mode min voltagerw INTEGER .1.3.6.1.4.1.21111.1.1.11.26 |
upsCfgFreeRunMaxFrequencyFree run mode max frequencyrw INTEGER .1.3.6.1.4.1.21111.1.1.11.27 |
upsCfgFreeRunMinFrequencyFree run mode min frequencyrw INTEGER .1.3.6.1.4.1.21111.1.1.11.28 |
upsCfgEPOStatusGet EPO status,configured by mamualro Enumeration .1.3.6.1.4.1.21111.1.1.11.29 |
upsCfgQSK1StatusGet QSK 1 statusro Enumeration .1.3.6.1.4.1.21111.1.1.11.30 |
upsCfgQSK2StatusGet QSK 2 statusro Enumeration .1.3.6.1.4.1.21111.1.1.11.31 |
upsCfgQSKT1DelaytimeGet QSKT 1 time delayro INTEGER .1.3.6.1.4.1.21111.1.1.11.32 |
upsCfgQSKT2DelaytimeGet QSKT 2 time delayro INTEGER .1.3.6.1.4.1.21111.1.1.11.33 |
upsCfgConstantPhaseAnglesetting this object to Enable/disable Constant Phase Angle functionrw Enumeration .1.3.6.1.4.1.21111.1.1.11.34 |
upsCfgInPhaseAngleGet input phase anglero Enumeration .1.3.6.1.4.1.21111.1.1.11.35 |
upsCfgOutPhaseAngleSet output phase anglerw Enumeration .1.3.6.1.4.1.21111.1.1.11.36 |
upsCfgLimiRunOnBatModeEnable/disable limited runtime on battery moderw Enumeration .1.3.6.1.4.1.21111.1.1.11.37 |
upsCfgChargingCurrentSet charging current to battery .ro INTEGER UNITS "0.1 Amp DC" .1.3.6.1.4.1.21111.1.1.11.38 |
upsCfgBatSeftCheckVoltBatTest until battery voltage lower than <nnn>rw INTEGER .1.3.6.1.4.1.21111.1.1.11.39 |
upsCfgOverChargVoltset over charging voltage to per batteryrw INTEGER .1.3.6.1.4.1.21111.1.1.11.40 |
upsCfgBattUnderVoltset battery under voltage of setting value.value is a number ranging from 200V to 240Vrw INTEGER .1.3.6.1.4.1.21111.1.1.11.41 |
upsCfgBattLowVoltset battery low voltage of setting value.it is 10 to 40V high than battery under voltage.
it is 10 to 40V high than battery under voltage.default 20.
it means that the battery low point is battery under add 20.
for example, if the battery under voltage is 210V, the battry low point voltage is 230V.rw INTEGER UNITS "0.1 Volts" .1.3.6.1.4.1.21111.1.1.11.42 |
upsCfgIn1VoltHLossset input1 voltage high loss point.rw INTEGER UNITS "0.1 Volts" .1.3.6.1.4.1.21111.1.1.11.43 |
upsCfgIn1VoltLLossset input1 voltage low loss point.rw INTEGER UNITS "0.1 Volts" .1.3.6.1.4.1.21111.1.1.11.44 |
upsCfgIn2VoltHLossset input2 voltage high loss point.rw INTEGER UNITS "0.1 Volts" .1.3.6.1.4.1.21111.1.1.11.45 |
upsCfgIn2VoltLLossset input2 voltage low loss point.rw INTEGER UNITS "0.1 Volts" .1.3.6.1.4.1.21111.1.1.11.46 |
upsCfgBatteryTurnOnEnable/disable battery turn on.rw Enumeration .1.3.6.1.4.1.21111.1.1.11.47 |
upsTraps OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1.12 |
cmpACFailureAC failure TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.1 |
cmpFanFailureFan failure TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.2 |
cmpUPSFailureUPS failure TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.3 |
cmpChargerFailureCharger failure TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.4 |
cmpOverloadFailureOverload failure TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.5 |
cmpOvertempFailureOver temperature fault. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.6 |
cmpInvertershortcircuitedInverter short-circuited TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.7 |
cmpbatteryfusebeingocBattery fuse being open-dcircuited failure TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.8 |
cmpLowbatteryThe UPS has returned from a low battery
condition. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.9 |
cmpSysgotoshutdownSystem is going to shutdown TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.10 |
cmpSitefaultSite fault TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.11 |
cmpPhasesequenceincorrectPhase sequence incorrect TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.12 |
cmpPhasesequenceincorrectbypassPhase sequence incorrect in bypass TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.13 |
cmpFanalarmFan alarm. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.14 |
cmpEPOenabledEPO enabled TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.15 |
cmpUnabletotrunonUPSUnalbe to turn on UPS TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.16 |
cmpOvertemperaturealarmOver temperature alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.17 |
cmpInputfrequnstablebypassInput frequency unstable in bypass TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.18 |
cmpChargeralarmCharger alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.19 |
cmpL1inputfusenotworkL1 input fuse not working TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.20 |
cmpNeutralnotConnectedNeutral not connected TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.21 |
cmpL2inputfusenotworkL2 input fuse not working TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.22 |
cmpL3inputfusenotworkL3 input fuse not working TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.23 |
cmpPositivePFCabnormalL1Positive PFC abnormal in L1 TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.24 |
cmpNegativePFCabnormalL1Negative PFC abnormal in L1 TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.25 |
cmpPositivePFCabnormalL2Positive PFC abnormal in L2 TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.26 |
cmpNegativePFCabnormalL2Negative PFC abnormal in L2 TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.27 |
cmpPositivePFCabnormalL3Positive PFC abnormal in L3 TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.28 |
cmpNegativePFCabnormalL3Negative PFC abnormal in L3 TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.29 |
cmpBusvoltagenotwdsBus voltage not within default setting TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.30 |
cmpBusvoltageovermaxvalueBus voltage over maxinum value TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.31 |
cmpBusvoltagebelowminvalueBus voltage below mininum value TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.32 |
cmpBusvoltagediffoutofrangeBus voltage differences out fo acceptable range TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.33 |
cmpBusvoltageofsloperatetoofastBus voltage of slope rate drops too fast TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.34 |
cmpOvercurrentinPFCIIWARNING:Over current in PFC input inductor. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.35 |
cmpInvertervoloutofrangeInverter voltage not within default setting. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.36 |
cmpInvertervolovermaxvalueInverter voltage over maximum value. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.37 |
cmpInvertervolbelowminvalueInverter voltage below minimum value. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.38 |
cmpBatteryoppositelyconnectedBattery oppositely connected. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.39 |
cmpL2phaseshortcicuitedL2Phase inverter short-cicuited. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.40 |
cmpL3phaseshortcicuitedL3Phase inverter short-cicuited. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.41 |
cmpL1L2invertershortcicuitedL1L2Inverter short-cicuited. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.42 |
cmpL2L3invertershortcicuitedL2L3Inverter short-cicuited. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.43 |
cmpL3L1invertershortcicuitedL3L1Inverter short-cicuited. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.44 |
cmpL1negativepoweroutofrangeL1 inverter negative powere out of acceptable range. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.45 |
cmpL2negativepoweroutofrangeL2 inverter negative powere out of acceptable range. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.46 |
cmpL3negativepoweroutofrangeL3 inverter negative powere out of acceptable range. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.47 |
cmpBatterySCRshortcircuitedBattery SCR short-circuited. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.48 |
cmpLineSCRshortcircuitedLine SCR short-circuited. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.49 |
cmpInverterrelayopenfaultInverter relay open fault. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.50 |
cmpInverterrelayshortcircuitedInverter relay short-circuited. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.51 |
cmpInoutwiresoppositelyconnectedInput and output wires oppositely connected. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.52 |
cmpabnormalcanbuscommunicationAbnormal in CAN-bus communication. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.53 |
cmpcommfailurebcupsboardCommunication failure between cpus in control board.Or DSP and MCU communication error TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.54 |
cmpabnormalsyncsignalcircuitAbnomal in synchronous signal circuit. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.55 |
cmpabnormalsyncpulsesignalcircuitAbnomal in synchronous pulse signal circuit. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.56 |
cmpcurrent3punbalancedetectedWarning for a three-phase input current unbalance detected. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.57 |
cmpbatteryselftestfailureBattery self-test failure. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.58 |
cmpintercurrentunbalanceInverter inter-current unbalance. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.59 |
cmpbatterydisconnectedBattery disconnected. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.60 |
cmpabnormalhostsignalcircuitAbnormal in host signal circuit. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.61 |
cmpbatteryoverchargedBettery overcharged. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.62 |
cmpbatteryvoltoohighBettery voltage is too high. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.63 |
cmpbatteryvoltoolowBettery voltage is too low. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.64 |
cmpfemaleconnectornotconnwellFemale connector of parallel cable not connected well. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.65 |
cmpmaleconnectornotconnwellMale connector of parallel cable not connected well. TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.66 |
cmplockingbypassA3COW30MLocking inbypass mode after 3 consecutive overloads within 30 minutes TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.67 |
cmpparallelcabledisconnectedParallel cable disconnected TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.68 |
cmpsyncpulsecircuitfaultSynchronous pulse signal circuit fault TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.69 |
cmpsyncsignalcircuitfaltSynchronous signal circuit fault TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.70 |
cmphostsignalcircuitfaultHost signal circuit fault TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.71 |
cmpcanbuscommunicationfaultCan-bus communication fault TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.72 |
cmplowlosspointforvolinACmodeLow loss point for voltage in ac mode not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.73 |
cmphighlosspointforvolinACmodeHigh loss point for voltage in ac mode not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.74 |
cmplowlosspointforfreqinACmodeLow loss point for frequency in ac mode not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.75 |
cmphighlosspointforfreqinACmodeHigh loss point for frequency in ac mode not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.76 |
cmplowlosspointforvolinbypassmodeLow loss point for voltage in bypass mode not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.77 |
cmphighlosspointforvolinbypassmodeHigh loss point for voltage in bypass mode not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.78 |
cmplowlosspointforfreqinbypassmodeLow loss point for frequency in bypass mode not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.79 |
cmphighlosspointforfreqinbypassmodeHigh loss point for frequency in bypass mode not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.80 |
cmploadunbalancedLoad unbalanced TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.81 |
cmpoverloadalarmOverload alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.82 |
cmpparallelnotconnectedwellParallel cable not connected well TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.83 |
cmpcommunicationlostCommunication lost TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.84 |
cmpbatteryconnnotsonsistentBattery connection not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.85 |
cmpconverternotconsisstentConverter setting not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.86 |
cmpbypassnotallownotconsistentBypass not allowed setting not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.87 |
cmpACconnnotconsistentAC connection not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.88 |
cmpinput3pcurrentunbalanceWarning for three-phase ac input current unbalance TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.89 |
cmpbypassconnnotconsistentBypass connection not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.90 |
cmpbatteryprotectionnotconsistentBattery protection setting not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.91 |
cmpbatterydetectionnotconsistentBattery detection setting not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.92 |
cmpupsmodeltypesnotconsistentUPS model types not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.93 |
cmpbypassnotconsistentBypass setting not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.94 |
cmpcapacitynotconsistentCapacity of upss not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.95 |
cmpautorestartnotconsistentAuto restart setting not consistent in parallel systems TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.96 |
cmpBatteryReplaceBattery need to be replace TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.97 |
cmpACNormalAC normal TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.100 |
cmpOutputBadAlarmOutput bad alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.103 |
cmpBypassBadAlarmBypass bad alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.104 |
cmpOutputOffAlarmOutput off alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.105 |
cmpUPSShutAlarmUPS shutdown alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.106 |
cmpSystemOffAlarmSystem off alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.107 |
cmpFuseFailureAlarmFuse failure alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.108 |
cmpGenFailureAlarmGeneral failure alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.109 |
cmpAwaitPowerAlarmAwaiting power alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.110 |
cmpShutPendingAlarmShutdown pending alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.111 |
cmpBatDepletedBattery depleted TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.112 |
cmpUnknowStatusBattery unknow status TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.113 |
cmpOutputOnOutput on TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.114 |
cmpTurntobypassUps turn to bypass mode TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.115 |
cmpTurntobatteryUps turn to battery mode TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.116 |
cmpOutBoosterTurn to booster TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.117 |
cmpOutReducerTurn to reducer TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.118 |
cmpOutBattestTurn to battery test mode TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.119 |
cmpOtherSourceOther source TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.120 |
cmpBatfailureBattery failure TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.121 |
cmpBatTestDonePassedBattery test passed TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.122 |
cmpBatTestDoneWarningBattery test done warning TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.123 |
cmpBatTestDoneAbortedBattery test done Aborted TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.124 |
cmpBatteryNormalBattery normal TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.125 |
cmpBatteryDischargingBattery Discharging TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.126 |
cmpP1cutoffprealarmP1 cut off pre-alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.127 |
cmpInputPhaseErrorWarning for input phase error for LV 6-10K UPS TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.128 |
cmpMaintainSwitchOpenalarmWarning for maintain switch open TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.129 |
cmpEMDChAbnormal1EMD Channels 1 Abnormal TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.130 |
cmpEMDChAbnormal2EMD Channels 2 Abnormal TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.131 |
cmpEMDChAbnormal3EMD Channels 3 Abnormal TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.132 |
cmpEMDChAbnormal4EMD Channels 4 Abnormal TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.133 |
cmpEMDChAbnormal5EMD Channels 5 Abnormal: smoke alarm TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.134 |
cmpEMDChAbnormal6EMD Channels 6 Abnormal TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.135 |
cmpEMDChAbnormal7EMD Channels 7 Abnormal TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.136 |
cmpEMDChAbnormal8EMD Channels 8 Abnormal TRAP-TYPE .1.3.6.1.4.1.21111.1.1.12.0.137 |
trapleafnodev103The share trap-node for send all traps,snmpcard V1-03 and later use this trap-node
char trap[16];
trap[0]: trap[0]=1,fault trap ; trap[0]=0,warn trap DisplayString .1.3.6.1.4.1.21111.1.1.12.998 |
trapleafnodev1v2The share trap-node for send all traps INTEGER .1.3.6.1.4.1.21111.1.1.12.999 |
extend OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.1.13 |
extendWorkTemperatureThe temperature of work environmentro INTEGER (-2200..2200) UNITS "degrees 0.1 Centigrade" .1.3.6.1.4.1.21111.1.1.13.1 |
extendWorkhumidityThe humidity of work environmentro INTEGER .1.3.6.1.4.1.21111.1.1.13.2 |
extendSmokeScopeThe smokeScope of work environmentro INTEGER .1.3.6.1.4.1.21111.1.1.13.3 |
extendEMDAlarm1Environment detector alarm 1ro Enumeration .1.3.6.1.4.1.21111.1.1.13.4 |
extendEMDAlarm2Environment detector alarm 2ro Enumeration .1.3.6.1.4.1.21111.1.1.13.5 |
extendEMDAlarm3Environment detector alarm 3ro Enumeration .1.3.6.1.4.1.21111.1.1.13.6 |
extendEMDAlarm4Environment detector alarm 4ro Enumeration .1.3.6.1.4.1.21111.1.1.13.7 |
inverter OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2 |
solarIdent OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.1 |
solarRating OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.2 |
solarBattery OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.3 |
solarGrid OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.4 |
solarACOutput OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.5 |
solarPV OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.6 |
solarEnergy OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.7 |
solarTest OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.8 |
solarDefValue OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.9 |
solarFaultInfo OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.10 |
solarControl OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.11 |
solarAgentConfig OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.12 |
solarCommConfig OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.13 |
solarConfig OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.14 |
solarTraps OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.15 |
solarExtend OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.2.16 |
charger OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.3 |
ATS OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.4 |
ATSIdent OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.4.1 |
ATSRating OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.4.2 |
ATSInformation OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.4.3 |
ATSControl OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.4.4 |
ATSAgentConfig OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.4.5 |
ATSCommConfig OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.4.6 |
ATSConfig OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.4.7 |
ATSTraps OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.4.8 |
ATSExtend OBJECT IDENTIFIER .1.3.6.1.4.1.21111.1.4.9 |